Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal system modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Simple Forest Canopy Thermal Exitance Model

We describe a model to calculate brightness temperature and surface energy balance for a forest canopy system. The model is an extension of an earlier vegetation only model by inclusion of a simple soil layer. The root mean square error in brightness temperature for a dense forest canopy was 2.5 C. Surface energy balance predictions were also in good agreement. The corresponding root mean square errors for net radiation, latent, and sensible heat were 38.9, 30.7, and 41.4 W/sq m respectively.

Smith J. A.↗

Advanced Power Electronics and Electric Machines

NLR's advanced power electronics and electric machines (APEEM) research group develops world-class experimental and modeling capabilities to design and evaluate efficient and reliable power electronics and electric machines, as well as innovative thermal management systems to maximize their performance. They also design, fabricate, and characterize advanced power electronics packaging and are developing state-of-health monitoring techniques.

25 ENERGY STORAGE↗

A predictive model of human performance.

An attempt is made to develop a model describing the overall responses of humans to exercise and environmental stresses for prediction of exhaustion vs an individual's physical characteristics. The principal components of the model are a steady state description of circulation and a dynamic description of thermal regulation. The circulatory portion of the system accepts changes in work load and oxygen pressure, while the thermal portion is influenced by external factors of ambient temperature, humidity and air movement, affecting skin blood flow. The operation of the model is discussed and its structural details are given.

Walters, R. F.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Numerical Modeling of Self-Pressurization and Pressure Control by Thermodynamic Vent System in a Cryogenic Tank

This paper presents a numerical model of a system-level test bed - the multipurpose hydrogen test bed (MHTB) using Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a fully integrated space transportation vehicle liquid hydrogen (LH2) propellant tank and was tested at Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume based network flow analysis software developed at MSFC and used for thermo-fluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger, and a mixing pump and spray to extract thermal energy from the tank without significant loss of liquid propellant. Two GFSSP models (Self-Pressurization & TVS) were separately developed and tested and then integrated to simulate the entire system. Self-Pressurization model consists of multiple ullage nodes, propellant node and solid nodes; it computes the heat transfer through Multi-Layer Insulation blankets and calculates heat and mass transfer between ullage and liquid propellant and ullage and tank wall. TVS model calculates the flow through J-T valve, heat exchanger and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. The integrated models results have been compared with MHTB test data of 50% fill level. Satisfactory comparison was observed between test and numerical predictions.

Majumdar, Alok↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services: Preprint

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-themeter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗

Centaur Propellant Thermal Conditioning Study

A wicking investigation revealed that passive thermal conditioning was feasible and provided considerable weight advantage over active systems using throttled vent fluid in a Centaur D-1s launch vehicle. Experimental wicking correlations were obtained using empirical revisions to the analytical flow model. Thermal subcoolers were evaluated parametrically as a function of tank pressure and NPSP. Results showed that the RL10 category I engine was the best candidate for boost pump replacement and the option showing the lowest weight penalty employed passively cooled acquisition devices, thermal subcoolers, dry ducts between burns and pumping of subcooler coolant back into the tank. A mixing correlation was identified for sizing the thermodynamic vent system mixer. Worst case mixing requirements were determined by surveying Centaur D-1T, D-1S, IUS, and space tug vehicles. Vent system sizing was based upon worst case requirements. Thermodynamic vent system/mixer weights were determined for each vehicle.

Blatt, M. H.↗

A Phenomenological Thermal Spray Wall Interaction Modeling Framework Applied to a High Temperature Ignition Assistant Device

Airborne compression ignition engines must operate with reliable ignition systems to achieve proper ignition at every cycle, particularly at high altitudes. Glow-plug-based ignition-assistant (IA) devices can provide the necessary energy to preheat the fuel and ensure ignitability of the fuel-air mixture. Ignitability of liquid sprays can be facilitated via direct impingement onto the hot IA surface, however this comes with adverse effects on the IA durability. Therefore, optimizing an IA’s design requires detailed understanding of the physics of fuel spray impingement of superheated surfaces. While spray impingement on relatively low wall temperatures has been extensively studied and appropriate numerical models have been proposed through the years, fundamental understanding of high-speed liquid spray impingement on superheated walls is still elusive. This work aims to formulate a phenomenological thermal spray-wall interaction framework for modeling the film-boiling-induced heat transfer, atomization, and dispersion of fuel spray droplets impinging onto a superheated IA device. A qualitative comparison of the new phenomenological model is performed against optical experiments from the literature of an F-24 fuel spray injected onto an IA device located 12 mm away from the injector tip. The temperature of the IA was set at 1400 K. The fuel injection pressure was 400 bar, while the ambient gas pressure and temperature were 30 bar and 800 K, respectively. The performance of the phenomenological model is evaluated in comparison with two other state-of-art models from the literature. A qualitative analysis of the different spray and fuel-air mixture characteristics is performed to outline the differences in the predictions offered by the new phenomenological model and the two state-of-art spray-wall interaction models.

