Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

On-Orbit Performance of the Adiabatic Demagnetization Refrigerator on XRISM

The X-ray Imaging and Spectroscopy Mission (XRISM) observatory was launched on Sep 7, 2023 from Tanegashima Space Center in Japan. Resolve, one its two instruments, performs high-resolution spectroscopy in the soft x-ray band (0.2-13 keV) using a 6x6 microcalorimeter array. The array cooled to 50 mK by a 3-stage ADR, which is linked to both a liquid helium dewar (at <1.2 K) and a Joule-Thomson (JT) cryocooler operating at <4.5 K. While liquid helium is present, two of the ADR stages provide detector cooling at 50 mK and auxiliary cooling to 0.5 K to intercept some parasitic heat loads, while rejecting waste heat to the helium. Once the helium is exhausted, Resolve enters a cryogen-free mode in which all three ADR stages are operated to provide detector cooling at 50 mK and to continuously cool the helium tank to 1.4 K. In this mode, waste heat is rejected to the JT cryocooler. Cryogen-free operation can be sustained as long as the JT and other cryocoolers remain fully operational. At launch, the helium tank contained approximately 35.6 liters of liquid. Within a few days, the helium cooled below 1.15 K, with an estimated 35.0 liters remaining. With an expected time average heat load of 0.68 mW, the helium lifetime was projected to exceed 4 years, but measurements of He volume on orbit suggest a significantly longer lifetime. Details of the ADR’s design and performance are presented.

x-ray astromony↗

Skylab program earth resouces experiment package. Volume 4: Sensor performance evaluation (S193 R/S)

The results of the sensor performance evaluation of the 13.9 GHz radiometer/scatterometer, which was part of the earth resources experiment package on Skylab. Findings are presented in the areas of housekeeping parameters, antenna gain and scanning performance, dynamic range, linearity, precision, resolution, stability, integration time, and transmitter output. Supplementary analyses covering performance anomalies, data stream peculiarities, aircraft sensor data comparisons, scatterometer saturation characteristics, and RF heating effects are reported. Results of the evaluation show that instrument performance was generally as expected, but capability degradations were observed to result from three major anomalies. Conclusions are drawn from the evaluation results, and recommendations for improving the effectiveness of a future program are offered. An addendum describes the special evaluation techniques developed and applied in the sensor performance evaluation tasks.

Kenney, G. P.↗

Towards Other Planetary Systems (TOPS): A technology needs identification workshop

The workshop identified a strong commonality between the technology needs for NASA's TOPS program and the technology needs that were identified for NASA's astrophysics program through its Astrotech 21 survey. The workshop encourages NASA to have the Solar System Exploration and Astrophysics Div. work cooperatively to share in technology studies that are common to both programs, rather than to conduct independent studies. It was also clear, however, that there are technology needs specific to TOPS, and these should be pursued by the Solar System Exploration Div. There are two technology areas that appear to be particularly critical to realizing the ultimate performance that is being sought under the TOPS program, these areas are metrology and optics. The former is critical in calibration and verification of instrument performance, while the latter is needed to provide optical systems of sufficient quality to conduct a search for and characterization of other planetary systems at the more extreme levels of performance identified in TOPS program.

Black, David C.↗

Direct Imaging and Spectroscopy of Exoplanetary Systems with the JWST Early Release Science Program

The direct characterization of exoplanetary systems with high contrast imaging is among the highest priorities for the broader exoplanet community. As large space missions will be necessary for detecting and characterizing exo-Earth twins, developing the techniques and technology for direct imaging of exoplanets is a driving focus for the community. For the first time, JWST will directly observe extrasolar planets at mid-infrared wavelengths beyond 5 μm, deliver detailed spectroscopy revealing much more precise chemical abundances and atmospheric conditions, and provide sensitivity to analogs of our solar system ice-giant planets at wide orbital separations, an entirely new class of exoplanet. However, in order to maximise the scientific output over the lifetime of the mission, an exquisite understanding of the instrumental performance of JWST is needed as early in the mission as possible. In this paper, we describe our 55-hour Early Release Science Program that will utilize all four JWST instruments to extend the characterisation of planetary mass companions to ∼15-20 μm as well as image a circumstellar disk in the mid-infrared with unprecedented sensitivity. Our program will also assess the performance of the observatory in the key modes expected to be commonly used for exoplanet direct imaging and spectroscopy, optimize data calibration and processing, and generate representative datasets that will enable a broad user base to effectively plan for general observing programs in future cycles.

