Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of Gear Tooth Dynamic Friction

Measurements of dynamic friction forces at the gear tooth contact were undertaken using strain gages at the root fillets of two successive teeth. Results are presented from two gear sets over a range of speeds and loads. The results demonstrate that the friction coefficient does not appear to be significantly influenced by the sliding reversal at the pitch point, and that the friction coefficient values found are in accord with those in general use. The friction coefficient was found to increase at low sliding speeds. This agrees with the results of disc machine testing.

Rebbechi, Brian↗

Measurement of Gear Tooth Dynamic Friction

Measurements of dynamic friction forces at the gear tooth contact were undertaken using strain gages at the root fillets of two successive teeth. Results are presented from two gear sets over a range of speeds and loads. The results demonstrate that the friction coefficient does not appear to be significantly influenced by the sliding reversal at the pitch point, and that the friction coefficient values found are in accord with those in general use. The friction coefficient was found to increase at low sliding speeds. This agrees with the results of disc machine testing.

GEAR TEETH↗

International Space Station Future Correlation Analysis Improvements

Ongoing modal analyses and model correlation are performed on different configurations of the International Space Station (ISS). These analyses utilize on-orbit dynamic measurements collected using four main ISS instrumentation systems: External Wireless Instrumentation System (EWIS), Internal Wireless Instrumentation System (IWIS), Space Acceleration Measurement System (SAMS), and Structural Dynamic Measurement System (SDMS). Remote Sensor Units (RSUs) are network relay stations that acquire flight data from sensors. Measured data is stored in the Remote Sensor Unit (RSU) until it receives a command to download data via RF to the Network Control Unit (NCU). Since each RSU has its own clock, it is necessary to synchronize measurements before analysis. Imprecise synchronization impacts analysis results. A study was performed to evaluate three different synchronization techniques: (i) measurements visually aligned to analytical time-response data using model comparison, (ii) Frequency Domain Decomposition (FDD), and (iii) lag from cross-correlation to align measurements. This paper presents the results of this study.

time synchronization↗

A Feasibility Study on Use of an Accelerometer to Measure the Dynamic Forces in Turning

Metal cutting is a highly dynamic process that generates continuously varying forces. Measurement of these forces is essential to characterizing a cutting process and to fully utilize the machine tool. A force dynamometer is often used to measure these varying forces; however, it is limited by the natural frequency of the sensor and can sometimes be hard to set up on a machine. Therefore, this study aims to estimate the dynamic component of the cutting force using an accelerometer placed directly below the cutting edge. The placement of the sensor helps achieving better signal to noise ratio (S/N). The cutting tool is modelled as a single degree of freedom (SDOF) system relative to the workpiece and dynamic loads are experimentally simulated on it. The measured acceleration is numerically integrated to obtain velocity and deflection, which along with the natural frequency (ω n ) and damping ratio (ζ), is used to predict the dynamic load using the system equation. The dynamic forces tested over a wide range of frequencies, show good agreement with the data from simultaneous dynamometer measurement and the force estimated using the proposed method. The study shows the feasibility of this method in a real cutting scenario and the capability to apply it to a multi DOF system. One major limitation is the inability to capture the static or quasi-static component of the cutting force.

Cutting vibrations↗

Thermospheric neutral wind signatures dependent on the east-west component of the interplanetary magnetic field for Northern and Southern Hemispheres as measured from Dynamics Explorer-2

DE-2 neutral-wind measurements obtained between November and January 1981-1982 and 1982-1983 were analyzed to investigate the effect of the sign of the IMF By component on neutral thermosphere dynamics at F-region altitudes. Maps of the mean neutral circulation for the northern (winter) and southern (summer) polar regions were derived for By positive and negative using polar geomagnetic coordinates. The mean neutral winds demonstrate clear By-dependent neutral wind signatures in both hemispheres.

Thayer, J. P.↗

Ionospheric plasma cloud dynamics

Measurements of the thermospheric neutral wind and ionospheric drift made at Eglin AFB, Florida and Kwajalein Atoll are discussed. The neutral wind measurements at Eglin had little variation over a period of four years for moderate magnetic activity (Kp 4); the ionospheric drifts are small. Evidence is presented that indicates that increased magnetic activity has a significant effect on the neutral wind magnitude and direction at this midlatitude station. The neutral wind at dusk near the equator is generally small although in one case out of seven it was significantly larger. It is described how observations of large barium releases can be used to infer the degree of electrodynamic coupling of ion clouds to the background ionosphere. Evidence is presented that indicates that large barium releases are coupled to the conjugate ionosphere at midlatitudes.

Source record↗

Dynamic thermophysical measurements in space

The objective is to develop an accurate dynamic technique which, in a microgravity environment, would enable performance of thermophysical measurements on high-melting-point electrically conducting substances in their liquid state. In spite of the critical need in high temperature technologies related to spacecraft, nuclear reactors, effects of power laser radiation, and in validating theoretical models in related areas, no accurate data on thermophysical properties exist. This is primarily due to the limitation of the reliable steady-state techniques to temperatures below about 2000 K, and the accurate millisecond-resolution pulse heating techniques to the solid state of the specimen. The limitation of the millisecond-resolution techniques to temperatures below the melting point stems from the fact that the specimen collapses due to the gravitational force once it starts to melt. The rationale for the use of the microgravity is that by performing the dynamic experiments in a microgravity environment the specimen will retain its geometry, and thus it will be possible to extend the accurate thermophysical measurements to temperatures above the melting point of high-melting-point substances.

