Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Optical Microsystems for Molecular Sensing (CRADA Final Report)

As part of the Cyclotron Road program, NuSight Photonics sought to implement and investigate an optical Raman spectroscopy instrument for material and molecular analysis. Raman spectroscopy is widely used for quick and non-invasive material measurement when accurate results are needed – e.g., for monitoring manufacturing process in pharmaceutical plants, or identifying illicit substances and explosives by Law Enforcement. This technique is also growing rapidly in popularity as it is applied successfully to a broad range of applications, from pathology and non-invasive early cancer detection, to food and drug safety. The biggest challenge for Raman spectroscopy to achieve its full potential is the hardware cost, ranging from $\$ $25k to $\$ $250k, with the lower cost solutions significantly limited in sensitivity—or detection limit. NuSight Photonics aimed to tackle this obstacle through a novel hardware approach: Swept-Source Raman Spectroscopy.

36 MATERIALS SCIENCE↗

A Spectroscopic Study of Mars-analog Materials with Amorphous Sulfate and Chloride Phases: Implications for Detecting Amorphous Materials on the Martian Surface

The Chemistry and Mineralogy X-ray diffraction (XRD) instrument aboard the Curiosity rover consistently identifies amorphous material at Gale Crater, which is compositionally variable, but often includes elevated sulfur and iron, suggesting that amorphous ferric sulfate (AFS) may be present. Understanding how desiccating ferric sulfate brines affect the spectra of Martian material analogs is necessary for interpreting complex/realistic reaction assemblages. Visible and near-infrared reflectance (VNIR), mid-infrared attenuated total reflectance (MIR, FTIR-ATR), and Raman spectra, along with XRD data are presented for basaltic glass, hematite, gypsum, nontronite, and magnesite, each at three grain sizes (<25, 25–63, and 63–180 μm), mixed with ferric sulfate (+/–NaCl), deliquesced, then rapidly desiccated in 11% relative humidity or via vacuum. All desiccated products are partially or completely XRD amorphous; crystalline phases include starting materials and trace precipitates, leaving the bulk of the ferric sulfate in the amorphous fraction. Due to considerable spectral masking, AFS detectability is highly dependent on spectroscopic technique and minerals present. This has strong implications for remote and in situ observations of Martian samples that include an amorphous component. AFS is only identifiable in VNIR spectra for magnesite, nontronite, and gypsum samples; hematite and basaltic glass samples appear similar to pure materials. Sulfate features dominate Raman spectra for nontronite and basaltic glass samples; the analog material dominates Raman spectra of hematite and gypsum samples. MIR data are least affected by masking, but basaltic glass is almost undetectable in MIR spectra of those mixtures. NaCl produces similar FTIR-ATR and Raman features, regardless of analog material.

58 GEOSCIENCES↗

Spectroscopy of the Hamburg Meteorite, Michigan H4

Spectroscopic studies of the Hamburg (Michigan H4) meteorite using visible–near-infrared (VNIR), mid-infrared (MIR), Raman, and Mössbauer data reproduce the results of more conventional laboratory measurements of petrology and geochemistry. This combination provides general information on the mineral modes of silicates, although spectroscopy was performed on different splits of this meteorite, and varying results may be explained by heterogeneity that is typical of ordinary chondrites. Raman also detects small features assigned to first-order D and G carbon bands, while Mössbauer data show the presence of Fe oxides and carbides. The electron microprobe (EMPA) composition of olivine in this meteorite is accurately measured to be Fo 81.3 , while MIR and Raman closely agree with Fo 80 and Fo 82 , respectively, and Mössbauer, at Fo 60 − Fo 70 , is in the ballpark. Similarly, P. R. Heck et al. report pyroxenes with compositions of Fs 16 Wo 1 , while Raman suggests a somewhat similar composition of Fs 28 Wo 0 . Both VNIR and MIR detect the presence of small amounts of feldspar, while EMPA identifies its composition as An 14 Ab 8 Or 5 . VNIR data were matched to spectral libraries of meteorite and asteroid data and shown to closely match other L and H meteorites. The best spectral matches to the Michigan H4 meteorite are to asteroid classes L/H/LL/URE, EH/EL/AUB, and CO/CV from M. D. Dyar et al.; objects in this group are intermediate in semimajor axis lengths for their orbits. The results highlight the strengths and weaknesses of each technique and show their collective strength when applied together to a single meteorite sample.

