Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ATOMIC NUMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Resonance-to-intercombination-line ratios of neonlike ions in the relativistic regime

We report measurements of the intensity ratio of the 1s 2 2s 2 2p$5\atop{1/2}$3d 3/2 →1s 2 2s 2 2p 6 resonance line to the 1s 2 2s 2 2p$5\atop{3/2}$3d 5/2 →1s 2 2s 2 2p 6 intercombination line in neonlike Kr 26+ and Mo 32+ . The measurements were performed at the EBIT-I electron beam ion trap facility at the Lawrence Livermore National Laboratory and utilized an x-ray microcalorimeter. The measured ratio for Mo 32+ is in four times closer agreement with theoretical predictions than earlier measurements of ions with lower atomic number. Our measurement thus suggests a narrowing of the disagreement with atomic number, which had not been observed in the previously existing data. This implies that the disagreement with theory may be localized to ions within a range of atomic numbers in which intermediate coupling dominates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Solubility and partitioning of Ne, Ar, Kr, and Xe in minerals and synthetic basaltic melts

The solubilities of Ne, Ar, Kr, and Xe gases were measured in natural samples of anorthite, diopside, forsterite, spinel, and synthetic basaltic melts, the samples which represent equilibrium pairs in the Fo-An-Di-SiO2 system. Results show that, in natural minerals, the solubilities of these gases increase with increasing atomic number. In contrast, the solubilities of noble gases in the synthetic basaltic melts decreased with increasing atomic number. The partition coefficients increased with increasing atomic number for all mineral/melt pairs.

Broadhurst, C. L.↗

Rutherford backscattering oscillation in scanning helium-ion microscopy

Scanning helium-ion microscopy (SHIM) yields high-resolution imaging and is capable of surface elemental analysis at the nanometer scale. Here we examine recently discovered SHIM backscattered intensity oscillations versus the target atomic number. These oscillations are contrary to the expected monotonic increase of the backscattered helium-ion (He{sup +}) rate with the atomic number of elemental samples. We explore the ion-sample interaction via numerical simulations for a variety of scattering geometries and confirm the presence of oscillations. The oscillations are attributed to the atomic rather than the nuclear structure of the target. To that end, we study the link (near anticorrelation) between backscatter rate and He{sup +} beam stopping power, both versus the target atomic number. This leads us to ascribe the origin of the backscatter oscillation to the ''Z{sub 2}-oscillations'' of the stopping power in ion-beam physics, with the latter being rooted in the valence electron configuration of elemental targets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shock waves in a Z-pinch and the formation of high energy density plasma

A Z-pinch liner, imploding onto a target plasma, evolves in a step-wise manner, producing a stable, magneto-inertial, high-energy-density plasma compression. The typical configuration is a cylindrical, high-atomic-number liner imploding onto a low-atomic-number target. The parameters for a terawatt-class machine (e.g., Zebra at the University of Nevada, Reno, Nevada Terawatt Facility) have been simulated. The 2-1/2 D MHD code, MACH2, was used to study this configuration. The requirements are for an initial radius of a few mm for stable implosion; the material densities properly distributed, so that the target is effectively heated initially by shock heating and finally by adiabatic compression; and the liner's thickness adjusted to promote radial current transport and subsequent current amplification in the target. Since the shock velocity is smaller in the liner, than in the target, a stable-shock forms at the interface, allowing the central load to accelerate magnetically and inertially, producing a magneto-inertial implosion and high-energy density plasma. Comparing the implosion dynamics of a low-Z target with those of a high-Z target demonstrates the role of shock waves in terms of compression and heating. In the case of a high-Z target, the shock wave does not play a significant heating role. The shock waves carry current and transport the magnetic field, producing a high density on-axis, at relatively low temperature. Whereas, in the case of a low-Z target, the fast moving shock wave preheats the target during the initial implosion phase, and the later adiabatic compression further heats the target to very high energy density. As a result, the compression ratio required for heating the low-Z plasma to very high energy densities is greatly reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low keV electron probe analysis of silicate minerals for Mg, Al, and Si using pure-element standards

Accurate electron probe values for Mg, Al, and Si in silicate minerals may be obtained with pure-element standards. Analysis must be done at low (6 kV) accelerating potential and for best results, the average atomic number of the sample should be within about plus or minus 1 of the atomic number of the pure-element standard. This last requirement is automatically fulfilled for most common silicate minerals, as their average atomic numbers usually fall within the 11 to 15 range. Examples studied include a wet-chemically analyzed cordierite containing 17.71 weight percent Al, for which a value of 17.6 plus or minus 0.3 percent was obtained with the electron probe, and a hornblende containing 19.15 percent Si, which gave 19.0 plus or minus 0.3 percent using the probe method.

