Field-electron-microscopy studies of cesium layers on various refractory metals - Work function change.
Work function variation with Cs layer coverage on W, Mo, Re and Ni substrates, using field electron microscopes
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Work function variation with Cs layer coverage on W, Mo, Re and Ni substrates, using field electron microscopes
Thin foils of high purity aluminium and an Al-Al2O3 SAP type of alloy were oxidised in a specially designed hot stage specimen chamber in an electron microscope. Below 450 C, amorphous aluminium oxide formed on the foil surface and was first detectable at foil edges, holes, and pits. Islands of aluminium then nucleated in this amorphous oxide. The aluminium islands displayed either a lateral growth with eventual coalescence with other islands, or a reoxidation process which caused the islands to disappear. The aluminium island formation was determined to be related to the presence of the electron beam. A mechanism based upon electron charging due to the electron beam was proposed to explain the nucleation, growth, coalescence, disappearance, and geometry of the aluminium islands.
A method was developed for measuring nondestructively the depth of planar p-n junctions in simple devices as well as in integrated-circuit structures with the electron-beam induced current (EBIC) by scanning parallel to the junction in a scanning electron microscope (SEM). The results were found to be in good agreement with those obtained by the commonly used destructive method of lapping at an angle to the junction and staining to reveal the junction.
A number of approaches have been used to separate stained conventional histological sections from glass slides in preparation for a study with the electron microscope. However, in each reported case some problems were encountered with respect to the separation process. The present investigation is concerned with the use of the epoxy resin Quetol 651 as an embedding medium for this procedure, taking into account the simple application of heat (62-64 C) for performing the separation step. After the tissue has been removed from the glass by the considered technique, it is thin sectioned, and stained with uranyl acetate-lead citrate.
Since its development over 20 years ago, aberration correction has revolutionized the way we study materials at the atomic scale. In this paper, I outline a set of technical developments for electron microscopes that, when implemented and combined, will enable us to better understand how matter behaves.
This method describes the characterization of inert and HE materials by the Zeiss Sigma HD VP field emission Scanning Electron Microscope (SEM). The SEM uses an accelerated electron beam to generate high-magnification images of explosives and other materials. It is fitted with five detectors (SE, Inlens, STEM, VPSE, HDBSD) to enable imaging of the sample via different secondary electron signatures, angles, and energies. In addition to imaging through electron detection, the microscope is also fitted with two Oxford Instrument Energy Dispersive Spectrometer (EDS) 80 mm detectors to generate elemental constituent spectra and two-dimensional maps of the material being scanned.
Description of a new method which makes it possible to reduce drastically the resolution-limiting influence of chromatic aberration, and thus to obtain high-quality images, by selecting the image-forming electrons that have passed through a small annular zone of an objective lens. In addition, the manufacture of special objective-lens aperture diaphragms that are needed for this method is also described.
It has been observed that wurtzite II–VI semiconducting nanobelts transform into single-crystal, periodically branched nanostructures upon heating. The mechanism of this novel transformation has been elucidated by heating II–VI nanobelts in an environmental transmission electron microscope (ETEM) in oxidizing, reducing and inert atmospheres while observing their structural changes with high spatial resolution. The interplay of surface reconstruction of high-energy surfaces of the wurtzite phase and environment-dependent anisotropic chemical etching of certain crystal surfaces in the branching mechanism of nanobelts has been observed. Understanding of structural and chemical transformations of materials via in situ microscopy techniques and their role in designing new nanostructured materials is discussed.