58 GEOSCIENCES↗

Relative cross section and depolarization of NOCl

A standard photon counting technique and an argon-ion laser with 4545, 4579, 4727, 4765, 4880, 4965, 5017 and 5145-A lasing lines, providing a measurable Raman spectrum from NOCl, were used in the measurement of the Raman scattering cross section of NOCl at a Raman shift of 334.4 plus or minus 1.6/cm in relation to the N2 Raman cross section. A polarization analyzer and a quartz wedge were placed in front of the entrance slit of the double monochromator for depolarization measurements. Diagrams are plotted to show the scattering cross section and depolarization measurement results.

Hoell, J. M.↗

Solidification kinetics

The vapor systems GeI2 and I2 and solid GeI4 were analyzed, using Raman spectroscopic techniques. The Raman bands of I2 and GeI4 were confirmed and Raman bands for GeI2 at 230 and 360 cm to the -1 power were reported. The application of the Raman techniques as a temperature probe in vapor transport kinetics was studied, and its feasibility is considered to be very good.

Mcnutt, R. C.↗

Ultra high resolution molecular beam cars spectroscopy with application to planetary atmospheric molecules

The measurement of high resolution pulsed and continuous wave (CW) coherent anti-Stokes Raman spectroscopy (CARS) measurements in pulsed and steady state supersonic expansions were demonstrated. Pulsed molecular beam sources were characterized, and saturation of a Raman transition and, for the first time, the Raman spectrum of a complex molecular cluster were observed. The observation of CW CARS spectra in a molecular expansion and the effects of transit time broadening is described. Supersonic expansion is established as a viable technique for high resolution Raman spectroscopy of cold molecules with resolutions of 100 MH2.

Byer, R. L.↗

Investigation of the feasibility of temperature profiling optical diagnostics in the SSME fuel pre-burner

Results of an analytical investigation to determine the feasibility of temperature profiling in the space shuttle main engine (SSME) fuel preburner are presented. In this application it is desirable to measure temperature in the preburner combustor with a remote, nonintrusive optical technique. Several techniques using laser excitation were examined with a consideration of the constraints imposed by optical access in the fuel preburner and the problems associated with operation near the functioning space shuttle engine. The potential performance of practical diagnostic systems based on spontaneous Raman backscattering, laser induced fluorescence, and coherent anti-Stokes Raman spectroscopy were compared analytically. A system using collection of spontaneous Raman backscattering excited by a remotely located 5 to 10 watt laser propagated to the SSME through a small diameter optical fiber was selected as the best approach. Difficulties normally associated with Raman scattering: weak signal strength and interference due to background radiation are not expected to be problematic due to the very high density in this application, and the low flame luminosity expected in the fuel rich hydrogen oxygen flame.

Shirley, J. A.↗

Development of eye-safe lidar for aerosol measurements

Research is summarized on the development of an eye safe Raman conversion system to carry out lidar measurements of aerosol and clouds from an airborne platform. Radiation is produced at the first Stokes wavelength of 1.54 micron in the eye safe infrared, when methane is used as the Raman-active medium, the pump source being a Nd:YAG laser at 1.064 micron. Results are presented for an experimental study of the dependence of the 1.54 micron first Stokes radiation on the focusing geometry, methane gas pressure, and pump energy. The specific new technique developed for optimizing the first Stokes generation involves retroreflecting the backward-generated first Stokes light back into the Raman cell as a seed Stokes beam which is then amplified in the temporal tail of the pump beam. Almost 20 percent conversion to 1.54 micron is obtained. Complete, assembled hardware for the Raman conversion system was delivered to the Goddard Space Flight Center for a successful GLOBE flight (1989) to measure aerosol backscatter around the Pacific basin.

