Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Unveiling decaying mechanism through quantitative structure-activity relationship in electrolytes for lithium-ion batteries

Understanding the decaying mechanism in lithium-ion batteries (LIBs) is critical to establishing a stable electrolyte system. Despite the advent of various novel electrolyte solvents designated for high-voltage LIBs, their working principles are not fully understood. Currently, oxidative decomposition of electrolytes is believed to be the major cause of capacity fade, and tremendous effort has been devoted to discovering a new electrolyte with enhanced anodic stability. However, the oxidative decomposition process cannot solely explain the rapid decay of some electrolyte systems with intrinsic high anodic stability when used with a high-nickel layered oxide cathode such as LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622). In this report, a study of the quantitative structure-activity relationship was conducted to deepen the mechanistic understanding of the decay in high-voltage LIBs. Here, the results obtained from the newly introduced molecular pair analysis and linear free-energy relationship (LFER) studies were highly consistent with the solvation-involved decaying mechanism in a high-nickel layered oxide cathode cycling at high voltage (> 4.5 V vs. Li/Li + ). There was no evidence correlating the solvation ability of electrolyte solvents with the decay of a high-nickel layered oxide cathode cycling at a relatively low voltage (< 4.3 V vs. Li/Li + ), nor with the high-voltage spinel cathode LiNi 0.5 Mn 1.5 O 4 (LNMO). Undoubtedly, the unveiled mechanistic insight provides a critical guideline for the development of an appropriate electrolyte system targeting different high-voltage cathode materials.

25 ENERGY STORAGE↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Degradation-related defect level in weathered silicon heterojunction modules characterized by deep level transient spectroscopy

Commercial silicon heterojunction photovoltaic modules, known as amorphous-silicon-based heterojunction with intrinsic thin-film layer (HIT) modules, show average degradation after 10 years in the field. HIT modules weathered outdoors in Colorado and Florida display mostly uniform decreases in intensity when mapped with photoluminescence (PL) imaging compared to a control module. Flash-table-based current-voltage curves show that degradation is dominated by voltage loss. Samples are cored from each of the modules, and deep level transient spectroscopy (DLTS) detects three electron-trap defect states in all modules with activation energies of electron emission from the defects of 0.07, 0.16, and 0.50 eV. DLTS measurements on the weathered modules show an additional deep-level, electron-trap defect state with an activation energy of 0.51 eV and a trap density of approximately 10 12 cm –3 . The capture rate is measured using varying short filling pulse times, and the resulting capture cross section is estimated to be 1.1x10 –16 cm 2 . The development of the weathering-related defect level correlates to decreases in carrier lifetime, PL intensity, and module voltage. Various depths of the space charge region are probed with increments in applied reverse bias and filling-pulse bias. Furthermore, this DLTS depth profiling shows a trend of trap density increasing with less applied reverse bias, suggesting that the weathering-related defect increases carrier recombination toward the interface between the bulk silicon wafer and the junction-forming amorphous-silicon passivation layers.

14 SOLAR ENERGY↗

Dynamics of the water-plasma interface in various discharge modes of atmospheric-pressure plasmas

