Calculations were performed to assess how uncertainties in molten salt property values impact the results of behavior models of molten salt reactor systems under steady-state conditions. The thermophysical and thermochemical properties of salt mixtures being considered for use in molten salt reactors are not yet well characterized and methods used to measure property values to molten salts are not yet well established. The limited property data for salts of interest that are available in the literature are inconsistent and unreliable. Many methods used to measure property values remain developmental in the sense that not all variables affecting measured values have been identified or controlled during the measurement and not all aspects of the measurements affecting data quality are calibrated. A prior report described the repeatability of measurements made at Argonne and the reproducibility of measurements made with the same salts at several institutions is being evaluated. There is significant uncertainty in measured property values due to instrumental limitations and the effects of contaminants in the salts used to make the measurements that impacts predictions of salt behavior in a reactor. Most salts of interest are multicomponent eutectic or near-eutectic mixtures and both uncertainty in the salt composition and uncertainty in measured values. Furthermore, the salt composition evolves over time due to the uptake of impurities from the atmosphere and corrosion of containment vessels. More significantly, fission products will accumulate during operation that change the salt compositions and property values. MSR developers need to understand how this uncertainty in the basic property data of the fuel will impact modeling predictions for normal reactor operation as well was in transient scenarios that will impact the safety basis. The calculations and analyses in this report address the impact of uncertainty in measured property values under steady-state conditions through a generalized parametric study. The pooled uncertainty from contributions by a number of factors were considered and quantified, including varying composition due to impurities and fission products, imprecision in the measured values, and uncontrolled aspects of the measurement. In this way, we can begin to gain an understanding of the magnitude of the impact uncertainty will have in modeling MSR systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rose, Melissa A., Creasman, Sarah. 2022-07-20. Report on Data Quality Required for Modeling an MSR. https://doi.org/10.2172/1880780

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases