Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Ensemble Simulations on Leadership Computing Systems

Scientific productivity can be enhanced through workflow management tools, relieving large High Performance Computing (HPC) system users from the tedious tasks of scheduling and designing the complex computational execution of scientific applications. This paper presents a study on the usage of ensemble workflow tools to accelerate science using the Summit and Frontier supercomputing systems. The research aims to connect science domain simulations using Oak Ridge Leadership Computing Facility (OLCF) supercomputing platforms with ensemble workflow methods in order to accelerate HPC-enabled discovery and boost scientific impact. We present the coupling, porting and optimization of Radical-Cybertools on three applications: Chroma, NAMD and LAMMPS. The tools augment traditional HPC monolithic runs with a pilot scheduler. Lessons-learned are discussed for physics, biology and materials science applications. We discuss intrinsic limitations of coupling and porting ensemble workflow tools to applications that run on large HPC systems. The origins of technical challenges and their solutions developed during the implementation process are discussed. Data management strategies, OLCF’s policies for ensembles, and natively supported workflow tools are also summarized.

Georgiadou, Antigoni [ORNL] (ORCID:000000020977631↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Battery system management through non-linear estimation of battery state of charge

Systems, methods, and computer media for battery system management and non-linear estimation of battery state of charge are provided herein. Battery data is received for a time period over which a battery system has operated. The battery data represents the actual performance of the battery system over the time period. Sub-periods of charging or discharging can be identified in the time period. For the sub-periods of time, a curve can be fit to the battery data. Using the curves for the battery data for the sub-periods of time, an expected performance of the battery system, over a range of states-of-charge, can be determined. Operating instructions for the battery system can be provided based on the expected performance.

25 ENERGY STORAGE↗

Battery system management through non-linear estimation of battery state of charge

Systems, methods, and computer media for battery system management and non-linear estimation of battery state of charge are provided herein. Battery data is received for a time period over which a battery system has operated. The battery data represents the actual performance of the battery system over the time period. Sub-periods of charging or discharging can be identified in the time period. For the sub-periods of time, a curve can be fit to the battery data. Using the curves for the battery data for the sub-periods of time, an expected performance of the battery system, over a range of states-of-charge, can be determined. Operating instructions for the battery system can be provided based on the expected performance.

Crawford, Alasdair James↗

Photovoltaic Data Acquisition (PVDAQ) Public Datasets

The NREL PVDAQ is a large-scale time-series database containing system metadata and performance data from a variety of experimental PV sites and commercial public PV sites. The datasets are used to perform on-going performance and degradation analysis. Some of the sets can exhibit common elements that effect PV performance (e.g. soiling). The dataset consists of a series of files devoted to each of the systems and an associated set of metadata information that explains details about the system hardware and the site geo-location. Some system datasets also include environmental sensors that cover irradiance, temperatures, wind speeds, and precipitation at the site.

Array↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Scalable VQE Simulation on Leading HPC Systems

Large-scale simulations of quantum circuits pose significant challenges, especially in the context of quantum chemistry, due to the number of qubits, circuit depth, and the number of circuits needed per problem. High-performance computing (HPC) systems offer massive computational capabilities that could help overcome these obstacles. We developed a high-performance quantum circuit simulator, called NWQ-Sim, and demonstrate its capability to simulate large quantum chemistry problems on NERSC's Perlmutter supercomputer. Integrating NWQ-Sim with XACC, we have executed QPE and VQE algorithms for downfolded quantum chemistry systems at unprecedented scales. Our work demonstrates the potential of leveraging HPC resources to advance quantum chemistry and other applications of near-term quantum devices.

Wang, Meng↗

Morphotype-resolved characterization of microalgal communities in a nutrient recovery process with ARTiMiS flow imaging microscopy

