Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Application of satellite time transfer in autonomous spacecraft clocks

The conceptual design of a spacecraft clock that will provide a standard time scale for experimenters in future spacecraft., and can be sychronized to a time scale without the need for additional calibration and validation is described. The time distribution to the users is handled through onboard computers, without human intervention for extended periods. A group parallel binary code, under consideration for onboard use, is discussed. Each group in the code can easily be truncated. The autonomously operated clock not only achieves simpler procedures and shorter lead times for data processing, but also contributes to spacecraft autonomy for onboard navigation and data packetization. The clock can be used to control the sensor in a spacecraft, compare another time signal such as that from the global positioning system, and, if the cost is not a consideration, can be used on the ground in remote sites for timekeeping and control.

Chi, A. R.↗

Navstar Global Positioning System (GPS) clock program: Present and future

Global Positioning System (GPS) program status are discussed and plans for ensuring the long term continuation of the program are presented. Performance of GPS clocks is presented in terms of on orbit data as portrayed by GPS master control station kalman filter processing. The GPS Clock reliability program is reviewed in depth and future plans fo the overall clock program are published.

Tennant, D. M.↗

Comparison of VLBI, TV and traveling clock techniques for time transfer

A three part experiment was conducted to develop and compare time transfer techniques. The experiment consisted of (1) a very long baseline interferometer (VLBI), (2) a high precision portable clock time transfer system between the two sites, and (3) a television time transfer. A comparison of the VLBI and traveling clock shows each technique can perform satisfactorily at the five nsec level. There was a systematic offset of 59 nsec between the two methods, which we attributed to a difference in epochs between VLBI formatter and station clock. The VLBI method had an internal random error of one nsec at the three sigma level for a two day period. Thus, the Mark II system performed well, and VLBI shows promise of being an accurate method of time transfer. The TV system, which had technical problems during the experiment, transferred time with a random error of about 50 nsec.

Spencer, J. H.↗

Elemental technetium as a cosmic-ray clock

Several radioactive isotopes have been proposed as clocks for the study of the mean cosmic ray confinement time, T sub e. Measurements of Be-10 and Al-26 give a value for T sub e of about 10 Myr when one uses a leaky box cosmic ray propagation model. It is important to obtain additional measurements of T sub e from other radioactive isotopes in order to check whether the confinement is the same throughout the periodic table. The possible use of Tc (Z = 43) as a cosmic clock is investigated. Since all isotopes of Tc are radioactive, one might be able to group these isotopes and use the elemental abundance as a whole. The results of the calculations are somewhat inconclusive for two reasons. First, the beta + decay half lives of two of the Tc isotopes relevant to our calculation are not known. Second, the dependence of the Tc abundance on the mean confinement time is rather weak when one considers the number of events expected in 4 trays of plastic track detectors. However, a future, finite measurement of the Beta + half lives and the possible use of the entire collecting area of the HNC to detect Tc nuclei could make the use of Tc as a cosmic ray clock more attractive.

Drach, J.↗

Fault-tolerant clock synchronization validation methodology

A validation method for the synchronization subsystem of a fault-tolerant computer system is presented. The high reliability requirement of flight-crucial systems precludes the use of most traditional validation methods. The method presented utilizes formal design proof to uncover design and coding errors and experimentation to validate the assumptions of the design proof. The experimental method is described and illustrated by validating the clock synchronization system of the Software Implemented Fault Tolerance computer. The design proof of the algorithm includes a theorem that defines the maximum skew between any two nonfaulty clocks in the system in terms of specific system parameters. Most of these parameters are deterministic. One crucial parameter is the upper bound on the clock read error, which is stochastic. The probability that this upper bound is exceeded is calculated from data obtained by the measurement of system parameters. This probability is then included in a detailed reliability analysis of the system.

Computer systems↗

Transmission delays in hardware clock synchronization

Various methods, both with software and hardware, have been proposed to synchronize a set of physical clocks in a system. Software methods are very flexible and economical but suffer an excessive time overhead, whereas hardware methods require no time overhead but are unable to handle transmission delays in clock signals. The effects of nonzero transmission delays in synchronization have been studied extensively in the communication area in the absence of malicious or Byzantine faults. The authors show that it is easy to incorporate the ideas from the communication area into the existing hardware clock synchronization algorithms to take into account the presence of both malicious faults and nonzero transmission delays.

