Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aggregated DER_A Model Parameterization via Online Moving Horizon Estimation

Here, this paper introduces a methodology for parameterizing the DER_A model using a novel smooth mathematical representation, simplifying the process and preserving accuracy in modeling inverter-based generator (IBG). The methodology employs an online parameterization process that can operate in real-time. The model parameterization process is structured into five sequential steps, each targeting a specific aspect of the DER_A model through moving horizon estimation. This approach adapts to systems with varying voltage and frequency support requirements by selectively applying each step. Simulation results on systems with both known and unknown parameters validate the methodology’s effectiveness. The online moving horizon estimation technique accurately captures the dynamics of the overall system and ensures that the parameterized DER_A model closely mirrors the real system’s voltage, current, and power dynamics. The findings highlight the potential of this methodology to substantially improve and simplify the dynamic modeling of power systems, paving the way for more reliable and robust IBG and grid integration.

42 ENGINEERING↗

Temporal Ni K-Edge X-ray Absorption Spectroscopy Study Reveals the Kinetics of the Ni Redox Behavior of the Iron-Nickel Oxide Bimetallic OER Catalyst

Operando X-ray absorption spectroscopy (XAS) can be utilized to probe the phase and structural changes of FeNiOx and similar transition metal oxide electrocatalysts during electrocatalytic reactions. However, capturing the temporal changes occurring in the operando chemistry of electrocatalysts has been little studied. Here, in this work, we successfully capture the time-resolved changes at the Ni K-edge for both the X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) regions of an aqueous phase synthesized FeNiO x bimetallic nanoparticle electrocatalyst. During a stepped voltage experiment, the temporal change in the Ni K-edge was observed as the applied voltage was stepped from 0.7 to 0.8 V versus the silver/silver chloride reference electrode, and the change observed is associated with the Ni redox transition from the 2+ to 3+/4+ oxidation state. Individual XAS spectra were obtained in 90 s, and a total of 9 scans post voltage step showed a unique transition from a hydroxide to an oxyhydroxide phase. The shift in absorption edge energy position and the changes in spectral shape for individual scans explain the typically observed broadening of the Ni K-edge XANES spectrum during time-averaged operando XAS, and a kinetic analysis revealed a first-order observed rate constant, |k obs |, of 0.00426 s –1 and a half-life (t 1/2 ) of 163 s. Multivariate curve resolution-alternating least squares analysis followed by linear combination fitting analysis for time-averaged versus time-resolved Ni K-edge changes upon voltage step show distinct differences in estimated contributions from Ni 2+ oxide/hydroxide phases. Detailed EXAFS modeling shows the phase transition from hydroxide to oxyhydroxide on top of the unchanged metallic core.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

An Iterative Bidirectional Gradient Boosting Algorithm for CVR Baseline Estimation

This paper presents a novel iterative, bidirectional, gradient boosting (bidirectional-GB) algorithm for estimating the baseline of the Conservation Voltage Reduction (CVR) program. We define the CVR baseline as the load profile during the CVR period if the substation voltage is not lowered. The proposed algorithm consists of two key steps: selection of similar days and iterative bidirectional-GB training. In the first step, preand post-event temperature profiles of the targeted CVR day are used to select similar days from historical non-CVR days. In the second step, the pre-event and post-event similar days are used to train two GBMs iteratively: a forward-GBM and a backwardGBM. After each iteration, the two generated CVR baselines are reconciled and only the first and the last points on the reconciled baseline are kept. The iteration repeats until all CVR baseline points are generated. We tested two gradient boosting methods (i.e., GBM and LighGBM) with two data resolutions (i.e., 15and 30-minute). The results demonstrate that both the accuracy and performance of the algorithm are satisfactory.

Lee, Han Pyo↗

Current-Voltage Analysis Tool for Solar Fuel Production (CATS) v0.1

The program is expected to be a useful tool during operation of a range of solar-driven electrochemical devices, such as PV-electrolyzers and photoelectrochemical (PEC) devices. It makes use of current-voltage data collected during operation, operation parameters that are easily accessible for many devices of interest. The program captures the time-dependence of loss mechanisms at play during PEC device operation and opens the door for real-time optimizations of operational parameters like the feed humidity to minimize performance losses. Currently, the program is useful for applications where the current-voltage polarization response of the photoabsorber and electrolyzer are pre-recorded, and changes over time can be estimated based on the pre-recorded current-voltage scans. More complicated scenarios that involve permanent degradation of the PV component or complex calculations of the electrolyzer current-voltage characteristics may be included in future versions of this software. Aside from the possibility of deconvoluting loss mechanisms, this software can also reveal possible performance benefits by convective PV cooling when the photoabsorber is integrated into the electrolysis cell. The latter can highlight why certain device architectures may be beneficial over others. No similar technologies are known to the developer.