Microalgae-driven nutrient recovery represents a promising technology for phosphorus removal from wastewater while simultaneously generating biomass that can be valorized to offset treatment costs. As full-scale processes come online, system parameters including biomass composition must be carefully monitored to optimize performance and prevent culture crashes. In this study, flow imaging microscopy (FIM) was leveraged to characterize microalgal community composition in near real-time at a full-scale municipal wastewater treatment plant (WWTP) in Wisconsin, USA, and population and morphotype dynamics were examined to identify relationships between water chemistry, biomass composition, and system performance. Two FIM technologies, FlowCam and ARTiMiS, were evaluated as monitoring tools. ARTiMiS provided a more accurate estimate of total system biomass, and estimates derived from particle area as a proxy for biovolume yielded better approximations than particle counts. Deep learning classification models trained on annotated image libraries demonstrated equivalent performance between FlowCam and ARTiMiS, and convolutional neural network (CNN) classifiers proved significantly more accurate when compared to feature table-based dense neural network (DNN) models. Across a two-year study period, Scenedesmus spp. appeared most important for phosphorus removal, and were negatively impacted by elevated temperatures and increase in nitrite/nitrate concentrations. Chlorella and Monoraphidium also played an important role in phosphorus removal. For both Scenedesmus and Chlorella, smaller morphological types were more often associated with better system performance, whereas larger morphotypes likely associated with stress response(s) correlated with poor phosphorus recovery rates. Furthermore, these results demonstrate the potential of FIM as a critical technology for high-resolution characterization of industrial microalgal processes.

59 BASIC BIOLOGICAL SCIENCES↗

Life-Cycle Cost and Optimization of PV Systems Based on Power Duration Curve with Variable Performance Ratio and Availability

A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.

14 SOLAR ENERGY↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Leading Edge Erosion Classification System

The leading edge erosion of wind turbine blades is a common issue that can have a range of implications for the operation and maintenance of the turbine. A variety of methods have attempted to determine the severity of erosion damage, applied in different academic, testing and in-situ settings. This paper describes the current state of the art in categorization, and the individual drivers in assessment. From this foundation, the IEA Wind Task 46 WP3 group collated key considerations from the process of categorizing erosion damage and a proposed erosion classification system was put forward. Trial assessments were performed using the initial system, which led to adjustments to the original proposition. The refined system defines discrete severity levels that concern the wind turbine blade: (1) Visual Condition (concerning blades with/without leading edge protection); (2) Mass Loss; (3) Aerodynamic Performance; and (4) Structural Integrity. The classification system presented is not intended to be a fixed entity. The Task 46 group has already identified specific challenges and opportunities that are applicable to individual use and the overall wind energy industry. The intention is for the system to evolve as improvements are identified, technology improves, and work progresses through other Task 46 activities. Several considerations and recommendations are discussed that could be applicable for future implementation of the system.

17 WIND ENERGY↗

Simulating Distributed Energy Resource Responses to Transmission System-Level Faults Considering IEEE 1547 Performance Categories on Three Major WECC Transmission Paths

This study performs a large quantity of transmission and distribution simulations for three regions in the Western Interconnection along with final transmission simulations informed by distribution simulation results. Results find that the type of ride-through implemented by distributed energy resources (DERs) is a significant factor to the overall power system response to transmission-level faults. This impact is particularly high for transmission-level faults that depress voltage levels for high numbers of substations (i.e., for cases that experience large regional voltage sags). Because of the programmed nature of the ride-through of IEEE 1547-compliant DERs, the potential for large reductions in real power injection is possible based on IEEE 1547 interpretation and specific implementation. In this study, we made a first attempt to determine the quantity of DERs affected by a variety of transmission-level faults as well as a granular response of distribution-simulated DERs to a few types of IEEE 1547-2003 interpretations and IEEE 1547-2018 voltage ride-through categories. The distribution-informed transmission studies show that the category of IEEE 1547 adherence, particularly with the new 2018 standard, can have a significant impact on the amount of DER-based generation lost following transmission-level fault events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Approach to Measure the Efficiency of Freight Transport: Freight Mobility Energy Productivity (F-MEP) Metric

Freight travel accounts for a major share of the energy consumed in the transportation sector in any country, and the United States is no exception. Understanding and modeling freight movement is critical, particularly in the context of capturing the impact of emerging technologies on freight travel and its externalities. The domain of freight modeling and forecasting is gaining pace in the recent years, but advancement in comprehensive freight performance metrics is still lagging. Conventional freight performance metrics such as truck-miles, ton-miles, or value-miles are unidimensional and aggregated in nature, making them unsuitable to accurately capture the impact of emerging transportation trends on the performance of freight systems. Addressing this research need, this paper presents the 'Freight Mobility Energy Productivity' metric to quantify freight performance of current as well as future freight systems, accounting for various costs associated with freight transport. The proposed metric was implemented using data from the Freight Analysis Framework along with other published sources, which shows intuitive results in quantifying freight performance. Further, a scenario analysis exercise was conducted to test the capability of the metric in tracking improvements in system-level freight efficiency as a result of vehicle powertrain technology improvement. Results of the scenario analysis reinforce confidence that the proposed metric can be used as a decision support tool in assessing the efficiency of existing as well as future freight trends and technologies.

