Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Evaluation of Heat Transfer Coefficient from Velocity Distribution in Boundary Layer

This paper describes a method of evaluating heat transfer coefficient from a velocity distribution in the boundary layer. The power law velocity profile and universal velocity distribution in a smooth pipe have been used to evaluate the wall shear stress, and the heat transfer coefficient was evaluated from the wall shear stress using the Chilton-Colburn analogy. The predicted pressure drop was compared with the pressure drop computed by the Colebrook equation, and the predicted heat transfer coefficient was compared with the heat transfer coefficient calculated by the Dittus-Boelter equation. The accuracy of pressure drop prediction was within 1%, and the accuracy of heat transfer coefficient prediction was within 8%. This method has the potential to use a Navier-Stokes based CFD solution to evaluate the heat transfer coefficient in nodal or network flow codes.

Heat Transfer Coefficient↗

Evaluation of Heat Transfer Coefficient from Velocity Distribution in Boundary Layer

This paper describes a method of evaluating heat transfer coefficient from a velocity distribution in the boundary layer. The power law velocity profile and universal velocity distribution in a smooth pipe have been used to evaluate the wall shear stress, and the heat transfer coefficient was evaluated from the wall shear stress using the Chilton-Colburn analogy. The predicted pressure drop was compared with the pressure drop computed by the Colebrook equation, and the predicted heat transfer coefficient was compared with the heat transfer coefficient calculated by the Dittus-Boelter equation. The accuracy of pressure drop prediction was within 1%, and the accuracy of heat transfer coefficient prediction was within 8%. This method has the potential to use a Navier-Stokes based CFD solution to evaluate the heat transfer coefficient in nodal or network flow codes.

Heat Transfer Coefficient↗

Icing Physics Studies Using the 3D SIDRM Test Article: Aerodynamic and Supercooled Liquid Icing Analysis

In-flight icing is an important safety issue and is a factor that affects aircraft design and performance. Newer regulations are driving a need for improvements in airframe and engine icing simulation capability. Experimental data is required for development of icing physics models and simulation validation. To that end, this paper presents the analysis of the supercooled liquid icing data subset from tests conducted in 2022 at the NASA Icing Research Tunnel that studied both supercooled water and ice-crystal icing. The test article that was utilized replicated 3D geometrical features of an inter-compressor duct and strut region of a turbofan engine. The surfaces of the Simulated Inter-compressor Duct Research Model (SIDRM) can be heated to simulate the warm surfaces of the turbofan inter-compressor duct. The test article is instrumented with pressure taps, heaters, heat flux gauges, and thermocouples, while a 3D laser scanner, cameras, and a scale to measure ice mass were utilized to characterize the icing behavior. The aim of these tests was to generate ice accretions on the SIDRM test article under well-characterized supercooled liquid icing and ice crystal icing conditions. This paper discusses measurements related to aerodynamic testing and supercooled liquid icing tests that were conducted. Aerodynamic measurements were analyzed and compared to computational simulations and were found to be in good agreement for the range of airspeeds (50 to 230 knots) and angles of attack (0 to 4°) tested. Various parametric sweeps were conducted during the supercooled liquid icing portion of the test entry (cloud median volumetric diameter ranged from 15 to 90 µm, total air temperature from -3 to -17 °C, angle of attack from 0 to 4°, and accretion time from 5 to 20 min). These sweeps were performed to measure that parameter’s impact on ice accretion size, location (icing extent), characteristics (such as glaze/rime ice and shedding behavior), and test article surface temperature. Analysis of the test data showed that clouds composed of larger drops, colder air temperatures, smaller angles of attack, and longer spray times were the primary parameters that resulted in accretions with greater ice mass. Test article angle of attack and cloud droplet size influenced the location of ice accretion as these two parameters directly impact collection efficiency. With respect to icing characteristics, total air temperature dictated icing type, and smaller cloud drop size along with warmer air temperatures resulted in greater amounts of ice shedding. Surface temperature increased during ice accretion from the release of latent (fusion) heat, where total air temperature and cloud drop size impacted the amount of surface temperature change. The icing measurements collected during the SIDRM tests will be used to develop and validate 3D computational engine icing tools, such as GlennICE, that predictively assesses the onset and growth of ice. One of the goals of the sponsoring NASA project is to develop simulation models and tools that can assist in the design and certification of engines for flight in icing conditions in a cost effective way.

