Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “virtual controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Robust stability of second-order systems

It has been shown recently how virtual passive controllers can be designed for second-order dynamic systems to achieve robust stability. The virtual controllers were visualized as systems made up of spring, mass and damping elements. In this paper, a new approach emphasizing on the notion of positive realness to the same second-order dynamic systems is used. Necessary and sufficient conditions for positive realness are presented for scalar spring-mass-dashpot systems. For multi-input multi-output systems, we show how a mass-spring-dashpot system can be made positive real by properly choosing its output variables. In particular, sufficient conditions are shown for the system without output velocity. Furthermore, if velocity cannot be measured then the system parameters must be precise to keep the system positive real. In practice, system parameters are not always constant and cannot be measured precisely. Therefore, in order to be useful positive real systems must be robust to some degrees. This can be achieved with the design presented in this paper.

Chuang, C.-H.↗

Virtual Tokamak for Test and Development of Plasma Control Applied to NSTX-U

Safe and efficient operation of tokamak experiments depends on shot preparation prior to the experiment to maximize performance and avoid issues that are predictable consequences of known physics. The General Atomics TokSys toolbox is used to test and develop the plasma control system (PCS) on numerous tokamaks around the world. Tokamaks that use a version of the DIII-D PCS can connect it to a TokSys simulation and control a virtual version of the tokamak with the real PCS. Recent upgrades to the simulation include more detailed profile and transport modeling to support design and implementation of optimized scenarios. The simulation combines a module called “Profiles” that simulates the 1D profiles of density, pressure, and current and a module called “GSevolve'' that evolves the 2D Grad-Shafranov equilibrium. The “Profiles'' module primarily uses simplified models for fueling, heating, and current. The TRANSP code provides precomputed diffusion coefficients and heating/current drive profiles from radio-frequency and neutral beam sources for the scenarios being simulated. The fidelity of a simulation can be enhanced by analyzing it with TRANSP and making corrections to the precomputed values and iterating until convergence. Simulations of the National Spherical Torus Upgrade (NSTX-U) are presented. It is shown that the simulation reproduces the experimental profile evolution. Here, the simulation has also been upgraded to reproduce the experimental outcome at points of bifurcation. This is demonstrated with a simulation of vertical displacement in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neural Network Predictive Controller for Grid-Connected Virtual Synchronous Generator

In this paper, a neural network predictive controller is proposed to regulate the active and the reactive power delivered to the grid generated by a three-phase virtual inertia-based inverter. The concept of the conventional virtual synchronous generator (VSG) is discussed, and it is shown that when the inverter is connected to non-inductive grids, the conventional PI-based VSGs are unable to perform acceptable tracking. The concept of the neural network predictive controller is also discussed to replace the traditional VSGs. This replacement enables inverters to perform in both inductive and non-inductive grids. The simulation results confirm that a well-trained neural network predictive controller illustrates can adapt to any grid impedance angle, compared to the traditional PI-based virtual inertia controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical System Security With Deceptive Virtual Hosts for Industrial Control Networks

A challenge facing industrial control network administrators is protecting the typically large number of connected assets for which they are responsible. These cyber devices may be tightly coupled with the physical processes they control and human induced failures risk dire real-world consequences. Dynamic virtual honeypots are effective tools for observing and attracting network intruder activity. This paper presents a design and implementation for self-configuring honeypots that passively examine control system network traffic and actively adapt to the observed environment. In contrast to prior work in the field, six tools were analyzed for suitability of network entity information gathering. Ettercap, an established network security tool not commonly used in this capacity, outperformed the other tools and was chosen for implementation. Utilizing Ettercap XML output, a novel four-step algorithm was developed for autonomous creation and update of a Honeyd configuration. This algorithm was tested on an existing small campus grid and sensor network by execution of a collaborative usage scenario. Automatically created virtual hosts were deployed in concert with an anomaly behavior (AB) system in an attack scenario. Virtual hosts were automatically configured with unique emulated network stack behaviors for 92% of the targeted devices. The AB system alerted on 100% of the monitored emulated devices.

97 MATHEMATICS AND COMPUTING↗

Impact of Increased Inverter-Based Resources on Power System Small-Signal Stability

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

grid-following inverter↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Impact of Increased Inverter Penetration on Power System Small-Signal Stability: Preprint

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter penetration levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter penetration level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Operation and Control of Soft Switching Solid State Transformer as a Virtual Synchronous Machine for Photovoltaic Application

Possibility for control and operation of a three-phase solid state soft switching transformer based as a virtual synchronous machine or synchronverter has been investigated in this paper. The soft switching solid state transformer is used as an interface between the ac grid and a photovoltaic power generation unit supported by a battery bank. The control architecture investigated in this paper is that of a synchronverter to achieve inertial support to the grid and local loads. The operation of the soft switching solid state transformer has also been investigated as a V S M during unbalanced/distorted grid voltage condition. Control objective to achieve oscillation free power transfer between the ports (photovoltaic, battery and grid) has been achieved. The presented architecture has been verified for several important case studies via numerical simulations based on MATLAB/Simulink domain.

