Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Analyzing Water's Optical Absorption

A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.

Source record↗

Safety and Quality Training Simulator

A portable system of electromechanical and electronic hardware and documentation has been developed as an automated means of instructing technicians in matters of safety and quality. The system enables elimination of most of the administrative tasks associated with traditional training. Customized, performance-based, hands-on training with integral testing is substituted for the traditional instructional approach of passive attendance in class followed by written examination.

Scobby, Pete T.↗

Improved Low-Temperature Performance of Li-Ion Cells Using New Electrolytes

As part of the continuing efforts to develop advanced electrolytes to improve the performance of lithium-ion cells, especially at low temperatures, a number of electrolyte formulations have been developed that result in improved low-temperature performance (down to 60 C) of 26650 A123Systems commercial lithium-ion cells. The cell type/design, in which the new technology has been demonstrated, has found wide application in the commercial sector (i.e., these cells are currently being used in commercial portable power tools). In addition, the technology is actively being considered for hybrid electric vehicle (HEV) and electric vehicle (EV) applications. In current work, a number of low-temperature electrolytes have been developed based on advances involving lithium hexafluorophosphate-based solutions in carbonate and carbonate + ester solvent blends, which have been further optimized in the context of the technology and targeted applications. The approaches employed, which include the use of ternary mixtures of carbonates, the use of ester co-solvents [e.g., methyl butyrate (MB)], and optimized lithium salt concentrations (e.g., LiPF6), were compared with the commercial baseline electrolyte, as well as an electrolyte being actively considered for DoE HEV applications and previously developed by a commercial enterprise, namely LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC)(30:70%).

Smart, Marshall C.↗

Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening

Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Titanium Niobium Oxide: From Discovery to Application in Fast-Charging Lithium-Ion Batteries

Lithium-ion batteries are essential for portable technology and are now poised to disrupt a century of combustion-based transportation. The electrification revolution could eliminate our reliance on fossil fuels and enable a clean energy future; advanced batteries would facilitate this transition. However, owing to the demanding performance, cost, and safety requirements, it is challenging to translate new materials from laboratory prototypes to industrial-scale products. This Perspective describes that journey for a new lithium-ion battery anode material, TiNb 2 O 7 (TNO). TNO is intended as an alternative to graphite or Li 4 Ti 5 O 12 with better rate and safety characteristics than the former and higher energy density than the latter. The high capacity of TNO stems from the multielectron redox of Nb 5+ to Nb 3+ , its operating voltage window well above the Li + /Li reduction potential prevents lithium dendrite formation, and its open crystal structure leads to high-power performance. Nevertheless, the creation of a practical TNO anode was nonlinear and nontrivial. Its history is built on 30 years of fundamental science that preceded its application as a battery anode, and its battery development included a nearly 30-year gap. The insights and lessons contained in this Perspective, many of them acquired firsthand, serve two purposes: (i) to unite the disparate studies of TiNb 2 O 7 into a coherent modern understanding relevant to its application as a battery material and (ii) to highlight briefly some of the challenges faced when scaling up a new material that affect TiNb 2 O 7 as well as new electrode candidates more generally.

25 ENERGY STORAGE↗

Translating a Material Discovery into a Commercial Product in the Modern Lithium-ion Battery Market

Lithium-ion batteries are essential for portable technology and are now poised to disrupt a century of combustion-based transportation. The electrification revolution could eliminate our reliance on fossil fuels and enable a clean energy future; advanced batteries would facilitate this transition. However, owing to the demanding performance, cost, and safety requirements, it is challenging to translate new materials from laboratory prototypes to commercial products. This Perspective describes that journey toward commercialization for a new lithium-ion battery anode material, TiNb2O7 (TNO). TNO is intended as an alternative to graphite or Li4Ti5O12 with better rate and safety characteristics than the former, and higher energy density than the latter. The high capacity of TNO stems from multielectron redox of Nb5+ to Nb3+, its operating voltage window well above Li+/Li reduction potential prevents lithium dendrite formation, and its open crystal structure leads to high-power performance. Nevertheless, the creation of a practical TNO anode was non-linear and non-trivial. Its history is built on 30 years on fundamental science that preceded its application as a battery, and its battery development included a nearly 30-year gap. The insights and lessons 2 contained in this Perspective, many of them acquired firsthand, serve two purposes: (i) to unite the disparate studies of TiNb2O7 into a coherent modern understanding relevant to its application as a battery material and (ii) to highlight some of the considerations of commercializing a new material that affect TiNb2O7 as well as new electrode candidates more generally.

