Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Where Are the r-modes? Chandra Observations of Millisecond Pulsars

We present the results of Chandra observations of two non-accreting millisecond pulsars, PSRs J1640+2224 (J1640) and J1709+2313 (J1709), with low inferred magnetic fields and spin-down rates in order to constrain their surface temperatures, obtain limits on the amplitude of unstable r -modes in them, and make comparisons with similar limits obtained for a sample of accreting low-mass X-ray binary (LMXB) neutron stars. We detect both pulsars in the X-ray band for the first time. They are faint, with inferred soft X-ray fluxes (0.3–3 keV) of ≈6 × 10{sup −15} and 3 × 10{sup −15} erg cm{sup −2} s{sup −1} for J1640 and J1709, respectively. Spectral analysis assuming hydrogen atmosphere emission gives global effective temperature upper limits (90% confidence) of 3.3–4.3 × 10{sup 5} K for J1640 and 3.6–4.7 × 10{sup 5} K for J1709, where the low end of the range corresponds to canonical neutron stars ( M = 1.4 M {sub ⊙}), and the upper end corresponds to higher-mass stars ( M = 2.21 M {sub ⊙}). Under the assumption that r -mode heating provides the thermal support, we obtain dimensionless r -mode amplitude upper limits of 3.2–4.8 × 10{sup −8} and 1.8–2.8 × 10{sup −7} for J1640 and J1709, respectively, where again the low end of the range corresponds to lower-mass, canonical neutron stars ( M = 1.4 M {sub ⊙}). These limits are about an order of magnitude lower than those we derived previously for a sample of LMXBs, except for the accreting millisecond X-ray pulsar SAX J1808.4–3658, which has a comparable amplitude limit to J1640 and J1709.

79 ASTRONOMY AND ASTROPHYSICS↗

Where are the r-modes? Chandra Observations of Millisecond Pulsars

We present the results of Chandra observations of two non-accreting millisecond pulsars, PSRs J1640+2224(J1640) and J1709+2313 (J1709), with low inferred magnetic fields and spin-down rates in order to constrain their surface temperatures, obtain limits on the amplitude of unstable r-modes in them, and make comparisons with similar limits obtained for a sample of accreting low-mass X-ray binary (LMXB) neutron stars. We detect both pulsars in the X-ray band for the first time. They are faint, with inferred soft X-ray fluxes(0.3-3 keV) of approx. 6 x 10(exp -15) and 3 x 10( exp -15) erg/sq cm for J1640 and J1709, respectively. Spectral analysis assuming hydrogen atmosphere emission gives global effective temperature upper limits (90% confidence) of 3.3-4.3 x 10(exp 5) K for J1640 and 3.6-4.7 x 10(exp 5) K for J1709, where the low end of the range corresponds to canonical neutron stars (M = 1.4 Stellar Mass), and the upper end corresponds to higher-mass stars (M = 2.21 Stellar Mass). Under the assumption that r-mode heating provides the thermal support, we obtain dimensionless r-mode amplitude upper limits of 3.2-4.8 x 10(exp -8) and 1.8-2.8 x 10(exp -7) for J1640 and J1709, respectively, where again the low end of the range corresponds to lower-mass, canonical neutron stars (M =1.4 Stellar Mass). These limits are about an order of magnitude lower than those we derived previously for a sample of LMXBs, except for the accreting millisecond X-ray pulsar SAX J1808.43658, which has a comparable amplitude limit to J1640 and J1709.

oscillations↗

Probing Nuclear Structure with Fast Neutrons

The advantages of using inelastic neutron scattering with detection of the emitted {gamma} rays, i.e., the (n,n'{gamma}) reaction, for exploring the structure of stable nuclei are reviewed. Examples of the information available with these techniques are provided and progress in understanding multiphonon excitations is described. The unique nuclear structure of {sup 94}Zr is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton emission in ultraperipheral Pb-Pb collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02 TeV