This paper presents an experimental study of the dynamics of the water-plasma interface during the interaction high-voltage (HV) atmospheric pressure discharge with the water surface. Under the influence of the voltage applied to the pin type electrode, discharges are formed at the air layer between the sharp-tip HV electrode and deionized water. Three discharge regimes were identified from synchronized electrical waveforms and imaging: (i) a weak linear regime at 3–10.6 kV, (ii) a branching streamer regime at the maximum applied voltage of 12.6 kV, and (iii) a continuous arc-like regime occurring during the transition to lower voltage and higher current (e.g., U ≈ 3.2 kV, I ≈ 4.07 mA). High-speed shadowgraph images showed a symmetric interfacial cavity whose depth increased nonlinearly with voltage from h 0 ≈ 0.1 mm at 3 kV to h 0 ≈ 2.7 mm at 10.6 kV, reaching a maximum depth of h 0 ≈ 5.9 mm at 12.6 kV, while the cavity disappeared in the continuous-channel regime and was replaced by outward-propagating wave-like motion. The deformation of the water surface during the discharge-water interaction is governed by the balance between electric field forces, surface tension, gravitational forces, and electrohydrodynamic forces, whose relative contributions vary with the applied voltage. This effect was explained by quantitatively estimating the magnitudes of the acting forces and establishing the force balance. Optical emission spectroscopy in the continuous-channel regime indicated air plasma signatures and yielded a gas temperature of approximately 400 K, while prolonged operation (≈ 20 min) increased the water temperature to ~ 70 °C, reduced the water-layer thickness from 6 mm to 3 mm, and decreased pH from 7 to 4. These regime-resolved, quantitative results clarify how the dominant interfacial forcing shifts with discharge mode and provide a mechanistic basis for controlling plasma-water interactions in atmospheric-pressure applications.

atmospheric pressure plasma↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Optimal Planning and Operation of Multi-Frequency HVac Transmission Systems

Low-frequency high-voltage alternating-current (LF-HVac) transmission scheme has been recently proposed as an alternative solution to conventional 50/60-Hz HVac and high-voltage direct-current (HVdc) schemes for bulk power transfer. This paper proposes an optimal planning and operation for loss minimization in a multi-frequency HVac transmission system. In such a system, conventional HVac and LF-HVac grids are interconnected using back-to-back (BTB) converters. The dependence of system MW losses on converter dispatch as well as the operating voltage and frequency in the LF-HVac is discussed and compared with that of HVdc transmission. Based on the results of the loss analysis, multi-objective optimization formulations for both planning and operation stages are proposed. The planning phase decides a suitable voltage level for the LF-HVac grid, while the operation phase determines the optimal operating frequency and power dispatch of BTB converters, generators, and shunt capacitors. A solution approach that effectively handles the variations of transmission line parameters with the rated voltage and operating frequency in the LF-HVac grid is proposed. The proposed solutions of the planning and operation stages are evaluated using a multi-frequency HVac system. The results show a significant loss reduction and improved voltage regulation during a 24-hour simulation.

Nguyen, Quan H.↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of the Impact of Particle Growth on Transport Losses in Polymer-Electrolyte Fuel Cells

Voltage cycling causes catalyst nanoparticles in polymer-electrolyte fuel cells to grow. The concomitant loss of interfacial area results in larger kinetic, transport, and possibly ohmic overpotentials. This paper uses recently published experimental data and mathematical models to investigate the evolutions of transport and ohmic resistances to platinum nanoparticles located on the surface and inside the micropores of carbon black supports. Resistance to oxygen transport rises as surface area declines primarily because the flux to each remaining larger platinum particle increases. The path lengths governing oxygen diffusion to surface and buried platinum sites also increase as nanoparticles grow. Platinum nanoparticles on the surface become relatively less favorable as voltage cycling proceeds because they grow faster than platinum in micropores. Because voltage cycling causes total interfacial area to decline, and the fraction located inside micropores to increase, nanoscale ohmic losses increase as a catalyst layer decays. The practical importance of this effect is difficult to discern because proton conductivity in carbon micropores is not well characterized.

07 ISOTOPE AND RADIATION SOURCES↗

Mitigation of Pitting on Nitrogen-Doped Niobium Surfaces through Two-Step Electropolishing

Surface processing of niobium superconducting RF cavities used in particle accelerators is crucial for determining their performance. The nitrogen (N)-doping method, developed at Fermilab, enhances the cavities’ quality factor by doping the cavity’s interior surface with N atoms at 800 °C. After N-doping, electropolishing (EP) is employed to remove the niobium nitride phases and attain the desired concentration of interstitial N atoms. This study explores the effects of EP conditions on N-doped niobium samples. The samples were electropolished at 5 to 40 °C and voltages between 3 and 22 V. Different EP voltage ranges produced two types of pits, classified based on their sizes. Larger pits, linked to higher voltages, are also affected by the reaction rate. Pitting could be reduced at a lower temperature and adequate EP voltage. However, to effectively minimize gas evolution forming large-sized pitting, peeling off the top nitride layer before EP might be beneficial. This was achieved through precise low-voltage etching, forming a two-step EP process. The process involves removing the top 100–200 nm layer at a low voltage, followed by standard EP to remove the required material. This two-step EP process effectively mitigated the pitting risk associated with gas evolution on N-doped surfaces.