Single-crystalline thin films of copper were oxidized at an isothermal temperature of 425 C and at an oxygen partial pressure of .005 Torr in situ in a high-resolution electron microscope. The specimens were prepared by epitaxial vapor deposition onto polished 100 and 110 faces of rocksalt and mounted in a hot stage inside an ultra-high-vacuum specimen chamber of the microscope. Large amounts of sulfur, carbon, and oxygen were detected by Auger electron spectroscopy on the surface of the as-received films and were removed in situ by ion-sputter etching immediately prior to the oxidation. The nucleation and growth characteristics of Cu2O on Cu were studied. Results show that neither stacking faults nor dislocations are associated with the Cu2O nucleation sites. The growth of Cu2O nuclei is linear with time. The experimental findings, including results from oxygen dissolution experiments and from repetitive oxidation-reduction-oxidation sequences, fit well into the framework of an oxidation process involving (a) the formation of a surface-charge layer, (b) oxygen saturation in the metal and (c) nucleation, followed by surface diffusion of oxygen and bulk diffusion of copper for lateral and vertical oxide growth, respectively.
The resolution of available low-voltage SEM (LVSEM) models used in the characterization of interplanetary dust particles (IDPs) is limited by a number of factors including energy spread in the electron source, beam brightness, scanning electron detector geometry, and various lens aberrations. This paper describes an improved model of LVSEM which offers an increased resolution at low voltage. The improvements include a cold cathode FE source which has an extremely low inherent energy spread and high brightness, a second condenser lens to converge the beam and maintain an optimum aperture half-angle, and a detector optimized for low-voltage scanning-electron collection. To reduce lens aberrations, the specimen is immersed in the objective lens field. The features of several IDP samples observed using the images obtained with this LVSEM model are described.
Chemical bonds fundamentally determine molecular properties and are prevalently characterized by various spectroscopic means such as infrared and Raman spectroscopies. However, the spatial resolution of these conventional approaches is insufficient to reveal nanoscale features. Recently, monochromated electron energy-loss spectroscopy (EELS) in the transmission electron microscope achieved a groundbreaking energy resolution of a few millielectronvolts and enabled direct observation of molecular vibrational spectrum with unmatched spatial resolution. Vibrational EELS is widely applicable to both organic and inorganic matter in the solid state or liquid phase. In this study, we introduce recent advancements and key concepts of this method, compare with other spectroscopic techniques, and discuss future developments for potential applications in research fields centered on catalysts, polymers, and live cells.
Particulate samples of experimentally shocked olivine, enstatite, and apatite and their unshocked equivalents were thinned by ion bombardment and examined by transmission methods in a conventional (100 kV) electron microscope. Enstatite shock-loaded at a peak pressure of 250 kb was partly transformed to relatively dense inverse defect spinel. Magnesian olivine shocked at a peak pressure of 200 kb shows intense lattice deformation. Magnesian olivine shock-loaded at a peak pressure of 400 kb was recrystallized to very fine polycrystalline aggregates. Apatite shock-loaded at a peak pressure of 250 kb shows planar deformation elements and shock-induced imperfections.
A characterization of the microstructural features of Santa Catharina (SC) from the millimeter to submicron scale is presented. The same specimen was examined using an optical microscope, a scanning electron microscope, an electron probe microanalyzer, and an analytical electron microscope. Findings include the fact that SC metal nodules may have different bulk Ni values, leading to different microstructures upon cooling; that SC USNM 6293 is the less corroded sample, as tetrataenite exists as less than 10 nm ordered domains throughout the entire fcc matrix (it is noted that this structure is the same as that of the Twin City meteorite and identical to clear taenite II in the retained taenite regions of the octahedrites); that SC USNM 3043 has a more complicated microstructure due to corrosion; and that the low Ni phase of the cloudy zone was selectively corroded in some areas and formed the dark regions, indicating that the SC meteorite corrosion process was electrochemical in nature and may involve Cl-containing akaganeite.
Charged particle radiography with 800 MeV protons has been used for decades at LANL and developed around the world to study dynamic material properties. Recently, charged particle radiography has been demonstrated with the use of high-energy electrons. Because of the difference in the mass of the electron compared to the mass of the proton, the radiographic processes are substantially different and well suited to the study of fast dynamic processes in relatively thin systems. This presentation will show the layout required for such measurements, along with data collected from this recent demonstration performed with 14 GeV electrons generated at the SLAC National Accelerator Laboratory. The radiographic performance for flash measurements will be presented, along with the limitations of this measurement technique.