Kistler, Tobias↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Analysis of an all-solid state nanobattery using molecular dynamics simulations under an external electric field

Present Li-ion battery (LIB) technology requires strong improvements in performance, energy capacity, charging-time, and cost to expand their application to e-mobility and grid storage. Li-metal is one of the most promising materials to replace commercial anodes such as graphite because of its 10 times higher specific capacity. However, Li-metal has high reactivity with commercial liquid electrolytes; thus, new solid materials are proposed to replace liquid electrolytes when Li-metal anodes are used. We present a theoretical analysis of the charging process in a full nanobattery, containing a LiCoO 2 cathode, a Li 7 P2S 8 I solid-state electrolyte (SSE), a Li-metal anode as well as Al and Cu collectors for the cathode and anode, respectively. In addition, we added a Li 3 P/Li 2 S film as a solid electrolyte interphase (SEI) layer between the Li-anode and SSE. Thus, we focus this study on the SEI and SSE. We simulated the charging of the nanobattery with an external voltage by applying an electric field. We estimated temperature profiles within the nanobattery and analyzed Li-ion transport through the SSE and SEI. Here, we observed a slight temperature rise at the SEI due to reactions forming $PS_{3}^{–}$ and $P_{2}S_{7}^{4}$$^{–}$ fragments at the interfaces; however, this temperature profile changes due to the charging current under the presence of the external electric field ε = 0.75 V Å –1 . Without the external field, the calculated open-circuit voltage (OCV) was 3.86 V for the battery, which is within the range of values of commercial cobalt-based LIBs. This voltage implies a spontaneous fall of available Li-ions from the anode to the cathode (during discharge). The charge of this nanobattery requires overcoming the OCV plus an additional voltage that determines the charging current. Thus, we applied an external potential able to neutralize the OCV, plus an additional 1.6 V to induce the transport of Li + from the cathode up to the anode. Several interesting details about Li + transport paths through the SSE and SEI are discussed.

25 ENERGY STORAGE↗

Dynamics of the water-plasma interface in various discharge modes of atmospheric-pressure plasmas

This paper presents an experimental study of the dynamics of the water-plasma interface during the interaction high-voltage (HV) atmospheric pressure discharge with the water surface. Under the influence of the voltage applied to the pin type electrode, discharges are formed at the air layer between the sharp-tip HV electrode and deionized water. Three discharge regimes were identified from synchronized electrical waveforms and imaging: (i) a weak linear regime at 3–10.6 kV, (ii) a branching streamer regime at the maximum applied voltage of 12.6 kV, and (iii) a continuous arc-like regime occurring during the transition to lower voltage and higher current (e.g., U ≈ 3.2 kV, I ≈ 4.07 mA). High-speed shadowgraph images showed a symmetric interfacial cavity whose depth increased nonlinearly with voltage from h 0 ≈ 0.1 mm at 3 kV to h 0 ≈ 2.7 mm at 10.6 kV, reaching a maximum depth of h 0 ≈ 5.9 mm at 12.6 kV, while the cavity disappeared in the continuous-channel regime and was replaced by outward-propagating wave-like motion. The deformation of the water surface during the discharge-water interaction is governed by the balance between electric field forces, surface tension, gravitational forces, and electrohydrodynamic forces, whose relative contributions vary with the applied voltage. This effect was explained by quantitatively estimating the magnitudes of the acting forces and establishing the force balance. Optical emission spectroscopy in the continuous-channel regime indicated air plasma signatures and yielded a gas temperature of approximately 400 K, while prolonged operation (≈ 20 min) increased the water temperature to ~ 70 °C, reduced the water-layer thickness from 6 mm to 3 mm, and decreased pH from 7 to 4. These regime-resolved, quantitative results clarify how the dominant interfacial forcing shifts with discharge mode and provide a mechanistic basis for controlling plasma-water interactions in atmospheric-pressure applications.

atmospheric pressure plasma↗

Local measurements of the spatial magnetic field distribution in a z-pinch plasma during and near stagnation using polarization spectroscopy