Cezairliyan, Ared↗

Experimental Validation of the Dynamic Inertia Measurement Method to Find the Mass Properties of an Iron Bird Test Article

The mass properties of an aerospace vehicle are required by multiple disciplines in the analysis and prediction of flight behavior. Pendulum oscillation methods have been developed and employed for almost a century as a means to measure mass properties. However, these oscillation methods are costly, time consuming, and risky. The NASA Armstrong Flight Research Center has been investigating the Dynamic Inertia Measurement, or DIM method as a possible alternative to oscillation methods. The DIM method uses ground test techniques that are already applied to aerospace vehicles when conducting modal surveys. Ground vibration tests would require minimal additional instrumentation and time to apply the DIM method. The DIM method has been validated on smaller test articles, but has not yet been fully proven on large aerospace vehicles.

moments of inertia↗

Static and dynamic pressure measurements on a NACA 0012 airfoil in the Ames High Reynolds Number Facility

The supercritical flows at high subsonic speeds over a NACA 0012 airfoil were studied to acquire aerodynamic data suitable for evaluating numerical-flow codes. The measurements consisted primarily of static and dynamic pressures on the airfoil and test-channel walls. Shadowgraphs were also taken of the flow field near the airfoil. The tests were performed at free-stream Mach numbers from approximately 0.7 to 0.8, at angles of attack sufficient to include the onset of buffet, and at Reynolds numbers from 1 million to 14 million. A test action was designed specifically to obtain two-dimensional airfoil data with a minimum of wall interference effects. Boundary-layer suction panels were used to minimize sidewall interference effects. Flexible upper and lower walls allow test-channel area-ruling to nullify Mach number changes induced by the mass removal, to correct for longitudinal boundary-layer growth, and to provide contouring compatible with the streamlines of the model in free air.

Mcdevitt, J. B.↗

Pressure Probe Designs for Dynamic Pressure Measurements in a Supersonic Flow Field

A series of dynamic flow field pressure probes were developed for use in large-scale supersonic wind tunnels at NASA Glenn Research Center. These flow field probes include pitot, static, and five-hole conical pressure probes that are capable of capturing fast acting flow field pressure transients that occur on a millisecond time scale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The five-hole conical pressure probes are used primarily to determine local flow angularity, but can also determine local Mach number. These probes were designed, developed, and tested at the NASA Glenn Research Center. They were also used in a NASA Glenn 10- by 10-Foot Supersonic Wind Tunnel (SWT) test program where they successfully acquired flow field pressure data in the vicinity of a propulsion system during an engine compressor stall and inlet unstart transient event. Details of the design, development, and subsequent use of these probes are discussed in this report.

Porro, A. Robert↗

Mass properties measurement system dynamics

The MPMS mechanism possess two revolute degrees-of-freedom and allows the user to measure the mass, center of gravity, and the inertia tensor of an unknown mass. The dynamics of the Mass Properties Measurement System (MPMS) from the Lagrangian approach to illustrate the dependency of the motion on the unknown parameters.

Doty, Keith L.↗

A comparison of Raman and pyrometry dynamic temperature measurements of shocked cyclohexane

Optical pyrometry is a well-developed, broadly applicable method to determine temperature in dynamic compression experiments. However, it measures radiation from only the skin depth of the radiant material, is highly susceptible to spurious backgrounds, and requires an often-unmeasurable free parameter—the sample dynamic emissivity. Raman spectroscopy offers a method to determine temperature directly from fundamental theory, but it is practically limited in applications to a small subset of shock experiments. In this work, we describe an experiment allowing simultaneous application of Raman and pyrometric temperature techniques to benchmark a specific instance of pyrometry. We attempted both measurements on multiple experiments and compare the successful temperature results between the separate but highly repeatable shots. Here, we find that dynamic shock temperatures inferred from Raman spectroscopy and pyrometry generally agree within the uncertainties of each measurement, although those uncertainties are larger than typical for a specially designed pyrometry experiment on a shocked metal sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

Unsteady-Pressure and Dynamic-Deflection Measurements on an Aeroelastic Supercritical Wing

Transonic steady and unsteady pressure tests were conducted on a large elastic wing. The wing has a supercritical airfoil, a full span aspect ratio of 10.3, a leading edge sweepback angle of 28.8 degrees, and two inboard and one outboard trailing edge control surfaces. Only the outboard control surface was deflected statically and dynamically to generate steady and unsteady flow over the wing. The unsteady surface pressure and dynamic deflection measurements of this elastic wing are presented to permit correlations of the experimental data with theoretical predictions.

Seidel, David A.↗

Hot dynamic test rig for measuring hypersonic engine seal flow and durability

A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts was developed. The test fixture was developed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C and air pressure differentials of to 0.7 MPa. Performance of the seals can be measured while sealing against flat or engine-simulated distorted walls. In the fixture, two seals are preloaded against the sides of a 0.3 m long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. The capabilities of this text fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling are covered.

Miller, Jeffrey H.↗