Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Role of Material Condition in Precursor Corrosion Damage and Stress Corrosion Crack Initiation Behavior of Alloy 600 in PWR Primary Water

Stress corrosion crack (SCC) initiation testing has been performed on a 15% cold-worked UNS N06600 (Alloy 600) heat in the mill-annealed (MA), solution annealed (SA), and thermally treated (TT) conditions to assess the role of grain boundary (GB) carbides on stress-assisted intergranular attack (IGA) and short crack nucleation and growth. The SCC initiation tests were conducted at constant load equivalent to materials yield stress in 360oC simulated PWR primary water with dissolved hydrogen at the Ni/NiO stability line. Results revealed the highest SCC initiation susceptibility in the Alloy 600 MA material followed by the TT and SA materials, suggesting the GB carbide distribution did not have a controlling effect on SCC initiation resistance. Quantitative assessments were conducted on IGA and short cracks to help understand this phenomenon and the role of GB carbides on precursor damage development that lead to differences in macroscopic SCC initiation behavior are discussed.

Zhai, Ziqing↗

How to Obtain Reproducible Results for Lithium Sulfur Batteries

The basic requirements for getting reliable Li-S battery data have been discussed in this work. Unlike Li-ion batteries, electrolyte-rich environment significantly affects the cycling stability of Li-S batteries prepared and tested under the same conditions. The reason has been assigned to the different concentrations of polysulfide-containing electrolytes in the cells, which have profound influences on both sulfur cathode and lithium anode. At optimized S/E ratio of 50 g L-1, a good balance among electrolyte viscosity, wetting ability, diffusion rate dissolved polysulfide and nucleation/growth of short-chain Li2S/Li2S2 has been built along with largely reduced contamination on the lithium anode side. Accordingly, good cyclability, high reversible capacity and Coulombic efficiency are achieved in Li-S cell with controlled S/E ratio without any additive. Other factors such as sulfur content in the composite and sulfur loading on the electrode also need careful concern in Li-S system in order to generate reproducible results and gauge the various methods used to improve Li-S battery technology.

Cycling stability↗

Chemical Characterization and Reactivity of Fuel-Oxidizer Reaction Product

Fuel-oxidizer reaction product (FORP), the product of incomplete reaction of monomethylhydrazine and nitrogen tetroxide propellants prepared under laboratory conditions and from firings of Shuttle Reaction Control System thrusters, has been characterized by chemical and thermal analysis. The composition of FORP is variable but falls within a limited range of compositions that depend on three factors: the fuel-oxidizer ratio at the time of formation; whether the composition of the post-formation atmosphere is reducing or oxidizing; and the reaction or post-reaction temperature. A typical composition contains methylhydrazinium nitrate, ammonium nitrate, methylammonium nitrate, and trace amounts of hydrazinium nitrate and 1,1-dimethylhydrazinium nitrate. Thermal decomposition reactions of the FORP compositions used in this study were unremarkable. Neither the various compositions of FORP, the pure major components of FORP, nor mixtures of FORP with propellant system corrosion products showed any unusual thermal activity when decomposed under laboratory conditions. Off-limit thruster operations were simulated by rapid mixing of liquid monomethylhydrazine and liquid nitrogen tetroxide in a confined space. These tests demonstrated that monomethylhydrazine, methylhydrazinium nitrate, ammonium nitrate, or Inconel corrosion products can induce a mixture of monomethylhydrazine and nitrogen tetroxide to produce component-damaging energies. Damaging events required FORP or metal salts to be present at the initial mixing of monomethylhydrazine and nitrogen tetroxide.

David, Dennis D.↗

Acid Gas Capture Using CO2-Binding Organic Liquids

Current chemical CO2 scrubbing technology is primarily aqueous alkanolamine based. These systems rapidly bind CO2 (forming water-soluble carbamate and bicarbonate salts) however, the process has serious disadvantages. The concentration of monoethanolamine rarely exceeds 30 wt % due to the corrosive nature of the solution, and this reduces the maximum CO2 volumetric (≤108 g/L) and gravimetric capacity (≤7 wt%) of the CO2 scrubber. The ≤30 wt % loading of ethanolamine also means that a large excess of water must be pumped and heated during CO2 capture and release, and this greatly increases the energy requirements especially considering the high specific heat of water (4 j/g-1K-1). Our approach is to switch to organic systems that chemically bind CO2 as liquid alkylcarbonate salts. Our CO2-binding organic liquids have higher CO2 solubility, lower specific heats, potential for less corrosion and lower binding energies for CO2 than aqueous systems. CO2BOLs also reversibly bind and release mixed sulfur oxides. Furthermore the CO2BOL system can be direct solvent replacements for any solvent based CO2 capture systems because they are commercially available reagents and because they are fluids they would not require extensive process re-engineering.

