Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Technology requirements to be addressed by the NASA Lewis Research Center Cryogenic Fluid Management Facility program

The NASA Lewis Research Center is responsible for the planning and execution of a scientific program which will provide advance in space cryogenic fluid management technology. A number of future space missions were identified that require or could benefit from this technology. These fluid management technology needs were prioritized and a shuttle attached reuseable test bed, the cryogenic fluid management facility (CFMF), is being designed to provide the experimental data necessary for the technology development effort.

Aydelott, J. C.↗

Estimating Transient Pressure Surges in Cryogenic Systems

Potentially-damaging pressure waves anticipated and, therefore, avoided. Mathematical model developed for prediction of pressure behavior in single-and two-phase cryogenic systems. Transient liquid-flow analysis modified to incorporate behavior of vapor bubbles and used to predict maximum pressure in cryogenic transfer systems consisting of complex pipe and valve arrangements under both steady-state and transient conditions. Simulation compared favorably with data obtained during transfer of liquid oxygen from ground storage tanks to Space Shuttle orbiter external tanks. Program written in FORTRAN 77 for batch execution.

Pfister, P.↗

Investigation of Low-temperature Solders for Cryogenic Wind Tunnel Models

The advent of high Reynolds number cryogenic wind tunnels has forced alteration of manufacturing and assembly techniques and eliminated usage of many materials associated with conventional wind tunnel models. One of the techniques affected is soldering. Solder alloys commonly used for wind tunnel models are susceptible to low-temperature embrittlement and phase transformation. The low-temperature performance of several solder alloys is being examined during research and development activities being conducted in support of design and fabrication of cryogenic wind tunnel models. Among the properties examined during these tests are shear strength, surface quality, joint stability, and durability when subjected to dynamic loading. Results of these tests and experiences with recent models are summarized.

Firth, G. C.↗

Computer program for calculating flow parameters and power requirements for cryogenic wind tunnels

A computer program has been written that performs the flow parameter calculations for cryogenic wind tunnels which use nitrogen as a test gas. The flow parameters calculated include static pressure, static temperature, compressibility factor, ratio of specific heats, dynamic viscosity, total and static density, velocity, dynamic pressure, mass-flow rate, and Reynolds number. Simplifying assumptions have been made so that the calculations of Reynolds number, as well as the other flow parameters can be made on relatively small desktop digital computers. The program, which also includes various power calculations, has been developed to the point where it has become a very useful tool for the users and possible future designers of fan-driven continuous-flow cryogenic wind tunnels.

Dress, D. A.↗

Problems associated with operations and measurement in cryogenic wind tunnels

Cryogenic wind tunnel T'3 under continuous blower operation has been the object of improvements and the installation of auxiliary equipment, dealing in particular with the enlargement of the liquid nitrogen injection reservoir and the hook-up to a fast data acquisition system. Following a brief description of the installation and its functioning, we present the main experimental techniques and the instrumentation used in the cryogenic environment.

Blanchard, A.↗

Temperature control of silica mirrors for cryogenically-cooled telescopes in space

The SIRTF (Space Infrared Telescope Facility) optical subsystem, including the primary mirror, has been modeled using lumped-parameter techniques and a thermal and cryogenic transient analysis program developed previously. Since silica mirrors have been shown to have significantly less distortion due to cryogenic cooldown, a silica primary mirror of approximately 1 m diameter is being considered. Thermal responses to variations in aperture heat load and heat sink temperature have been explored. Calculations have been made of system noise components from primary mirror spatial and temporal temperature variations. Background-limited infrared observations can be made at wavelengths out to 200 micrometers. Mirror thermal performance with and without copper wires for cooling is also considered.

Melugin, R. K.↗

Summary of test techniques used in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel

This paper describes test techniques used to obtain data in the 0.3-m Transonic Cryogenic Tunnel. Main sections include steady aerodynamic testing, unsteady aerodynamics, non-intrusive measurements, tunnel performance, and fluid mechanics. Test techniques with adequate previous documentation are briefly presented and referenced, and those for which no documentation yet exists are more thoroughly discussed. Attention is given to the model building and instrumentation technology necessary for testing at high Reynolds numbers in the presence of free transition. It is concluded that the testing techniques thus far demonstrated in the 0.3-m TCT are on par with modern transonic tunnels, and that the specialized techniques needed to exploit the advantages of cryogenic operation can be realized.

