Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Complete spectroscopy in the attosecond regime

Harnessing light waveforms at attosecond time scales provides information of the structure and dynamics of matter on it's natural time scales. For this reason attosecond metrology has been at the forefront of the optical sciences for more than a decade, and it represents the latest time-domain frontier of the quantum world. Attosecond light pulses are commonly generated using higher-order harmonic generation (HHG) , a process capable of generating XUV coherent pulses. In addition to generate attosecond pulses, HHG can be used to study the structure and dynamics of atoms and molecules by analyzing the spectral content of the XUV pulses. This approach is known as HHG spectroscopy and it provides a coherent, time-dependent approach to study structure and dynamics in the quantum world. In this proposal we will generate harmonics from two optical foci produced by a system of a two-dimensional spatial light modulator (SLM) and a lens. In the far eld the train of attosecond pulses will interfere creating harmonic-dependent fringes. The position of such fringes is a direct measurement of the relative phase between the two foci and they also carry information about the quantum state of the target atom or molecule. Therefore, by measuring the amplitude and relative phase of the emitted harmonics we will have access to both, the amplitude and phase of the dipole moments of the studied target. Because the two beams are completely indistinguishable from each other up to a few millimeters from the focus, both driving pulses share the exact beam path. So far we have measured a jitter of 700 zeptoseconds with a 12.5 attosecond resolution in the delay control of the two foci. These two time scales represent some of the best time controls ever achieved to date.

74 ATOMIC AND MOLECULAR PHYSICS↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Angle-resolved polarized Raman spectroscopy study of phosphorene nanoribbons

We present a systematic angle-resolved polarized Raman spectroscopy (ARPRS) study of black phosphorus (BP) nanostructures formed via electrochemical sodium- and lithium-ion intercalation. Sodium intercalation leads to bundles of densely packed, highly uniform phosphorene nanoribbons (PNRs) separated by parallel amorphous channels, whereas lithium intercalation results in shorter, irregular nanoribbon-like segments with lower aspect ratios. In both cases, six additional Raman peaks (P1–P6) appear alongside the three primary Raman-active modes of BP (A$^{1}_{g}$, B 2g , and A$^{2}_{g}$). These peaks are attributed to the amorphous regions, as confirmed by their isotropic angular dependence in ARPRS measurements. The three BP modes show pronounced angular variations that differ significantly between the two intercalated samples. In sodium-intercalated BP, A$^{1}_{g}$ and A$^{2}_{g}$ modes retain a dumbbell-like angular dependence under parallel polarization with enhanced anisotropy and reduced symmetry under crossed polarization. At the same time, the B 2g mode transitions from four-lobed (cloverleaf) polar plot to a butterfly-like one. In contrast, lithium-intercalated BP exhibits weaker anisotropy and less distinct angular polar plots for all three modes. These differences reflect the sensitivity of phonon behavior to underlying nanostructure morphology. The vibrational frequencies density of states (FDOS) calculations attribute the B 2g mode transformation to phonon band folding and mode mixing in PNRs. This study demonstrates the power of ARPRS in probing phonon-structure relationships and highlights the influence of edge geometry and quantum confinement on phonon dispersion in PNRs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Early Diagnosis of Fibromyalgia Using Surface-Enhanced Raman Spectroscopy Combined with Chemometrics

Fibromyalgia (FM) is a chronic muscle pain disorder that shares several clinical features with other related rheumatologic disorders. This study investigates the feasibility of using surface-enhanced Raman spectroscopy (SERS) with gold nanoparticles (AuNPs) as a fingerprinting approach to diagnose FM and other rheumatic diseases such as rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), osteoarthritis (OA), and chronic low back pain (CLBP). Blood samples were obtained on protein saver cards from FM (n = 83), non-FM (n = 54), and healthy (NC, n = 9) subjects. A semi-permeable membrane filtration method was used to obtain low-molecular-weight fraction (LMF) serum of the blood samples. SERS measurement conditions were standardized to enhance the LMF signal. An OPLS-DA algorithm created using the spectral region 750 to 1720 cm -1 enabled the classification of the spectra into their corresponding FM and non-FM classes (Rcv > 0.99) with 100% accuracy, sensitivity, and specificity. The OPLS-DA regression plot indicated that spectral regions associated with amino acids were responsible for discrimination patterns and can be potentially used as spectral biomarkers to differentiate FM and other rheumatic diseases. This exploratory work suggests that the AuNP SERS method in combination with OPLS-DA analysis has great potential for the label-free diagnosis of FM.

