Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

MO-DE-BRA-06: 3D Image Acquisition and Reconstruction Explained with Online Animations

Purpose: Understanding the principles of 3D imaging and image reconstruction is fundamental to the field of medical imaging. Clinicians, technologists, physicists, patients, students, and inquisitive minds all stand to benefit from greater comprehension of the supporting technologies. To help explain the basic principles of 3D imaging, we developed multi-frame animations that convey the concepts of tomographic imaging. The series of free (gif) animations are accessible online, and provide a multimedia introduction to the main concepts of image reconstruction. Methods: Text and animations were created to convey the principles of analytic tomography in CT, PET, and SPECT. Specific topics covered included: principles of sinograms/image data storage, forward projection, principles of PET acquisitions, and filtered backprojection. A total of 8 animations were created and presented for CT, PET, and digital phantom formats. In addition, a free executable is also provided to allow users to create their own tomographic animations – providing an opportunity for interaction and personalization to help foster user interest. Results: Tutorial text and animations have been posted online, freely available to view or download. The animations are in first position in a google search of “image reconstruction animations”. The website currently receives approximately 200 hits/month, from all over the world, and the usage is growing. Positive feedback has been collected from users. Conclusion: We identified a need for improved teaching tools to help visualize the (temporally variant) concepts of image reconstruction, and have shown that animations can be a useful tool for this aspect of education. Furthermore, posting animations freely on the web has shown to be a good way to maximize their impact in the community. In future endeavors, we hope to expand this animated content, to cover principles of iterative reconstruction, as well as other phenomena relating to imaging.

60 APPLIED LIFE SCIENCES↗

Interactive archives of scientific data

A focus on qualitative methods of presenting data shows that visualization provides a mechanism for browsing independent of the source of data and is an effective alternative to traditional image-based browsing of image data. To be generally applicable, such visualization methods, however, must be based upon an underlying data model with support for a broad class of data types and structures. Interactive, near-real-time browsing for data sets of interesting size today requires a browse server of considerable power. A symmetric multi-processor with very high internal and external bandwidth demonstrates the feasibility of this concept. Although this technology is likely to be available on the desktop within a few years, the increase in the size and complexity of achieved data will continue to exceed the capacity of 'worksation' systems. Hence, a higher class of performance, especially in bandwidth, will generally be required for on-demand browsing. A few experiments with differing digital compression techniques indicates that a MPEG-1 implementation within the context of a high-performance browse server (i.e., parallized) is a practical method of converting a browse product to a form suitable for network or CD-ROM distribution.

Treinish, Lloyd A.↗

A Specialized Ultrasound Protocol for NASA's Renal Stone Surveillance and Clinical Practice

INTRODUCTION Ample evidence exists on the effectiveness of ultrasound in the diagnosis of kidney stones. However, terrestrial practice is mostly concerned with diagnosis of clinically significant urolithiasis. Adapting this non-irradiating, low-cost imaging modality for the asymptomatic astronaut population offers high-sensitivity screening and limits their career radiation dose. METHODS NASA developed a novel ultrasound-based detection and surveillance protocol to identify, categorize, and monitor mineralized renal material (MRM) in astronauts. The term MRM was developed to denote abnormal, presumably calcified, focal material of unknown clinical significance in the kidneys. Sonographic criteria for MRMs include measurable echogenic foci, their detectability in multiple, designated imaging plains, posterior shadowing, and “twinkle” pattern visualized in Color Doppler and/or demonstrated in Spectral Doppler modes. The mere discovery of an MRM does not trigger further imaging or intervention, unless the affected crewmember is mission-assigned, or the MRM meets actionable criteria based on size, location, and sonographic characteristics. If the threshold is met, the crew surgeon is notified, and additional diagnostic imaging and urology consultation are considered. RESULTS In total, 73 individuals have been scanned using our specialized methods, 60 have had more than one study done. As of April 2023, 282 total studies have been performed. So far, over 30 pairs of pre-and postflight studies have been obtained, and the findings are presented elsewhere in this panel. DISCUSSION A surveillance program was initiated nine years ago to screen asymptomatic members of the astronaut corps for renal calcifications, from their initial hiring, through their mission timeframes, and throughout their career. The goal is to reduce the probability that an astronaut will fly with a renal stone that may become symptomatic. This also gives NASA the information it needs to improve screening criteria for future long-duration crewed missions.