54 ENVIRONMENTAL SCIENCES↗

CONTINUOSLY STIRRED TANK REACTOR PARAMETERS THAT AFFECT SLUDGE BATCH 6 SIMULANT PROPERTIES

The High Level Radioactive Waste (HLW) Sludge in Savannah River Site (SRS) waste tanks was produced over a period of over 60 years by neutralizing the acidic waste produced in the F and H Separations Canyons with sodium hydroxide. The HLW slurries have been stored at free hydroxide concentrations above 1 M to minimize the corrosion of the carbon steel waste tanks. Sodium nitrite is periodically added as a corrosion inhibitor. The resulting waste has been subjected to supernate evaporation to minimize the volume of the stored waste. In addition, some of the waste tanks experienced high temperatures so some of the waste has been at elevated temperatures. Because the waste is radioactive, the waste is transforming through the decay of shorter lived radioactive species and the radiation damage that the decay releases. The goal of the Savannah River National Laboratory (SRNL) simulant development program is to develop a method to produce a sludge simulant that matches both the chemical and physical characteristics of the HLW without the time, temperature profile, chemical or radiation exposure of that of the real waste. Several different approaches have been taken historically toward preparing simulated waste slurries. All of the approaches used in the past dozen years involve some precipitation of the species using similar chemistry to that which formed the radioactive waste solids in the tank farm. All of the approaches add certain chemical species as commercially available insoluble solid compounds. The number of species introduced in this manner, however, has varied widely. All of the simulant preparation approaches make the simulated aqueous phase by adding the appropriate ratios of various sodium salts. The simulant preparation sequence generally starts with an acidic pH and ends up with a caustic pH (typically in the 10-12 range). The current method for making sludge simulant involves the use of a temperature controlled continuously stirred tank reactor (CSTR). Precipitated MnO{sub 2} is combined with metal nitrates and fed into the CSTR. The metals are precipitated by a caustic NaOH stream. The rates at which these streams are added allows for pH adjustment of the mixture. A graphical representation of this process is given in Figure 1. In using the CSTR method for developing simulant, there are various parameters that can be adjusted in order to effectuate a physical change in the resulting simulant: pH, temperature, mixing speed, and flow rate. How will changing these parameters affect the physical properties of the sludge simulant? The ability to determine which parameter affects a particular property could allow one to develop a simulant that would better match the physical characteristics of HLW sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Burn coal cleanly in a fluidized bed - The key is in the controls

The fluidized-bed combustion (FBC) process produces few sulfur emissions, and can burn wood, municipal solid waste as well as every kind of coal available in the U.S. The presurized, coal-burning fluidized-bed reactor at NASA's Lewis Research Center is described, together with a discussion of the operating results. The FBC system at Lewis, having a completely instrumented reactor, is used to test turbine blade alloys for future power plant applications. With the same type of coal and limestone used in the first testing phase covering 136 hours, it was found that all NOx values were below the EPA standard of 0.7 lb/MBtu, whereas the maximum observed level of SO2 was above the EPA standard of 1.3 lb/MBtu, but with the average SO2 level, however, only 0.63 lb/MBtu. Unburned hydrocarbon and CO levels were very low, indicating combustion efficiencies of close to 99% in almost all tests. Testing is now underway using high temperature cyclones and gas turbine to eliminate erosion and corrosion effects which were observed after the initial tests on the turbine and blades.

Kobak, J. A.↗

Report on Data Quality Required for Modeling an MSR

Calculations were performed to assess how uncertainties in molten salt property values impact the results of behavior models of molten salt reactor systems under steady-state conditions. The thermophysical and thermochemical properties of salt mixtures being considered for use in molten salt reactors are not yet well characterized and methods used to measure property values to molten salts are not yet well established. The limited property data for salts of interest that are available in the literature are inconsistent and unreliable. Many methods used to measure property values remain developmental in the sense that not all variables affecting measured values have been identified or controlled during the measurement and not all aspects of the measurements affecting data quality are calibrated. A prior report described the repeatability of measurements made at Argonne and the reproducibility of measurements made with the same salts at several institutions is being evaluated. There is significant uncertainty in measured property values due to instrumental limitations and the effects of contaminants in the salts used to make the measurements that impacts predictions of salt behavior in a reactor. Most salts of interest are multicomponent eutectic or near-eutectic mixtures and both uncertainty in the salt composition and uncertainty in measured values. Furthermore, the salt composition evolves over time due to the uptake of impurities from the atmosphere and corrosion of containment vessels. More significantly, fission products will accumulate during operation that change the salt compositions and property values. MSR developers need to understand how this uncertainty in the basic property data of the fuel will impact modeling predictions for normal reactor operation as well was in transient scenarios that will impact the safety basis. The calculations and analyses in this report address the impact of uncertainty in measured property values under steady-state conditions through a generalized parametric study. The pooled uncertainty from contributions by a number of factors were considered and quantified, including varying composition due to impurities and fission products, imprecision in the measured values, and uncontrolled aspects of the measurement. In this way, we can begin to gain an understanding of the magnitude of the impact uncertainty will have in modeling MSR systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prognostic model and failure mechanisms of steam generators in Sodium-Cooled fast reactors