supercooled liquid icing↗

Icing Physics Studies Using the 3D SIDRM Test Article: Aerodynamic and Supercooled Liquid Icing Analysis

In-flight icing is an important safety issue and is a factor that affects aircraft design and performance. Newer regulations are driving a need for improvements in airframe and engine icing simulation capability. Experimental data is required for development of icing physics models and simulation validation. To that end, this paper discusses analyzed data from icing tests conducted with a 3D test article in 2022 at the NASA Icing Research Tunnel. The test article, whose geometry is representative of an inter-compressor duct and strut region of a turbofan engine, has been designed and constructed to study the physics of supercooled water icing and ice crystal icing. The surfaces of the Simulated Inter-compressor Duct Research Model (SIDRM) can be heated to simulate the warm surfaces of the turbofan inter-compressor duct. The test article is instrumented with pressure taps, heaters, heat flux gauges, and thermocouples, while a 3D laser scanner, cameras, and a scale to measure ice mass were utilized to characterize the icing behavior. The aim of these tests was to generate ice accretions on the SIDRM test article under well-characterized supercooled liquid icing and ice crystal icing conditions. This paper discusses measurements related to aerodynamic tests and supercooled liquid icing tests that were conducted. Aerodynamic measurements were analyzed and compared to computational simulations and were found to be in good agreement for the range of airspeeds (50 to 230 knots) and angles of attack (0 to 4°) tested. Various parametric sweeps were conducted during the supercooled liquid icing portion of the test entry (cloud median volumetric diameter ranged from 15 to 90 µm, total air temperature from -3 to -17 °C, angle of attack from 0 to 4°, and accretion time from 5 to 20 min). These sweeps were performed to measure that parameter’s impact on ice accretion size, location, characteristics (such as glaze/rime ice and shedding behavior), and test article surface temperature. Analysis of the test data showed that clouds composed of larger drops, colder air temperatures, smaller angles of attack, and longer spray times were the primary parameters that resulted in accretions with greater ice mass. Test article angle of attack and cloud droplet size influenced the location of ice accretion as these two parameters directly impact collection efficiency. With respect to icing characteristics, total air temperature dictated icing type, and smaller cloud drop size along with warmer air temperatures resulted in greater amounts of ice shedding. Surface temperature increased during ice accretion from the release of latent (fusion) heat, where total air temperature and cloud drop size impacted the amount of surface temperature change. The icing measurements collected during the SIDRM tests will be used to develop and validate 3D computational engine icing tools, such as GlennICE, that predictively assesses the onset and growth of ice. One of the goals of the sponsoring NASA project is to develop simulation models and tools that can assist in the design and certification of engines for flight in icing conditions in a cost‑effective way.

supercooled liquid icing↗

Consolidation of A Sodium Heat Pipe and Stirling Engine for Fission Surface Power

The Consolidated Heat Pipe (CHP) is a new design in which a sodium heat pipe is welded directly to the hot end of the Stirling engine to deliver thermal power more efficiently. The new integrated interface aims to reduce the large temperature drop (about 120 °C) that was measured across the bolted clamp joint between the Stirling engine and the heat pipes during the Kilopower Reactor Using Stirling TechnologY (KRUSTY) test from 2018. Initial testing and characterization of the CHP was performed in ambient air at the NASA Glenn Research Center (GRC). In the test, the heat pipe evaporator section was heated with a tube furnace. The thermal power was then transported to the Stirling engine integrated with a linear alternator that produced electrical power. The CHP has been tested at a hot end temperature ranging from 600 °C - 800 °C and a variety of other Stirling engine parameters (cold end temperature, piston amplitude and pressure). The results show that the temperature drop between the Stirling engine and the heat pipe has been reduced to 2°C - 4 °C. An overall temperature drop of 20 °C – 60 °C was also noted within the heat pipe depending on the combination of parameters mentioned above. Overall, it has been shown that the new Consolidated Heat Pipe design significantly improved the thermal interface to the Stirling engine.