grid current controller↗

A Virtual Space Vector Model Predictive Control for a Seven-Level Hybrid Multilevel Converter

This paper proposes a virtual space vector (VSV) model predictive control (MPC) for a three-phase seven-level (7L) hybrid multilevel converter (HMC), where each phase consists of an active-neutral-point-clamped converter with a floating H-bridge. To achieve the best current tracking, which is the primary goal of the proposed algorithm, a novel geometrical positioning approach is proposed to select the optimal voltage vector among all the realspace vectors and VSVs. Then, all the possible switching sequences that belong to the optimal voltage vector are evaluated to realize the dc capacitor voltage balancing and common-mode voltage reduction. Through an external modulator, the optimal voltage vector can be synthesized by using either one-, three-, or seven-segment switching sequence. Compared with the conventional MPC, the proposed VSV-MPC can reduce not only the computational burden but also the current THD. Both simulation and experimental results obtained on silicon carbide based 7L-HMC prototype are presented to validate the feasibility and effectiveness of the proposed VSVMPC strategy.

42 ENGINEERING↗

Live Virtual Constructive (LVC): Interface Control Document (ICD) for the LVC Gateway

This Interface Control Document (ICD) documents and tracks the necessary information required for the Live Virtual and Constructive (LVC) systems components as well as protocols for communicating with them in order to achieve all research objectives captured by the experiment requirements. The purpose of this ICD is to clearly communicate all inputs and outputs from the subsystem components.

LVC↗

Virtual Pressure Sensor for Electronic Expansion Valve Control in a Vapor Compression Refrigeration System

Virtual sensor technology, which uses simulation models/algorithms to calculate a value to represent an unmeasured variable or replace a directly measured reading, has attracted many studies in the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry. However, most virtual sensor technologies are developed for fault detection and diagnostics (FDD) purposes, which generally compare the virtual sensor values with actual measured values to detect if any fault occurred and identify the causes that led to the fault. It is rare to see studies focus on control performance of virtual sensors after substituting an actual sensor. This is particularly important for the system with no redundant sensor since a virtual sensor is the most effective way to operate the system in the desirable region when any sensor failure occurs. To address this gap, this paper develops a new virtual pressure sensor technology to substitute the actual pressure measurement for electronic expansion valve (EXV) control in a vapor compression refrigeration system by integrating compressor and valve characteristics. The control performance of this proposed virtual pressure sensor technology under various operating conditions is validated with experimental data. Closed loop EXV control simulations with the proposed virtual pressure sensor are conducted, and the results are analyzed.

47 OTHER INSTRUMENTATION↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

VAC: A Software Approach to Resilient SCADA Automation

To better secure critical infrastructure, especially power systems, this paper introduces a virtual SCADA automation controller. The automation controller is a gateway into a power subsystem, making it a valuable target for cyber-attacks that could cut it off from the control center and cause a loss of view and control. To prevent this, the Virtual Automation Controller (VAC) is a backup device that mirrors the capabilities of the physical controller. It can communicate via Modbus and DNP3 and is containerized so it can be deployed on a variety of platforms. Furthermore, it utilizes software-defined networking to quickly disconnect a failed automation controller and preserve its state for forensics. The VAC gives system operators time to replace the failed controller and prevents dangerous and costly damage to power systems. The VAC is compared against the SEL 3505-3 RTAC and shown to have the necessary features to act as a failover controller.

Johnson, Jordan↗

Packet router with virtual channel hop buffer control

An integrated circuit includes a network on chip (NOC) that includes a plurality of processing elements and a plurality of NOC nodes, interconnected to the plurality of processing elements. The integrated circuit includes logic that is configured to: increment by one, a virtual channel identifier to produce an incremented destination VC identifier, the virtual channel (VC) identifier associated with at least portion of a packet stored in at least one virtual channel buffer; determine that a destination virtual channel buffer corresponding to the incremented destination VC identifier in a destination NOC node in the NOC is available to store the portion of the packet; and in response to the determination, send the portion of the packet and the incremented destination VC identifier to the destination NOC node.

97 MATHEMATICS AND COMPUTING↗

Distributed Control and Optimization of Virtual Inertia in Power Systems

The integration of renewable energy sources into power grids through inverter-based resources (IBRs) reduces system inertia, leading to faster frequency dynamics and potential grid instability. This paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources during system disturbances, enhancing both system stability and economic performance. Furthermore, we integrate this approach with the traditional inertia placement problem, demonstrating its suitability for existing frameworks. We validate its effectiveness in a 4-bus test system and a two-area 8-bus test system, showcasing its potential for scalable, dynamic inertia management in low-inertia grids.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