Singh, Upendra N.↗

Simplifications of the RELIEF flow tagging system for laboratory use

The use of an O2:He stimulated Raman cell to generate the Stokes beam for the Raman vibrational pumping step of the RELIEF (Raman Excitation plus Laser-Induced Electronic Fluorescence) flow tagging method is reported. Use of the Raman cell rather than a dye laser provides pump and Stokes beams which are automatically frequency matched and temporally and spatially overlapped. The Nd:YAG pump laser is operated multilongitudinal mode, which eliminates the need for injection seeding, resulting in decreased operation complexity and improved stability with respect to acoustic noise. Results are presented for 1st Stokes conversion efficiency and stimulated Brillouin backscattering loss and are compared to the case of pure O2. Scanning CARS measurements of the Q-branch lineshape for both pure O2 and the O2:He mixture are also presented.

Lempert, Walter R.↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

Laser diagnostics for small rockets

Two nonintrusive flowfield diagnostics based on spectrally-resolved elastic (Rayleigh) and inelastic (Raman) laser light scattering were developed for obtaining local flowfield measurements in low-thrust gaseous H2/O2 rocket engines. The objective is to provide an improved understanding of phenomena occurring in small chemical rockets in order to facilitate the development and validation of advanced computational fluid dynamics (CFD) models for analyzing engine performance. The laser Raman scattering diagnostic was developed to measure major polyatomic species number densities and rotational temperatures in the high-density flowfield region extending from the injector through the chamber throat. Initial application of the Raman scattering diagnostic provided O2 number density and rotational temperature measurements in the exit plane of a low area-ratio nozzle and in the combustion chamber of a two-dimensional, optically-accessible rocket engine. In the low-density nozzle exit plane region where the Raman signal is too weak, a Doppler-resolved laser Rayleigh scattering diagnostic was developed to obtain axial and radial mean gas velocities, and in certain cases, H2O translational temperature and number density. The results from these measurements were compared with theoretical predictions from the RPLUS CFD code for analyzing rocket engine performance. Initial conclusions indicate that a detailed and rigorous modeling of the injector is required in order to make direct comparisons between laser diagnostic measurements and CFD predictions at the local level.

Zupanc, Frank J.↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗

Chirality Characterization of Dispersed Single Wall Carbon Nanotubes

Raman scattering and optical absorption spectroscopy are used for the chirality characterization of HiPco single wall carbon nanotubes (SWNTs) dispersed in aqueous solution with the surfactant sodium dodecylbenzene sulfonate. Radial breathing mode (RBM) Raman peaks for semiconducting and metallic SWNTs are identified by directly comparing the Raman spectra with the Kataura plot. The SWNT diameters are calculated from these resonant peak positions. Next, a list of (n, m) pairs, yielding the SWNT diameters within a few percent of that obtained from each resonant peak position, is established. The interband transition energies for the list of SWNT (n, m) pairs are calculated based on the tight binding energy expression for each list of the (n, m) pairs, and the pairs yielding the closest values to the corresponding experimental optical absorption peaks are selected. The results reveal that (1, 11), (4, 11), and (0, 11) as the most probable chiralities of the semiconducting nanotubes. The results also reveal that (4, 16), (6, 12) and (8, 8) are the most probable chiralities for the metallic nanotubes. Directly relating the Raman scattering data to the optical absorption spectra, the present method is considered the simplest technique currently available. Another advantage of this technique is the use of the E(sup 8)(sub 11) peaks in the optical absorption spectrum in the analysis to enhance the accuracy in the results.

Namkung, Min↗

Nanostructure Diffraction Gratings for Integrated Spectroscopy and Sensing

The present disclosure pertains to metal or dielectric nanostructures of the subwavelength scale within the grating lines of optical diffraction gratings. The nanostructures have surface plasmon resonances or non-plasmon optical resonances. A linear photodetector array is used to capture the resonance spectra from one of the diffraction orders. The combined nanostructure super-grating and photodetector array eliminates the use of external optical spectrometers for measuring surface plasmon or optical resonance frequency shift caused by the presence of chemical and biological agents. The nanostructure super-gratings can be used for building integrated surface enhanced Raman scattering (SERS) spectrometers. The nanostructures within the diffraction grating lines enhance Raman scattering signal light while the diffraction grating pattern of the nanostructures diffracts Raman scattering light to different directions of propagation according to their wavelengths. Therefore, the nanostructure super-gratings allows for the use of a photodetector array to capture the surface enhanced Raman scattering spectra.