The first measurements of proton emission accompanied by neutron emission in the electromagnetic dissociation (EMD) of 208 Pb nuclei in the ALICE experiment at the Large Hadron Collider are presented. The EMD protons and neutrons emitted at very forward rapidities are detected by the proton and neutron zero degree calorimeters of the ALICE experiment. The emission cross sections of zero, one, two, and three protons accompanied by at least one neutron were measured in ultraperipheral 208 Pb − 208 Pb collisions at a center-of-mass energy per nucleon pair $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02TeV. The 0p and 3p cross sections are described by the RELDIS model within their measurement uncertainties, while the 1p and 2p cross sections are underestimated by the model by 17–25%. According to this model, these 0p, 1p, 2p, and 3p cross sections are associated, respectively, with the production of various isotopes of Pb, Tl, Hg, and Au in the EMD of 208 Pb . The cross sections of the emission of a single proton accompanied by the emission of one, two, or three neutrons in EMD were also measured. The data are significantly overestimated by the RELDIS model, which predicts that the (1p,1n), (1p,2n), and (1p,3n) cross sections are very similar to the cross sections for the production of the thallium isotopes 206,205,204 Tl.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of damage induced by heavy neutron irradiation on multilayered {sup 6}LiF-single crystal chemical vapor deposition diamond detectors

High performance neutron detectors sensitive to both thermal and fast neutrons are of great interest to monitor the high neutron flux produced, e.g., by fission and fusion reactors. An obvious requirement for such an application is neutron irradiation hardness. This is why diamond based neutron detectors are currently under test in some of these facilities. In this paper the damaging effects induced in chemical vapor deposition (CVD) diamond based detectors by a neutron fluence of approx2x10{sup 16} neutrons/cm{sup 2} have been studied and significant changes in spectroscopic, electrical, and optical properties have been observed. The detectors are fabricated using high quality synthetic CVD single crystal diamond using the p-type/intrinsic/Schottky metal/{sup 6}LiF layered structure recently proposed by Marinelli et al. [Appl. Phys. Lett. 89, 143509 (2006)], which allows simultaneous detection of thermal and fast neutrons. Neutron radiation hardness up to at least 2x10{sup 14} n/cm{sup 2} fast (14 MeV) neutron fluence has been confirmed so far [see Pillon et al., (Fusion Eng. Des. 82, 1174 (2007)]. However, at the much higher neutron fluence of approx2x10{sup 16} neutrons/cm{sup 2} damage is observed. The detector response to 5.5 MeV {sup 241}Am alpha-particles still shows a well resolved alpha-peak, thus confirming the good radiation hardness of the device but a remarkable degradation and a significant instability with time of charge collection efficiency and energy resolution arise. Symmetric, nearly Ohmic I-V (current-voltage) characteristics have been recorded from the metal/intrinsic/p-doped diamond layered structure, which before neutron irradiation acted as a Schottky barrier diode with a strong rectifying behavior. The nature and the distribution of the radiation induced damage have been deeply examined by means of cathodoluminescence spectroscopy. A more heavily damaged area into the intrinsic diamond at the same position and with the same extension of the {sup 6}LiF layer has been found, the increased damage being ascribed to the highly ionizing particles produced in the {sup 6}LiF layer by thermal neutrons through the nuclear reaction {sup 6}Li(n,alpha)T.

36 MATERIALS SCIENCE↗

A radial collimator for a time-of-flight neutron spectrometer

We have engineered and installed a radial collimator for use in the scattered beam of a neutron time-of-flight spectrometer at a spallation neutron source. The radial collimator may be used with both thermal and epithermal neutrons, reducing the detected scattering intensity due to material outside of the sample region substantially. The collimator is located inside of the sample chamber of the instrument, which routinely cycles between atmospheric conditions and cryogenic vacuum. The oscillation and support mechanism of the collimator allow it to be removed from use without breaking vacuum. We describe here the design and characterization of this radial collimator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing gravitational wave detector networks: from A # to cosmic explorer

Gravitational-wave observations by the laser interferometer gravitational-wave observatory (LIGO) and Virgo have provided us a new tool to explore the Universe on all scales from nuclear physics to the cosmos and have the massive potential to further impact fundamental physics, astrophysics, and cosmology for decades to come. In this paper we have studied the science capabilities of a network of LIGO detectors when they reach their best possible sensitivity, called A # , given the infrastructure in which they exist and a new generation of observatories that are factor of 10 to 100 times more sensitive (depending on the frequency), in particular a pair of L-shaped cosmic explorer (CE) observatories (one 40 km and one 20 km arm length) in the US and the triangular Einstein telescope with 10 km arms in Europe. We use a set of science metrics derived from the top priorities of several funding agencies to characterize the science capabilities of different networks. The presence of one or two A # observatories in a network containing two or one next generation observatories, respectively, will provide good localization capabilities for facilitating multimessenger astronomy (MMA) and precision measurement of the Hubble parameter. Two CE observatories are indispensable for achieving precise localization of binary neutron star events, facilitating detection of electromagnetic counterparts and transforming MMA. Their combined operation is even more important in the detection and localization of high-redshift sources, such as binary neutron stars, beyond the star-formation peak, and primordial black hole mergers, which may occur roughly 100 million years after the Big Bang. The addition of the Einstein Telescope to a network of two CE observatories is critical for accomplishing all the identified science metrics including the nuclear equation of state, cosmological parameters, the growth of black holes through cosmic history, but also make new discoveries such as the presence of dark matter within or around neutron stars and black holes, continuous gravitational waves from rotating neutron stars, transient signals from supernovae, and the production of stellar-mass black holes in the early Universe. For most metrics the triple network of next generation terrestrial observatories are a factor 100 better than what can be accomplished by a network of three A # observatories.

Einstein telescope↗

Applying the neutron scatter camera to treaty verification and warhead monitoring.

The neutron scatter camera was originally developed for a range of SNM detection applications. We are now exploring the feasibility of applications in treaty verification and warhead monitoring using experimentation, maximum likelihood estimation method (MLEM), detector optimization, and MCNP-PoliMi simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute calibration of microfission chamber in JT-60U

We have conducted calibrations of a microfission chamber, which was installed between the vacuum vessel and the toroidal field coils, by both a Cf-252 neutron source and real deuterium plasmas in JT-60U. The detector employs both pulse counting and Campbell (mean square voltage) modes in the electronics to cover a wide dynamic range of the neutron source strength. The pulse counting and Campbell modes were calibrated by Cf-252 and deuterium plasmas, respectively. Point efficiencies, counts per neutron from a point at a single angle, were measured for 27 locations of the neutron point source in toroidal scan. The efficiencies were influenced by the various components such as the vacuum vessel, port, and graphite tiles. The point efficiencies can be integrated and averaged with angle to provide toroidal line efficiencies. The line efficiencies of the microfission chamber and the nearest neutron monitor of the U-235 fission chamber were 5.38x10{sup -9} and 1.77x10{sup -8}, respectively. Then the calibration for the Campbell mode was also performed by using a real deuterium plasma. The detection efficiency in the Campbell mode was about three-tenths of that of the nearest neutron monitor, which is consistent with the calibration result obtained by using a Cf-252 neutron source for pulse counting mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and lattice excitations of the copper substituted lead oxyapatite Pb 9.06⁢(7)⁢ Cu 0.94⁢(6)⁢ (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3)

The copper substituted lead oxyapatite, Pb 10-x⁢ Cu x (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3) [x = 0.94(6)] was studied using neutron and x-ray diffraction and neutron spectroscopy techniques. The crystal structure of the main phase of our sample, which has come to be colloquially known as LK-99, is verified to possess a hexagonal structure with space group P6 3 /m, alongside the presence of impurity phases Cu and Cu 2 ⁢S. We determine the primary substitution location of the Cu as the Pb1 (6⁢ℎ) site, with a small substitution at the Pb2 (4⁢f) site. Consequently, no clear Cu-doping-induced structural distortion was observed in the investigated temperature region between 10 K and 300 K. Specially, we did not observe a reduction of coordinate number at the Pb2 site or a clear tilting of PO 4 tetrahedron. Magnetic characterization reveals a diamagnetic signal in the specimen, accompanied by a very weak ferromagnetic component at 2 K. No long-range magnetic order down to 10 K was detected by the neutron diffraction. Inelastic neutron scattering measurements did not show magnetic excitations for energies up to 350 meV. There is no sign of a superconducting resonance in the excitation spectrum of this material. The measured phonon density of states compares well with density functional theory calculations performed for the main LK-99 phase and its impurity phases. Our study may shed some insight into the role of the favored substitution site of copper in the absence of structural distortion and superconductivity in LK-99.

