Engineering Papers⌕ Search

NASA NTRS · 19920000503

Atomic Clock Based On Linear Ion Trap

Abstract

Highly stable atomic clock based on excitation and measurement of hyperfine transition in 199Hg+ ions confined in linear quadrupole trap by radio-frequency and static electric fields. Configuration increases stability of clock by enabling use of enough ions to obtain adequate signal while reducing non-thermal component of motion of ions in trapping field, reducing second-order Doppler shift of hyperfine transition. Features described in NPO-17758 "Linear Ion Trap for Atomic Clock." Frequency standard based on hyperfine transition described in NPO-17456, "Trapped-Mercury-Ion Frequency Standard."

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Prestage, John D., Dick, G. John. 1992-09-01. Atomic Clock Based On Linear Ion Trap. https://engineeringpapers.com/record/nasa%3A19920000503/atomic-clock-based-on-linear-ion-trap