Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Application of the GRC Stirling Convertor System Dynamic Model

The GRC Stirling Convertor System Dynamic Model (SDM) has been developed to simulate dynamic performance of power systems incorporating free-piston Stirling convertors. This paper discusses its use in evaluating system dynamics and other systems concerns. Detailed examples are provided showing the use of the model in evaluation of off-nominal operating conditions. The many degrees of freedom in both the mechanical and electrical domains inherent in the Stirling convertor and the nonlinear dynamics make simulation an attractive analysis tool in conjunction with classical analysis. Application of SDM in studying the relationship of the size of the resonant circuit quality factor (commonly referred to as Q) in the various resonant mechanical and electrical sub-systems is discussed.

Regan, Timothy F.↗

Improved Estimate of Phobos Secular Acceleration from MOLA Observations

We report on new observations of the orbital position of Phobos, and use them to obtain a new and improved estimate of the rate of secular acceleration in longitude due to tidal dissipation within Mars. Phobos is the inner-most natural satellite of Mars, and one of the few natural satellites in the solar system with orbital period shorter than the rotation period of its primary. As a result, any departure from a perfect elastic response by Mars in the tides raised on it by Phobos will cause a transfer of angular momentum from the orbit of Phobos to the spin of Mars. Since its discovery in 1877, Phobos has completed over 145,500 orbits, and has one of the best studied orbits in the solar system, with over 6000 earth-based astrometric observations, and over 300 spacecraft observations. As early as 1945, Sharpless noted that there is a secular acceleration in mean longitude, with rate (1.88 + 0.25) 10(exp -3) degrees per square year. In preparation for the 1989 Russian spacecraft mission to Phobos, considerable work was done compiling past observations, and refining the orbital model. All of the published estimates from that era are in good agreement. A typical solution (Jacobson et al., 1989) yields (1.249 + 0.018) 10(exp -3) degrees per square year. The MOLA instrument on MGS is a laser altimeter, and was designed to measure the topography of Mars. However, it has also been used to make observations of the position of Phobos. In 1998, a direct range measurement was made, which indicated that Phobos was slightly ahead of the predicted position. The MOLA detector views the surface of Mars in a narrow field of view, at 1064 nanometer wavelength, and can detect shadows cast by Phobos on the surface of Mars. We have found 15 such serendipitous shadow transit events over the interval from xx to xx, and all of them show Phobos to be ahead of schedule, and getting progressively farther ahead of the predicted position. In contrast, the cross-track positions are quite close to the predicted values. Assuming that the along-track discrepancy is small enough that we can linearize the corrections, we model the mean orbital longitude as a quadratic function of time, and solve for corrections to the constant, linear, and quadratic terms. The time span of the recent observations is insufficient to properly resolve this issue alone, but when the 127 years of prior observations are added, we find a solution which reduces misfit to the new observations considerably, and makes no significant change to the fit to earlier observations. Our estimate for the secular acceleration term is (1.367 + 0.006) degrees per square year. The corresponding rate of energy dissipation is 3.34 MW. From a geophysical perspective, a more interesting parameter than the secular acceleration itself is the tidal lag angle, or tidal quality factor Q, for Mars. Unfortunately, the limiting error source in that determination is remaining uncertainty in the tidal Love numbers at harmonic degrees 2,3, and even 4. Until those parameters are better constrained, improvement in the orbital model of Phobos will not provide corresponding benefits for understanding the interior of Mars.

Bills, Bruce↗

A Superfluid Clock

The performance of clocks is limited by the characteristics of the underlying oscillator. Both the quality factor of the oscillator and the signal-to-noise ratio for the resonator state measurement are important. A superfluid helium Helmholtz resonator operating at approx.100mK temperatures has the potential of maintaining frequency stability of 5x10(exp -15)/t(exp 1/2) on the time scale of a few months. The high dynamic range of lossless SQUID position displacement measurement, and low losses associated with the superfluid flow, combined with high mechanical stability of cryogenic assemblies, contribute to the projected stability. Low overall mass of the assembly allows for multiple stages of vibration isolation.