Shin, Kang G.↗

Slot clock recovery in optical PPM communication systems with avalanche photodiode photodetectors

Slot timing recovery in a direct-detection optical PPM communication system can be achieved by processing the photodetector output waveform with a nonlinear device whose output forms the input to a phase-locked loop. The choice of a simple transition detector as the nonlinearity is shown to give satisfactory synchronization performance. The rms phase error of the recovered slot clock and the effect of slot timing jitter on the bit error probability were directly measured. The experimental system consisted of an AlGaAs laser diode (wavelength = 834 nm) and a silicon avalanche photodiode photodetector. The system used Q = 4 PPM signaling and operated at a source data rate of 25 Mbits/s. The mathematical model developed to compute the rms phase error of the recovered clock is shown to be in good agreement with results of actual measurements of phase errors. The use of the recovered slot clock in the receiver resulted in no significant degradation in receiver sensitivity compared to a system with perfect slot timing. The system achieved a bit error probability of 10 to the -6th at a received optical signal energy of 55 detected photons per information bit.

Davidson, Frederic M.↗

Mechanical proofs of fault-tolerant clock synchronization

The following topics are covered in viewgraph form: (1) introduction to clock synchronization protocols; (2) a schematic formulation of clock synchronization; (3) the interactive convergence algorithm; (4) verification of Schneider's formulation; (5) verification of interactive convergence; (6) a hardware-oriented clock synchronization protocol; (7) verification of Infis/Moore's protocol; and (8) the EHDM specification/verification environment.

Shankar, N.↗

Synchronizing computer clocks using a local area network

Researchers completed the first tests of a method to synchronize the clocks of networked computers to the National Institute of Standards and Technology (NIST) time scale. The method uses a server computer to disseminate the time to other clients on the same local-area network. The server is synchronized to NIST using the ACTS protocol over a dial-up telephone line. The software in both the server and the parameters of this model are used to adjust the time of the local clock and the interval between calibration requests in a statistically optimum way. The algorithm maximizes the time between calibrations while at the same time keeping the time of the local clock correct within a specific tolerance. The method can be extended to synchronize computers linked over wide-area networks, and an experiment to test the performance of the algorithms over such networks is being planned.

Levine, Judah↗

Atomic Clock Based On Linear Ion Trap

Highly stable atomic clock based on excitation and measurement of hyperfine transition in 199Hg+ ions confined in linear quadrupole trap by radio-frequency and static electric fields. Configuration increases stability of clock by enabling use of enough ions to obtain adequate signal while reducing non-thermal component of motion of ions in trapping field, reducing second-order Doppler shift of hyperfine transition. Features described in NPO-17758 "Linear Ion Trap for Atomic Clock." Frequency standard based on hyperfine transition described in NPO-17456, "Trapped-Mercury-Ion Frequency Standard."

Prestage, John D.↗

Using the USCCS for sub microsecond spacecraft clock calibration

The Return Data Delay technique which requires knowledge of spacecraft range is commonly used for correlating a spacecraft clock against a ground time standard when millisecond accuracy is required. An analysis is presented that allows using the user spacecraft clock calibration system (USCCS) to correlate a spacecraft clock to better than one microsecond accuracy. The basic USCCS algorithm has been simplified and it is shown to result in about one microsecond accuracy without requiring orbital information. By considering the relative motion of the user satellite, the TDRS and the earth station about the center of the earth, a correction of almost two orders of magnitude can be made. Such accuracy is required for scientific investigations that require correlating coincident radiation or particle detection with a remote laboratory.

