Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “implosion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Demonstration of Ignition Radiation Temperatures in Indirect-Drive Inertial Confinement Fusion Hohlraums

We demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.2 MJ delivered by 192 ultraviolet laser beams on the National Ignition Facility. Laser backscatter measurements show that these hohlraums absorb 87% to 91% of the incident laser power resulting in peak radiation temperatures of T{sub RAD}=300 eV and a symmetric implosion to a 100 {mu}m diameter hot core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the Differential Cross Sections for the Elastic n-{sup 3}H and n-{sup 2}H Scattering at 14.1 MeV by Using an Inertial Confinement Fusion Facility

For the first time the differential cross section for the elastic neutron-triton (n-{sup 3}H) and neutron-deuteron (n-{sup 2}H) scattering at 14.1 MeV has been measured by using an inertial confinement fusion facility. In these experiments, which were carried out by simultaneously measuring elastically scattered {sup 3}H and {sup 2}H ions from a deuterium-tritium gas-filled inertial confinement fusion capsule implosion, the differential cross section for the elastic n-{sup 3}H scattering was obtained with significantly higher accuracy than achieved in previous accelerator experiments. The results compare well with calculations that combine the resonating-group method with an ab initio no-core shell model, which demonstrate that recent advances in ab initio theory can provide an accurate description of light-ion reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sharpening of the front of the current through a cylindrical foil liner

Results are presented from experiments on the electromagnetic implosion of aluminum foil liners at the MIG generator with a current rise time of ≈80 ns. Plasma with a density of 10{sup 17} cm{sup –3} was preliminarily injected into the liner region by using a set of radial plasma guns. The Lorentz force J × B causes plasma acceleration in the radial direction. Since the magnetic field pressure is inversely proportional to the radius squared, the plasma displacement is maximum near the liner surface. As a result, plasma motion becomes two-dimensional, a gap appears between the plasma and the liner, and the generator current is switched over to the liner. The plasma velocity at the liner surface is close to the local Alfvén velocity, while the time during which the current is switched over to the liner is nearly equal to the ratio of the liner length to the Alfvén velocity. The proposed scheme allows one to decrease the rise time of the current through the liner to several nano-seconds and, as a result, to reduce the initial liner radius and improve the stability of liner implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Letter: Meyerhofer

This letter confirms that the Laboratory for Laser Energetics (LLE) was an important part of the FY10 NIF Polar Drive Exploding Pusher experiments on the National Ignition Facility (NIF). These experiments were designed by LLE to produce requested neutron yields to calibrate and qualify nuclear diagnostics. LLE built a deuterium-tritium filling system for the glass shells and provided them to LLNL for mounting. In FY10, four exploding pusher implosions were performed with measured neutron yields within a factor of two of requested and ion temperatures within 20% of requested. These implosions are proving to be an ideal platform for commissioning the nuclear diagnostic suite on the NIF and are achieving all of the objectives planned for this campaign.

42 ENGINEERING↗

Target Diagnostics Supports NIF's Path to Ignition

The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

42 ENGINEERING↗

Deep Dive Topic: Choosing between ablators

Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Magneto Rayleigh Taylor Instability

