Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Undulation and anomaly estimation using Geos-3 altimeter data without precise satellite orbits

Geos-3 altimeter data was used to obtain an approximate geoid undulation which was contaminated by long wavelength errors caused primarily by altimeter bias and orbit error. This error was reduced by fitting, with a low degree polynomial, the raw undulation data to the undulations implied by the GEM 7 potential coefficients in an adjustment process that included conditions on tracks that cross. These adjusted undulations were used to construct a geoid map in the Geos-3 calibration area using a least squares filter to remove the remaining noise in the undulations.

Rummel, R.↗

Precision calculation of the lowest 1S resonance in e-H scattering

The position and width of the lowest resonance in electron-hydrogen scattering have been calculated using a Hylleraas correlation function with up to 95 terms in the optical potential formalism. The results should be useful as calibration points for experimental electron scattering purposes. A formula relating the conventional (Breit-Wigner) width with the Feschbach formalism is derived.

Ho, Y. K.↗

Performance tests of two precision attitude determination systems

Results of laboratory performance tests of two satellite attitude determination systems are given. One system employed a strapdown star tracker and gyro assembly, the other a single axis, gimballed star tracker and a gyro assembly. The laboratory tests simulated those orbit conditions which would be experienced on a three axis stabilized, earth pointed satellite in geosynchronous orbit. A ground-fixed laboratory test was performed in which system axes remained stationary in the laboratory coordinates while revolving star beams stimulated the star trackers. The laboratory instrumentation techniques used to meet the stringent accuracy requirements are described. Results are presented which show both systems met the performance goal of 3.6 arc seconds. Comparative analyses of both systems are also discussed.

Mcaloon, K. J.↗

Precision measurements of NH3 spectral lines near 11 microns using the infrared heterodyne technique

Absolute line-center frequencies for eleven lines of ammonia in near coincidence with CO2-laser transitions have been determined to accuracies of + or -3 MHz by infrared heterodyne detection. These results were obtained by heterodyning a blackbody with a stable grating-tuned CO2 gas laser. A discussion of the apparatus and method of calculation, including error analysis, is presented. With these accurately determined line-center positions, the ammonia molecule will be a useful secondary-frequency standard for diode-laser spectroscopy in the 11-micron wavelength region.

Hillman, J. J.↗

Precision fluid-pressure regulator

Reshaping of metering orifice improves pressure control and stability. Slotted hollow pintle replaces poppet to increase linear motion required to obtain given pressure drop.

Mcdougal, A. R.↗

Precision cleaver for "soft" crystals

"Soft" crystals are cleaved as thin 0.005 inch with special cleaver. Thin slices of soft crystalline materials are used in X-ray spectrometers. Slices are usually cut by hand with wire or blade. Wire tends to scratch surface and to produce slices of nonuniform thickness. Device will rapidly cut soft crystals in smooth, thin, uniform slices.

Benedicto, J. S. J.↗

Precise matching of diodes

Two circuit arrangements using ac and dc power source provide low-cost method for matching forward voltage drops of diodes and other semiconductors. Both circuits are simpler and less expensive than conventional, characteristic-curve tracers.

Mclyman, W. T.↗

High sensitivity 1.06 micron optical receiver for precision laser range finding

Aluminum gallium antimonide avalanche photodiodes with average gain of 10, internal quantum efficiency of greater than 60%, capacitance less than 0.2pf, and dark current of less than 1 micron were designed and fabricated for use in a low noise optical receiver suitable for 2 cm accuracy rangefinding. Topics covered include: (1) design of suitable photodetector structures; (2) epitaxial growth of AlGaSb devices; (3) fabrication of photodetectors; and (4) electro-optics characterization.