Guo, Junpeng↗

Nanostructure Diffraction Gratings for Integrated Spectroscopy and Sensing

The present disclosure pertains to metal or dielectric nanostructures of the subwavelength scale within the grating lines of optical diffraction gratings. The nanostructures have surface plasmon resonances or non-plasmon optical resonances. A linear photodetector array is used to capture the resonance spectra from one of the diffraction orders. The combined nanostructure super-grating and photodetector array eliminates the use of external optical spectrometers for measuring surface plasmon or optical resonance frequency shift caused by the presence of chemical and biological agents. The nanostructure super-gratings can be used for building integrated surface enhanced Raman scattering (SERS) spectrometers. The nanostructures within the diffraction grating lines enhance Raman scattering signal light while the diffraction grating pattern of the nanostructures diffracts Raman scattering light to different directions of propagation according to their wavelengths. Therefore, the nanostructure super-gratings allows for the use of a photodetector array to capture the surface enhanced Raman scattering spectra.

Guo, Junpeng↗

SHERLOC Investigations at the Máaz and Séítah formations within Jezero crater

Introduction: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument combines microscopic imaging, native fluorescence and Raman spectroscopy to better understand the mineral and chemical makeup of rocks on the martian surface. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. These signatures are obtained on a 100 micron spatial scale and collocated to images so textures, minerals and chemicals can all be compared [1]. Results: SHERLOC has been operating on Mars since February 18, 2021. As of this writing, we have analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater [2]. The Guillaumes target (from the Roubion outcrop, Roubion member of the Máaz Formation) is dominated by Ca-sulfate with patches of perchlorate. The Bellegarde target (from the Rochette outcrop, Rochette member of the Máaz Formation) exhibits Raman peaks that match hydrated Ca-sulfate, amorphous/microcrystalline silicate (AMS), carbonate, and phosphate phases. A fluorescence doublet at ~305 and ~325 nm was detected and is most likely due to indigenous organic material in the sample. The Garde target (from the Bastide outcrop, Bastide member of the Séítah Formation) is dominated by olivine and carbonate with AMS occurring across the material. The Dourbes target (from the Brac outcrop, Bastide member of the Séítah Formation) is dominated by olivine and shows minor amounts of carbonate, hydrated Ca-sulfate, and AMS. The Quartier target exhibits a large sulfate feature, as well as carbonate, perchlorate, olivine and a fluorescence doublet at 305 and 325 nm and is very similar to that observed at Bellegarde. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. Acknowledgments: This work was carried out at the Jet Propulsion Laboratory, The California Institute of Technology under a contract from NASA.

L W Beegle↗

Mapping Organic-Mineral Associations in Jezero crater

The search for potential signs of life on Mars, a primary aim of the Mars 2020 mission, is greatly informed by the detection of organic matter1. The presence of organic matter also provides key information about the habitability and biological potential of the planet throughout its history. The Perseverance rover was designed for in situ science with the ability to collect a suite of promising samples for eventual return to Earth. One of its instruments, Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC), is a deep ultraviolet (DUV) Raman and fluorescence spectrometer designed to map the distribution of organic molecules and minerals on rock surfaces at a resolution of 100 μm2. With its unique spectral mapping capabilities, SHERLOC enables a novel understanding of organic-mineral relationships on Mars to better determine their formation, deposition, and preservation mechanisms. The rover’s landing site within Jezero crater combines a high potential for past habitability as the site of an ancient lake basin with a diverse set of minerals, including carbonates and clays, that may preserve organic materials and potential biosignatures. The Jezero crater floor includes three formations (fm); two of these, Máaz and Séítah, were explored as part of the mission’s first campaign. Here, we report the detection of multiple species of aromatic organic molecules using Raman and fluorescence spectroscopy across ten targets in the two formations. This is the first evidence of organic molecules in Martian materials obtained using Raman spectroscopy, and among the first using fluorescence spectroscopy, beyond Earth3. We report specific spatial patterns and classes of organic molecules in these compositionally distinct formations, potentially indicating different fates of carbon in these environments. Our findings indicate that there is a diversity of aromatic molecules prevalent on the Martian surface and these materials persist despite exposure to surface conditions. These organic molecules are largely found within minerals linked to aqueous processes, suggesting that these processes may have had a key role in organic synthesis, transport from their point of origin, or preservation.

Sunanda Sharma↗