43 PARTICLE ACCELERATORS↗

Heterosynaptic plasticity in biomembrane memristors controlled by pH

Abstract In biology, heterosynaptic plasticity maintains homeostasis in synaptic inputs during associative learning and memory, and initiates long-term changes in synaptic strengths that nonspecifically modulate different synapse types. In bioinspired neuromorphic circuits, heterosynaptic plasticity may be used to extend the functionality of two-terminal, biomimetic memristors. In this article, we explore how changes in the pH of droplet interface bilayer aqueous solutions modulate the memristive responses of a lipid bilayer membrane in the pH range 4.97–7.40. Surprisingly, we did not find conclusive evidence for pH-dependent shifts in the voltage thresholds ( V* ) needed for alamethicin ion channel formation in the membrane. However, we did observe a clear modulation in the dynamics of pore formation with pH in time-dependent, pulsed voltage experiments. Moreover, at the same voltage, lowering the pH resulted in higher steady-state currents because of increased numbers of conductive peptide ion channels in the membrane. This was due to increased partitioning of alamethicin monomers into the membrane at pH 4.97, which is below the pKa (~5.3–5.7) of carboxylate groups on the glutamate residues of the peptide, making the monomers more hydrophobic. Neutralization of the negative charges on these residues, under acidic conditions, increased the concentration of peptide monomers in the membrane, shifting the equilibrium concentrations of peptide aggregate assemblies in the membrane to favor greater numbers of larger, increasingly more conductive pores. It also increased the relaxation time constants for pore formation and decay, and enhanced short-term facilitation and depression of the switching characteristics of the device. Modulating these thresholds globally and independently of alamethicin concentration and applied voltage will enable the assembly of neuromorphic computational circuitry with enhanced functionality. Impact statement We describe how to use pH as a modulatory “interneuron” that changes the voltage-dependent memristance of alamethicin ion channels in lipid bilayers by changing the structure and dynamical properties of the bilayer. Having the ability to independently control the threshold levels for pore conduction from voltage or ion channel concentration enables additional levels of programmability in a neuromorphic system. In this article, we note that barriers to conduction from membrane-bound ion channels can be lowered by reducing solution pH, resulting in higher currents, and enhanced short-term learning behavior in the form of paired-pulse facilitation. Tuning threshold values with environmental variables, such as pH, provide additional training and learning algorithms that can be used to elicit complex functionality within spiking neural networks. Graphical abstract

36 MATERIALS SCIENCE↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Scientific/Technical Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 µm or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

20KV↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower-voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 um or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV-class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

2 kV Al 0.64 Ga 0.36 N-channel high electron mobility transistors with passivation and field plates

Abstract High voltage (∼2 kV) Al 0.64 Ga 0.36 N-channel high electron mobility transistors were fabricated with an on-resistance of ∼75 Ω. mm (∼21 mΩ. cm 2 ). Two field plates of variable dimensions were utilized to optimize the breakdown voltage. The breakdown voltage reached >3 kV (tool limit) before passivation however it reduced to ∼2 kV after Si 3 N 4 surface passivation and field plate deposition. The breakdown voltage and on-resistance demonstrated a strong linear correlation in a scattered plot of ∼50 measured transistors. The fabricated transistors were electrically characterized and benchmarked against the state-of-the-art high-voltage (> 1 kV) Al-rich (>40%) AlGaN-channel transistors in breakdown voltage and on-resistance, indicating significant progress.

Alam, Md Tahmidul (ORCID:000900086556839X)↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