Evaluation of a non-catalytic coating for metallic TPS
A commercially available ceramic coating was evaluated for application to metallic heat shields for Shuttle-type entry vehicles. Coated Inconel 617 specimens were subjected to thermal shock cycles, surface emittances were measured, and surface equilibrium temperatures were measured for coated and oxidized specimens exposed to an arc-tunnel environment. The coating adhered very well to the metal and appeared to be very non-catalytic.