60 APPLIED LIFE SCIENCES↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

M-Edge Spectroscopy of Transition Metals: Principles, Advances, and Applications

M-edge X-ray absorption spectroscopy (XAS), which probes 3p→3d transitions in first-row transition metals, provides detailed insights into oxidation states, spin-states, and local electronic structure with high element and orbital specificity. Operating in the extreme ultraviolet (XUV) region, this technique provides sharp multiplet-resolved features with high sensitivity to ligand field and covalency effects. Compared to K- and L-edge XAS, M-edge spectra exhibit significantly narrower full widths at half maximum (typically 0.3–0.5 eV versus >1 eV at the L-edge and >1.5–2 eV at the K-edge), owing to longer 3p core-hole lifetimes. M-edge measurements are also more surface-sensitive due to the lower photon energy range, making them particularly well-suited for probing thin films, interfaces, and surface-bound species. The advent of tabletop high-harmonic generation (HHG) sources has enabled femtosecond time-resolved M-edge measurements, allowing direct observation of ultrafast photoinduced processes such as charge transfer and spin crossover dynamics. This review presents an overview of the fundamental principles, experimental advances, and current theoretical approaches for interpreting M-edge spectra. We further discuss a range of applications in catalysis, materials science, and coordination chemistry, highlighting the technique’s growing impact and potential for future studies.

M-edge XANES↗

The Effect of Intensity Fluctuations on Sequential X-ray Photon Correlation Spectroscopy at the X-ray Free Electron Laser Facilities

How materials evolve at thermal equilibrium and under external excitations at small length and time scales is crucial to the understanding and control of material properties. X-ray photon correlation spectroscopy (XPCS) at X-ray free electron laser (XFEL) facilities can in principle capture dynamics of materials that are substantially faster than a millisecond. However, the analysis and interpretation of XPCS data is hindered by the strongly fluctuating X-ray intensity from XFELs. Here we examine the impact of pulse-to-pulse intensity fluctuations on sequential XPCS analysis. We show that the conventional XPCS analysis can still faithfully capture the characteristic time scales, but with substantial decrease in the signal-to-noise ratio of the g2 function and increase in the uncertainties of the extracted time constants. We also demonstrate protocols for improving the signal-to-noise ratio and reducing the uncertainties.

36 MATERIALS SCIENCE↗

Determination of Thermal Damage Threshold in THz Photomixers Using Raman Spectroscopy

The increase of device lifetime and reliability of THz photomixers will play an essential role in their possible future application. Therefore, their optimal work conditions/operation range, i.e., the maximal incident optical power should be experimentally estimated. We fabricated and tested THz photomixer devices based on nitrogen-implanted GaAs integrated with a Bragg reflector. Raman spectroscopy was applied to investigate the material properties and to disclose any reversible or irreversible material changes. The results indicate that degradation effects in the photomixer structures/material could be avoided if the total optical power density does not exceed levels of about 0.7 mW/µm 2 for 100 min of operation. Furthermore, the investigations performed during 1000 min of optical exposure on the photomixer devices’ central region comprising interdigitated metal-semiconductor-metal (MSM) structures suggest a reversible “curing” mechanism if the power density level of ~0.58 mW/µm 2 is not exceeded. Long-term operation (up to 1000 h) reveals that the photomixer structures can withstand an average optical power density of up to ~0.4 mW/µm 2 without degradation when biased at 10 V. Besides the decrease of the position of the A1g (LO) Raman mode from ~291 cm -1 down to ~288 cm -1 with increasing optical power density and operation time, broad Raman modes evolve at about 210 cm -1 , which can be attributed to degradation effects in the active photomixer/MSM area. In addition, the performed carrier lifetime and photomixer experiments demonstrated that these structures generated continuous wave sub-THz radiation efficiently as long as their optimal work conditions/operation range were within the limits established by our Raman studies.

36 MATERIALS SCIENCE↗

Investigation of the High-Pressure Behaviors of Amblygonite by Single-Crystal X-ray Diffraction, Raman Spectroscopy, and DFT Calculations

In the present study, we extensively explored the high-pressure behaviors and vibrational properties of amblygonite LiAlPO 4 F with elevated pressures up to 34.3 GPa based on single-crystal X-ray diffraction measurements, Raman spectroscopy, and DFT calculations. The compressibility and elastic properties of amblygonite were determined first. Specifically, the obtained isothermal bulk modulus of LiAlPO 4 F is 128(4) GPa and the triclinic phase exhibited anisotropic compression with axial compressibility β c > β a > β b with a ratio of 1.11:1.00:1.20. The Raman spectra showed no indication of phase transformation and were used to obtained mode Grüneisen parameters. The average Grüneisen parameter for PO 4 tetrahedral sites was smaller than for the LiO 4 F sites. Our results provide new insights into the phase stability and elastic properties of lithium-fluorite granites at extreme conditions.