Cunningham, G. G.↗

Precise Compositional Characterization of Plutonium Alloys by Electron Probe Microanalysis

Key Takeaway Points: • Unlike most other materials, the precise compositional analysis of plutonium, including compounds and alloys, is riddled by numerous difficulties that are unique to the element, including the high atomic number and radioactive nature. There’s work to be done! • Radioactive materials require special handling to ensure precise compositions can be measured by EPMA. • Mean Atomic Number background corrections are limited due to high average atomic number. • Mass Absorption Coefficients are unknown for most light elements. Quantification relies upon calibration curves. • Principal Component Analysis could be a useful tool to improve interpretation of complicated, multiple element X-ray maps.

Maner, IV, James L.↗

Quantum optics with quantum gases: Controlled state reduction by designed light scattering

Cavity-enhanced light scattering from an ultracold gas in an optical lattice constitutes a quantum measurement with a controllable form of the measurement backaction. Time-resolved counting of scattered photons alters the state of the atoms without particle loss implementing a quantum nondemolition measurement. The conditional dynamics is given by the interplay between photodetection events (quantum jumps) and no-count processes. The class of emerging atomic many-body states can be chosen via the optical geometry and light frequencies. Light detection along the angle of a diffraction maximum (Bragg angle) creates an atom-number-squeezed state, while light detection at diffraction minima leads to the macroscopic superposition states (Schroedinger cat states) of different atom numbers in the cavity mode. A measurement of the cavity transmission intensity can lead to atom-number-squeezed or macroscopic superposition states depending on its outcome. We analyze the robustness of the superposition with respect to missed counts and find that a transmission measurement yields more robust and controllable superposition states than the ones obtained by scattering at a diffraction minimum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Feasibility test of Z{sub eff} imaging using x-ray interferometry

Elemental imaging using X-ray interferometry has been developed. Since the atomic number (Z) of a single-element sample (effective atomic number (Z{sub eff}) for a plural-element sample) corresponds to the ratio of the real to imaginary part of the complex refractive index, an elemental map is calculable with the ratio of an absorption and phase-contrast image. Several metal foils underwent feasibility observations by crystal X-ray interferometry, providing accurate detection of X-ray intensity and phase-shift. The obtained Z{sub eff} image shows that aluminum, iron, nickel, and copper foil were clearly distinguished, and nickel and copper's Z{sub eff} values coincide with ideal Z number within 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular structure determination from x-ray scattering patterns of laser-aligned symmetric-top molecules.

We investigate the molecular structure information contained in the x-ray diffraction patterns of an ensemble of rigid CF{sub 3}Br molecules aligned by an intense laser pulse at finite rotational temperature. The diffraction patterns are calculated at an x-ray photon energy of 20 keV to probe molecular structure at angstrom-scale resolution. We find that a structural reconstruction algorithm based on iterative phase retrieval fails to extract a reliable structure. However, the high atomic number of Br compared with C or F allows each diffraction pattern to be treated as a hologram. Using this approach, the azimuthal projection of the molecular electron density about the alignment axis may be retrieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum Attachment for XRF Scanner

Vacuum apparatuses have been developed for increasing the range of elements that can be identified by use of x-ray fluorescent (XRF) scanners of the type mentioned in the two immediately preceding articles. As a consequence of the underlying physical principles, in the presence of air, such an XRF scanner is limited to analysis of chlorine and elements of greater atomic number. When the XRF scanner is operated in a vacuum, it extends the range of analysis to lower atomic numbers - even as far as aluminum and sodium. Hence, more elements will be available for use in XRF labeling of objects as discussed in the two preceding articles. The added benefits of the extended capabilities also have other uses for NASA. Detection of elements of low atomic number is of high interest to the aerospace community. High-strength aluminum alloys will be easily analyzed for composition. Silicon, a major contaminant in certain processes, will be detectable before the process is begun, possibly eliminating weld or adhesion problems. Exotic alloys will be evaluated for composition prior to being placed in service where lives depend on them. And in the less glamorous applications, such as bolts and fasteners, substandard products and counterfeit items will be evaluated at the receiving function and never allowed to enter the operation

