DOE OSTI · 1241944
Deep Dive Topic: Choosing between ablators
Abstract
Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Hurricane, O. A., Thomas, C., Olson, R.. 2015-07-14. Deep Dive Topic: Choosing between ablators. https://doi.org/10.2172/1241944
Cite the original work for its findings. Save a collection to share your selection of sources.