Penanen, Konstantin↗

Tunability and synthetic lineshapes in high-Q optical whispering gallery modes

We demonstrate novel techniques to manipulate spectral properties of high quality factor (Q>107) whispering-gallery modes (WGM) in optical dielectric microresonators. These include permanent frequency trimming of WGM frequencies by means of UV photosensitivity of germanium doped silica resonators electro-optical tuning of WGM in lithium niobate resonators, and cascading of microresonators for obtaining second-order filtering function. We present theoretical interpretation of experimental results, and application example of techniques for photonic microwave filtering.

optical filters↗

Photorefractivity in WGM resonators

We report on observation of photorefractive effects in whispering gallery mode resonators made of as-grown and magnesium doped lithium niobate and lithium tantalate in the near as well as far infrared. The effects manifested themselves as dynamic modification of the spectra as well as quality factors of the resonators coupled to the laser radiation. We have observed a significant (exceeding 10-4) change of the ordinary index of refraction of all the materials exposed with 780 nm light. Photorefractive effects have also been detected at 1550 nm. Our experiments support the conclusion that the photorefractivity does not have a distinct red boundary. We show that the maximum saturated refractive index change in the infrared is of the same order of magnitude as in the visible light.

optical resonator↗

Optimization of Crew Shielding Requirement in Reactor-Powered Lunar Surface Missions

On the surface of the moon -and not only during heightened solar activities- the radiation environment As such that crew protection will be required for missions lasting in excess of six months. This study focuses on estimating the optimized crew shielding requirement for lunar surface missions with a nuclear option. Simple, transport-simulation based dose-depth relations of the three (galactic, solar, and fission) radiation sources am employed in a 1-dimensional optimization scheme. The scheme is developed to estimate the total required mass of lunar-regolith separating reactor from crew. The scheme was applied to both solar maximum and minimum conditions. It is shown that savings of up to 30% in regolith mass can be realized. It is argued, however, that inherent variation and uncertainty -mainly in lunar regolith attenuation properties in addition to the radiation quality factor- can easily defeat this and similar optimization schemes.

Barghouty, Abdulnasser F.↗

Engineered Carbon Nanotube Materials for High-Q Nanomechanical Resonators

This document represents a presentation offered by the Jet Propulsion Laboratory, with assistance from researchers from Brown University and Northrop Grumman. The presentation took place in Seoul, Korea in July 2003 and attempted to demonstrate the fabrication approach regarding the development of high quality factor (high-Q) mechanical oscillators (in the forms of a tunable nanotube resonator and a nanotube array radio frequency [RF] filter) aimed at signal processing and based on carbon nanotubes. The presentation also addressed parallel efforts to develop both in-plane single nanotube resonators as well as vertical array power devices.

chemical vapor depositions↗

Recent Low-Earth Orbit Radiation Measurements Using Passive Dosimeters during ISS Expeditions 13, 14 and 15

Current passive radiation measurements in low-Earth orbit (LEO) involve using a combination of thermally/optically stimulated luminescence detectors (TLDs/OSLDs) for the low-LET component (LET<10 keV/micron water) of the space radiation field and plastic nuclear track detectors (PNTDs) for the high-LET region (LET>10 keV/micron water), as per National Council on Radiation Protection recommendation (NCRP 132, 2004). This combination of radiation detectors has been successfully implemented at NASA Johnson Space Center for routine crewmember and ISS area monitoring using LiF:Mg,Ti, CaF2:Tm, Al2O3:C and CR-39 material. This paper will present in detail the measurement and data processing techniques employed for passive space radiation measurements by the Space Radiation Analysis Group (SRAG) at JSC. The paper will also summarize the absorbed dose, dose equivalent and quality factor results for the area monitoring during ISS Expeditions 13, 14 and 15.