25 ENERGY STORAGE↗

Aerosol-Jet Printed Transferable Millimeter-Wave Circuits

Printed millimeter wave (mmW) electronics have been of high interest in the field of communications for some time now due to the potential ability to fabricate mmW systems that utilize 3-Dimension Heterogeneous Integration (3DHI) to improve performance beyond traditional systems. Here, in this paper, a method for fabricating transferable mmW structures via aerosol-jet printing (AJP) is presented. A PDMS stamp assisted liftoff procedure is developed to separate the printed part from a rigid printing support surface and apply it to an adhesive target surface. Several microstrip (MS) line structures are demonstrated to characterize the effect of stamp transfer on the RF performance of the printed circuits. The effects of printed vias on RF probe pads and shifts in the resonant frequencies of a Beatty standard line after transfer are considered and characterized using S-parameter measurements.

42 ENGINEERING↗

Resiliency-Driven Proactive Distribution System Reconfiguration With Synchrophasor Data

Measuring and enabling resiliency of electric distribution systems with increasing weather and cyber events are important. Some of the extreme events (e.g. Earthquakes, Hurricanes) and associated paths are predicted and monitored closely in advance and allow to take pre-event proactive control actions. The Distribution Phasor Measurement Units (D-PMUs) provide new opportunities and supporting such proactive actions. Here, a synchrophasor based resiliency driven pre-event reconfiguration can ensure minimizing impact of the expected event on the power distribution system and associated performance. However, the D-PMUs will also face challenges in terms of data quality similar to the transmission PMUs. The focus of this paper is to provide data mining approaches for anomaly detection in D-PMUs and proposing resiliency-driven pre-event reconfiguration with islanding as a proactive mechanisms to minimize the impact of adverse events on system using processed synchrophasors data. Results are validated for real industrial feeders and test cases with satisfactory response

controlled islanding↗

Programming Abstractions for Managing Workflows on Tiered Storage Systems

Scientific workflows in High Performance Computing (HPC) environments are processing large amounts of data. The storage hierarchy on HPC systems is getting deeper, driven by new technologies (NVRAMs, SSDs, etc.) There is a need for new programming abstractions that allow users to seamlessly manage data at the workflow level on multi-tiered storage systems, and provide optimal workflow performance and use of storage resources. In previous work, we introduced a software architecture Managing Data on Tiered Storage for Scientific Workflows (MaDaTS) that used a Virtual Data Space (VDS) abstraction to hide the complexities of the underlying storage system while allowing users to control data management strategies. In this article, we detail the data-centric programming abstractions that allow users to manage a workflow around its data on the storage layer. The programming abstractions simplify data management for scientific workflows on multi-tiered storage systems, without affecting workflow performance or storage capacity. We measure the overheads and effectiveness introduced by the programming abstractions of MaDaTS. Our results show that these abstractions can optimally use the storage capacity in lesser capacity storage tiers, and simplify data management without adding any performance overheads.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Resilience and economics of microgrids with PV, battery storage, and networked diesel generators

Current designs and assessments of microgrids have ignored component reliability, leading to significant errors in predicting a microgrid’s performance while islanded. Existing life cycle cost studies on hybrid microgrids—which combine photovoltaics (PV), battery storage and networked emergency diesel generators—also have not identified all the potential economic opportunities. Reducing the number of emergency diesel generators through reliance on PV and battery, retail bill savings, and demand response and wholesale market revenue streams are all important. This paper provides a new statistical methodology that calculates the impact of distributed energy reliability and variability on a microgrid’s performance and a novel use of the optimization platform REopt to explore multiple cost savings and revenue streams. We examine the impacts for microgrids in California, Maryland, and New Mexico and show that a hybrid microgrid is a more resilient and cost-effective solution than a diesel-only system. Under realistic conditions, a hybrid microgrid can provide higher system reliability when islanded and have a lower life cycle cost under multiple market conditions than a traditional diesel generator-based system. The improved performance of the hybrid system is resilient to conditions experienced over the last 20 years in solar irradiance and sees little degradation in performance immediately after a hurricane. The cost savings to provide this more resilient backup power system as compared to a diesel-only microgrid are significant. The net present cost for a hybrid microgrid is 19% lower in New Mexico and 35% lower in Maryland than a diesel-only microgrid. In California, the net present cost of the hybrid microgrid is negative because, unlike a diesel-only microgrid, a hybrid microgrid has lower life cycle costs than the power costs without a microgrid.

25 ENERGY STORAGE↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