Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Observation of x-ray radiation pressure effects on nanocrystals

Bragg coherent diffractive imaging is a powerful technique that can be used to explore the internal structure and strain of nanoscale crystalline objects. During the data collection process, the Bragg peak typically stays within a small range of pixels on the x-ray sensitive area detector. Here, we report abrupt and irreversible Bragg peak movement during the coherent x-ray data collection process for both Pd nanocubes and a Ni nanowire. Here, we report that this phenomenon can be attributed to x-ray momentum transfer, also known as radiation pressure, to the nanocrystals. Understanding this effect is crucial given the anticipated coherent flux increases at next-generation synchrotron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A data acquisition system for HV-CMOS sensor research and development in the upgrade of ATLAS experiment

In the High Luminosity LHC (HL-LHC) upgrade of ATLAS experiment in 2026, the new inner tracker detector will be installed. As a promising candidate for the outer layer of the inner tracker detector, the High Voltage CMOS (HV-CMOS) pixel sensors are being investigated by the ATLAS collaboration. A Front-End LInk eXchange (FELIX) based Data Acquisition (DAQ) system is developed for the R&D of the HV-CMOS sensors. A FELIX card with PCIe interface in the back-end is used to control, monitor, calibrate and read out the front-end electronics. In the front-end, a Xilinx evaluation board ZC706 works as the interface between the back- end and custom boards with HV-CMOS sensors and the readout ASIC. In conclusion, the DAQ system was successfully deployed for the testbeam experiment at CERN. Design of the DAQ system, the tuning of sensors and testbeam results will be described in details.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High performance FPGA embedded system for machine learning based tracking and trigger in sPhenix and EIC

We present a comprehensive end-to-end pipeline to classify triggers versus background events in this paper. This pipeline makes online decisions to select signal data and enables the intelligent trigger system for efficient data collection in the Data Acquisition System (DAQ) of the upcoming sPHENIX and future EIC (Electron-Ion Collider) experiments. Starting from the coordinates of pixel hits that are lightened by passing particles in the detector, the pipeline applies three-stage of event processing (hits clustering, track reconstruction, and trigger detection) and labels all processed events with the binary tag of trigger versus background events. The pipeline consists of deterministic algorithms such as clustering pixels to reduce event size, tracking reconstruction to predict candidate edges, and advanced graph neural network-based models for recognizing the entire jet pattern. In particular, we apply the message-passing graph neural network to predict links between hits and reconstruct tracks and a hierarchical pooling algorithm (DiffPool) to make the graph-level trigger detection. We obtain an impressive performance (≥70% accuracy) for trigger detection with only 3200 neuron weights in the end-to-end pipeline. We deploy the end-to-end pipeline into a field-programmable gate array (FPGA) and accelerate the three stages with speedup factors of 1152, 280, and 21, respectively.

Instruments & Instrumentation↗

Experimental 3D coherent diffractive imaging from photon-sparse random projections

The routine atomic resolution structure determination of single particles is expected to have profound implications for probing structure–function relationships in systems ranging from energy-storage materials to biological molecules. Extremely bright ultrashort-pulse X-ray sources – X-ray free-electron lasers (XFELs) – provide X-rays that can be used to probe ensembles of nearly identical nanoscale particles. When combined with coherent diffractive imaging, these objects can be imaged; however, as the resolution of the images approaches the atomic scale, the measured data are increasingly difficult to obtain and, during an X-ray pulse, the number of photons incident on the 2D detector is much smaller than the number of pixels. This latter concern, the signal `sparsity', materially impedes the application of the method. An experimental analog using a conventional X-ray source is demonstrated and yields signal levels comparable with those expected from single biomolecules illuminated by focused XFEL pulses. The analog experiment provides an invaluable cross check on the fidelity of the reconstructed data that is not available during XFEL experiments. Using these experimental data, it is established that a sparsity of order 1.3 × 10 −3 photons per pixel per frame can be overcome, lending vital insight to the solution of the atomic resolution XFEL single-particle imaging problem by experimentally demonstrating 3D coherent diffractive imaging from photon-sparse random projections.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma detectors based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material, and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. Since best MMC performance requires detector operation at ~10 mK, we will purchase a dilution refrigerator with a base temperature <10 mK and adapt it for MMC operation. The detector performance will be tested with radioactive sources of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Tagging From Neutrino Interactions in DUNE-ND 2x2 Prototype