Reported herein is a comprehensive study of magneto-Rayleigh-Taylor instability conducted at the University of Michigan, using a one mega-ampere linear transformer driver on a cylindrical thin foil. It is a combined theoretical and experimental effort, on both magnetized and nonmagnetized liners, unseeded and seeded with a helical perturbation, and for a thin foil that is stationary, imploding or exploding. Also studied is the electrothermal instability, thought to be the seed for magneto-Rayleigh-Taylor instability. These subjects are important to magnetized liner inertial fusion (MagLIF). We interpret the helical features usually observed in a magnetized cylindrical liner as a manifestation of a discrete eigenmode, from implosion to stagnation. We discover that the observed pitch angle (phi) of the helix follows the simple relation, phi = m/kR, for both MagLIF experiments at the Sandia National Laboratories, and for our experiments, where m is the azimuthal mode number, k is the axial mode number, and R is the radius of the helical feature. This discrete mode persists from implosion to explosion, even through the highly nonlinear stage where the axial perturbations clump together. When the latter occurs, we propose a simultaneous decrease of mode numbers, from (m, k) to (m/2, k/2), kinematically. We show, both theoretically and experimentally, that higher m modes are excited with higher axial magnetic field. We find that seeding is far more important than the intrinsic instability of a magnetized liner. On the electro-thermal instability, we discover that refractory metals with a low ratio of critical temperature to melting temperature (i.e. tantalum) are very robust against electrothermal instability. We perform the first experiments that show the transition of electrothermal instability from the striation to filamentation mode. We experimentally confirm the importance of surface defects in the development of the electrothermal instability. We develop and publish a fabrication method for ultra-thin metallic liners. Three (3) graduate students completed their PhD theses with the support of this grant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Impurity Atoms on Thermonuclear Yield

The presence of impurity atoms in an inertial confinement fusion (ICF) implosion can greatly affect the burning of the thermonuclear fuel. This is a serious concern for attaining ignition as high atomic number atoms, such as carbon, can mix into the hot spot and reach the deuterium–tritium (DT) fuel, absorb energy from the implosion, and radiate away that energy. The temperature of the DT fuel drops and reduces the reactivity of the fuel resulting in lower thermonuclear yield. Fuel impurities can also be a useful diagnostic as when higher-Z atoms, such as Ar, Kr, and Xe, are purposefully mixed into the fuel. From the spectra emitted by these atoms, the temperature and density of the fuel can be deduced. The long history of using such tracer atoms by the national ICF program shows the great advances in experimental technique, diagnostic instruments, and atomic-physics modeling over the past 50 years. A particular set of experiments, the “High-Z” campaign, is reviewed in depth as this was the most systematic study of tracer element composition and quantity ever reported. Difficulties in interpreting the results of those experiments due to the limited code capabilities at that time are discussed. A main concern for the High-Z campaign was the then current state of non-Local Thermodynamic Equilibrium (nLTE) atomic physics models. The present state of nLTE modeling and its implementation in Los Alamos’s multi-physics codes is discussed in this report. To further the understanding of the complex interaction of high-Z atoms in the gas, a survey of relevant existing experimental platforms at the National Ignition Facility (NIF) and the Omega Laser Facility are presented along with the current state of pertinent diagnostics at NIF and Omega. This review concludes with a discussion of the trade-off available between temperature and volume of the imploded ICF capsule with the goal of maximizing the total yield.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Low Fuel Convergence Path to Inertial Confinement Fusion on the National Ignition Facility (Final Report)

After a decade of trying, the grand challenge problem of achieving hot spot ignition on NIF has not been achieved using indirect-drive of a high-convergence single shell capsule inside a hohlraum. Here, the alternate concept of obtaining volume-like ignition of liquid DT fuel via multi-shell implosion using laser polar direct drive (PDD) on NIF was assessed through theoretical analysis, computer simulation, fabrication development and implosion experiments on both the Laboratory for Laser Energetics’ (LLE) Omega laser and the National Ignition Facility (NIF). This research has shown that multi-shell ignition has merit and should be further advanced by the National ICF Program to determine its ultimate limitations for achieving ignition on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLE Review 121 (September-December 2009)