Lawing, P. L.↗

MOSFET's for Cryogenic Amplifiers

Study seeks ways to build transistors that function effectively at liquid-helium temperatures. Report discusses physics of metaloxide/semiconductor field-effect transistors (MOSFET's) and performances of these devices at cryogenic temperatures. MOSFET's useful in highly sensitive cryogenic preamplifiers for infrared astronomy.

Dehaye, R.↗

Aerodynamic measurements and thermal tests of a strain-gage balance in a cryogenic wind tunnel

An internal strain-gage balance designed and constructed in Europe for use in cryogenic wind tunnels has been tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel. Part of the evaluation was made at equilibrium balance temperatures and it consisted of comparing the data taken at a tunnel stagnation temperature of 300 K with the data taken at 200 K and 110 K while maintaining either the Reynolds number or the stagnation pressure. A sharp-leading-edge delta-wing model was used to provide the aerodynamic loading for these tests. Results obtained with the balance during the force tests were found to be accurate and repeatable both with and without the use of a convection shield on the balance. An additional part of this investigation involved obtaining data on the transient temperature response of the balance during both normal and rapid changes in the tunnel stagnation temperature. The variation of the temperature with time was measured at three locations on the balance near the physical locations of the strain gages. The use of a convection shield significantly increased the time required for the balance to stabilize at a new temperature during the temperature response tests.

Boyden, Richmond P.↗

Long term cryogenic storage facility systems study

The Long Term Cryogenic Storage Facility Systems Study (LTCSFSS) is a Phase A study of a large capacity propellant depot for the space based, cryogenic orbital transfer vehicle. The study is being performed for Marshall Space Flight Center by General Dynamics Space Systems Division and has five principal objectives: (1) Definition of preliminary concept designs for four storage facility concepts; (2) Selection of preferred concepts through the application of trade studies to candidate propellant management system components; (3) Preparation of a conceptual design for an orbital storage facility; (4) Development of supporting research and technology requirements; and (5) Development of a test program to demonstrate facility performance. The initial study has been completed, and continuation activities are just getting under way to provide greater detail in key areas and accommodate changes in study guidelines and assumptions.

Schuster, John R.↗

Numerical modelling of cryogenic propellant behavior in low-G

A partial survey is presented of recent research, sponsored by the NASA Lewis Research Center, into the computational modelling of cryogenic propellant behavior in a low gravity environment. This presentation is intended to provide insight into some of the specific problems being studied and into how these studies are part of an integrated plan to develop predictive capabilities. A brief description of the computational models developed to analyze jet induced mixing in cryogenic propellant tankage is presented along with representative results. Similar information is presented for a recent examination of on-orbit self-pressurization. A study of propellant reorientation has recently been initiated and preliminary results are included. The presentation concludes with a list of ongoing efforts and projected goals.

Hochstein, John I.↗

Thermodynamic analysis and subscale modeling of space-based orbit transfer vehicle cryogenic propellant resupply

The resupply of the cryogenic propellants is an enabling technology for spacebased orbit transfer vehicles. As part of the NASA Lewis ongoing efforts in microgravity fluid management, thermodynamic analysis and subscale modeling techniques were developed to support an on-orbit test bed for cryogenic fluid management technologies. Analytical results have shown that subscale experimental modeling of liquid resupply can be used to validate analytical models when the appropriate target temperature is selected to relate the model to its prototype system. Further analyses were used to develop a thermodynamic model of the tank chilldown process which is required prior to the no-vent fill operation. These efforts were incorporated into two FORTRAN programs which were used to present preliminary analyticl results.