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims to measure whether CP is violated in the leptonic sector (if violated, how much) and unambiguously determine the neutrino mass ordering. DUNE consists of near and far detectors that rely on liquid argon time projection chamber (LArTPC) technology to observe neutrino interactions. The near detector (ND) will be placed in Fermilab, near the neutrino source, while the far detector (FD) will be deployed in Sanford Lab, 1.5 km deep underground, which is 1300 km away from the source. LArTPCs provide excellent particle identification and calorimetry; however, detecting neutrons is challenging, as they do not leave direct ionization signals in LArTPCs. Neutrons can carry away up to 25% of the neutrino energy, introducing a significant uncertainty in DUNE measurements. The DUNE near detector (ND) features a novel modular LArTPC with pixelated charge readout, which enhances event recons truction. The modular design enables precise correlation between ionization signals and light signals in a high-rate environment, improving the identification of delayed energy depositions from neutrons in neutrino interactions. We introduce a neutron tagging technique using the 2x2 Demonstrator, a small-scale prototype of the DUNE ND LArTPC. The analysis utilizes Monte Carlo simulations and deep-learning techniques to identify neutron-induced energy depositions and reconstruct low-energy activity.

Kufatty, Georgette [Florida State U.]↗

Fermilab Italian Student Program (Final Report)

I participated to the 2019 Fermilab Italian Student Program under the supervision of Anadi Canepa and Lorenzo Uplegger. I worked with the Fermilab research group that is involved with the R&D of the CMS Outer Tracker. The Compact Muon Solenoid (CMS) is a a general-purpose detector located at the Large Hadron Collider (LHC), the world's most powerful particle accelerator. In the next years LHC will undergo the High-Luminosity LHC upgrade, which will bring its luminosity from 1 × 10 34 cm -2 s -1 to 1.5 × 10 34 cm -2 s -1 . This increase in luminosity will require an upgrade of CMS as well, in order to comply with the augmented rate of particles which will cross the detector. The CMS tracker is a detector, composed of various modules made of silicon pixel trackers and silicon strip trackers, whose aim is to reconstruct the trajectories of the particles produced by the collisions in LHC. The tracker is ideally divided in Inner Tracker and Outer Tracker. The HL-LHC upgrade put important challenges in the designing of the tracker. It will have to withstand the irradiation of a large fluence of particles, without suffering a too severe deterioration of its performance. In addition to this, in order to comply with the increased rate of events that CMS will need to detect, the tracker will be exploited for triggering at the fully hardware Level 1 Trigger, in contrast to the current tracker, whose data are only used for the software High-Level Trigger. This feature is managed by the "stub logic", which will be explained in chapter 2. During the months of August and September at Fermilab I carried out the data analysis of three test beam runs performed in the last two years on the 2S Outer Tracker Minimules. The 2S Minimoule consists of two silicon strip trackers placed one upon the other with the strips kept parallel.

43 PARTICLE ACCELERATORS↗

Development of a High Resolution X-Ray Imaging Crystal Spectrometer for Measurement of Ion-Temperature and Rotation-Velocity Profiles in Fusion Energy Research Plasmas

A new imaging high resolution x-ray crystal spectrometer (XCS) has been developed to measure continuous profiles of ion temperature and rotation velocity in fusion plasmas. Following proof-of-principle tests on the Alcator C-Mod tokamak and the NSTX spherical tokamak, and successful testing of a new silicon, pixilated detector with 1 MHz count rate capability per pixel, an imaging XCS is being designed to measure full profiles of Ti and vφ on C-Mod. The imaging XCS design has also been adopted for ITER. Ion-temperature uncertainty and minimum measurable rotation velocity are calculated for the C-Mod spectrometer. The affects of x-ray and uclear-radiation background on the measurement uncertainties are calculated to predict performance on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Investigation of large format microchannel plate Z configurations