Schramm, Harry F.↗

Larger sized wire arrays on 1.5 MA Z-pinch generator

Experiments on the UNR Zebra generator with Load Current Multiplier (LCM) allow for implosions of larger sized wire array loads than at standard current of 1 MA. Advantages of larger sized planar wire array implosions include enhanced energy coupling to plasmas, better diagnostic access to observable plasma regions, and more complex geometries of the wire loads. The experiments with larger sized wire arrays were performed on 1.5 MA Zebra with LCM (the anode-cathode gap was 1 cm, which is half the gap used in the standard mode). In particular, larger sized multi-planar wire arrays had two outer wire planes from mid-atomic-number wires to create a global magnetic field (gmf) and plasma flow between them. A modified central plane with a few Al wires at the edges was put in the middle between outer planes to influence gmf and to create Al plasma flow in the perpendicular direction (to the outer arrays plasma flow). Such modified plane has different number of empty slots: it was increased from 6 up to 10, hence increasing the gap inside the middle plane from 4.9 to 7.7 mm, respectively. Such load configuration allows for more independent study of the flows of L-shell mid-atomic-number plasma (between the outer planes) and K-shell Al plasma (which first fills the gap between the edge wires along the middle plane) and their radiation in space and time. We demonstrate that such configuration produces higher linear radiation yield and electron temperatures as well as advantages of better diagnostics access to observable plasma regions and how the load geometry (size of the gap in the middle plane) influences K-shell Al radiation. In particular, K-shell Al radiation was delayed compared to L-shell mid-atomic-number radiation when the gap in the middle plane was large enough (when the number of empty slots was increased up to ten)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximal Cherenkov γ-radiation on Fermi-surface of compact stars

The quantum magnetohydrodynamic model is employed in this paper to study the extraordinary (XO) elliptically polarized electromagnetic wave dispersion in quantum plasmas with spin-1/2 magnetization and relativistic degeneracy effects, considering also the electron-exchange and quantum diffraction of electrons. From the lower and upper calculated XO-modes, it is observed that, for electrons on the surface of the Fermi-sphere, the lower XO-mode can excite the Cherenkov radiation by crossing the Fermi-line, with some proper conditions depending on the values of independent plasma parameters, such as the relativistic-degeneracy, the atomic-number of constituent ions, and the magnetic field strength. Particularly, a lower electron number-density and Cherenkov radiation frequency limits are found to exist, for instance, for given values of the plasma ions atomic-number and the magnetic field strength below which the radiation can not be excited by the electrons on the Fermi-surface. This lower density limit increases by decrease in the atomic-number but decreases with decrease in the strength of the ambient magnetic field. It is remarkable that in this research it is discovered that the maximal Cherenkov-radiation per unit-length (the energy radiated by superluminal electrons traveling through the dielectric medium) coincides with the plasma number-densities, which is present in compact stars with the maximal radiation frequency lying in the gamma-ray spectrum. Current study can provide an important plasma diagnostic tool for a wide plasma density range, be it the solid density, the warm dense matter, the inertial confined or the astrophysical compact plasmas and may reveal an important cooling mechanism for white dwarfs. Current findings may also answer the fundamental astrophysical question on the mysterious origin of intense cosmic gamma-ray emissions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Why diamond dimensions and electrode geometry are crucial for small photon beam dosimetry

Recent use of very small photon beams (down to 4 mm) in stereotactic radiotherapy requires new detectors to accurately determine the delivered dose. Diamond detectors have been presented in the literature as an attractive candidate for this application, due to their small detection volume and the diamond atomic number (Z = 6) which is close to water effective atomic number (Zeff ∼ 7.42). However, diamond exhibits a density 3.51 times greater than that of water and recent studies using Monte Carlo simulations have demonstrated the drawback of a high-density detector on small beam output factors. The current study focuses on geometrical parameters of diamond detector, namely, the diamond dimensions and the electrode geometry, in order to solve the dosimetric issues still observed in small photon beams with diamond detectors. To give better insights to these open questions, we have used both computational method and experimental analysis. This study highlighted that reducing diamond dimensions is crucial for small beam output factor measurements and to limit the influence of its high density. Furthermore, electrodes covering the whole diamond surface were essential for a dose rate independence of the diamond detector. The optimal dosimeter derived from this work presented small diamond dimensions of approximately 1 × 1 × 0.15 mm{sup 3}, with diamond-like-carbon electrodes covering the whole diamond surface. A dose rate independence of this diamond detector (better than 0.5% over a wide range of dose rates available on a stereotactic dedicated facility) was obtained due to the electrode geometry. Concerning the output factor measurements, a good agreement (better than 1.1%) was observed between this carbon material detector and two types of passive dosimeters (LiF microcubes and EBT2 radiochromic films) for all beam sizes except the smallest field of 0.6 × 0.6 cm{sup 2} with a deviation of 2.6%. This new study showed the high performance of this diamond detector in small photon beams, in comparison with various commercially available passive and active dosimeters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dielectronic recombination in He-like, Li-like, and Be-like highly charged ions in the KLL and KLM manifolds

This paper reports a systematic study of the dependence on atomic number of the dielectronic recombination resonance strengths for He-like, Li-like and Be-like ions. Recent measurements of dielectronic recombination resonance strengths for the KLL and KLM manifolds for iron, yttrium, iodine, holmium, and bismuth are also described. The resonance strengths were normalized to calculated electron impact ionization cross sections. The measured resonance strengths generally agree well with theoretical calculations using the distorted wave approximation. However, KLM resonance strength measurements on high atomic number open-shell ions gave higher values than those suggested by calculations. Using recently measured data, along with existing results, scaling laws have been generated as a function of atomic number for He-like, Li-like, and Be-like ions in the KLL and KLM manifolds.