This particular project was completed in collaboration with the metallurgical diagnostics facility. The objective of this research had four major components. First, we required training in the operation of the environmental scanning electron microscope (ESEM) for imaging of selected materials including biological specimens. The types of materials range from cyanobacteria and diatoms to cloth, metals, sand, composites and other materials. Second, to obtain training in surface elemental analysis technology using energy dispersive x-ray (EDX) analysis, and in the preparation of x-ray maps of these same materials. Third, to provide training for the staff of the metallurgical diagnostics and failure analysis team in the area of image processing and image analysis technology using NIH Image software. Finally, we were to assist in the sample preparation, observing, imaging, and elemental analysis for Mr. Richard Hoover, one of NASA MSFC's solar physicists and Marshall's principal scientist for the agency-wide virtual Astrobiology Institute. These materials have been collected from various places around the world including the Fox Tunnel in Alaska, Siberia, Antarctica, ice core samples from near Lake Vostoc, thermal vents in the ocean floor, hot springs and many others. We were successful in our efforts to obtain high quality, high resolution images of various materials including selected biological ones. Surface analyses (EDX) and x-ray maps were easily prepared with this technology. We also discovered and used some applications for NIH Image software in the metallurgical diagnostics facility.
This report describes the preliminary results of an analysis of dislocation defect structures in nondeformed and deformed austenitic stainless steels – materials of light water reactor internal components. The analysis was performed using an advanced modern approach: high-resolution electron backscatter diffraction (HR-EBSD). Work was performed at Oak Ridge National Laboratory’s Low Activation Materials Development and Analysis (LAMDA) facility. The report is divided into sections describing specific aspects of the project. Section 1 describes the necessity and importance of the defect microstructure analysis and demonstrates that there are very limited data regarding dislocation and defect population at the meso-level (i.e., a grain or group of interacting grains). Section 1 also introduces the HR-EBSD approach used in this research and provides a limited background. Section 2 describes the scanning electron microscope/EBSD systems available at the LAMDA facility, materials investigated in the present work, and hardware and software requirements for the HR-EBSD analysis. Section 3 provides preliminary HR-EBSD results for nonirradiated austenitic stainless steel in contrast to and in comparison with the conventional EBSD outcome. Section 4 describes the HR-EBSD results for austenitic stainless steel irradiated in a commercial-type nuclear power plant and subjected to in-situ mechanical testing. The analysis is focused on mapping and analyzing the geometrically necessary dislocations before and after deformation at small strain levels. As expected, the results will be beneficial for performing corrosion tests, including electrochemical microscopy, which is currently being performed within the Light Water Reactor Sustainability program at the University of California–Los Angeles (Dr. G. Sant). Section 5 summarizes the work performed, presents conclusions, and discusses future activities for this research.
Here, compressive sensing (CS) is a fast-emerging approach for improving data throughput by taking advantage of the inherent compressibility of real world data—the same kind of compressibility that allows millions of users to stream full-screen video without breaking the internet. Transmission electron microscope (TEM) users regularly collect multi-GB data sets and then use aggressive data reduction strategies to draw out the tiny residual of Shannon entropy that answers the question they wanted to ask. Much of the raw-byte-count information in an acquisition is random, redundant, or irrelevant, yet its collection still represents substantial cost in terms of instrumentation bandwidth and sample damage.
A number of ratioing methods for correcting Auger images and linescans for topographical contrast are tested using anisotropically etched silicon substrates covered with Au or Ag. Thirteen well-defined angles of incidence are present on each polyhedron produced on the Si by this etching. If N1 electrons are counted at the energy of an Auger peak and N2 are counted in the background above the peak, then N1, N1 - N2, (N1 - N2)/(N1 + N2) are measured and compared as methods of eliminating topographical contrast. The latter method gives the best compensation but can be further improved by using a measurement of the sample absorption current. Various other improvements are discussed.