Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Wide Operational Windows of Edge-Localized Mode Suppression by Resonant Magnetic Perturbations in the DIII-D Tokamak

Edge-Localized-Mode (ELM) suppression by resonant magnetic perturbations (RMPs) generally occurs over very narrow ranges of the plasma current (or magnetic safety factor $q_{95}$) in the DIII-D tokamak. However, wide $q_{95}$ ranges of ELM suppression are needed for the safety and operational flexibility of ITER and future reactors. In DIII-D ITER Similar Shape (ISS) plasmas with $n$=3 RMPs, the range of $q_{95}$ for ELM suppression is found to increase with decreasing electron density. Nonlinear two-fluid MHD simulations reproduce the observed $q_{95}$ windows of ELM suppression and the dependence on plasma density, based on the conditions for resonant field penetration at the top of the pedestal. When the RMP amplitude is close to the threshold for resonant field penetration, only narrow isolated magnetic islands form near the top of the pedestal, leading to narrow $q_{95}$ windows of ELM suppression. However, as the threshold for field penetration decreases with decreasing density, resonant field penetration can take place over a wider range of $q_{95}$. For sufficiently low density (penetration threshold) multiple magnetic islands form near the top of the pedestal giving rise to continuous $q_{95}$ windows of ELM suppression. The model predicts that wide $q_{95}$ windows of ELM suppression can be achieved at substantially higher pedestal pressure in DIII-D by shifting to higher toroidal mode number ($n$=4) RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of resonant magnetic perturbations on radial electric fields in DIII-D tokamak

Here, gyrokinetic simulations of DIII-D tokamak equilibrium find that resonant magnetic perturbation (RMP) drives a neoclassical non-ambipolar electron particle flux, which causes a rapid change of equilibrium radial electric fields consistent with experimental observations during the suppression of the edge localized mode (ELM). The simulation results provide a support for the conjecture that RMP-induced changes of radial electric fields lead to the enhanced turbulent transport at the pedestal top during the ELM suppression (Taimourzadeh et al 2019 Nucl. Fusion 59 046005). Furthermore, gyrokinetic simulations of collisionless damping of zonal flows show that resonant responses to the RMP decrease the residual level of the zonal flows and damp the geodesic acoustic mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Robust Magnetic Resonance Imager For Ground and Flight Based Measurements of Fluid Physics Phenomena

Nuclear magnetic resonance (NMR) is a powerful and versatile, noninvasive method for studying fluid transport problems, However, its applications to these types of investigations have been limited. A primary factor that limits the application of NMR has been the lack of a user-friendly, versatile, and inexpensive NMR imaging apparatus that can be used by scientists who are not familiar with sophisticated NMR. To rectify this situation, we developed a user-friendly, NMR imager for projects of relevance to the MRD science community. To that end, we performed preliminary collaborative experiments between NASA, NCMR, and New Mexico Resonance in the high field NMR set up at New Mexico Resonance to track wetting front dynamics in foams under gravity. The experiments were done in a 30 cm, 1.9T Oxford magnet with a TECMAG Libra spectrometer (Tecmag, Inc., Houston, TX). We used two different imaging strategies depending on whether the water in the foam sample was static or moving. Stationary water distributions were imaged with the standard Fourier imaging method, as used in medical MRI, in which data are acquired from all parts of the region of interest at all times and Fourier transformed into a static spatial image.

Source record↗

Effect of resonant magnetic perturbations including toroidal sidebands on magnetic footprints and fast ion losses in HL-2M

Externally applied resonant magnetic perturbations (RMPs), generated by magnetic coils located outside the plasma (referred to as RMP coils), provide an effective way to control the edge localized mode (ELM) in tokamak devices. Due to the discrete nature of the toroidal distribution of these window-frame coils, toroidal sidebands always exist together with the fundamental harmonics designed for ELM control. In this work, the MARS-F code (Liu et al 2000 Phys. Plasmas7 3681) is applied to investigate the detailed features of the RMP spectra considering both the dominant harmonic (n = 2) and the associated sideband (n = 6), and the impact of the combined fields on magnetic footprints as well as on the fast ion losses for a reference double-null scenario in the HL-2M device. It is found that the sum of the n = 2 and n = 6 RMP fields splits the footprint and widens the footprint area, as compared to the single-n (n = 2) harmonic case. The resistive plasma response breaks the up–down symmetry of the footprint pattern on the outer divertor plates, which is otherwise symmetric assuming vacuum RMP fields. Considering fast ion losses, a threshold value exists for the initially launched radial position of test particles, as well as for the RMP coil current, before the loss occurs. When the threshold criterion is satisfied, the combined n = 2 and n = 6 RMP fields enhance the fast ion loss rate by , as compared to that of the n = 2 component alone. These results illustrate the important role of the sideband of RMP fields on the magnetic footprints and fast ion losses in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal collapse by resonant magnetic perturbations