The performance of triplet (Z) stacks of microchannel plates (MCPs) has been studied as a part of the instrument development for the Extreme Ultraviolet Explorer (EUVE) satellite mission. Relatively large MCPs with a 60-mm diameter and having a large 80:1 channel length to diameter (L:D) ratio were used in several configurations. The MCPs were used in the EUVE prototype imaging detector to provide more than 512 x 512 pixels with low image distortion (less than 1 percent). The gain and pulse height characteristics of the MCPs were examined, showing that both high gains (more than 2 x 10 to the 7th) and tight output pulse height distributions (less than 30 percent FWHM) may be achieved. Simple distribution techniques have also allowed low intrinsic background event rates (less than 0.15 events per sq cm/s) to be obtained. Variation of the quantum efficiency of the MCPs over the wavelength range 160-1216 A has been investigated for a range of angles of incidence. The effect of temperature variations on MCP operating characteristics has also been evaluated.

Siegmund, O. H. W.↗

An intensified CCD detector using the phosphor TPB

The Research Amplifying Imaging Detector consists of a microchannel plate image intensifier with a thin coating (3500-10,000 A) of the phosphor tetraphenyl-butadiene (TPB) on the entrance window to convert EUV radiation to visible, and coupled via a lens to a CCD detector. This design allows great flexibility in selecting the pixel size and field of view, with a simple mechanical design. The phosphor appears to be quite rugged, with no degradation having appeared during several months of testing both in and out of vacuum. Tests have been made at visible and EUV (304 A) wavelengths of the following performance aspects: EUV spectral sensitivity, spatial resolution (both of components and of the system as a whole), noise, linearity, and dynamic range. An improved detector for the Coronal Diagnostic Spectrometer experiment on the Solar Heliospheric Observatory satellite is being presently designed.

Thompson, William T.↗

Tropospheric Emission Spectrometer for the Earth Observing System

A Tropospheric Emission Spectrometer (TES) for the Earth Observing System (EOS) series of polar-orbiting platforms is described. TES is aimed at studying tropospheric chemistry, in particular, the exchange of gases between the surface and the atmosphere, urban and regional pollution, acid rain precursors, sources and sinks of greenhouse gases, and the interchange of gases between the troposphere and the stratosphere. TES is a high-resolution (0.025/cm) infrared Fourier transform spectrometer operating in the passive thermal-emission mode in a very wide spectral range (600 to 4350/cm; 2.3 to 16.7 microns). TES has 32 spatial pixels in each of four optically conjugated linear detector arrays, each optimized for a different spectral region.

Glavich, Thomas A.↗

Focal Plane Arrays of Voltage-Biased Superconducting Bolometers

The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.

Myers, Michael J.↗

SHARC II: A Caltech Submillimeter Observatory Facility Camera with 384 Pixels

SHARC II is a background-limited 350 micron and 450 micron facility camera for the Caltech Submillimeter Observatory undergoing commissioning in 2002. The key component of SHARC II is a 12 x 32 array of doped silicon 'pop-up' bolometers developed at NASA/Goddard. Each 1 mm x 1 mm pixel is coated with a 400 Omega/square bismuth film and located lambda/4 above a reflective backshort to achieve greater than 75% absorption efficiency. The pixels cover the focal plane with greater than 90% filling factor. At 350 microns, the SHARC II pixels are separated by 0.65 lambda/D. In contrast to the silicon bolometers in the predecessor of SHARC II, each doped thermistor occupies nearly the full area of the pixel, which lowers the 1/f knee of tile detector noise to less than 0.03 Hz, under load, at tile bath temperature of 0.36 K. The bolometers are AC-biased and read in 'total power' mode to take advantage of the improved stability. Each bolometer is biased through a custom approx. 130 MOmega CrSi load resistor at 7 K and read with a commercial JFET at 120 K. The JFETs and load resistors are integrated with the detectors into a single assembly to minimize microphonic noise. Electrical connection across the 0.36 K to 4 K and 4 K to 120 K temperature interfaces is accomplished with lithographed metal wires on dielectric substrates. In the best 25% of winter nights on Mauna Kea, SHARC II is expected to have an NEFD at 350 micron of 1 Jy Hz(sup -1/2) or better. The new camera should be at least 4 times faster at detecting known point sources and 30 times faster at mapping large areas compared to the prior instrument.