Gaza, R.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

Optimization of Crew Shielding Requirement in Reactor-Powered Lunar Surface Missions

On the surface of the moon and not only during heightened solar activities the radiation environment is such that crew protection will be required for missions lasting in excess of six months. This study focuses on estimating the optimized crew shielding requirement for lunar surface missions with a nuclear option. Simple, transport-simulation based dose-depth relations of the three radiation sources (galactic, solar, and fission) are employed in a one-dimensional optimization scheme. The scheme is developed to estimate the total required mass of lunar regolith separating reactor from crew. The scheme was applied to both solar maximum and minimum conditions. It is shown that savings of up to 30% in regolith mass can be realized. It is argued, however, that inherent variation and uncertainty mainly in lunar regolith attenuation properties in addition to the radiation quality factor can easily defeat this and similar optimization schemes.

Barghouty, A. F.↗

Space Radiation Induced Cytogenetic Damage in the Blood Lymphocytes of Astronauts

Cytogenetic analysis of astronauts blood lymphocytes provides a direct in vivo measurement of space radiation damage, which takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. We present our latest analyses of chromosome damage in astronauts blood lymphocytes assessed by fluorescence in situ hybridization (FISH) chromosome painting and collected at various times beginning directly after return from space to several years after flight. Dose was derived from frequencies of chromosome exchanges using preflight calibration curves, and the Relative Biological Effect (RBE) was estimated by comparison with individually measured physically absorbed doses. Values for average RBE were compared to the average quality factor (Q), from direct measurements of the lineal energy spectra using a tissue-equivalent proportional counter (TEPC) and radiation transport codes. Results prove that cytogenetic biodosimetry analyses on blood collected within a week or two of return from space provides a reliable estimate of equivalent radiation dose and risk after protracted exposure to space radiation of a few months or more. However, data collected several months or years after flight suggests that the yield of chromosome translocations may decline with time after the mission, indicating that retrospective doses may be more difficult to estimate. In addition, limited data on multiple flights show a lack of correlation between time in space and translocation yields. Data from one crewmember, who has participated in two separate long-duration space missions and has been followed up for over 10 years, provide limited information on the effect of repeat flights and show a possible adaptive response to space radiation exposure.

George, K.↗

The USNA MIDN Microdosimeter Instrument

This paper describes the MIcroDosimetry iNstrument (MIDN) mission now under development at the United States Naval Academy. The instrument is manifested to fly on the MidSTAR-1 spacecraft, which is the second spacecraft to be developed and launched by the Academy s faculty and midshipmen. Launch is scheduled for 1 September 2006 on an ATLAS-5 launch vehicle. MIDN is a rugged, portable, low power, low mass, solid-state microdosimeter designed to measure in real time the energy distributions of energy deposited by radiation in microscopic volumes. The MIDN microdosimeter sensor is a reverse-biased silicon p-n junction array in a Silicon-On-Insulator (SOI) configuration. Microdosimetric frequency distributions as a function of lineal energies determine the radiation quality factors in support of radiation risk estimation to humans.

Pisacane, V. L.↗

Discovery of a Neutron Star with Spin Frequency 530 Hz in A1744-361

We report the detection with the Rossi X-ray Timing Explorer (RXTE) Proportional Counter Array (PCA) of 530 Hz burst oscillations in a thermonuclear (Type I) burst from the transient X-ray source A1744-361. This is only the second burst ever observed from this source, and the first to be seen in any detail. Our results confirm that A1744-361 is a low mass X-ray binary (LMXB) system harboring a rapidly rotating neutron star. The oscillations are first detected along the rising edge of the burst, and show evidence for frequency evolution of a magnitude similar to that seen in other burst sources. The modulation amplitude and its increase with photon energy are also typical of burst oscillations. The lack of any strong indication of photospheric radius expansion during the burst suggests a 9 kpc upper limit of the source distance. We also find energy dependent dips, establishing A1744-361 as a high inclination, dipping LMXB. The timescale between the two episodes of observed dips suggests an orbital period of approx. 97 min. We have also detected a 2 - 4 Hz quasi-periodic-oscillation (QPO) for the first time from this source. This QPO appears consistent with approx. 1 Hz QPOs seen from other high inclination systems. We searched for kilohertz QPOs, and found a suggestive 2.3 sigma feature at 800 Hz in one observation. The frequency, strength and quality factor are consistent with that of a lower frequency kilohertz QPO, but the relatively low significance argues for caution, so we consider this a tentative detection requiring confirmation.