H Lyons↗

3D visualization of polymer nanostructure

Soft materials and structured polymers are extremely useful nanotechnology building blocks. Block copolymers, in particular, have served as 2D masks for nanolithography and 3D scaffolds for photonic crystals, nanoparticle fabrication, and solar cells. F or many of these applications, the precise 3 dimensional structure and the number and type of defects in the polymer is important for ultimate function. However, directly visualizing the 3D structure of a soft material from the nanometer to millimeter length scales is a significant technical challenge. Here, we propose to develop the instrumentation needed for direct 3D structure determination at near nanometer resolution throughout a nearly millimeter-cubed volume of a soft, potentially heterogeneous, material. This new capability will be a valuable research tool for LANL missions in chemistry, materials science, and nanoscience. Our approach to soft materials visualization builds upon exciting developments in super-resolution optical microscopy that have occurred over the past two years. To date, these new, truly revolutionary, imaging methods have been developed and almost exclusively used for biological applications. However, in addition to biological cells, these super-resolution imaging techniques hold extreme promise for direct visualization of many important nanostructured polymers and other heterogeneous chemical systems. Los Alamos has a unique opportunity to lead the development of these super-resolution imaging methods for problems of chemical rather than biological significance. While these optical methods are limited to systems transparent to visible wavelengths, we stress that many important functional chemicals such as polymers, glasses, sol-gels, aerogels, or colloidal assemblies meet this requirement, with specific examples including materials designed for optical communication, manipulation, or light-harvesting Our Research Goals are: (1) Develop the instrumentation necessary for imaging materials at {approx} 10 nm resolution over hundreds of microns in 3 spatial dimensions. Super-resolution microcopy methods based upon single molecule localization were originally limited to 2D slices. Recent advances in this field have extended these methods to three dimensions. However, the 3D rendering was limited to viewing sparsely labeled cellular structures over a z-depth of less than 1 micron. Our first goal is to extend super resolution microscopy to z-depths of hundreds of microns. This substantial improvement is needed to image polymer nanostructure over functionally relevant length scales. (2) Benchmark this instrument by studying the 3D nanostructure of diblock co-polymer morphologies. We will test and benchmark our instrument by imaging fluorescently labeled diblock copolymers, molecules that self-assemble into a variety of 3D nano-structures. We reiterate these polymers are useful for a variety of applications ranging from lithography to light harvesting.

36 MATERIALS SCIENCE↗

Model Cortical Association Fields Account for the Time Course and Dependence on Target Complexity of Human Contour Perception

Can lateral connectivity in the primary visual cortex account for the time dependence and intrinsic task difficulty of human contour detection? To answer this question, we created a synthetic image set that prevents sole reliance on either low-level visual features or high-level context for the detection of target objects. Rendered images consist of smoothly varying, globally aligned contour fragments (amoebas) distributed among groups of randomly rotated fragments (clutter). The time course and accuracy of amoeba detection by humans was measured using a two-alternative forced choice protocol with self-reported confidence and variable image presentation time (20-200 ms), followed by an image mask optimized so as to interrupt visual processing. Measured psychometric functions were well fit by sigmoidal functions with exponential time constants of 30-91 ms, depending on amoeba complexity. Key aspects of the psychophysical experiments were accounted for by a computational network model, in which simulated responses across retinotopic arrays of orientation-selective elements were modulated by cortical association fields, represented as multiplicative kernels computed from the differences in pairwise edge statistics between target and distractor images. Comparing the experimental and the computational results suggests that each iteration of the lateral interactions takes at least 37.5 ms of cortical processing time. Our results provide evidence that cortical association fields between orientation selective elements in early visual areas can account for important temporal and task-dependent aspects of the psychometric curves characterizing human contour perception, with the remaining discrepancies postulated to arise from the influence of higher cortical areas.

59 BASIC BIOLOGICAL SCIENCES↗

TH-C-17A-03: Dynamic Visualization and Dosimetry of IMRT and VMAT Treatment Plans by Video-Rate Imaging of Cherenkov Radiation in Pure Water

Purpose: A novel optical dosimetry technique for the QA and verification of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) radiotherapy plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: An intensified CCD camera (ICCD) was used to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank. The ICCD acquisition was gated to the Linac, operated for single pulse imaging, and binned to a resolution of 512×512 pixels. The resulting videos were analyzed temporally for regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR) and summed to obtain an overall light distribution, which was compared to the expected dose distribution from the TPS using a gammaindex analysis. Results: The chosen camera settings resulted in data at 23.5 frames per second. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.2% and 95.6% agreement between the light distribution and expected TPS dose distribution based upon a 3% / 3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans respectively. Conclusion: The results from this initial study demonstrate the first documented use of Cherenkov radiation for optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications. NIH R01CA109558 and R21EB017559.