Michael W McElwain↗

SeaWiFS Postlaunch Technical Report Series: The SeaBOARR-98 Field Campaign - Volume 3

This report documents the scientific activities during the first Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-Optical Algorithm Round-Robin (SeaBOARR-98) experiment, which took place from 5-17 July 1998, at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea off the coast of Italy. The ultimate objective of the SeaBOARR activity is to evaluate the effect of different measurement protocols on bio-optical algorithms using data from a variety of field campaigns. The SeaBOARR-98 field campaign was concerned with collecting a high quality data set of simultaneous in-water and above-water radiometric measurements. The deployment goals documented in this report were to: a) use four different surface glint correction methods to compute water-leaving radiances, L W (lambda), from above-water data; b) use two different in-water profiling systems and three different methods to compute L W (lambda) from in-water data (one making measurements at a fixed distance from the tower, 7.5 m, and the other at variable distances up to 29 m away); c) use instruments with a common calibration history to minimize intercalibration uncertainties; d) monitor the calibration drift of the instruments in the field with a second generation SeaWiFS Quality Monitor (SQM-II), to separate differences in methods from changes in instrument performance; and e) compare the L W (lambda) values estimated from the above-water and in-water measurements. In addition to describing the instruments deployed and the data collected, a preliminary analysis of the data is presented, and the kind of follow-on work that is needed to completely assess the estimation of L W (lambda) from above-water and in-water measurements is discussed.

Zibordi, Giuseppe↗

The CHARIS High-Contrast Integral-Field Spectrograph

One of the leading direct Imaging techniques, particularly in ground-based imaging, uses a coronagraphic system and integral field spectrograph (IFS). The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an IFS that has been built for the Subaru telescope. CHARIS has been delivered to the observatory and now sits behind the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. CHARIS has 'high' and 'low' resolution operating modes. The "high-resolution" mode is used to characterize targets in J, H, and K bands at ~R70. The "low-resolution" prism is meant for discovery and spans J+H+K bands (1.15-2.37 microns) with a spectral resolution of ~R18. This discovery mode has already proven better than 15-sigma detections of HR8799c,d,e when combining ADI+SDI. Using SDI alone, planets c and d have been detected in a single 24 second image. The CHARIS team is optimizing instrument performance and refining ADI+SDI recombination to maximize our contrast detection limit. In addition to the new observing modes, CHARIS has demonstrated a design with high robustness to spectral crosstalk. CHARIS is in the final stages of commissioning, with the instrument open for science observations beginning February 2017. Here we review the science case, design, on-sky performance, engineering observations of exoplanet and disk targets, and specific lessons learned for extremely high contrast imagers. Key design aspects that will be demonstrated are crosstalk optimization, wavefront correction using the IFS image, lenslet tolerancing, the required spectral resolution to fit exoplanet atmospheres, and the utility of the spectrum in achieving higher contrast detection limits.

Groff, Tyler D.↗

Failure detection and isolation methods for redundant gimballed inertial measurement units.

Skewed alignment of two redundant conventional inertial measuring units permits nonambiguous detection and isolation of hard and soft failures in real time by an airborne computer. Accelerometer outputs and gimbal readouts are monitored periodically, and attitude rate and velocity error vectors are computed from these data. Magnitudes of these vectors provide failure detection, and projection of these error vectors onto the coordinate axes of the two clusters permits isolation. A detailed Monte Carlo simulation of one version of the mechanization as applied to Space Shuttle boost trajectories demonstrates effectiveness down to very low levels of inertial instrument performance failures. The results indicate that worst case overall navigation performance occurs when accelerometer failures are of the order of 20 sigma and gyro failures are about 100 sigma for conventional state-of-the-art IMU instruments.

Solov, E. G.↗

Measuring Aerosol Size Distributions from the NASA DC-8 in SOLVE II

The University of Denver Focused Cavity Aerosol Spectrometer (FCAS 11) and Nucleation-Mode Aerosol Size Spectrometer (N-MASS) were successfully integrated and flown aboard NASA s DC-8 for the second SAGE I11 Ozone Loss and Validation Experiment (SOLVE 11). Both instruments performed well during SOLVE, with virtually complete data coverage for all mission and test flights. The few exceptions to this were the occasional simultaneous zero-check for the instruments, and some data loss for channel 4 of the N-MASS. The only consequence of the latter is reduced resolution in the 15 to 60 nm range for the affected size distributions.

