Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

System and method for fissionable material detection with a short pulse neutron source

A system and method is disclosed for detecting fissionable materials. In one embodiment the system may incorporate a neutron pulse generator configured to generate multiple short pulses of neutrons, or a single pulse of sufficient intensity, in a vicinity of an object of interest. The source pulse of neutrons includes neutrons which each have a full width half maximum time duration of less than about 100 ns and a peak energy level no greater than about 20 MeV. A fast response detector is used which is able to detect single neutron events indicative of fission neutrons having been produced by the source pulse of neutrons interacting with fissionable material associated with the object of interest, and which arrive at the fast response detector within a predetermined time window immediately before arrival of the source neutron pulses.

Podpaly, Yuri↗

Precise delay measurement through combinatorial logic

A high resolution circuit and method for facilitating precise measurement of on-chip delays for FPGAs for reliability studies. The circuit embeds a pulse generator on an FPGA chip having one or more groups of LUTS (the "LUT delay chain"), also on-chip. The circuit also embeds a pulse width measurement circuit on-chip, and measures the duration of the generated pulse through the delay chain. The pulse width of the output pulse represents the delay through the delay chain without any I/O delay. The pulse width measurement circuit uses an additional asynchronous clock autonomous from the main clock and the FPGA propagation delay can be displayed on a hex display continuously for testing purposes.

Burke, Gary R.↗

Implantable Heart Aid

Medrad utilized NASA's Apollo technology to develop a new device called the AID implantable automatic pulse generator which monitors the heart continuously, recognizes the onset of ventricular fibrillation and delivers a corrective electrical shock. AID pulse generator is, in effect, a miniaturized version of the defibrillator used by emergency squads and hospitals to restore rhythmic heartbeat after fibrillation, but has the unique advantage of being permanently available to the patient at risk. Once implanted, it needs no specially trained personnel or additional equipment. AID system consists of a microcomputer, a power source and two electrodes which sense heart activity.

Source record↗

Demonstration of an intense lithium beam for forward-directed pulsed neutron generation

Abstract As an alternative to research nuclear reactors, a compact accelerator-driven neutron generator that uses a lithium beam driver could be a promising candidate since it produces almost no undesired radiation. However, providing an intense lithium-ion beam has been difficult, and it has been thought that the practical application of such a device would be impossible. The most critical problem of insufficient ion fluxes has been solved by applying a direct plasma injection scheme. In this scheme, a pulsed high-density plasma from a metallic lithium foil generated by laser ablation is efficiently injected and accelerated by a radio-frequency quadrupole linear accelerator (RFQ linac). We have obtained a peak beam current of 35 mA accelerated to 1.43 MeV, which is two orders of magnitude higher than a conventional injector and accelerator system can deliver.

43 PARTICLE ACCELERATORS↗

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Waves of Electric Charge Generated by Pulse Corona of Alternating Polarity

The project contributes to DoE Office of Science program “Opportunities in Frontier Plasma Science” by providing plasma science experiments at the Princeton Collaborative Research Facility (PCRF) – the Princeton Plasma Physics Laboratory. The research consisted of - extensive experimental/simulation studies of a pulse corona discharge pattern and dynamics performed at the University of Notre Dame; - non-intrusive measurements of electric field distribution and dynamics performed at PCRF by the method employing Electric Field-Induced Second Harmonic Generation (EFISH); and - analysis of the data acquired.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

Efficient generation of the 7th harmonic of Ti:sapphire (114.6 nm) vacuum ultraviolet pulses with 60 fs duration by non-collinear four-wave mixing in argon

The recent advances in femtosecond vacuum UV (VUV) pulse generation, pioneered by the work of Noack et al., has enabled new experiments in ultrafast time-resolved spectroscopy. Expanding on this work, we report the generation of 60 fs VUV pulses at the 7th harmonic of Ti:sapphire with more than 50 nJ of pulse energy at a repetition rate of 1 kHz. Additionally, the 114.6 nm pulses are produced using non-collinear four-wave difference-frequency mixing in argon. The non-collinear geometry increases the phase-matching pressure, and results in a conversion efficiency of ~10-3 from the 200 nm pump beam. The VUV pulses are pre-chirp-compensated for material dispersion with xenon, which has negative dispersion in this wavelength range, thus allowing almost transform-limited pulses to be delivered to the experimental chamber.

36 MATERIALS SCIENCE↗

Magnetically switched power supply system for lasers

A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

Pacala, Thomas J.↗