07 ISOTOPE AND RADIATION SOURCES↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Spatial resolution and the geologic interpretation of Martian morphology - Implications for subsurface volatiles

Viking Orbiter images of the Acheron Fossae on Mars are presented and analyzed, with an emphasis on the impact of image resolution on the interpretation. High-resolution (less than 10 m/pixel) images reveal small mounds which can be interpreted as aeolian dunes, but these features are not evident on images with resolution of 50 m/pixel or greater. Also reported are the results of a visual inspection of 527 usable high-resolution images: it is found that all of the morphological features identified can arise in the absence of subsurface volatiles.

Zimbelman, James R.↗

A VLSI design for universal noiseless coding

The practical, noiseless and efficient data-compression technique presented involves a conceptual VLSI design which is capable of meeting real-time processing rates and meets low-power, low-weight, and small-volume requirements. This form of data compression is applicable to image data compression aboard future low-budget spaceflight missions, for such instruments as visual-IR mapping spectrometers and high-resolution imaging spectrometers.

Lee, Jun-Ji↗

3D Localization of Defects in Facility Inspection

Wind tunnels are crucial facilities that support the aerospace industry. However, these facilities are large, complex, and pose unique maintenance and inspection requirements. Manual inspections to identify defects such as cracks, missing fasteners, leaks, and foreign objects are important but labor and schedule intensive. Our goal is to utilize small Unmanned Aircraft Systems (sUAS) and computer vision-based analysis to automate the inspection of the interior and exterior of NASA’s critical wind tunnel facilities. We detect missing fasteners as our defect class, and detect existing fasteners to provide potential future missing fastener sites for preventative maintenance. These detections are done on both 2D raw images and in 3D space to provide a visual reference and real world location to facilitate repairs. A dataset was created consisting of images taken along a grid-like pattern of an interior tunnel section in the AEDC National Full-Scale Aerodynamics Complex (NFAC) at NASA Ames Research Center. Our method uses object detection to create image level bounding boxes of the fasteners and missing fasteners, then uses photogrammetry to create a mapping from 2D image locations to 3D real world locations. The image level bounding boxes and the 2D to 3D mapping are then combined to determine the 3D location of the defects. We describe the data collection, photogrammetry, and computer vision techniques used for object detection as well as a quantitative analysis of the method.

Small Unmanned Aircraft Systems (sUAS)↗

Monitoring external beam radiotherapy using real-time beam visualization

Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Induced Damage to Microstructure of Parotid Gland: Evaluation Using High-Resolution Magnetic Resonance Imaging

Purpose: To elucidate the radiation-induced damage to the microstructure of the parotid gland using high-resolution magnetic resonance imaging. Methods and Materials: High-resolution magnetic resonance imaging of the parotid gland was performed before radiotherapy (RT) and during the RT period or {<=}3 weeks after RT completion for 12 head-and-neck cancer patients using a 1.5-T scanner with a microscopy coil. The maximal cross-sectional area of the gland was evaluated, and changes in the internal architecture of the gland were assessed both visually and quantitatively. Results: Magnetic resonance images were obtained at a median parotid gland dose of 36 Gy (range, 11-64). According to the quantitative analysis, the maximal cross-sectional area of the gland was reduced, the width of the main duct was narrowed, and the intensity ratio of the main duct lumen to background was significantly decreased after RT (p <.0001). According to the visual assessment, the width of the main duct tended to narrow and the contrast of the duct lumen tended to be decreased, but no significant differences were noted. The visibility of the duct branches was unclear in 10 patients (p = .039), and the septum became dense in 11 patients (p = .006) after RT. Conclusion: High-resolution magnetic resonance imaging is a noninvasive method of evaluating radiation-induced changes to the internal architecture of the parotid gland. Morphologic changes in the irradiated parotid gland were demonstrated during the RT course even when a relatively small dose was delivered to the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic information extraction from neutron radiography imaging to estimate axial fuel expansion in $\mathrm{EBR-II}$