Reeves, Michael↗

Satellite Instrument Calibration

Satellite remote sensing is an integral part of global earth observation. Satellite remote sensing data enable us to observe the whole globe at a reasonably high frequency. To maintain the accuracy of satellite remote sensing data, it is critical to continuously perform instrument calibration throughout the lifetime of the mission. This presentation describes the common characteristics of earth observing satellite sensors, the calibration processes and potential issues, the implication on science data, and how we understand the globe.

calibration↗

Comparisons of pilot performance in simulated and actual flight

Five highly experienced professional pilots performed instrument landing system approaches under simulated instrument flight conditions in a Cessna 172 airplane and in a Link-Singer GAT-1 simulator while under the influence of orally administered secobarbital (0, 100, and 200 mg). Tracking performance in two axes and airspeed control were evaluated continuously during each approach. Error and RMS variability were about half as large in the simulator as in the airplane. The observed data were more strongly associated with the drug level in the simulator than in the airplane. Further, the drug-related effects were more consistent in the simulator. Improvement in performance suggestive of learning effects were seen in the simulator, but not in actual flight.

Billings, C. E.↗

An Airborne A-Band Spectrometer for Remote Sensing Of Aerosol and Cloud Optical Properties

Atmospheric remote sensing with the O2 A-band has a relatively long history, but most of these studies were attempting to estimate surface pressure or cloud-top pressure. Recent conceptual studies have demonstrated the potential of spaceborne high spectral resolution O2 A-band spectrometers for retrieval of aerosol and cloud optical properties. The physical rationale of this new approach is that information on the scattering properties of the atmosphere is embedded in the detailed line structure of the O2 A-band reflected radiance spectrum. The key to extracting this information is to measure the radiance spectrum at very high spectral resolution. Instrument performance requirement studies indicate that, in addition to high spectral resolution, the successful retrieval of aerosol and cloud properties from A-band radiance spectra will also require high radiometric accuracy, instrument stability, and high signal-to-noise measurements. To experimentally assess the capabilities of this promising new remote sensing application, the NASA Langley Research Center is developing an airborne high spectral resolution A-band spectrometer. The spectrometer uses a plane holographic grating with a folded Littrow geometry to achieve high spectral resolution (0.5 cm-1) and low stray light in a compact package. This instrument will be flown in a series of field campaigns beginning in 2001 to evaluate the overall feasibility of this new technique. Results from these campaigns should be particularly valuable for future spaceborne applications of A-band spectrometers for aerosol and cloud retrievals.

Pitts, Michael↗

Laser altimetry measurements from aircraft and spacecraft

The techniques involved in the design and application of laser altimeter instruments are reviewed, including a description of the instrument subsystems required for the range and waveform measurements. Laser pulse transmitters based on the relatively novel technology of diode-pumped solid-state lasers are considered. Various factors affecting laser altimeter instrument performance are discussed. These include the receiver signal-to-noise ratio, atmospheric propagation, and altimeter platform effects. Some examples of laser altimeter data are presented to illustrate the variety of possible instrument applications.

