Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Modelling CN Zeeman effect observations of the envelopes of a low-mass protostellar disc and a massive protostar

We use the POLARIS radiative transfer code to produce simulated circular polarization Zeeman emission maps of the cyanide (CN) J = 1–0 molecular line transition for two types of protostellar envelope magnetohydrodynamic simulations. Our first model is a low-mass disc envelope system (box length L = 200 au), and our second model is the envelope of a massive protostar (L = 104 au) with a protostellar wind and a CN-enhanced outflow shell. We compute the velocity-integrated Stokes I and V, as well as the implied V/I polarization percentage, for each detector pixel location in our simulated emission maps. Our results show that both types of protostellar environments are in principle accessible with current circular polarization instruments, with each containing swaths of envelope area that yield percentage polarizations that exceed the 1.8 percent nominal sensitivity limit for circular polarization experiments with the Atacama Large Millimeter/submillimeter Array. In both systems, high-polarization (≳1.8 percent) pixels tend to lie at an intermediate distance away from the central star and where the line-centre opacity of the CN emission is moderately optically thin (τLC ~ 0.1–1). Furthermore, our computed V/I values scale roughly with the density-weighted mean line-of-sight magnetic field strength, indicating that Zeeman observations can effectively diagnose the strength of envelope-scale magnetic fields. We also find that pixels with large V/I are preferentially co-located where the absolute value of the velocity-integrated V is also large, suggesting that locations with favourable percentage polarization are also favourable in terms of raw signal.

79 ASTRONOMY AND ASTROPHYSICS↗

New Physics in the Hot Electron Furnace (Final Report)

The primary purpose of this award was experiments and simulations related to the idea of a ‘Hot Electron Furnace’ where nonlocal heat transport would allow unique new experimental opportunities at x-ray free electron lasers. The period of this award included beamtime at the MEC endstation of the LCLS, and the execution of those experiments was a primary goal. Unfortunately, the beamtime had limited success due to (1) inability of the LCLS to deliver the expected two-color operations mode, and (2) failure of the MEC endstation’s own software to save the cavity timing data that would have allowed inference of time delays for the few hours when two-color mode briefly operated. The beamtime was then switched to operate in single-color (one pulse) mode, and studies were performed of x-ray heating and probe, simultaneously. Two interesting manuscripts are finally near submission, having been delayed by student graduations, need for collaborator simulations of x-ray heating processes, and then COVID. I am hopeful that they will soon be submitted (especially the paper on x-ray heating of MgO) because one of the principal students involved has returned from industry to take a postdoc position at SLAC. Below, we first list all publications and other work products (including the two that are nearing submission) and then summarize several outcomes from this effort. During the term of this award three UW physics graduate students were at least partially supported, and all three received their Ph.D.’s with significant components of their supported work in the dissertation.

47 OTHER INSTRUMENTATION↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

ARMADA. I. Triple Companions Detected in B-type Binaries α Del and ν Gem

Ground-based optical long-baseline interferometry has the power to measure the orbits of close binary systems at ∼10 μas precision. This precision makes it possible to detect “wobbles” in the binary motion due to the gravitational pull from additional short-period companions. We started the ARrangement for Micro-Arcsecond Differential Astrometry (ARMADA) survey with the Michigan Infra-Red Combiner (MIRC)/MIRC-X instrument at the Center for High Angular Resoloution Astronomy (CHARA) array for the purpose of detecting giant planets and stellar companions orbiting individual stars in binary systems. We describe our observations for the survey, and introduce the wavelength calibration scheme that delivers precision at the tens of microarcseconds level for <02 binaries. We test our instrument performance on a known triple system, κ Peg, and show that our survey is delivering a factor of 10 better precision than previous similar surveys. We present astrometric detections of tertiary components to two B-type binaries: a 30 day companion to α Del, and a 50 day companion to ν Gem. We also collected radial velocity data for α Del with the Tennessee State University Automated Spectroscopic Telescope at Fairborn Observatory. We are able to measure the orbits and masses of all three components in these systems. We find that the previously published radial velocity orbit for the inner pair of ν Gem is not consistent with our visual orbit. The precision achieved for these orbits suggests that our ARMADA survey will be successful at discovering new compact triple systems to A/B-type binary systems, leading to better statistics of hierarchical system architectures and formation history.