36 MATERIALS SCIENCE↗

Two-Exponential Rossi-Alpha Analysis of Copper- and Polyethylene-Reflected Plutonium

The prompt neutron decay constant $\mathcal{α}$, which is used to infer reactivity, is estimated using the Rossi-alpha technique that is predicated on fitting Rossi-alpha histograms. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector-induced phenomenon. Recent work also validated the two-exponential model for shields, a subset of reflectors, but not for reflectors in general. Ultimately, it is desirable to validate the two-exponential model for the general shield. This work will investigate if previous 3 He measurements of plutonium reflected by copper and polyethylene, and replacement measurements where the plutonium is replaced by 252 Cf are suitable for validating the new model. Since the 3 He detectors ( 3 He gas proportional counters embedded in a polyethylene matrix) inherently contain moderating/reflector material (to increase detection efficiency), this work also investigates the use of organic scintillation detectors that can directly detect fast, fission neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Crystal and magnetic study of the disordered perovskites Ca(Mn{sub 0.5}Sb{sub 0.5})O{sub 3} and Ca(Fe{sub 0.5}Sb{sub 0.5})O{sub 3}

We have investigated the double perovskites Ca{sub 2}MSbO{sub 6} (M = Mn, Fe) that have been prepared by solid-state reaction (M = Fe) and wet chemistry procedures (M = Mn). The crystal and magnetic structures have been studied from X-ray (XRD) and neutron powder diffraction (NPD) data. Rietveld refinements show that the crystal structures are orthorhombic (space group Pbnm) with complete disorder of M and Sb cations, so the formula should be rewritten as Ca(M{sub 0.5}Sb{sub 0.5})O{sub 3}. Due to this disorder no evidences of Jahn-Teller distortion can be observed in the MnO{sub 6} octahedra of Ca(Mn{sub 0.5}Sb{sub 0.5})O{sub 3}, in contrast with the ordered double perovskite Sr{sub 2}MnSbO{sub 6}. Ca(Fe{sub 0.5}Sb{sub 0.5})O{sub 3} behaves as an antiferromagnet with an ordered magnetic moment for Fe{sup 3+} of 1.53(4){mu}{sub B} and a propagation vector k = 0, as investigated by low-temperature NPD. The antiferromagnetic ordering is a result of the high degree of Fe/Sb anti-site disorder of the sample, which originates the spontaneous formation of Fe-rich islands, characterized by the presence of strong Fe-O-Fe antiferromagnetic couplings with enough long-range coherence to produce a magnetic contribution perceptible by NPD. By contrast, the magnetic structure of Ca(Mn{sub 0.5}Sb{sub 0.5})O{sub 3} cannot be observed by low-temperature NPD because the magnitude of the ordered magnetic moments is below the detection threshold for neutrons.

36 MATERIALS SCIENCE↗

Magnetic phase transformations and magnetotransport phenomena in La{sub 0.7}Sr{sub 0.3}Mn{sub 1–} {sub x}Co{sub x}O{sub 3} perovskite compounds

The compositions La{sub 0.7}Sr{sub 0.3}Mn{sub 1–} {sub x}Co{sub x}O{sub 3} (0.13 ≤ x ≤ 1) are studied by neutron diffraction, magnetometry, and measuring the magnetotransport properties. The substitution of cobalt ions for manganese ions is shown to decrease the magnetization and the Curie temperature from 270 K (x = 0.13) to 140 K (x = 0.33). As the cobalt ion content increases to x = 0.5, the Curie temperature increases to 190 K, the magnetization decreases, and the electrical resistivity increases. At x > 0.5, the temperature of transition into a paramagnetic state decreases to 68 K (x = 0.8) and then again increases to 225 K for the La{sub 0.7}Sr{sub 0.3}CoO{sub 3} composition. The magnetoresistive effect in the range 0.3 ≤ x ≤ 0.4 reaches 97% and decreases gradually with increasing temperature without anomalies near the Curie point. At x ≤ 0.2, the magnetoresistive effect increases near the Curie temperature. The composition at x = 0.6 is stoichiometric, and no coherent magnetic contribution to neutron scattering is detected. The magnetic properties near x ∼ 0.5 are assumed to be caused by partial ordering of Co{sup 3+} and Mn{sup 4+} ions, and the Co{sup 3+} ions can be in both low- and high-spin states. The magnetic interaction between Co{sup 3+} ions in a high-spin state and Mn{sup 4+} is predominantly ferromagnetic, and the ferromagnetic part of the exchange interactions is close to the ferromagnetic part. These data are used to plot a magnetic La{sub 0.7}Sr{sub 0.3}Mn{sub 1–} {sub x}Co{sub x}O{sub 3} phase diagram.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Growth and device processing of hexagonal boron nitride epilayers for thermal neutron and deep ultraviolet detectors