Approximately 130,000 metal fuel pins were irradiated in the Experimental Breeder Reactor II (EBR-II) during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed to characterize fuel behavior, like fuel swelling. However, due to the lack of technology or resources, many of the images have not been processed or were processed manually through visual examination. This paper represents first-attempt to develop an image processing algorithm capable of automatically extracting information regarding the degree of fuel swelling from neutron radiography imaging. The algorithm was applied to 120 images of three different metallic fuel pin compositions—U-10Zr, U-8Pu-10Zr, and U-19Pu-10Zr. The algorithm performs operations of image intensity adjustment, image binarization, region finding, and labeling to extract information about fuel swelling. The average growth for U-10Zr was found to be 8.49% with 95% Confidence Interval (CI) [8.33 –8.66%], for U-8Pu-10Zr — 7.50% with 95% CI [7.23 – 7.78%], and for U-19Pu-10Zr — 3.15%, with 95% CI [2.40 – 3.91%]. The results obtained by applying this automatic image processing algorithm are consistent with previously reported studies of the same types of fuels. The automatic image processing algorithm will be expanded to include thousands of available neutron radiography images and different types of fuels to investigate empirical dependencies of fuel swelling, which can be subsequently applied to advanced fuel modeling. Results from this study can later be compared to BISON simulations to further benchmark modeling efforts and develop assessment cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced magneto-optical microscopy: Imaging from picoseconds to centimeters - imaging spin waves and temperature distributions (invited)

Recent developments in the observation of magnetic domains and domain walls by wide-field optical microscopy based on the magneto-optical Kerr, Faraday, Voigt, and Gradient effect are reviewed. Emphasis is given to the existence of higher order magneto-optical effects for advanced magnetic imaging. Fundamental concepts and advances in methodology are discussed that allow for imaging of magnetic domains on various length and time scales. Time-resolved imaging of electric field induced domain wall rotation is shown. Visualization of magnetization dynamics down to picosecond temporal resolution for the imaging of spin-waves and magneto-optical multi-effect domain imaging techniques for obtaining vectorial information are demonstrated. Beyond conventional domain imaging, the use of a magneto-optical indicator technique for local temperature sensing is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shuttle Entry Imaging Using Infrared Thermography

During the Columbia Accident Investigation, imaging teams supporting debris shedding analysis were hampered by poor entry image quality and the general lack of information on optical signatures associated with a nominal Shuttle entry. After the accident, recommendations were made to NASA management to develop and maintain a state-of-the-art imagery database for Shuttle engineering performance assessments and to improve entry imaging capability to support anomaly and contingency analysis during a mission. As a result, the Space Shuttle Program sponsored an observation campaign to qualitatively characterize a nominal Shuttle entry over the widest possible Mach number range. The initial objectives focused on an assessment of capability to identify/resolve debris liberated from the Shuttle during entry, characterization of potential anomalous events associated with RCS jet firings and unusual phenomenon associated with the plasma trail. The aeroheating technical community viewed the Space Shuttle Program sponsored activity as an opportunity to influence the observation objectives and incrementally demonstrate key elements of a quantitative spatially resolved temperature measurement capability over a series of flights. One long-term desire of the Shuttle engineering community is to calibrate boundary layer transition prediction methodologies that are presently part of the Shuttle damage assessment process using flight data provided by a controlled Shuttle flight experiment. Quantitative global imaging may offer a complementary method of data collection to more traditional methods such as surface thermocouples. This paper reviews the process used by the engineering community to influence data collection methods and analysis of global infrared images of the Shuttle obtained during hypersonic entry. Emphasis is placed upon airborne imaging assets sponsored by the Shuttle program during Return to Flight. Visual and IR entry imagery were obtained with available airborne imaging platforms used within DoD along with agency assets developed and optimized for use during Shuttle ascent to demonstrate capability (i.e., tracking, acquisition of multispectral data, spatial resolution) and identify system limitations (i.e., radiance modeling, saturation) using state-of-the-art imaging instrumentation and communication systems. Global infrared intensity data have been transformed to temperature by comparison to Shuttle flight thermocouple data. Reasonable agreement is found between the flight thermography images and numerical prediction. A discussion of lessons learned and potential application to a potential Shuttle boundary layer transition flight test is presented.

Horvath, Thomas↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