We present here the detailed measurements of radial distribution of the magnetic field in a gas-puff z-pinch plasma at the final stages of the implosion phase and at stagnation. While the measurements are chordal, the radial distribution of different charge states was utilized to measure the magnetic field locally for certain radii, so that unlike chordal measurements in general, the magnetic field radial distribution was obtained with no need for the Abel inversion of the data. The distribution was measured using the Zeeman effect via a novel spectroscopic technique, at several axial locations, and demonstrates striking features such as the peak field remaining at a radius much larger than the stagnation radius at all times. Furthermore, while the distribution observed is sometimes monotonic with respect to the radius, it is often not, a behavior that can be linked to 2D features in the plasma column resulting from the Rayleigh–Taylor instability. The current flowing through the stagnating plasma was found to be a small fraction of the total current, resulting in clearly insufficient magnetic pressure to balance the plasma pressure at stagnation. The magnetic field data, taken over several axial positions, are used to obtain the true inductance in the imploding plasma for the first time; it is found that the data cannot explain the current turnover at stagnation. A simulation with the MACH2-Tabular Collisional-Radiative Equilibrium magnetohydrodynamics code in the r–z plane shows that the peak of the magnetic field pinches to a much smaller radius than is observed in the spectroscopic data. Furthermore, the depth of the computed current turnover at stagnation is smaller than the measured one. The two observed features of a radially extended magnetic field at stagnation together with a deep current turnover are a challenge to match in simulations. Various calculations and estimates of the inductive and resistive load voltages are examined to ascertain if they are responsible for the observed current notch. Lastly, the results demonstrate that the knowledge of the true inductance in the driven load requires such magnetic-field-distribution measurements and that imaging data or electrical measurements are insufficient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

InP- and GaAs-Based 0.6 eV GaInAs Devices for Thermophotovoltaics and Laser Power Conversion

Emerging applications such as thermal energy grid storage, waste heat recovery and portable power generation require efficient thermophotovoltaic (TPV) converters tuned to temperatures near 1000 Degrees Celsius or below. Metamorphic GaInAs with larger lattice constants than InP present a promising option for these needs. The ability to grow these devices on GaAs substrates instead of more expensive InP would enhance the scalability of these devices. In this talk, we present inverted metamorphic Ga0.3In0.7As photovoltaic converters with sub-0.60 eV bandgaps grown on InP and GaAs substrates. These devices are realized using InAsP or GaInP/InAsP compositionally graded buffers which exhibit threading dislocation densities of 1.3 +/- 0.6 x 106 cm-2 and 8.9 +/- 1.7 x 106 cm-2 on InP and GaAs, respectively. Despite this difference in defect density, the devices generate similar open-circuit voltages of 0.386 V and 0.383 V, respectively, under irradiance producing a short-circuit current density of -10 A/cm2, with bandgap-voltage offsets of 0.20 and 0.21 V. We estimate their thermophotovoltaic efficiency using these measurements coupled with broadband reflectance measurments. The InP-based cell is estimated to yield 1.09 W/cm2 at 1100 Degrees Celsius vs. 0.92 W/cm2 for the GaAs-based cell, with TPV efficiencies of 16.8 vs. 9.2%. Both devices are limited by sub-bandgap absorption, which we assess largely occurs in the graded buffers. We estimate that the 1100 Degrees Celsius thermophotovoltaic efficiencies would increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application as laser power converters in the 2.0-2.3 um atmospheric window. We estimate efficiencies of 36.8% and 32.5% under 2.0 um monochromatic irradiance of 1.86 W/cm2 and 2.81 W/cm2, respectively.

ENGINEERING,MATERIALS SCIENCE,SOLAR ENERGY↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

A Test Bed for Evaluating Frequency Estimation Algorithms in Synthetic Inertia Control: User Manual

As penetration of converter interfaced generators (CIGs) increases, the need for CIG frequency control participation increases. Traditionally, research in this area has been performed using positive sequence simulation software, which provides voltage magnitude and phase measurements, but not point-on-wave (POW) measurements. This means that the effect of frequency estimation algorithms cannot be accurately modeled, especially when the voltage waveform is distorted by faults or load connection events. This report serves as a user manual for an electromagnetic transient simulation testbed, which allows for accurate modeling of frequency estimation and control techniques.

42 ENGINEERING↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