Bufton, Jack L.↗

Calibration of the advanced microwave sounding unit-A for NOAA-K

The thermal-vacuum chamber calibration data from the Advanced Microwave Sounding Unit-A (AMSU-A) for NOAA-K, which will be launched in 1996, were analyzed to evaluate the instrument performance, including calibration accuracy, nonlinearity, and temperature sensitivity. The AMSU-A on NOAA-K consists of AMSU-A2 Protoflight Model and AMSU-A1 Flight Model 1. The results show that both models meet the instrument specifications, except the AMSU-A1 antenna beamwidths, which exceed the requirement of 3.3 +/- 10%. We also studied the instrument's radiometric characterizations which will be incorporated into the operational calibration algorithm for processing the in-orbit AMSU-A data from space. Particularly, the nonlinearity parameters which will be used for correcting the nonlinear contributions from an imperfect square-law detector were determined from this data analysis. It was found that the calibration accuracies (differences between the measured scene radiances and those calculated from a linear two-point calibration formula) are polarization-dependent. Channels with vertical polarizations show little cold biases at the lowest scene target temperature 84K, while those with horizontal polarizations all have appreciable cold biases, which can be up to 0.6K. It is unknown where these polarization-dependent cold biases originate, but it is suspected that some chamber contamination of hot radiances leaked into the cold scene target area. Further investigation in this matter is required. The existence and magnitude of nonlinearity in each channel were established and a quadratic formula for modeling these nonlinear contributions was developed. The model was characterized by a single parameter u, values of which were obtained for each channel via least-squares fit to the data. Using the best-fit u values, we performed a series of simulations of the quadratic corrections which would be expected from the space data after the launch of AMSU-A on NOAA-K. In these simulations, the cosmic background radiance corresponding to a cold space temperature 2.73K was adopted as one of the two reference points of calibration. The largest simulated nonlinear correction is about 0.3K, which occurs at channel 15 when the instrument temperature is at 38.09 deg C. Others are less than 0.2K in the remaining channels. Possible improvement for future instrument calibration is also discussed.

Mo, Tsan↗

FIRAS optical alignment and performance during vibration qualification and cryogenic cycling

NASA's Cosmic Background Explorer (COBE) is designed to investigate the Cosmic Background Radiation (CBR), that permeates the universe as a consequence of the Big Bang. This 3 degree Kelvin radiation is a fossil that contains much information about the early universe. The Far Infrared Absolute Spectrophotometer (FIRAS), will investigate the spectral isotropy of this ancient remnant and look for clues as to the subsequent evolution of the universe. The instrument is a cryogenically cooled, modified Michelson interferometer which operates in the 1 cm to 100 micron wavelength range. FIRAS is designed to provide absolute spectral information, therefore, all possible perturbations to the instrument response must be investigated to minimize distortions of the data. This paper discusses the methodology and resultant variations in the instrument performance noted during room temperature, and liquid nitrogen, (LN2) temperature vibration qualification. Reference alignment shifts in critical components such as the instrument wire-grid beamsplitter are correlated to changes in the instrument spectral response.

Hagopian, John G.↗

The Joint Winter Runway Friction Measurement Program

This paper provides background information, scope and objectives of a 5-year, Joint National Aeronautics & Space Administration (NASA)/Transport Canada (TC)/Federal Aviation Administration (FAA) Winter Runway Friction Measurement Program which has just completed its fourth winter season of testing. The test equipment, test sites, test results and accomplishments, the extent of the friction database compiled and future plans are described. The primary objective of this effort is to perform instrumented aircraft and ground vehicle tests aimed at identifying a "common number" that ground vehicle devices would report. This number denoted the International Runway Friction Index (IRFI) will be related to aircraft stopping performance. Several related studies are described including the effects of contaminant type on aircraft impingement drag and the effectiveness of various runway/aircraft chemical types and application rates. NASA considers the success of this program critical to insure adequate ground performance capability in adverse weather conditions for future aircraft as well as improving the safety of current aircraft ground operations.

Yager, Thomas J.↗

The Neutron Star Interior Composition Explorer (NICER): Design and Development

During 2014 and 2015, NASA's Neutron star Interior Composition Explorer (NICER) mission proceeded successfully through Phase C, Design and Development. An X-ray (0.2{12 keV) astrophysics payload destined for the International Space Station, NICER is manifested for launch in early 2017 on the Commercial Resupply Services SpaceX-11 flight. Its scientific objectives are to investigate the internal structure, dynamics, and energetics of neutron stars, the densest objects in the universe. During Phase C, flight components including optics, detectors, the optical bench, pointing actuators, electronics, and others were subjected to environmental testing and integrated to form the flight payload. A custom-built facility was used to co-align and integrate the X-ray \concentrator" optics and silicon-drift detectors. Ground calibration provided robust performance measures of the optical (at NASA's Goddard Space Flight Center) and detector (at the Massachusetts Institute of Technology) subsystems, while comprehensive functional tests prior to payload-level environmental testing met all instrument performance requirements. We describe here the implementation of NICER's major subsystems, summarize their performance and calibration, and outline the component-level testing that was successfully applied.

SEXTANT↗