This paper presents a prognostic model for sodium-cooled fast reactor (SFR) steam generators (SGs). Here, the purpose of the model is to estimate the remaining useful life of SFR SGs and thus to support the decision-making of autonomous control. SFR SGs are of great interest for plant integrity due to their harsh operation environment. They operate at higher temperatures and higher coolant-to-steam pressure differences than those of current light water reactors (LWR). The severity of the SFR SG failure consequences, which include water-sodium contact, is another reason. Understanding its failure mechanisms is important for the development of its prognostic model. Based on our literature review and physics-based analysis, we concluded that creep would be a dominant degradation mode of SFR SGs due to SFR’s high-temperature and high-pressure environment. Thus, creep is the focus of the prognostic model. Various other failure modes were also investigated in this study. The mechanical fatigue due to flow-induced vibration is usually observed in early developmental phases and would not be an important issue during normal operation. The thermal fatigue due to thermal stripping is occasionally observed in other components in SFRs but does not affect SG integrity. Pure water stress corrosive crack, fretting, and so on are commonly observed in LWR SGs but are significantly less important in SFR SGs because of the high temperatures, high pressure differences, and chemical properties of liquid sodium. Based on these investigations, a prognostic model focusing on creep failures was developed. It estimates the failure probability profile by sampling the Larson-Miller parameter (LMP) and temperature and associated uncertainties through Monte Carlo methods. Two case studies were presented. The first one demonstrated the model’s capability to calculate the failure probability for a new specimen within a given time. If the tube is working under temperatures of 500C ± 3 and pressures of 15.2 MPa, which leads to LMP of 20,100 ± 50, the failure probabilities within 50, 70, and 90 years are approximately 0.1 %, 3.2 %, and 17.5 %. The second demonstrated how adjusting the workload can help to protect the integrity of the component. For an old tube reaching 99 % of its lifespan, continuing to run at temperatures of 500C ± 3 and LMP of 20,100 ± 50 leads to a failure probability of about 29.0 % within a year. If the temperature is reduced by 5C, the failure probability can be reduced to 2.5 %, and, if the pressure is also reduced such that the LMP is increased by 100, the failure probability can further be reduced to 0.12 %.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

NASA Tech Briefs, December 2003

Topics covered include: Organic/Inorganic Hybrid Polymer/Clay Nanocomposites; Less-Toxic Coatings for Inhibiting Corrosion of Aluminum; Liquid Coatings for Reducing Corrosion of Steel in Concrete; Processable Polyimides Containing APB and Reactive End Caps; Rod/Coil Block Copolyimides for Ion-Conducting Membranes; Techniques for Characterizing Microwave Printed Antennas; Cylindrical Antenna With Partly Adaptive Phased-Array Feed; Command Interface ASIC - Analog Interface ASIC Chip Set; Predicting Accumulations of Ice on Aerodynamic Surfaces; Analyzing Aeroelasticity in Turbomachines; Software for Allocating Resources in the Deep Space Network; Expert Seeker; High-Speed Recording of Test Data on Hard Disks; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Aerostructures Test Wing; Flight-Test Evaluation of Flutter-Prediction Methods; Piezoelectrically Actuated Microvalve for Liquid Effluents; Larger-Stroke Piezoelectrically Actuated Microvalve; Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost; Safer Roadside Crash Walls Would Limit Deceleration; Improved Interactive Medical-Imaging System; Scanning Microscopes Using X Rays and Microchannels; Slotting Fins of Heat Exchangers to Provide Thermal Breaks; Methane Clathrate Hydrate Prospecting; Automated Monitoring with a BSP Fault-Detection Test; Automated Monitoring with a BCP Fault-Decision Test; Vector-Ordering Filter Procedure for Data Reduction; Remote Sensing and Information Technology for Large Farms; Developments at the Advanced Design Technologies Testbed; Spore-Forming Bacteria that Resist Sterilization; and Acoustical Applications of the HHT Method.