Sank, Victor J.↗

Gravitational Wave Search with the Clock Mission

Doppler tracking of distant spacecraft is the only method currently available to search for gravitational waves in the low-frequency (approx. 0.0001-0.1 Hz) band. In this technique the Doppler system measures the relative dimensionless velocity 2(delta)v/c = (delta)f/f(sub o) between the earth and the spacecraft as a function of time, where (delta)f is the frequency perturbation and f(sub o) is the nominal frequency of the radio link. A gravitational wave of amplitude h incident on this system causes small frequency perturbations, of order h in (delta)f/f(sub o), replicated three times in the observed record (Estabrook and Wahlquist 1975). All experiments to date and those planned for the near future involve only 'two-way' Doppler-i.e., uplink signal coherently transponded by the spacecraft with Doppler measured using a frequency standard common to the transmit and receive chains of the ground station. If, as on the proposed Clock Mission, there is an additional frequency standard on the spacecraft and a suitable earth-spacecraft radio system, some noise sources can be isolated and removed from the data (Vessot and Levine 1978). Supposing that the Clock Mission spacecraft is transferred into a suitable interplanetary orbit, I discuss here how the on-board frequency standard could be employed with an all-Ka-band radio system using the very high stability Deep Space Network station DSS 25 being instrumented for Cassini. With this configuration, the Clock Mission could search for gravitational waves at a sensitivity limited by the frequency standards, rather than plasma or tropospheric scintillation effects, whenever the sun-earth-spacecraft angle is greater than 90 degrees.

Armstrong, J. W.↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗

An Adaptive Method for Reducing Clock Skew in an Accumulative Z-Axis Interconnect System

This paper will present several methods for adjusting clock skew variations that occur in a n accumulative z-axis interconnect system. In such a system, delay between modules in a function of their distance from one another. Clock distribution in a high-speed system, where clock skew must be kept to a minimum, becomes more challenging when module order is variable before design.

Bolotin, Gary↗

Higher Pole Linear Traps for Atomic Clock Applications

We investigate experimentally and theoretically higher pole linear ion traps for frequency standard use. We have built a 12-pole trap and have successfully loaded ions into it from a linear quadrupole trap. By solving the Boltzmann equation describing large ion clouds where space charge interactions are important, we show that clock frequency changes due to ion number fluctuations are much smaller in ion clocks based multipole traps than comparable clocks based on quadrupole linear traps.

Prestage, John D.↗

Microwave Cavity Clocks On Space Station

We describe the status of a microwave cavity clock experiment to perform improved tests of Local Position Invariance and Lorentz Invariance on the International Space Station in conjunction with atomic clocks. Significant improvements over present bounds are expected in both cases. The oscillators can also be used to enhance the performance of atomic clocks at short time scales for other experiments.

Lipa, J. a.↗

Small Mercury Ion Clock for On-board Spacecraft Navigation

I.Small Ion Clock Approach and Heritage: a) No lasers, uwave cavities, cryogenics, atomic beams, etc. b) Ions are electrically shuttled between separate optical and microwave traps. II. Each trap is optimized for its task: quadrupole for optical state selection; multi-pole for microwave clock. a) Very good stability shown in USNO. Timescale running "open loop." III. "Open loop" operation means no self-measurements of frequency offsets: (Zeeman, ion temperature,... etc.) a) Fewer parts and procedures, produces stable output continuously. IV. Ion clock is not so sensitive to temperature fluctuations a) Measured u:nshielded temperature coefficient of few 10(exp -15) per C. b) No bulky temperature isolation needed.

Prestage, John D.↗

Synchronous clock stopper for microprocessor

A synchronous clock stopper circuit for inhibiting clock pulses to a microprocessor in response to a stop request signal, and for reinstating the clock pulses in response to a start request signal thereby to conserve power consumption of the microprocessor when used in an environment of limited power. The stopping and starting of the microprocessor is synchronized, by a phase tracker, with the occurrences of a predetermined phase in the instruction cycle of the microprocessor in which the I/O data and address lines of the microprocessor are of high impedance so that a shared memory connected to the I/O lines may be accessed by other peripheral devices. The starting and stopping occur when the microprocessor initiates and completes, respectively, an instruction, as well as before and after transferring data with a memory. Also, the phase tracker transmits phase information signals over a bus to other peripheral devices which signals identify the current operational phase of the microprocessor.

Kitchin, David A.↗