47 OTHER INSTRUMENTATION↗

Ion Beam Figuring System for Synchrotron X-Ray Mirrors Achieving Sub-0.2-µrad and Sub-0.5-nm Root Mean Square

Abstract Optics with high-precision height and slope are increasingly desired in numerous industrial fields. For instance, Kirkpatrick–Baez (KB) mirrors play an important role in synchrotron X-ray applications. A KB system is composed of two aspherical, grazing-incidence mirrors used to focus an X-ray beam. The fabrication of KB mirrors is challenging due to the aspherical departure of the mirror surfaces from base geometries and the high-quality requirements for slope and height residuals. In this paper, we present the process of manufacturing an elliptical cylinder KB mirror using our in-house-developed ion beam figuring (IBF) and metrology technologies. First, the key aspects of figuring and finishing processes with IBF are illustrated in detail. The effect of positioning error on the convergence of the residual slope error is highlighted and compensated. Finally, inspection and cross-validation using different metrology instruments are performed and used as the final validation of the mirror. Results confirm that relative to the requested off-axis ellipse, the mirror has achieved 0.15-µrad root mean square (RMS) and 0.36-nm RMS residual slope and height errors, respectively, while maintaining the initial 0.3-nm RMS microroughness.

36 MATERIALS SCIENCE↗

A miniature multi-anvil apparatus using diamond as anvils—MDAC: Multi-axis diamond anvil cell

The diamond anvil cell (DAC) has been widely used in high-pressure research. Despite significant progress over the past five decades, the opposed anvil geometry in the DAC inevitably leads to a disk-shaped sample configuration at high pressure. This intrinsic limitation is largely responsible for the large pressure and temperature gradients in the DAC, which often compromise precise experiments and their characterizations. Here, we designed and fabricated a multi-axis diamond anvil cell (MDAC) by adopting the concept of a multi-anvil apparatus but using single crystal diamonds as the anvil material. Preliminary data show that the MDAC can generate extreme pressure conditions above 100 GPa. The advantages of the MDAC over a traditional opposed anvil DAC include thicker, voluminous samples, quasi-hydrostatic, or designed deviatoric stress conditions, and multidirectional access windows for optical applications and x-ray probes. In this article, we present the design and performance of a prototype MDAC, as well as the application prospects in high-pressure research.

47 OTHER INSTRUMENTATION↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗

Gimballed Tracking Mount Pointing Angle Qualification

Tonopah Test Range (TTR), in support of its testing mission and modernization effort acquired a fleet of new gimballed tracking mounts (GTMs) manufactured by BAE Systems. The new GTMs can be operated remotely during flight tests and provide near real-time target tracking data. Furthermore, test vehicle Time-Space-Position-Information (TSPI) is evaluated using post-test synchronized imagery and pointing angle measurements acquired from each tracking mount. To comply with the Nuclear Enterprise Assurance Program (NEAP), all measurements devices must be certified. In keeping with the NEAP program, qualification of the new GTMs have been assessed to confirm that their pointing angle measurements produce acceptable TSPI results. This study only evaluated the four GTMs as a stand-alone solution and found that the GTMs meet their performance requirement of 0.006 degrees RMS error (or less) for post-processed pointing angles and produced TSPI solution with error volumes on the order of one meter or less. The new GTMs will be utilized in combination with existing optical tracking mounts, which will only improve the accuracy of the resulting TSPI data product. Details regarding the approach, analysis, summary results, and conclusions are presented.