Solid-state neutron detectors with high performance are highly sought after for the detection of fissile materials. However, direct-conversion neutron detectors based on semiconductors with a measureable efficiency have not been realized. We report here the first successful demonstration of a direct-conversion semiconductor neutron detector with an overall detection efficiency for thermal neutrons of 4% and a charge collection efficiency as high as 83%. The detector is based on a 2.7 μm thick {sup 10}B-enriched hexagonal boron nitride (h-BN) epitaxial layer. The results represent a significant step towards the realization of practical neutron detectors based on h-BN epilayers. Neutron detectors based on h-BN are expected to possess all the advantages of semiconductor devices including wafer-scale processing, compact size, light weight, and ability to integrate with other functional devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Environment of the Binary Neutron Star Merger GW170817

We present Hubble Space Telescope (HST) and Chandra imaging, combined with Very Large Telescope MUSE integral field spectroscopy of the counterpart and host galaxy of the first binary neutron star merger detected via gravitational-wave emission by LIGO and Virgo, GW170817. The host galaxy, NGC 4993, is an S0 galaxy at z = 0.009783. There is evidence for large, face-on spiral shells in continuum imaging, and edge-on spiral features visible in nebular emission lines. This suggests that NGC 4993 has undergone a relatively recent (≲1 Gyr) “dry” merger. This merger may provide the fuel for a weak active nucleus seen in Chandra imaging. At the location of the counterpart, HST imaging implies there is no globular or young stellar cluster, with a limit of a few thousand solar masses for any young system. The population in the vicinity is predominantly old with ≲1% of any light arising from a population with ages <500 Myr. Both the host galaxy properties and those of the transient location are consistent with the distributions seen for short-duration gamma-ray bursts, although the source position lies well within the effective radius (r{sub e}∼3 kpc), providing an r {sub e}-normalized offset that is closer than ∼90% of short GRBs. For the long delay time implied by the stellar population, this suggests that the kick velocity was significantly less than the galaxy escape velocity. We do not see any narrow host galaxy interstellar medium features within the counterpart spectrum, implying low extinction, and that the binary may lie in front of the bulk of the host galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

The Electromagnetic Counterpart of the Binary Neutron Star Merger LIGO/Virgo GW170817. I. Discovery of the Optical Counterpart Using the Dark Energy Camera

Here, we present the Dark Energy Camera (DECam) discovery of the optical counterpart of the first binary neutron star merger detected through gravitational-wave emission, GW170817. Our observations commenced 10.5 hr post-merger, as soon as the localization region became accessible from Chile. We imaged 70 deg 2 in the i and z bands, covering 93% of the initial integrated localization probability, to a depth necessary to identify likely optical counterparts (e.g., a kilonova). At 11.4 hr post-merger we detected a bright optical transient located $10\buildrel{\prime\prime}\over{.} 6$ from the nucleus of NGC 4993 at redshift z = 0.0098, consistent (for ${H}_{0}=70$ km s –1 Mpc –1 ) with the distance of 40 ± 8 Mpc reported by the LIGO Scientific Collaboration and the Virgo Collaboration (LVC). At detection the transient had magnitudes of $i=17.3$ and $z=17.4$, and thus an absolute magnitude of ${M}_{i}=-15.7$, in the luminosity range expected for a kilonova. We identified 1500 potential transient candidates. Applying simple selection criteria aimed at rejecting background events such as supernovae, we find the transient associated with NGC 4993 as the only remaining plausible counterpart, and reject chance coincidence at the 99.5% confidence level. We therefore conclude that the optical counterpart we have identified near NGC 4993 is associated with GW170817. This discovery ushers in the era of multi-messenger astronomy with gravitational waves and demonstrates the power of DECam to identify the optical counterparts of gravitational-wave sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Benchmarking of a Proton Recoil Neutron Detector

A neutron spectroscopy detector was designed for analysis of neutrons produced by Lawrence Livermore National Laboratory's neutron imaging project. The detector was built and benchmarked at Lawrence Berkeley National Laboratory's Deuteron-Breakup Neutron Facility. Similar to a proton-recoil telescope, the setup detects protons elastically scattered from neutrons incident on a thin sheet of polyethylene. A silicon charged-particle detector several centimeters away detects the protons in a small angular range, such that the energies of the incident neutrons can be reconstructed from the energy of the detected proton and the scattering angle. A quick benchmarking experiment demonstrated that large backgrounds would be a significant challenge, and that additional measures must be taken to reduce these backgrounds. A Geant4 model of the detector was used to predict the sources of these backgrounds and how best to reduce them.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