This issue has the following articles: (1) Demonstration of the Highest Deuterium-Tritium Areal Density Using Triple-Picket Cryogenic Designs on OMEGA; (2) High-Precision Measurements of the Equation of State of Hydrocarbons at 1 to 10 Mbar Using Laser-Driven Shock Waves; (3) A Generalized Measurable Ignition Condition for Inertial Confinement Fusion (4) In-Situ Detection and Analysis of Laser-Induced Damage on a 1.5-m Multilayer-Dielectric Grating Compressor for High-Energy, Petawatt-Class Laser Systems; (5) Probing High-Areal-Density ({rho}R) Cryogenic-DT Implosions Using Down-Scattered Neutron Spectra Measured by the Magnetic Recoil Spectrometer; (6) Strong-Coupling and Degeneracy Effects in Inertial Confinement Fusion Implosions; and (7) Neutron-Induced Nucleation Inside Bubble Chambers Using Freon 115 as the Active Medium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of backlighting sources for a Compton Radiography diagnostic of Inertial Confinement Fusion targets

An important diagnostic tool for inertial confinement fusion is time-resolved imaging of the dense cold fuel surrounding the hot spot. Here we report on the source and diagnostic development of hard x-ray radiography and on the first radiographs of direct drive implosions obtained at photon energies up to about 100keV, where the Compton effect is the dominant contributor to the shell opacity. The radiographs of direct drive, plastic shell implosions obtained at the OMEGA laser facility have a spatial resolution of {approx}10um and a temporal resolution of {approx}10ps. This novel Compton Radiography is an invaluable diagnostic tool for Inertial Confinement Fusion targets, and will be integrated at the National Ignition Facility (NIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling gated neutron images of THD capsules

Time gating a neutron detector 28m from a NIF implosion can produce images at different energies. The brighter image near 14 MeV reflects the size and symmetry of the capsule 'hot spot'. Scattered neutrons, {approx}9.5-13 MeV, reflect the size and symmetry of colder, denser fuel, but with only {approx}1-7% of the neutrons. The gated detector records both the scattered neutron image, and, to a good approximation, an attenuated copy of the primary image left by scintillator decay. By modeling the imaging system the energy band for the scattered neutron image (10-12 MeV) can be chosen, trading off the decayed primary image and the decrease of scattered image brightness with energy. Modeling light decay from EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A leads to a preference from BCF99-55 for the first NIF detector, but DPAC 30 and Liquid A would be preferred if incorporated into a system. Measurement of the delayed light from the NIF scintillator using implosions at the Omega laser shows BCF99-55 to be a good choice for down-scattered imaging at 28m.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the National Ignition Facility Ignition Hohlraum Energetics Experiments

A series of forty experiments on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)] to study energy balance and implosion symmetry in reduced- and full-scale ignition hohlraums was shot at energies up to 1.3 MJ. This paper reports the findings of the analysis of the ensemble of experimental data obtained that has produced an improved model for simulating ignition hohlraums. Last year the first observation in a NIF hohlraum of energy transfer between cones of beams as a function of wavelength shift between those cones was reported [P. Michel, et al, Phys of Plasmas, 17, 056305, (2010)]. Detailed analysis of hohlraum wall emission as measured through the laser entrance hole (LEH) has allowed the amount of energy transferred versus wavelength shift to be quantified. The change in outer beam brightness is found to be quantitatively consistent with LASNEX [G. B. Zimmerman and W. L. Kruer, Comments Plasma Phys. Control. Fusion 2, 51 (1975)] simulations using the predicted energy transfer when possible saturation of the plasma wave mediating the transfer is included. The effect of the predicted energy transfer on implosion symmetry is also found to be in good agreement with gated x-ray framing camera images. Hohlraum energy balance, as measured by x-ray power escaping the LEH, is quantitatively consistent with revised estimates of backscatter and incident laser energy combined with a more rigorous non-local-thermodynamic-equilibrium atomic physics model with greater emissivity than the simpler average-atom model used in the original design of NIF targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design calculations for NIF convergent ablator experiments.