42 ENGINEERING↗

Indirect searches for ultraheavy dark matter in the time domain

Dark matter may exist today in the form of ultraheavy composite bound states. Collisions between such dark matter states can release intense bursts of radiation that include γ -rays among the final products. Thus, indirect detection signals of dark matter may include unconventional γ -ray bursts. Such bursts may have been missed not necessarily because of their low arriving γ -ray fluxes, but rather their briefness and rareness. We point out that intense bursts whose nondetection thus far are due to the latter can be detected in the near future with existing and planned facilities. In particular, we propose that, with slight experimental adjustments and suitable data analyses, imaging atmospheric Cherenkov telescopes (IACTs) and Pulsed All-Sky Near-Infrared and Optical Search for Extra-Terrestrial Intelligence (PANOSETI) are promising tools for detecting such rare, brief, but intense bursts. We also show that, if we assume these bursts originate from collisions of dark matter states, IACTs and PANOSETI can probe a large dark matter parameter space beyond existing limits. Additionally, we present a concrete model of dark matter that produces bursts potentially detectable in these instruments. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing ultrafast excited-state dynamics using EUV-IR six-wave-mixing emission spectroscopy

Non-linear processes such as four-wave-mixing have become instrumental in attosecond EUV spectroscopy. Using EUV high harmonics in conjunction with collinear near-infrared and mid-infrared fields, we extended this approach to high-order-mixing between three colors. Specifically, we find that atomic resonances in neon exhibit a significant cross section for six-wave mixing. The MIR probe frequency tunability in our multicolor scheme is employed to access several optically dark resonances and probe the quantum beat of a coherent electronic wavepacket using background-free EUV emission as a diagnostic. This technique can be easily extended to other atomic and molecular systems, and opens the door to multi-dimensional non-linear spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Design and Characterization of a Lens-Coupled System for Dynamic X-Ray Diffraction

X-ray diffraction (XRD) is a necessary technique for understanding states of materials under static and dynamic loading conditions. The higher-pressure Equation of State (EOS) of many materials can only be explored via shock or ramp compression at temperatures and pressures of interest. While static XRD work has yielded EOS measurements in the 100 - 200 GPa regime, dynamic X-ray diffraction (DXRD) can explore EOS phases in the TPa regime, which closely resembles inner-core planetary conditions. DXRD hinges on the ability to measure the exact phase or phase change of a material while under dynamic loading conditions. Macroscopic diagnostic systems (e.g. velocimetry and pyrometry) can infer a phase change but not identify the specific phase entered by a material. While microscopic (atomic-level) diagnostic systems (e.g. DXRD) have been designed and implemented in Department of Energy’s (DOE) National Laboratories complex, the unique nature of Sandia National Laboratories’ Pulsed Power Facility (Z Machine) prohibits the use of such devices. The destructive nature of Z experiments presents a challenge to data capture and retrieval. Furthermore there are electromagnetic interference, X-ray background, and mechanical constraints to consider. Thus, a multi-part X-ray diagnostic for use on the Z Machine and Z-Beamlet Laser system has been designed and analyzed. Portions of this new DYnamic SCintillator Optic (DYSCO) have been built, tested and fielded. A data analysis software has been written. Finally, the radiance profile of the DYSCO’s scintillator has been characterized through experiments performed at the University of Arizona.

36 MATERIALS SCIENCE↗

Freeform three-mirror anastigmatic large-aperture telescope and receiver optics for CMB-S4

CMB-S4, the next-generation ground-based cosmic microwave background (CMB) observatory, will provide detailed maps of the CMB at millimeter wavelengths to dramatically advance our understanding of the origin and evolution of the universe. CMB-S4 will deploy large and small aperture telescopes with hundreds of thousands of detectors to observe the CMB at arcminute and degree resolutions at millimeter wavelengths. Inflationary science benefits from a deep delensing survey at arcminute resolutions capable of observing a large field of view at millimeter wavelengths. This kind of survey acts as a complement to a degree angular resolution survey. The delensing survey requires a nearly uniform distribution of cameras per frequency band across the focal plane. We present a large-throughput, large-aperture (5-meter diameter) freeform three-mirror anastigmatic telescope and an array of 85 cameras for CMB observations at arcminute resolutions, which meets the needs of the delensing survey of CMB-S4. A detailed prescription of this three-mirror telescope and cameras is provided, with a series of numerical calculations that indicate expected optical performance and mechanical tolerance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