Engineering Papers⌕ Search

NASA NTRS · 20170005660

Student Design Challenges in Capillary Flow

Abstract

For some grade 8-12 students, capillary flow has bridged the gap between the classroom and research facility, from normal gravity to microgravity. In the past four years, NASA and the Portland State University (PSU) have jointly challenged students to design test cells, using Computer-Aided Design (CAD), to study capillary action in microgravity as PSU has done on the International Space Station (ISS). Using the student-submitted CAD drawings, the test cells were manufactured by PSU and tested in their 2.1-second drop tower. The microgravity results were made available online for student analysis and reporting. Over 100 such experiments have been conducted, where there has been participation from 15 states plus a German school for the children of U.S. military personnel. In 2016, a related NASA challenge was held in partnership with the ASGSR, again, based on the research conducted by PSU. In this challenge, grade 9-12 students designed and built devices using capillary action to launch droplets as far as possible in NASAs 2.2 Second Drop Tower. Example results will be presented by students at this conference. The challenges engage students in ISS science and technology and can inspire them to pursue technical careers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stocker, Dennis P., Wollman, Andrew, Hall, Nancy R., Weislogel, Mark, DeLombard, Richard. 2016-10-26. Student Design Challenges in Capillary Flow. https://ntrs.nasa.gov/citations/20170005660

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

A Study of Heat Transfer and Flow Characteristics of Rising Taylor Bubbles

Practical application of flow boiling to ground- and space-based thermal management systems hinges on the ability to predict the systems heat removal capabilities under expected operating conditions. Research in this field has shown that the heat transfer coefficient within two-phase heat exchangers can be largely dependent on the experienced flow regime. This finding has inspired an effort to develop mechanistic heat transfer models for each flow pattern which are likely to outperform traditional empirical correlations. As a contribution to the effort, this work aimed to identify the heat transfer mechanisms for the slug flow regime through analysis of individual Taylor bubbles.An experimental apparatus was developed to inject single vapor Taylor bubbles into co-currently flowing liquid HFE 7100. The heat transfer was measured as the bubble rose through a 6 mm inner diameter heated tube using an infrared thermography technique. High-speed flow visualization was obtained and the bubble film thickness measured in an adiabatic section. Experiments were conducted at various liquid mass fluxes (43-200 kgm2s) and gravity levels (0.01g-1.8g) to characterize the effect of bubble drift velocityon the heat transfer mechanisms. Variable gravity testing was conducted during a NASA parabolic flight campaign.Results from the experiments showed that the drift velocity strongly affects the hydrodynamics and heat transfer of single elongated bubbles. At low gravity levels, bubbles exhibited shapes characteristic of capillary flows and the heat transfer enhancement due to the bubble was dominated by conduction through the thin film. At moderate to high gravity, traditional Taylor bubbles provided small values of enhancement within the film, but large peaks in the wake heat transfer occurred due to turbulent vortices induced by the film plunging into the trailing liquid slug. Characteristics of the wake heat transfer profiles were analyzed and related to the predicted velocity field. Results were compared and shown to agree with numerical simulations of colleagues from EPFL, Switzerland.In addition, a preliminary study was completed on the effect of a Taylor bubble passing through nucleate flow boiling, showing that the thinning thermal boundary layer within the film suppressed nucleation, thereby decreasing the heat transfer coefficient.

capillary flow↗