Design calculations for NIF convergent ablator experiments will be described. The convergent ablator experiments measure the implosion trajectory, velocity, and ablation rate of an x-ray driven capsule and are a important component of the U. S. National Ignition Campaign at NIF. The design calculations are post-processed to provide simulations of the key diagnostics: (1) Dante measurements of hohlraum x-ray flux and spectrum, (2) streaked radiographs of the imploding ablator shell, (3) wedge range filter measurements of D-He3 proton output spectra, and (4) GXD measurements of the imploded core. The simulated diagnostics will be compared to the experimental measurements to provide an assessment of the accuracy of the design code predictions of hohlraum radiation temperature, capsule ablation rate, implosion velocity, shock flash areal density, and x-ray bang time. Post-shot versions of the design calculations are used to enhance the understanding of the experimental measurements and will assist in choosing parameters for subsequent shots and the path towards optimal ignition capsule tuning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DEVELOPMENT OF SOLID COLLECTION DIAGNOSTICS ON NIF THROUGH BLAST SHIELD ANALYSIS

Radiochemical analysis of post-shot debris inside the National Ignition Facility (NIF) target chamber can help determine various diagnostic parameters associated with the implosion efficiency of the fusion capsule. This capability is limited by the amount of target isotope that can be loaded inside the capsule ablator without affecting performance and the collection efficiency of the capsule debris after implosion. Prior to designing a collection system, the chemical nature and distribution of the debris inside the chamber must be determined and analysis methods developed. The focus of our current work has been on determining the elemental composition and distribution of debris on various blast shields and witness plates that were exposed to the chamber during ignition shots that occurred in 2009. These passive collection plates were used to develop both non-destructive and chemical analysis techniques to determine debris composition and melt depth at various shot energy profiles. A summary of these data will be presented along with our current strategy for the 2011 campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

42 ENGINEERING↗

South pole bang-time diagnostic on the National Ignition Facility

The south pole bang-time (SPBT) diagnostic views National Ignition Facility (NIF) implosions through the lower hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect drive implosions. Five chemical-vapor-deposition (CVD) diamond photoconductive detectors (PCD's) with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength-selecting highly oriented pyrolytic graphite (HOPG) crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in-situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray 'yield' (mJ/sr/keV at 11 keV) is determined from the total area under the peak.

36 MATERIALS SCIENCE↗

SIMULATION OF RADIATION BACKGROUNDS ASSOCIATED WITH NUCLEAR DIAGNOSTICS IN THE NATIONAL IGNITION FACILITY

Experiments resulting in a significant neutron yield are scheduled to start in 2010 at the National Ignition Facility (NIF). Several experiments utilizing Tritium-Hydrogen-Deuterium (THD) and Deuterium-Tritium (DT) targets are scheduled as part of the National Ignition Campaign (NIC). A wide range of diagnostics will be used to measure several parameters of implosion such as the core and fuel shape, temperatures and densities, and neutron yield. Accurate evaluations of the neutron and gamma backgrounds are important for several diagnostics, such as the High Energy X-ray Imager (HEXRI) and Neutron-Time-Of-Flight (nTOF). Several sources of neutron and gamma backgrounds will impact the accuracy of the diagnostics measurements. Fusion neutrons generated by fuel burn and secondary neutrons resulting from the fusion neutrons interaction with structures present inside and outside the Target Chamber (TC) contribute to the neutron background. In the meantime, X-rays emitted from the implosion, X-rays resulting from Laser Plasma Interaction (LPI) of NIF beams with the hohlraum, and gamma-rays induced by neutron interactions with different structures inside and outside the TC contribute to the gamma background. A detailed model has been developed of the NIF facility and all structures inside the TC. Several Monte-Carlo simulations were performed to identify the expected signal-to- background ratios at several potential locations for the HEXRI and nTOF diagnostics. Gamma backgrounds associated with HEXRI were significantly reduced by using a tungsten collimator. The collimator resulted in the reduction of the gamma background at the HEXRI scintillator by more than an order of magnitude during the first 40 ns following a THD shot. The nTOF20 detectors inside the Neutron Spectrometry room are exposed to low levels of neutron and gamma background during yield shots.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