Defelice, David M.↗

Adjustable mount for electro-optic transducers in an evacuated cryogenic system

The invention is an adjustable mount for positioning an electro-optic transducer in an evacuated cryogenic environment. Electro-optic transducers are used in this manner as high sensitivity detectors of gas emission lines of spectroscopic analysis. The mount is made up of an adjusting mechanism and a transducer mount. The adjusting mechanism provided five degrees of freedom, linear adjustments and angular adjustments. The mount allows the use of an internal lens to focus energy on the transducer element thereby improving the efficiency of the detection device. Further, the transducer mount, although attached to the adjusting mechanism, is isolated thermally such that a cryogenic environment can be maintained at the transducer while the adjusting mechanism remains at room temperature. Radiation shields also are incorporated to further reduce heat flow to the transducer location.

Crossley, Edward A., Jr.↗

Test of a trail cryogenic balance in the ONERA T2 wind tunnel

The three component cryogenic balance designed and manufactured by the ONERA Large Means Directorate, was equipped with a light alloy schematic model and tested at the end of 1984 at the T2 wind tunnel in gusts at low temperatures up to 120 K. The tests pertained to the impact of the cryogenic conditions on the behavior of extensometric bridges while cooling the balance-model system mounted in the conditioning device and during gusts with models in the test section. A few tests with thermal disequilibrium between the flow and balance made it possible to confirm the proper operation in the range 120 to 300 K. This gust system showed that the balance, which was well compensated thermally, may be used in T2 with and without precooling. For any thermal gradient, the analysis was always performed with the same matrices and aerodynamic coefficients were obtained with the same precision.

Blanchard, A.↗

Evolution, calibration, and operational characteristics of the two-dimensional test section of the Langley 0.3-meter transonic cryogenic tunnel

Presented is a review of the development of the world's first cryogenic pressure tunnel, the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). Descriptions of the instrumentation, data acquisition systems, and physical features of the two-dimensional 8- by 24-in, (20.32 by 60.96 cm) and advanced 13- by 13-in (33.02 by 33.02 cm) adaptive-wall test-section inserts of the 0.3-m TCT are included. Basic tunnel-empty Mach number distributions, stagnation temperature distributions, and power requirements are included. The Mach number capability of the facility is from about 0.20 to 0.90. Stagnation pressure can be varied from about 80 to 327 K.

Ladson, Charles L.↗

Evaluation of on-orbit cryogenic propellant depot options for the orbital transfer vehicle

An orbital cryogenic propellant storage facility will be required for a space-based Orbital Transfer Vehicle. The facility tanks will have features to permit fluid acquisition and transfer in low gravity and to limit cryogen boiloff caused by environmental heating. Boiloff management features will include thick multilayer insulation, vapor-cooled shields, low conductance structural supports and penetrations, and possibly refrigeration systems.

Schuster, J. R.↗

Thermodynamic analysis and subscale modeling of space-based orbit transfer vehicle cryogenic propellant resupply

The resupply of the cryogenic propellants is an enabling technology for spacebased orbit transfer vehicles. As part of the NASA Lewis ongoing efforts in microgravity fluid management, thermodynamic analysis and subscale modeling techniques were developed to support an on-orbit test bed for cryogenic fluid management technologies. Analytical results have shown that subscale experimental modeling of liquid resupply can be used to validate analytical models when the appropriate target temperature is selected to relate the model to its prototype system. Further analyses were used to develop a thermodynamic model of the tank chilldown process which is required prior to the no-vent fill operation. These efforts were incorporated into two FORTRAN programs which were used to present preliminary analytical results.

Defelice, David M.↗

Study of an all SFHE SIRTF cryogenic system

The Space Infrared Telescope Facility (SIRTF) is a superfluid helium cooled, 85-cm telescope with three infrared instruments at the focal plane. SIRTF will establish in space a long-term-maintainable infrared observatory for the region of 2-700 microns. The cryogenic system can be designed to last up to six years with 1280 kg of superfluid, and can function in either a 28.5 deg or 98 deg inclination orbit by exchanging the sunshade. The lifetime is primarily a function of instrument heat load rather than parasitic heat to the cryogen system.

Urbach, A. R.↗