Consolidated↗

Consolidation of A Sodium Heat Pipe and Stirling Engine for Fission Surface Power

The Consolidated Heat Pipe (CHP) is a new design in which a sodium heat pipe is welded directly to the hot end of the Stirling engine to deliver thermal power more efficiently. The new integrated interface aims to reduce the large temperature drop (about 120 °C) that was measured across the bolted clamp joint between the Stirling engine and the heat pipes during the Kilopower Reactor Using Stirling TechnologY (KRUSTY) test from 20181. Initial testing and characterization of the CHP was performed in ambient air at the NASA Glenn Research Center (GRC). In the test, the heat pipe evaporator section was heated with a tube furnace. The thermal power was then transported to the Stirling engine integrated with a linear alternator that produced electrical power. The CHP has been tested at a hot end temperature ranging from 600 °C - 800 °C and a variety of other Stirling engine parameters (cold end temperature, piston amplitude and pressure). The results show that the temperature drop between the Stirling engine and the heat pipe has been reduced to 2°C - 4 °C. An overall temperature drop of 20 °C – 60 °C was also noted within the heat pipe depending on the combination of parameters mentioned above. Overall, it has been shown that the new Consolidated Heat Pipe design significantly improved the thermal interface to the Stirling engine.

Consolidated↗

Lunar Dust Capture Using a Novel, Multiplexed Inertial Filter

Multiplexed inertial filtration is new. It holds promise to capture and contain lunar dust with less pressure drop. Even when the filter contains significant amounts of captured lunar dust, the pressure drop remains relatively low. State of the art vacuum cleaners use a system with 4 different filter: they can contain large amounts of lunar dust and maintain low pressure drop, but because they require 4 filters, the system size is relatively large. State of the are miniature vacuum cleaners are small, but the single in-line depth filter clogs easily. The goal of this CIF project is to develop a lunar dust vacuum cleaner <1000 cc in size, with high capacity and low dP.

Lunar Soil↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗

Rolling Horizon with K-Position Search Method for Strategic Deconfliction of Package Delivery UAS

This research focuses on the strategic deconfliction of unmanned aircraft systems (UAS) in an urban package delivery environment with two depots and multiple drop-off locations. Since the formulated mixed-integer nonlinear programming (MINLP) problem is non-deterministic polynomial-time (NP) hard, a heuristic algorithm called "rolling horizon with k-position search (KPS)" is used to compute the departure sequence and scheduled time of departure (STD) of each UAS at a depot, considering temporal constraints at en-route crossing waypoints and depots for strategic deconfliction. The simulation studies show that an increase in the value of k (local neighborhood search) in the KPS reduces the average ground delay at the cost of an increase in the computation time for a given number of UAS, size of the rolling horizon window, and number of depots involved in the local neighborhood search. The studies also show that for a given rolling horizon window, the computation time increases exponentially with an increase in the total number of UAS flights when serial processing the local neighborhood search of KPS (with k > 1) and drops by an order of magnitude upon performing the local neighborhood search of KPS using parallel processing instead of serial processing. The computation time drops with the reduction in air traffic complexity of a scenario for a given number of flights, k (local neighborhood search), and rolling horizon window.

UTM↗

Analysis, Verification, and Application of Equations and Procedures for Design of Exhaust-pipe Shrouds

Investigations were made to develop a simplified method for designing exhaust-pipe shrouds to provide desired or maximum cooling of exhaust installations. Analysis of heat exchange and pressure drop of an adequate exhaust-pipe shroud system requires equations for predicting design temperatures and pressure drop on cooling air side of system. Present experiments derive such equations for usual straight annular exhaust-pipe shroud systems for both parallel flow and counter flow. Equations and methods presented are believed to be applicable under certain conditions to the design of shrouds for tail pipes of jet engines.