Dowell, C. Darren↗

Pointing Reference Scheme for Free-Space Optical Communications Systems

A scheme is proposed for referencing the propagation direction of the transmit laser signal in pointing a free-space optical communications terminal. This recently developed scheme enables the use of low-cost, commercial silicon-based sensors for tracking the direction of the transmit laser, regardless of the transmit wavelength. Compared with previous methods, the scheme offers some advantages of less mechanical and optical complexity and avoids expensive and exotic sensor technologies. In free-space optical communications, the transmit beam must be accurately pointed toward the receiver in order to maintain the communication link. The current approaches to achieve this function call for part of the transmit beam to be split off and projected onto an optical sensor used to infer the pointed direction. This requires that the optical sensor be sensitive to the wavelength of the transmit laser. If a different transmit wavelength is desired, for example to obtain a source capable of higher data rates, this can become quite impractical because of the unavailability or inefficiency of sensors at these wavelengths. The innovation proposed here decouples this requirement by allowing any transmit wavelength to be used with any sensor. We have applied this idea to a particular system that transmits at the standard telecommunication wavelength of 1,550 nm and uses a silicon-based sensor, sensitive from 0.5 to 1.0 micrometers, to determine the pointing direction. The scheme shown in the figure involves integrating a low-power 980-nm reference or boresight laser beam coupled to the 1,550-nm transmit beam via a wavelength-division-multiplexed fiber coupler. Both of these signals propagate through the optical fiber where they achieve an extremely high level of co-alignment before they are launched into the telescope. The telescope uses a dichroic beam splitter to reflect the 980- nm beam onto the silicon image sensor (a quad detector, charge-coupled device, or active-pixel-sensor array) while the 1,550- nm signal beam is transmitted through the optical assembly toward the remotely located receiver. Since the 980-nm reference signal originates from the same single-mode fiber-coupled source as the transmit signal, its position on the sensor is used to accurately determine the propagation direction of the transmit signal. The optics are considerably simpler in the proposed scheme due to the use of a single aperture for transmitting and receiving. Moreover, the issue of mechanical misalignment does not arise because the reference signal and transmitted laser beams are inherently co-aligned. The beam quality of the 980-nm reference signal used for tracking is required to be circularly symmetric and stable at the tracking-plane sensor array in order to minimize error in the centroiding algorithm of the pointing system. However, since the transmit signal is delivered through a fiber that supports a single mode at 1,550 nm, propagation of higher order 980-nm modes is possible. Preliminary analysis shows that the overall mode profile is dominated by the fundamental mode, giving a near symmetric profile. The instability of the mode was also measured and found to be negligible in comparison to the other error contributions in the centroid position on the sensor array.

Wright, Malcolm↗

III-V Infrared Research at the Jet Propulsion Laboratory

Jet Propulsion Laboratory is actively developing the III-V based infrared detector and focal plane arrays (FPAs) for NASA, DoD, and commercial applications. Currently, we are working on multi-band Quantum Well Infrared Photodetectors (QWIPs), Superlattice detectors, and Quantum Dot Infrared Photodetector (QDIPs) technologies suitable for high pixel-pixel uniformity and high pixel operability large area imaging arrays. In this paper we report the first demonstration of the megapixel-simultaneously-readable and pixel-co-registered dual-band QWIP focal plane array (FPA). In addition, we will present the latest advances in QDIPs and Superlattice infrared detectors at the Jet Propulsion Laboratory.

Dualband↗

Performance of Backshort-Under-Grid Kilopixel TES Arrays for HAWC+

We present results from laboratory detector characterizations of the first kilopixel BUG arrays for the High- resolution Wideband Camera Plus (HAWC+) which is the imaging far-infrared polarimeter camera for the Stratospheric Observatory for Infrared Astronomy (SOFIA). Our tests demonstrate that the array performance is consistent with the predicted properties. Here, we highlight results obtained for the thermal conductivity, noise performance, detector speed, and first optical results demonstrating the pixel yield of the arrays.

Staguhn, J. G.↗