Griffith, Kent J.↗

Operation of Layered LiCoO 2 to Higher Voltages with a Localized Saturated Electrolyte

The commercialization of lithium-ion batteries started with the layered LiCoO 2 (LCO) cathode for portable electronics, but only 50% of its theoretical capacity can be used in practical cells due to detrimental surface and bulk degradations when charged to high voltages. Here we demonstrate here that the stability of electrolyte plays a critical role in the performance of LCO at high voltages by employing a localized saturated electrolyte (LSE). With a cutoff voltage of 4.5 V, LCO achieves an initial 1C discharge capacity of 176 mA h g -1 and a capacity retention of 80% over 230 cycles. Even with a cutoff voltage of 4.6 V, LCO with 2% aluminum doping displays an initial discharge capacity of 189 mA h g -1 at 1C rate with 80% capacity retention over 137 cycles. With extensive analytical characterization, we show that the improved cycling stability stems from a suppression of the O3 to H1-3 phase transition as well as a robust inorganic-rich cathode-electrolyte interphase (CEI) facilitated by the LSE. This work highlights the importance of protecting the surface as well as the bulk with appropriate electrolytes for the high-voltage, higher-energy-density operation of LCO.

25 ENERGY STORAGE↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface Structure of Reacting Solid Ramjet Fuels

Solid fuel ramjets are a developing technology that will enable extended range for supersonic vehicles. The simplicity of the system in terms of moving parts results in the performance being dictated by the solid fuel combustion processes. The physics near the surface, particularly in the fuel-rich recirculation zone, are challenging to resolve due to flow opacity. Here, regression rate measurements of hydroxyl-terminated polybutadiene from a miniature, portable slab burner are reported. Mass-averaged regression rates agree with correlations from the literature, suggesting that the proper physics in the burner are captured. Synchrotron-based phase-contrast imaging is used to quantify local surface features, including a multiphase froth layer, molten polymer transport, and local regression rate measurements in the recirculation zone. Regression rates near the inlet are less than the mass-averaged values, whereas near the reattachment point the local value exceeds the mass-averaged values. Further, the observed froth layer is as large as 2 mm near the inlet and decreases to sub-millimeter thicknesses near the reattachment point. An analytical heat transfer model is used to quantify the influence of the surface froth layer on the regression rates. Results indicate that the froth layer has an insulating effect and will reduce the local regression rate.

33 ADVANCED PROPULSION SYSTEMS↗

SPRUCE Photosynthesis and Respiration of Picea mariana and Larix laricina in SPRUCE Experimental Plots, 2016-2017

This dataset contains empirical physiological, morphological, and chemical data collected on two dominant conifer species, Picea mariana and Larix laricina, between May 2016 and August 2017 at the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. Analyses assessed the response of conifers to whole-ecosystem warming and elevated atmospheric carbon dioxide (CO2) concentrations. Measurements include light-saturated net photosynthesis and dark respiration at ambient atmospheric carbon dioxide (CO2) concentration (2016), CO2 response curves of light-saturated net photosynthesis (2017), leaf morphology (leaf mass per unit leaf area) and nitrogen content (on both mass and area basis). Leaf photosynthesis and respiration were measured with portable photosynthesis systems (LI6400XT, LI6800, LI-COR Biosciences, USA). In 2016, photosynthesis and respiration were measured at a common temperature of 25 ˚C to assess thermal acclimation, and at growth temperatures (for each of the five treatment temperatures) to assess field performance. In 2017, CO2 response curves of net photosynthesis (so-called A-Ci curves) were conducted at different leaf temperatures (15, 25, 32.5, 40 and 45 ˚C) for assessment of biochemical parameters and their temperature sensitivity. In addition, dark respiration measurements at different leaf temperatures (10, 15, 20, 25, 30, 35, 40, and 45 ºC) were also taken. This dataset contains one data file in comma-separate values (*.csv) and Microsoft Excel (*.xlsx) format. Additional metadata are provided: a data dictionary and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Detection of alteration associated with a porphyry copper deposit in southern Arizona

Computer processing of Landsat MSS data was performed using contrast stretching and band-to-band ratioing. A false color ratio composite picture showed color anomalies which coincided with known areas of alteration on and about Red Mountain. A helicopter survey of the study area was undertaken using a portable field reflectance spectrometer. One hundred fifty-six spectra were obtained in the 0.4 to 2.5 micrometer wavelength region. The spectra were digitized, and contour maps for 24 wavelength intervals were produced; no spectral anomalies were evident for the known altered areas. A contour map produced from the 1.6 and 2.2 micrometer ratio generally delineated the alteration areas. The 1.3, 1.6, and 2.2 micrometer wavelength data were canonically transformed using a transformation empirically derived from discriminant function analysis of altered and unaltered materials for the Goldfield, Nevada region, and a contour map was produced for the first canonical variable. The known areas of alteration were clearly defined on the contour map.