Scholl, F. W.↗

Synthesis and analysis of precise spaceborne laser ranging systems, volume 1

Measurement accuracy goals of 2 cm rms range estimation error and 0.003 cm/sec rms range rate estimation error, with no more than 1 cm (range) static bias error are requirements for laser measurement systems to be used in planned space-based earth physics investigations. Constraints and parameters were defined for links between a high altitude, transmit/receive satellite (HATRS), and one of three targets: a low altitude target satellite, passive (LATS), and active low altitude target, and a ground-based target, as well as with operations with a primary transmit/receive terminal intended to be carried as a shuttle payload, in conjunction with the Spacelab program.

Paddon, E. A.↗

Precision Positional Data of General Aviation Air Traffic in Terminal Air Space

Three dimensional radar tracks of general aviation air traffic at three uncontrolled airports are considered. Contained are data which describe the position-time histories, other derived parameters, and reference data for the approximately 1200 tracks. All information was correlated such that the date, time, flight number, and runway number match the pattern type, aircraft type, wind, visibility, and cloud conditions.

Melson, W. E., Jr.↗

High-precision laser distance measurement in support of lunar laser ranging at Haleakala, Maui, 1976-1977

The Hawaii Institute of Geophysics has implemented a comprehensive geodetic-geophysical support program to monitor local and regional crustal deformation on the island of Maui. Presented are the actual laser-measured line lengths and new coordinate computations of the line terminals, and the internal consistency of the measured line lengths is discussed. Several spacial chord lengths have been reduced to a Mercator plane, and conditioned adjustments on that plane have been made.

Berg, E.↗

Electronic measurement of variable torques in precision work technology

Approaches for the determination of torques on the basis of length measurements are discussed. Attention is given to torque determinations in which the deformation of a shaft is measured, an electric measurement of the torsion angle, and an approach proposed by Buschmann (1970). Methods for a torque determination conducted with the aid of force measurements make use of piezoelectric approaches. The components used by these methods include a quartz crystal and a charge amplifier.

Maehr, M.↗

Calibration standards and field instruments for the precision measurement of insolation

The design of a fieldworthy survey instrument based on a developed radiation calibration standard is discussed. The radiometer system, a fieldworthy modification of Pacrad, is an all-weather solar radiometer, and a field test is described which demonstrates the instrument's stability in severe environments over an extended period of time. It is suggested that the instrument may be considered a transfer standard as well as a radiometer. It is hoped that future modifications might reduce the 15-deg view angle and improve the tracking system to eliminate weekly manual declination adjustments.

Reid, M. S.↗

Precision gravity detection - Gradiometry and/or radiometry

Current knowledge concerning the earth's gravity field is limited to about 1500-2000 km resolution. However, the resolution of gravity anomalies having a spatial extent of 100-1000 km over the entire globe is needed for important geophysical and geodetic applications. In the near future satellite altimetry will be used to determine the ocean geoid at the 10 cm - 1 m level. In order to provide a similar level of resolutions over the land regions, there exists a need for utilizing new promising techniques such as gravity gradiometry and new radiometric measurements, viz., satellite-to-satellite tracking. Satellite-to-satellite tracking techniques have shown potential for improving the medium wavelength component of the gravity field. The gravity gradiometer has not yet been tested on board a satellite. The reported analysis includes a simplified theoretical model to compare the effectiveness of the gradiometer measurements and radiometric measurements for high resolution gravity field determination, and the direct estimation of local gravity anomalies represented by point masses using a simulated gravity gradiometer and satellite-to-satellite tracking data.

Ananda, M.↗

Precision leveling of large machinery

Tool originally developed to level massive circular runners on antennas for communicating with space vehicles is modified to accurately align and level other large machines thus proves faster and more accurate than surveying technique.

Phillips, H. P.↗

Precise wet-chemical etching

Controlled amount of etchant applied to surface of rotating sample removes only few angstroms of material. Technique is suited to study of chemical and crystal structures. Rate can be varied through control of spin frequency, liquid viscosity, droplet size, total etchant volume, etchant concentration.

Grunthaner, F. J.↗