Pedestal collapse (i.e., the complete loss of the edge transport barrier (ETB)) in DIII-D H-mode plasmas occurs when resonant magnetic perturbations (RMPs) penetrate the steep gradient region at the plasma edge. Normally, RMP driven magnetic islands can occur at the top and bottom of the H-mode pedestal and these islands generate conditions consistent with edge-localized-mode (ELM) suppression and density pump-out, respectively, based on nonlinear two-fluid MHD simulations. In contrast, MHD simulations show that the steep pressure gradient region between the top and bottom of the DIII-D pedestal is generally immune to resonant field penetration due to large local E × B and diamagnetic flows. By this fortuitous circumstance, the edge-transport-barrier and H-mode confinement can be maintained while achieving ELM suppression. However, pedestal collapse can occur in DIII-D when the screening flows are inadequate to prevent field penetration in the steep gradient region of the pedestal. Non-linear two-fluid MHD simulations support the role of resonant field penetration in pedestal collapse for DIII-D H-mode plasmas with weak edge E × B and diamagnetic screening flows. ITER will likely have weaker edge screening flows than present experiments due to its much larger size, making it more susceptible to resonant field penetration in the steep gradient region of the pedestal. Analysis of model ITER equilibria demonstrates that resonant field penetration in the steep pressure gradient region is possible for RMP levels of the order required for ELM suppression. The effect of such penetration on the ITER pedestal will depend sensitively on the resulting degree of island overlap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

Clustering Nuclear Magnetic Resonance: Machine learning assistive rapid two‐dimensional relaxometry mapping

Abstract Low‐field nuclear magnetic resonance (NMR) relaxometry is an attractive approach from point‐of‐care testing medical diagnosis to in situ oil‐gas exploration. One of the problems, however, is the inherently long relaxation time of the (liquid) samples, (and hence low signal‐to‐noise ratio) which causes unnecessarily long repetition time. In this work, a new class of methodology is presented for rapid and accurate object classification using NMR relaxometry with the aid of machine learning. It is demonstrated that the sensitivity and specificity of the classification is substantially improved with higher order of (pseudo)‐dimensionality (e.g., 2D‐ or multi‐dimensional). This new methodology (termed as ‘Clustering NMR’) may be extremely useful for rapid and accurate object classification (in less than a minute) using low‐field NMR.

Peng, Weng Kung↗

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method for analyzing the kinematics of joint motion using magnetic resonance imaging (MRI) is described. The reconstruction of the metacarpalphalangeal joint of the left index finger into a 3D graphic display is shown. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones are obtained and processed by analyzing the screw motion of the joint. Landmark positions are chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily 2D planar motion of this joint is then studied using a method of constructing coordinate systems using three or more points. A transformation matrix based on a world coordinate system describes the location and orientation of the local target coordinate system. The findings show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove design for EVA.

Dickenson, Reuben D.↗

Toward holistic understanding of the ITER-like resonant magnetic perturbation (RMP) ELM control on KSTAR

Here, KSTAR has clarified a set of unresolved 3D physics issues utilizing the ITER-like in-vessel, three-row, resonant magnetic perturbation (RMP) configurations. Since RMP-driven, edge-localized-modes (ELMs)-crash control elevates the divertor heat flux peak through its impact on edge plasma parameters and transport, a series of intentionally misaligned RMP configurations (IMCs) have been explored to investigate the relationship between RMP ELM control and divertor heat fluxes, while searching for an ideal IMC that could be favorable in both aspects. First of all, the contrasting influence of kink vs anti-kink phasing on the ELM-crash suppression has been articulated, demonstrating the synergistic benefit of 'kink' phasing on ELM-crash-suppression. On the other hand, the three-row IMC in the anti-kink phasing becomes more insensitive to the ELM-crashes at the sub-marginal level of RMP, consistent with theory. Meanwhile, the divertor 'wetted' area of ELM-crash-suppression gets narrower than that of ELM-crash-mitigation, suggesting that ELM-crash-mitigation remains advantageous over ELM-crash-suppression in terms of time-averaged divertor thermal loading. In comparison, based on a set of two-row IMCs, no evidence of divertor heat flux broadening was found during ELM-crash-suppression, supporting a hypothesis that the dispersal of the divertor heat flux in three-row IMCs cannot be driven by helically structured two-row RMPs alone. Among ITER-like three-rows, lower two-row RMPs have been found to be much more effective in suppressing the ELM-crashes than upper two-row RMPs. Although it is quite preliminary, the up/down asymmetric dependence of RMP coupling may be generically attributed to lower-single-null plasmas. Such a holistic understanding of RMP-driven, ELM-crash-control in KSTAR is expected not only to elucidate various subtle points in the vicinity of ELM-crash-suppression, but also to clarify the relevant divertor thermal loading issues for ITER and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement

It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.

Manatt, Stanley L.↗

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method of analyzing the kinematics of joint motion is developed. Magnetic Resonance Imaging (MRI) offers several distinct advantages. Past methods of studying anatomic joint motion have usually centered on four approaches. These methods are x-ray projection, goniometric linkage analysis, sonic digitization, and landmark measurement of photogrammetry. Of these four, only x-ray is applicable for in vivo studies. The remaining three methods utilize other types of projections of inter-joint measurements, which can cause various types of error. MRI offers accuracy in measurement due to its tomographic nature (as opposed to projection) without the problems associated with x-ray dosage. Once the data acquisition of MR images was complete, the images were processed using a 3D volume rendering workstation. The metacarpalphalangeal (MCP) joint of the left index finger was selected and reconstructed into a three-dimensional graphic display. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones were obtained and processed by analyzing the screw motion of the MCP joint. Landmark positions were chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily two dimensional planar motion of this joint was then studied using a method of constructing coordinate systems using three (or more) points. A transformation matrix based on a world coordinate system described the location and orientation of a local target coordinate system. Future research involving volume rendering of MRI data focusing on the internal kinematics of the hand's individual ligaments, cartilage, tendons, etc. will follow. Its findings will show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove (power assisted) design for extravehicular activity (EVA).

Dickenson, Rueben D.↗