Abrams, M. J.↗

Data-Driven Software Framework for Web-Based ISS Telescience

Software that enables authorized users to monitor and control scientific payloads aboard the International Space Station (ISS) from diverse terrestrial locations equipped with Internet connections is undergoing development. This software reflects a data-driven approach to distributed operations. A Web-based software framework leverages prior developments in Java and Extensible Markup Language (XML) to create portable code and portable data, to which one can gain access via Web-browser software on almost any common computer. Open-source software is used extensively to minimize cost; the framework also accommodates enterprise-class server software to satisfy needs for high performance and security. To accommodate the diversity of ISS experiments and users, the framework emphasizes openness and extensibility. Users can take advantage of available viewer software to create their own client programs according to their particular preferences, and can upload these programs for custom processing of data, generation of views, and planning of experiments. The same software system, possibly augmented with a subset of data and additional software tools, could be used for public outreach by enabling public users to replay telescience experiments, conduct their experiments with simulated payloads, and create their own client programs and other custom software.

Tso, Kam S.↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Assessment of a Novel Touchless Interface for Intraprocedural Imaging Review

Purpose: To examine the feasibility of a novel technology platform that enables real-time touchless interaction with radiology images in both a simulated and an actual clinical setting. Materials and Methods: This platform offers three different modes for image interaction. The gesture recognition mode uses a depth camera to detect the user’s hand gestures which are translated to image manipulation commands. The light projection mode uses the same camera to detect finger point-and-tap movements above the icons which are projected on a surface to activate the commands. The capacitive sensing mode is enabled by a handheld, portable device, over which finger movements are detected by capacitive sensors to control the image review. Following initial feedback, light projection and capacitive sensing modes were selected for further testing by comparing with the conventional mode of image interaction in time trials for performing a series of standardized image manipulation tasks. Finally, the usability of the technology platform was examined in actual clinical procedures. Results: The light projection and the capacitive sensing modes were evaluated in the time trials and exhibited 60% and 71% reduction in time, respectively, relative to the control mode (p < 0.001). Clinical feasibility for this platform was demonstrated in three actual interventional radiology cases. Conclusion: Accessing, navigating, and extracting relevant information from patient images intraprocedurally are cumbersome and time-consuming tasks that affect safety, efficiency, and decision-making during image-guided procedures. This study demonstrated that the novel technology addressed this issue by allowing touchless interaction with these images in the sterile field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a field-deployable qPCR assay for real-time pest monitoring in algal cultivation systems

Outdoor cultivation is commonly used to produce algal biomass for a variety of bioproducts including food, feed, fuel, pharmaceuticals, and nutraceuticals. Outdoor cultivation ponds are highly susceptible to pest pressures that may lead to periods of low productivity or even entire loss of the algal crop. Consequently, there is a need for rapid, real-time tracking of pests for early intervention to mitigate crop loss. In this work, we describe the development of a field deployable, low-cost qPCR assay for detecting both known and novel pests of a farmed eukaryotic alga species, Nannochloropsis sp. We performed a proximity guided metagenome deconvolution approach (ProxiMeta™) to discover novel pests that temporally correspond to periods of reduced pond productivity. This approach provided high-quality metagenome assemblies that were used to design qPCR probes to detect specific pests of interest. The portable qPCR assay, designed to be deployed at remote field locations, enables low-cost surveillance with a rapid (2 h) turn-around time. Frequent sampling allows for early detection and prompts intervention strategies to remedy infected ponds to minimize crop loss. The qPCR assay was used to successfully detect a known predatory bacterium within the order Bdellovibrionales both in the lab and at a remote field location. Furthermore, we assembled the genome of two novel, site-specific pests in the Saprospiraceae family and successfully designed qPCR probes that differentially detected their presence in two different pond locations. Ultimately, this assay has the potential to monitor multiple pests simultaneously and tailor targets to match likely pest infections that differ across geographical locations, helping to mitigate crop loss on a large scale.

59 BASIC BIOLOGICAL SCIENCES↗

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

36 MATERIALS SCIENCE↗

Quantitative Hydrocarbon Surface Analysis

The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

Douglas, Vonnie M.↗