74 ATOMIC AND MOLECULAR PHYSICS↗

MO-FG-BRA-06: Material Optimisation for Nanoparticle-Sensitized Radiotherapy

Purpose: To evaluate the potential applications of nanoparticles of different elemental compositions as X-ray radiosensitizers. Methods: Geant4 Monte Carlo models were used to model the interactions of 10 nm radius nanoparticles of elements ranging from silicon to mercury with either monoenergetic keV X-rays or a 6 MV Linac spectrum. Secondary electron spectra emitted from nanoparticles and resulting radial doses were calculated. Potential biological impacts were evaluated through the use of the Local Effect Model. Results: For keV radiation, fluoresence photons and energetic photoelectrons deposit the majority of energy emitted by nanoparticles, over long ranges. However, short-range energy deposition is dominated by Auger electrons. While total energy deposition increases with atomic number, short-range energy deposition has a more complex behaviour, with local maxima around germanium (Z=32) and gadolinium (Z=64). For megavoltage radiation, Compton electrons deposit the majority of energy, but short- range depositions are dominated by interactions with secondary electrons. As a Result, energy deposition following ionising events following Linac irradiation is largely independent of atomic number.When analysed through the Local Effect Model, these effects translate into significant variations in predicted cell killing with atomic number for keV exposures, but comparatively limited effects for megavoltage exposures. Conclusions: Although heavier elements typically lead to greater increases in dose within target volumes, on the nanometre scale effects are typically dominated by low-energy secondary electrons, whose distribution has a complex relationship with both nanoparticle composition and beam energy.These results suggest that maximum radiosensitization may not necessarily be achieved through maximizing atomic number, but rather a balance between overall interaction cross-section and local dose distribution. The different behaviours seen when comparing keV and MV behaviours may also provide future mechanisms for separating physical and biological mechanisms of nanoparticle sensitisation, a key step in their development as a potential therapeutic agent.

60 APPLIED LIFE SCIENCES↗

A semiempirical transparency model for dual energy cargo radiography applications

Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in which only free streaming photons are detected. However, this approximation neglects second order effects such as scattering, leading to a biased model and thus incorrect material predictions. This work studies the accuracy of the free streaming model by comparing it to simulation outputs, finding that the model shows poor atomic number reconstruction accuracy at high- Z and suffers significantly if the source energy spectra and detector response function are not known exactly. To address these challenges, this work introduces a semiempirical transparency model which modifies the free streaming model by rescaling different components of the mass attenuation coefficient, allowing the model to capture secondary effects ignored by the free streaming model. The semiempirical model displays improvement agreement with simulated results at high- Z and shows excellent extrapolation to materials and thicknesses which were not included during the calibration step. Furthermore, this work demonstrates that the semiempirical model yields accurate atomic number predictions even when the source spectra and detector response are not known exactly. In conclusion, using the semiempirical model, manufacturers can perform a simple calibration to enable more precise Z reconstruction capabilities, which has the potential to significantly improve the performance of existing dual energy radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials Selection for Heavy Ion Fusion Hohlraums

The hohlraum surrounds the fuel capsule in a heavy ion fusion (HIF) target. The hohlraum absorbs ion beam driver energy and emits this energy uniformly around the capsule in the form of X-rays. High-atomic-number materials are necessary in the walls of the hohlraum to contain the X-ray energy around the capsule during the implosion process. These high-atomic-number hohlraum materials affect many aspects of an HIF power plant operation. A systematic review of available information for all high-atomic-number elements was conducted to select candidate hohlraum materials. The effects of materials on target fabrication, energy cost, target gain, radioactivity, chemical toxicity, and potential for recycle were considered. Lead and tungsten are the lowest-cost acceptable materials in the primary coolant. The combination of lead and tungsten provide better target gain than either material alone. Seeding the primary coolant with submicron-sized tungsten particles can minimize tungsten growth in small openings in power plant components such as vacuum tritium disengagers. In conclusion, concerns remain for possible tungsten particle agglomeration, settling, or erosion caused by tungsten particles. Tungsten could be replaced by several lanthanide elements if tungsten proves unacceptable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