Bhattacharyya, Sudip↗

Superconducting Films for Absorber-coupled MKID Detectors for Sub-millimeter and Far-infrared Astronomy

We describe measurements of the properties, at dc, gigahertz, and terahertz frequencies, of thin superconducting films with relatively high normal state sheet resistance. Such films can be applied to construct microwave kinetic inductance detector sensor arrays for submillimeter and far-infrared astronomical applications in which the incident power excites quasiparticles directly in a superconducting resonator that is configured to present a matched-impedance to the high frequency radiation being detected. For several materials, and a range of thicknesses down to 10 nm, we present measurements of normal state sheet resistance, resistance-temperature curves for the superconducting transition, quality factor and kinetic inductance fraction for microwave resonators made from patterned films, and terahertz measurements of the sheet impedance measured with a Fourier Transform Spectrometer.

Stevenson, T. R.↗

Phase Matching of Diverse Modes in a WGM Resonator

Phase matching of diverse electromagnetic modes (specifically, coexisting optical and microwave modes) in a whispering-gallery-mode (WGM) resonator has been predicted theoretically and verified experimentally. Such phase matching is necessary for storage of microwave/terahertz and optical electromagnetic energy in the same resonator, as needed for exploitation of nonlinear optical phenomena. WGM resonators are used in research on nonlinear optical phenomena at low optical intensities and as a basis for design and fabrication of novel optical devices. Examples of nonlinear optical phenomena recently demonstrated in WGM resonators include low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations. The present findings regarding phase matching were made in research on low-threshold, strongly nondegenerate parametric oscillations in lithium niobate WGM resonators. The principle of operation of such an oscillator is rooted in two previously observed phenomena: (1) stimulated Raman scattering by polaritons in lithium niobate and (2) phase matching of nonlinear optical processes via geometrical confinement of light. The oscillator is partly similar to terahertz oscillators based on lithium niobate crystals, the key difference being that a novel geometrical configuration of this oscillator supports oscillation in the regime. The high resonance quality factors (Q values) typical of WGM resonators make it possible to achieve oscillation at a threshold signal level much lower than that in a non-WGM-resonator lithium niobate crystal.

Savchenkov, Anatoliy↗

Wide-Band Microwave Receivers Using Photonic Processing

In wide-band microwave receivers of a type now undergoing development, the incoming microwave signals are electronically preamplified, then frequency-up-converted to optical signals that are processed photonically before being detected. This approach differs from the traditional approach, in which incoming microwave signals are processed by purely electronic means. As used here, wide-band microwave receivers refers especially to receivers capable of reception at any frequency throughout the range from about 90 to about 300 GHz. The advantage expected to be gained by following the up-conversion-and-photonic-processing approach is the ability to overcome the limitations of currently available detectors and tunable local oscillators in the frequency range of interest. In a receiver following this approach (see figure), a preamplified incoming microwave signal is up-converted by the method described in the preceeding article. The frequency up-converter exploits the nonlinearity of the electromagnetic response of a whispering gallery mode (WGM) resonator made of LiNbO3. Up-conversion takes place by three-wave mixing in the resonator. The WGM resonator is designed and fabricated to function simultaneously as an electro-optical modulator and to exhibit resonance at the microwave and optical operating frequencies plus phase matching among the microwave and optical signals circulating in the resonator. The up-conversion is an efficient process, and the efficiency is enhanced by the combination of microwave and optical resonances. The up-converted signal is processed photonically by use of a tunable optical filter or local oscillator, and is then detected. Tunable optical filters can be made to be frequency agile and to exhibit high resonance quality factors (high Q values), thereby making it possible to utilize a variety of signal-processing modalities. Therefore, it is anticipated that when fully developed, receivers of this type will be compact and will be capable of both wide-band and narrowband signal processing. Thus, one compact receiver of this type would afford the functionality that, heretofore, could have been obtained only by use of multiple heterodyne microwave receivers.

Matsko, Andrey↗