Source record↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗

The John Deere E diesel Test & Research Project

Three non-road Tier II emissions compliant diesel engines manufactured by John Deere were placed on a durability test plan of 2000 hours each at full load, rated speed (FLRS). The fuel was a blend of 10% fuel ethanol and 90% low sulfur #2 diesel fuel. Seven operational failures involving twenty seven fuel system components occurred prior to completion of the intended test plan. Regulated emissions measured prior to component failure indicated compliance to Tier II certification goals for the observed test experience. The program plan included operating three non-road Tier II diesel engines for 2000 hours each monitoring the regulated emissions at 500 hour intervals for changes/deterioration. The program was stopped prematurely due to number and frequency of injection system failures. The failures and weaknesses observed involved injector seat and valve wear, control solenoid material incompatibility, injector valve deposits and injector high pressure seal cavitation erosion. Future work should target an E diesel fuel standard that emphasizes minimum water content, stability, lubricity, cetane neutrality and oxidation resistance. Standards for fuel ethanol need to require water content no greater than the base diesel fuel standard. Lubricity bench test standards may need new development for E diesel.

09 BIOMASS FUELS↗

Corrigendum to "Environmentally friendly, rheoreversible, hydraulic fracturing fluids for enhanced geothermal systems" [Geothermics 58 (2015) 22–31]

Cost-effective creation of high-permeability reservoirs inside deep crystalline bedrock is the primary challenge for the feasibility of enhanced geothermal systems (EGS). Current reservoir stimulation entails adverse environmental impacts and substantial economic costs due to the utilization of large volumes of water “doped” with chemicals including rheology modifiers, scale and corrosion inhibitors, biocides, friction reducers among others where, typically, little or no information of composition and toxicity is disclosed. An environmentally benign, CO2-activated, rheoreversible fracturing fluid has recently been developed that significantly enhances rock permeability at effective stress significantly lower than current technology. We evaluate the potential of this novel fracturing fluid for application on geothermal sites under different chemical and geomechanical conditions, by performing laboratory-scale fracturing experiments with different rock sources under different confining pressures, temperatures, and pH environments. The results demonstrate that CO2-reactive aqueous solutions of environmentally amenable Polyallylamine (PAA) represent a highly versatile fracturing fluid technology. This fracturing fluid creates/propagates fracture networks through highly impermeable crystalline rock at significantly lower effective stress as compared to control experiments where no PAA was present, and permeability enhancement was significantly increased for PAA compared to conventional hydraulic fracturing controls. This was evident in all experiments, including variable rock source/type, operation pressure and temperature (over the entire range for EGS applications), as well as over a wide range of formation-water pH values. This versatile novel fracturing fluid technology represents a great alternative to industrially available fracturing fluids for cost-effective and competitive geothermal energy production.

Shao, Hongbo↗

Membranes for corrosive oxidations. Final CRADA report.

The objective of this project is to develop porous hydrophilic membranes that are highly resistant to oxidative and corrosive conditions and to deploy them for recovery and purification of high tonnage chemicals such as hydrogen peroxide and other oxychemicals. The research team patented a process for membrane-based separation of hydrogen peroxide (US Patent No. 5,662,878). The process is based on using a hydrophilic membrane to separate hydrogen peroxide from the organic working solution. To enable this process, a new method for producing hydrophilic membrane materials (Patent No.6,464,880) was reported. We investigated methods of producing these hydrophilic materials and evaluated separations performance in comparison to membrane stability. It was determined that at the required membrane flux, membrane stability was not sufficient to design a commercial process. This work was published (Hestekin et al., J. Membrane Science 2006). To meet the performance needs of the process, we developed a membrane contactor method to extract the hydrogen peroxide, then we surveyed several commercial and pre-commercial membrane materials. We identified pre-commercial hydrophilic membranes with the required selectivity, flux, and stability to meet the needs of the process. In addition, we invented a novel reaction/separations format that greatly increases the performance of the process. To test the performance of the membranes and the new formats we procured and integrated reactor/membrane separations unit that enables controlled mixing, flow, temperature control, pressure control, and sampling. The results were used to file a US non-provisional patent application (ANL-INV 03-12). Hydrogen peroxide is widely used in pulp and paper applications, environmental treatment, and other industries. Virtually all hydrogen peroxide production is now based on a process featuring catalytic hydrogenation followed by auto-oxidation of suitable organic carrier molecules. This process has several drawbacks, particularly in the extraction phase. One general disadvantage of this technology is that hydrogen peroxide must be produced at large centralized plants where it is concentrated to 70% by distillation and transported to the users plant sites where it is diluted before use. Advanced membranes have the potential to enable more efficient, economic, and safe manufacture of hydrogen peroxide. Advanced membrane technology would allow filtration-based separation to replace the difficult liquid-liquid extraction based separation step of the hydrogen peroxide process. This would make it possible for hydrogen peroxide to be produced on-site in mini-plants at 30% concentration and used at the same plant location without distillation and transportation. As a result, production could become more cost-effective, safe and energy efficient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