Evaluation of low cost/high temperature fiber and blanket insulation
Twelve fiber materials comprising water-felted fiber cakes and blanket insulation were subjected to furnace exposures at 1000, 1200, 1400, and 1600 C for up to 500 hours to establish the time-temperature limits below which these insulation materials can withstand repeated thermal cycles without detrimental shrinkage, thermal conductivity increase, or physical changes. Test samples were inspected periodically during the exposure cycles and weight loss and dimensional shrinkage were measured. Density, fiber crystallography, and thermal conductivity were measured after exposure and properties were compared with those of unexposed controls.