droplet dispersion↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-the-meter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗

Near Earth Asteroid Scout Solar Sail Engineering Development Unit Test Suite

The Near Earth Asteroid (NEA) Scout project is a 6U reconnaissance mission to investigate a near Earth asteroid utilizing an 86m(sub 2) solar sail as the primary propulsion system. This will be the largest solar sail NASA has launched to date. NEA Scout is currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis was able to capture understanding of thermal, stress, and dynamics of the stowed system as well as mature an integrated sail membrane model for deployed flight dynamics. Full scale system testing on the ground is the optimal way to demonstrate system robustness, repeatability, and overall performance on a compressed flight schedule. To physically test the system, the team developed a flight sized engineering development unit with design features as close to flight as possible. The test suite included ascent vent, random vibration, functional deployments, thermal vacuum, and full sail deployments. All of these tests contributed towards development of the final flight unit. This paper will address several of the design challenges and lessons learned from the NEA Scout solar sail subsystem engineering development unit. Testing on the component level all the way to the integrated subsystem level. From optical properties of the sail material to fold and spooling the single sail, the team has developed a robust deployment system for the solar sail. The team completed several deployments of the sail system in preparation for flight at half scale (4m) and full scale (6.8m): boom only, half scale sail deployment, and full scale sail deployment. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

Lockett, Tiffany Russell↗

Methane Lunar Surface Thermal Control Test

NASA is considering propulsion system concepts for future missions including human return to the lunar surface. Studies have identified cryogenic methane (LCH4) and oxygen (LO2) as a desirable propellant combination for the lunar surface ascent propulsion system, and they point to a surface stay requirement of 180 days. To meet this requirement, a test article was prepared with state-of-the-art insulation and tested in simulated lunar mission environments at NASA GRC. The primary goals were to validate design and models of the key thermal control technologies to store unvented methane for long durations, with a low-density high-performing Multi-layer Insulation (MLI) system to protect the propellant tanks from the environmental heat of low Earth orbit (LEO), Earth to Moon transit, lunar surface, and with the LCH4 initially densified. The data and accompanying analysis shows this storage design would have fallen well short of the unvented 180 day storage requirement, due to the MLI density being much higher than intended, its substructure collapse, and blanket separation during depressurization. Despite the performance issue, insight into analytical models and MLI construction was gained. Such modeling is important for the effective design of flight vehicle concepts, such as in-space cryogenic depots or in-space cryogenic propulsion stages.

Plachta, David W.↗

Analysis of Thermal-Protection Systems for Space-Vehicle Cryogenic-Propellant Tanks

Analytical techniques are presented that permit the calculation of heat-transfer rates with various thermal-protection systems for liquid-cryogenic-propellant tanks subjected to on-board, solar, and planetary heat fluxes. The thermal-protection systems considered include using closely spaced reflective surfaces (foils) and widely spaced reflective surfaces (shadow shields), insulation, arrangement of vehicle components, orientation with respect to radiant heating sources, and coatings for the control of solar absorptivity. The effectiveness of these thermal-protection systems in reducing propellant heating is shown both for ideal heat-transfer models and for a simplified hydrogen-oxygen terminal stage on a Mars mission. The proper orientation of a space-vehicle cryogenic tank with respect to the Sun is one of the more beneficial methods of reducing the heating effect of solar flux. Shadow shields can be extremely effective in reducing the propellant heating due to both solar and on-board fluxes. However, low-altitude planet orbits can result in high propellant heating rates due to planetary radiation reflected from the shields. For low-altitude orbits of more than a few days, foils appear to be desirable for all cryogenic-tank surfaces. Foils are also effective in reducing the on-board heating. A choice of shadow shields or foils cannot be made until a particular vehicle and a particular mission are chosen. The thermal conductivity of insulation materials would have to be lower by about two orders of magnitude with no increase in density before insulation could compete with reflective surfaces for use in long-duration thermal protection of cryogenic tanks in space. To demonstrate the application of the methods devised, thermal-protection systems are developed for a hydrogen-oxygen terminal stage for typical Mars missions.

SPACE VEHICLE↗

CFD modeling of crystallization fouling with CO 2 desorption incorporated for a falling-film evaporator in thermal desalination

Seawater flowing around horizontal tubes in falling-film evaporators is a common configuration for thermal desalination. Heat is transferred from in-tube steam condensation to the shell-side seawater by conduction through the tube wall and scaling layer, and conduction and convection to the evaporating liquid film. CO 2 is simultaneously released from seawater and mixed with the produced vapor. Fouling coupled with CO 2 desorption has deleterious impacts on both evaporation and condensation. The evaluation of spatiotemporal dependent crystallization fouling and CO 2 desorption is vital to selecting optimal operating conditions. Here, in this work, a CO 2 desorption model is integrated into CFD modeling for predictions of coupled heat and mass transfer, to understand and predict scale formation and CO 2 desorption with local and transient profiles of temperature, carbonate species concentrations, pH, and total alkalinity. The porosity of the scale layer is experimentally determined as 67.7% and invoked in the calculation of effective thermal conductivity. The simulation results reveal that high steam temperatures increase seawater total alkalinity and accelerate scale formation. The scale thickness on the bottom tube reaches 0.30 μm and 5.24 μm for steam temperatures of 60 °C and 80 °C, respectively. High salinity leads to a large CO 2 desorption rates. The CO 2 desorption rate increases 43% when the seawater salinity increases from 35 to 55 g/kg. The effects of operating conditions on carbonate speciation and pH have been compared and analyzed. This model can serve as a comprehensive tool for the design of thermal desalination systems and optimal operation.

42 ENGINEERING↗

A mathematical model of solid-state dewetting of barium thin films on W (112)

Solid state dewetting occurs when a thin solid film is heated. The temperature of dewetting depends on the thickness of the film; dewetting can be observed in the range of 1/3 to 1/2 of the bulk melting temperature. While remaining solid, the film behaves in a manner similar to liquids dewetting and agglomerating to forming islands or droplets. One of the possible mechanisms is the conversion of a metastable thin film geometry into a more stable form. Heating the metastable film gives the film atoms higher mobility, and the films retract, dewetting the surface. This atomic motion can be restricted due to surface anisotropy. Herein we present in situ emission microscopy observations of barium thin films deposited onto W (112) by thermal evaporation. From the modeling viewpoint, the evolution of the film in this system could be divided in four stages: (i) the nucleation and growth of the thin film as a simply connected region; (ii) formation of droplets/islands/hillocks; (iii) nucleation of holes; (iv) evolution of the components of the disconnected film to their equilibrium state. We present a continuum model that is qualitatively consistent with the evolution of the film observed at the initial stage of the experiment and discuss the later stages of the evolution of surface structures.

36 MATERIALS SCIENCE↗

Community Geothermal: Soil Conductivity, Borehole Design, Energy Models, and Load Data for a Residential System Development - Hinesburg, VT

This dataset contains materials from the Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES) project, which evaluated the techno-economic feasibility of a community geothermal system for a residential development in Hinesburg, VT. The dataset includes detailed soil conductivity test reports, energy models, borehole design reports, hourly energy loads for heating, cooling, and hot water, and design layouts. EnergyPlus was used to model building energy loads, and Modelica software was applied for geothermal loop sizing based on these loads and soil conductivity results. Python scripts for network design further refined the models. Key files include PDF reports on borehole design (with projections for 1-year, 15-year, and 30-year systems), soil conductivity test results, EnergyPlus modeling outputs, and 2D/3D design drawings in PDF, DWG, and DXF formats. Python notebooks for network design and OnePipe model files are also provided, with Modelica required for viewing certain files. Outputs and modeling data are in various formats including CSV, JPG, HTML, and IDF, with units and data clearly labeled to support understanding of system design and performance for the proposed geothermal solution.

15 GEOTHERMAL ENERGY↗

Large Load Impacts to Distribution System Hosting Capacity

This work examined the impact of large loads on utility distribution system models using the Sandia-developed open-source software DREAMS. It was shown that hosting capacity varies with location and changes after any asset is added to, or removed from, a system. Despite the tested models having similar rated voltages and other characteristics, their thermal and voltage constrained hosting capacity varied over 2 MW. The addition of a 3-phase balanced constant power large load with power factor of 1.0 exhibited non-linear reductions to all voltage constrained hosting capacities. The reductions to thermal constrained hosting capacity from a load with similar characteristics was more linear, related to the size of the added load, and did not impact all model buses. Co-located capacitors were shown to accommodate demand that was beyond the baseline voltage constrained hosting capacity limits, however, the costs and benefits from this approach were found to not be 1:1 and required additional available thermal capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of airborne infrared technology to monitor building heat loss

The application of airborne infrared technology to the requirements for energy conservation in buildings was studied. Quantitative airborne data of the City of Ypsilanti, Michigan, were collected and processed to identify roof temperatures. A thermal scanner was flown at an altitude of 1,200 feet with two thermal bands 8.2-9.3 micrometers and 10.4-12.5 micrometers recorded by an analog system. Calibration was achieved by standard hot and cold plates. Using a thermal model to interpret ceiling insulation status, environmental factors were found to influence the relation between roof temperature and insulation. These include interior and sky temperatures, roofing materials, and the pitch and orientation of the roof. A follow-up mail survey established the ability to identify insulated and uninsulated houses from the airborne infrared data.

Tanis, F. J.↗