HEAT EXCHANGERS, SHROUDED↗

Student Design Challenges in Capillary Flow

For some grade 8-12 students, capillary flow has bridged the gap between the classroom and research facility, from normal gravity to microgravity. In the past four years, NASA and the Portland State University (PSU) have jointly challenged students to design test cells, using Computer-Aided Design (CAD), to study capillary action in microgravity as PSU has done on the International Space Station (ISS). Using the student-submitted CAD drawings, the test cells were manufactured by PSU and tested in their 2.1-second drop tower. The microgravity results were made available online for student analysis and reporting. Over 100 such experiments have been conducted, where there has been participation from 15 states plus a German school for the children of U.S. military personnel. In 2016, a related NASA challenge was held in partnership with the ASGSR, again, based on the research conducted by PSU. In this challenge, grade 9-12 students designed and built devices using capillary action to launch droplets as far as possible in NASAs 2.2 Second Drop Tower. Example results will be presented by students at this conference. The challenges engage students in ISS science and technology and can inspire them to pursue technical careers.

capillary flow↗

Retrieving DSD Moments from GPM-DPR: A Simulation Study Based on the Full DSD Spectra Characterized by the Generalized Gamma Model

Recently, a method to retrieve rain drop size distribution (DSD) moments from X-band dual polarization radar measurements has been developed using copolar reflectivity, differential reflectivity and specific attenuation. Two reference moments are retrieved first, followed by reconstructing the DSDs and calculating other moments using a generalized gamma model to represent the underlying shape, h(x), corresponding to the pair of chosen reference moments. Here we explore a similar approach but the retrieval method in this study uses dual-frequency radar measurements. In the case of GPM-DPR, the two frequencies are 13.8and 35 GHz, and their products include attenuation corrected reflecivities at both frequencies (Z and Z) and the specific attenuation (k, k, if available). Our approach is to use these products to determine two reference moments, namely M3 andM6 representing the third and the sixth moments respectively. Then, as with the polarimetric radar retrievals, we use the most probable h(x) to reconstruct the full DSD spectra, from which other moments are calculated. The best two DPR products for estimating M3 and M6 appear to be A and Z. Figure 1 shows the retrievals versus the ‘true’ moments. 2930 three-minute DSDs were used for the (T-matrix) scattering calculations at Ku and Ka bands but only cases with A > 0.5 dB/km were chosen. For the retrieved moments, the integration was performed only up to 6 mm drop diameter. The [1:1] line is included in Fig. 1. Even with just two DPR products as input the results seem promising, although the lower order moments show somewhat more scatter, especially the zeroth moment, M0. We will quantify the retrieval errors, and additionally examine the stability of h(x). For the latter, data from (i) Greeley, Colorado, (ii) Huntsville, Alabama, and (iii)Wallops, Virginia, will be used. Finally, a GPM overpass case over Huntsville, during a widespread rain event on 11 April 2016, will be considered as an initial test case.

precipitation↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

Spiral spring/strain gage combination accurately measures shock induced deflection

Spiral springs equipped with strain gages which are hard-wired to readout instrumentation, measure deflection between two relatively inaccessible surfaces in a drop test that causes them to close to near flatness. This technique has been successfully used on Apollo drop tests to measure deflection between aft bulkhead and heatshield.

Berven, B. R.↗

Remotely operated high pressure valve protects test personnel

High pressure valve used in testing certain spacecraft systems is safely opened and closed by a remotely stationed operator. The valve is self-regulating in that if the incoming pressure drops below a desired value the valve will automatically close, warning the operator that the testing pressure has dropped to an undesired level.

Howland, B. T.↗

Test of sodium boiling in a single tube-in- shell heat exchanger over the range 1720 deg to 1980 deg F /1211 to 1355 K/

Sodium was boiled in a vertical, 1/2-inch (1.27-cm) inside diameter by 4-fOOt (1.22-m) long tube. The columbium alloy boiler operated at flow rates of 75 to 380 lbm/hr (9.4 to 48 g/sec) and up to 0.93 quality. Boiling performance depended on whether the inlet flow was two-phase or liquid. Two-phase momentum pressure drops were 1(1/2) times frictional drops. Qualities over 0.9 were obtained at some critical (burnout) boiling conditions. Liquid superheats up to 250° F (139 K) existed before initiation of boiling.

James P. Lewis↗

Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

Springborn, R. H.↗