36 MATERIALS SCIENCE↗

Light-Induced Charge Separation in Photosystem I from Different Biological Species Characterized by Multifrequency Electron Paramagnetic Resonance Spectroscopy

Photosystem I (PSI) serves as a model system for studying fundamental processes such as electron transfer (ET) and energy conversion, which are not only central to photosynthesis but also have broader implications for bioenergy production and biomimetic device design. In this study, we employed electron paramagnetic resonance (EPR) spectroscopy to investigate key light-induced charge separation steps in PSI isolated from several green algal and cyanobacterial species. Following photoexcitation, rapid sequential ET occurs through either of two quasi-symmetric branches of donor/acceptor cofactors embedded within the protein core, termed the A and B branches. Using high-frequency (130 GHz) time-resolved EPR (TR-EPR) and deuteration techniques to enhance spectral resolution, we observed that at low temperatures prokaryotic PSI exhibits reversible ET in the A branch and irreversible ET in the B branch, while PSI from eukaryotic counterparts displays either reversible ET in both branches or exclusively in the B branch. Furthermore, we observed a notable correlation between low-temperature charge separation to the terminal [4Fe-4S] clusters of PSI, termed F A and F B , as reflected in the measured F A /F B ratio. These findings enhance our understanding of the mechanistic diversity of PSI’s ET across different species and underscore the importance of experimental design in resolving these differences. Though further research is necessary to elucidate the underlying mechanisms and the evolutionary significance of these variations in PSI charge separation, this study sets the stage for future investigations into the complex interplay between protein structure, ET pathways, and the environmental adaptations of photosynthetic organisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Competitive Adsorption of Ionic Liquids Versus Friction Modifier and Anti-Wear Additive at Solid/Lubricant Interface—Speciation with Vibrational Sum Frequency Generation Spectroscopy

A modern lubricant contains various additives with different functionalities and the interactions or reactions between these additives could induce synergistic or antagonistic effects in tribological performance. In this study, sum frequency generation (SFG) spectroscopy was used to investigate competitive adsorption of lubricant additives at a solid/base oil interface. A silica substrate was used as a model solid surface. The lubricant additives studied here included two oil-soluble ionic liquids (ILs, [N888H][DEHP] and [P8888][DEHP]), an antiwear additive (secondary ZDDP), an organic friction modifier (OFM), and a dispersant (PIBSI). Our results showed that for mixtures of ZDDP and IL in a base oil (PAO4), the silica surface is dominated by the IL molecules. In the cases of base oils containing OFM and IL, the silica/lubricant interface is dominated by OFM over [N888H][DEHP], while it is preferentially occupied by [P8888][DEHP] over OFM. The presence of PIBSI in the mixture of PAO4 and IL leads to the formation of a mixed surface layer at the silica surface with PIBSI as a major component. The SFG results in this investigation provide fundamental insights that are helpful to design the formulation of new lubricant additives of desired properties.

25 ENERGY STORAGE↗

Charge Transport Characteristics of Molecular Electronic Junctions Studied by Transition Voltage Spectroscopy

The field of molecular electronics is prompted by tremendous opportunities for using a single-molecule and molecular monolayers as active components in integrated circuits. Until now, a wide range of molecular devices exhibiting characteristic functions, such as diodes, transistors, switches, and memory, have been demonstrated. However, a full understanding of the crucial factors that affect charge transport through molecular electronic junctions should yet be accomplished. Remarkably, recent advances in transition voltage spectroscopy (TVS) elucidate that it can provide key quantities for probing the transport characteristics of the junctions, including, for example, the position of the frontier molecular orbital energy relative to the electrode Fermi level and the strength of the molecule–electrode interactions. These parameters are known to be highly associated with charge transport behaviors in molecular systems and can then be used in the design of molecule-based devices with rationally tuned electronic properties. This article highlights the fundamental principle of TVS and then demonstrates its major applications to study the charge transport properties of molecular electronic junctions.

36 MATERIALS SCIENCE↗

Compositionally Complex Alloys: Some Insights from Photoemission Spectroscopy

Photoemission spectroscopy (PES) is an underrepresented part of current and past studies of compositionally complex alloys (CCA) such as high-entropy alloys (HEA) and their derivatives. PES studies are very important for understanding the electronic structure of materials, and are therefore essential in some cases for a correct description of the intrinsic properties of CCAs. Here, we present several examples showing the importance of PES. First, we show how the difference between the split-band structure and the common-band structure of the valence band (VB), observed by PES, can explain a range of properties of CCAs and alloys in general. A simple description of the band crossing in CCAs composed from the early and late transition metals showing a split band is discussed. We also demonstrate how a high-accuracy PES study can determine the variation in the density of states at the Fermi level as a function of Cu content in Ti-Zr-Nb-Ni-Cu metallic glasses. Finally, the first results of an attempt to single out the contributions of particular constituents in Cantor-type alloys to their VBs are presented. The basic principles of PES, the techniques employed in studies presented, and some issues associated with PES measurements are also described.

