Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improved control of electron computer-generated holographic grating groove profiles using ion beam gas-assisted etching

In a transmission electron microscope, electrons are described by matter-waves with wavelengths five orders of magnitude smaller than optical electromagnetic waves. Analogous to optical holography, electron wavefronts can be shaped using nanoscale holographic gratings. Here we demonstrate a novel, scalable nanofabrication method for creating off-axis holographic gratings that demonstrate near ideal diffraction efficiencies for binary, sinusoidal, and blazed grating groove profiles. We show that this method can produce up to 50 µm diameter area gratings that diffract up to 68% of the transmitted electron wave into a desired diffraction order with less than 7% into any other order. Additionally, we find that the amount of inelastically scattered electrons from the material gratings remaining in the coherent diffraction orders from the gratings is negligible in the far field.

Johnson, Cameron W.↗

STS-1 operational flight profile. Volume 4: Onorbit profile-cycle 3.1.1

The orbital flight test (OFT) phase of the shuttle program consists of four orbital flights beginning in November 1980and continuing through 1981. The major purpose of the OFT program is to demonstrate and verify shuttle systems and flight capabilities by satisfying the OFT requirements, is presented. The onorbit portion of the operational flight profile (OFP) for the first Space Transportation System-1 (STS-1) flight is presented. This onorbit document (volume 4) is one in a series that, taken together, will define the STS-1 OFP. This OFP onorbit document represents a combination of the STS-1 ground rules and constraints and the initialization data. The STS-1 flight activities described reflect the trajectory, consumable, crew activity, and flight requirement baseline as of May 1, 1980. Flight plans for the ascent, onorbit, and descent phases of the test flight are presented.

Source record↗

Improvement of OMI Ozone Profile Retrievals in the Troposphere and Lower Troposphere by the Use of the Tropopause-Based Ozone Profile Climatology

An advance algorithm based on the optimal estimation technique has beeen developed to derive ozone profile from GOME UV radiances and have adapted it to OMI UV radiances. OMI vertical resolution : 7-11 km in the troposphere and 10-14 km in the stratosphere. Satellite ultraviolet measurements (GOME, OMI) contain little vertical information for the small scale of ozone, especially in the upper troposphere (UT) and lower stratosphere (LS) where the sharp O3 gradient across the tropopause and large ozone variability are observed. Therefore, retrievals depend greatly on the a-priori knowledge in the UTLS

Bak, Juseon↗

Marli: Mars Lidar for Global Wind Profiles and Aerosol Profiles from Orbit

The Mars Exploration Analysis Group's Next Orbiter Science Analysis Group (NEXSAG) has recently identified atmospheric wind measurements as one of 5 top compelling science objectives for a future Mars orbiter. To date, only isolated lander observations of martian winds exist. Winds are the key variable to understand atmospheric transport and answer fundamental questions about the three primary cycles of the martian climate: CO2, H2O, and dust. However, the direct lack of observations and imprecise and indirect inferences from temperature observations leave many basic questions about the atmospheric circulation unanswered. In addition to addressing high priority science questions, direct wind observations from orbit would help validate 3D general circulation models (GCMs) while also providing key input to atmospheric reanalyses. The dust and CO2 cycles on Mars are partially coupled and their influences on the atmospheric circulation modify the global wind field. Dust absorbs solar infrared radiation and its variable spatial distribution forces changes in the atmospheric temperature and wind fields. Thus it is important to simultaneously measure the height-resolved wind and dust profiles. MARLI provides a unique capability to observe these variables continuously, day and night, from orbit.

Orbit↗

24-hour human urine and serum profiles of bisphenol A: Evidence against sublingual absorption following ingestion in soup

Extensive first-pass metabolism of ingested bisphenol A (BPA) in the gastro-intestinal tract and liver restricts blood concentrations of bioactive BPA to < 1% of total BPA in humans and non-human primates. Absorption of ingested BPA through non-metabolizing tissues of the oral cavity, recently demonstrated in dogs, could lead to the higher serum BPA concentrations reported in some human biomonitoring studies. We hypothesized that the extensive interaction with the oral mucosa by a liquid matrix, like soup, relative to solid food or capsules, might enhance absorption through non-metabolizing oral cavity tissues in humans, producing higher bioavailability and higher serum BPA concentrations. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 hour period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. Absorption of d6-BPA was rapid (t{sub 1/2} = 0.45 h) and elimination of the administered dose was complete 24 h post-ingestion, evidence against any tissue depot for BPA. The maximum serum d6-BPA concentration was 0.43 nM at 1.6 h after administration and represented < 0.3% of total d6-BPA. Pharmacokinetic parameters, pharmacokinetic model simulations, and the significantly faster appearance half-life of d6-BPA-glucuronide compared to d6-BPA (0.29 h vs 0.45 h) were evidence against meaningful absorption of BPA in humans through any non-metabolizing tissue (< 1%). This study confirms that typical exposure to BPA in food produces picomolar to subpicomolar serum BPA concentrations in humans, not nM concentrations reported in some biomonitoring studies.

60 APPLIED LIFE SCIENCES↗

Material Profile Influences in Bulk-Heterojunctions

he morphology in mixed bulk-heterojunction films are compared using three different quantitative measurement techniques. We compare the vertical composition changes using high-angle annular dark-field scanning transmission electron microscopy with electron tomography and neutron and x-ray reflectometry. The three measurement techniques yield qualita-tively comparable vertical concentration measurements. The presence of a metal cathode during thermal annealing is observed to alter the fullerene concentration throughout the thickness of the film for all measurements. However, the abso-lute vertical concentration of fullerene is quantitatively different for the three measurements. The origin of the quantitative measurement differences is discussed. The authors thank Luna Innovations, Inc. for donating the endohedral fullerenes used in this study and Plextronics for the P3HT. They are gratefully thank the National Science Foundation Energy for Sustainability Program, Award No. 0933435. This work benefited from the use of the Lujan Neutron Scattering Center at Los Alamos Neutron Science Center funded by the DOE Office of Basic Energy Sciences and Los Alamos National Laboratory under DOE Contract DE-AC52-06NA25396. This research was also supported in part by Laboratory Directed Research & Development program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy under contract DE-AC05-76RL01830.

blends↗

Contributions of immunoaffinity chromatography to deep proteome profiling of human biofluids

Human biofluids, especially blood plasma or serum, hold great potential as the sources of potential biomarkers for various diseases; however, the enormous dynamic range of protein concentrations in biofluids represents a significant analytical challenge to detect promising low-abundance protein biomarkers. Over the last decade, various immunoaffinity chromatographic methods have been developed and routinely applied for separating low-abundance proteins from the high and moderate-abundance proteins, thus enabling more effective detection of low-abundance proteins. Herein, we review the advances of immunoaffinity separation methods and their contributions to the proteomics applications of different human biofluids. The limitations and future perspective of immunoaffinity separation methods are also discussed.

Environmental Molecular Sciences Laboratory↗