36 MATERIALS SCIENCE↗

Biophysical Characterization of Membrane Proteins Embedded in Nanodiscs Using Fluorescence Correlation Spectroscopy

Proteins embedded in biological membranes perform essential functions in all organisms, serving as receptors, transporters, channels, cell adhesion molecules, and other supporting cellular roles. These membrane proteins comprise ~30% of all human proteins and are the targets of ~60% of FDA-approved drugs, yet their extensive characterization using established biochemical and biophysical methods has continued to be elusive due to challenges associated with the purification of these insoluble proteins. In response, the development of nanodisc techniques, such as nanolipoprotein particles (NLPs) and styrene maleic acid polymers (SMALPs), allowed membrane proteins to be expressed and isolated in solution as part of lipid bilayer rafts with defined, consistent nanometer sizes and compositions, thus enabling solution-based measurements. Fluorescence correlation spectroscopy (FCS) is a relatively simple yet powerful optical microscopy-based technique that yields quantitative biophysical information, such as diffusion kinetics and concentrations, about individual or interacting species in solution. Here, we first summarize current nanodisc techniques and FCS fundamentals. We then provide a focused review of studies that employed FCS in combination with nanodisc technology to investigate a handful of membrane proteins, including bacteriorhodopsin, bacterial division protein ZipA, bacterial membrane insertases SecYEG and YidC, Yersinia pestis type III secretion protein YopB, yeast cell wall stress sensor Wsc1, epidermal growth factor receptor (EGFR), ABC transporters, and several G protein-coupled receptors (GPCRs).

59 BASIC BIOLOGICAL SCIENCES↗

Monitoring Xenon Capture in a Metal Organic Framework Using Laser-Induced Breakdown Spectroscopy

Molten salt reactor operation will necessitate circulation of a cover gas to remove certain evolved fission products and maintain an inert atmosphere. The cover gas leaving the reactor core is expected to contain both noble and non-noble gases, aerosols, volatile species, tritium, and radionuclides and their daughters. To remove these radioactive gases, it is necessary to develop a robust off-gas system, along with novel sensors to monitor the gas stream and the treatment system performance. In this study, a metal organic framework (MOF) was engineered for the capture of Xe, a major contributor to the off-gas source term. The engineered MOF column was tested with a laser-induced breakdown spectroscopy (LIBS) sensor for noble gas monitoring. The LIBS sensor was used to monitor breakthrough tests with various Xe, Kr, and Ar mixtures to determine the Xe selectivity of the MOF column. This study offers an initial demonstration of the feasibility of monitoring off-gas treatment systems using a LIBS sensor to aid in the development of new capture systems for molten salt reactors.

47 OTHER INSTRUMENTATION↗

Topaz, a Potential Volatile-Carrier in Cold Subduction Zone: Constraint from Synchrotron X-ray Diffraction and Raman Spectroscopy at High Temperature and High Pressure

The equation of state and stability of topaz at high-pressure/high-temperature conditions have been investigated by in situ synchrotron X-ray diffraction (XRD) and Raman spectroscopy in this study. No phase transition occurs on topaz over the experimental pressure–temperature ($P-T$) range. The pressure–volume data were fitted by the third-order Birch–Murnaghan equation of state (EoS) with the zero-pressure unit–cell volume V 0 = 343.86 (9) Å 3 , the zero-pressure bulk modulus K 0 = 172 (3) GPa, and its pressure derivative K’ 0 = 1.3 (4), while the obtained K 0 = 155 (2) GPa when fixed K’ 0 = 4. In the pressure range of 0–24.4 GPa, the vibration modes of in-plane bending OH-groups for topaz show non-linear changes with the increase in pressure, while the other vibration modes show linear changes. Moreover, the temperature–volume data were fitted by Fei’s thermal equation with the thermal expansion coefficient α 300 = 1.9 (1) × 10 –5 K –1 at 300 K. Finally, the $P-T$ stability of topaz was studied by a synchrotron-based single-crystal XRD at simultaneously high $P-T$ conditions up to ~10.9 GPa and 700 K, which shows that topaz may maintain a metastable state at depths above 370 km in the upper mantle along the coldest subducting slab geotherm. Thus, topaz may be a potential volatile-carrier in the cold subduction zone. It can carry hydrogen and fluorine elements into the deep upper mantle and further affect the geochemical behavior of the upper mantle.

36 MATERIALS SCIENCE↗