Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Laser Surface Preparation of Epoxy Composites for Secondary Bonding: Optimization of Ablation Depth

Surface preparation has been identified as one of the most critical aspects of attaining predictable and reliable adhesive bonds. Energetic processes such as laser ablation or plasma treatment are amenable to automation and are easily monitored and adjusted for controlled surface preparation. A laser ablation process was developed to accurately remove a targeted depth of resin, approximately 0.1 to 20 micrometers, from a carbon fiber reinforced epoxy composite surface while simultaneously changing surface chemistry and creating micro-roughness. This work demonstrates the application of this process to prepare composite surfaces for bonding without exposing or damaging fibers on the surface. Composite panels were prepared in an autoclave and had a resin layer approximately 10 micrometers thick above the fiber reinforcement. These composite panels were laser surface treated using several conditions, fabricated into bonded panels and hygrothermally aged. Bond performance of aged, experimental specimens was compared with grit blast surface treated specimens using a modified double cantilever beam test that enabled accelerated saturation of the specimen with water. Comparison of bonded specimens will be used to determine how ablation depth may affect average fracture energies and failure modes.

Palmieri, Frank L.↗

Secondary Ion Mass Spectroscopy

Secondary Ion mass Spectroscopy (SIMS), as the name suggests, involves characterizing metallic and other materials trough the spectroscopic analysis of secondary ions emanating from the surface of the material to be characterized by the impact of the high energy primary ions. The primary ion source including the choice of its gun, voltage and current can be selected and used depending on the purpose of the analysis. In most instruments more than one primary ion gun is lined up to the sample stage and can be activated with selected accelerating parameters (voltage and beam intensity). The impingement of primary ions on to the sample surface generates positive, negative or neutral ions, electrons, atoms and atomic clusters. Majority of these sample fragments being neutral, could not be utilized as such fragments cannot be manipulated through the use of electromagnetic or electrostatic lenses. Secondary ions that are positively or negatively charged possess large variation in velocity, charge, and mass. These ionic fragments eventually travel through a system of several lenses in very high vacuum to reach detector/counter. Relative amounts of alloying elements or impurities in an alloy can be calculated from the counts of related ions accumulated in the detector/counter.

Panda, Binayak↗

Single Event Effects Test Report IXYS IXTA96P085T P-Channel -85V MOSFET

This study was undertaken to determine the destructive single event effect and degradation susceptibility of the IXTA96P085T P-Channel -85V MOSFET from IXYS. The device was monitored for destructive single event effects and degradation during exposure to a heavy ion beam at the Berkeley Accelerator Space Effects (BASE) Facility at the Lawrence Berkeley National Laboratory (LBNL). Gate and drain currents were measured during irradiation and a basic set of electrical characterizations was performed following each fluence exposure to assess heavy ion induced damage. The test date was April 10, 2024. This characterization is application specific.

MOSFET↗

Single Event Effects Test Report Vishay Siliconix Si7113DN P-Channel 100V MOSFET

This study was undertaken to determine the destructive single event effect and degradation susceptibility of the Si7113DN P-Channel 100V MOSFET from Vishay Siliconix. The device was monitored for destructive single event effects and degradation during exposure to a heavy ion beam at the Berkely Accelerator Space Effects (BASE) Facility at the Lawrence Berkely National Laboratory (LBNL).

MOSFET↗

Space Charge Effects for Transverse Collective Instabilities in Circular Machines

A brief historical review is presented of progressing understanding of transverse coherent instabilities of charged particles beams in circular machines when both Coulomb and wake fields are important. The paper relates to a talk given at ICFA Workshop on Mitigation of Coherent Beam Instabilities in Particle Accelerators, 23-27 September 2019 in Zermatt, Switzerland.

43 PARTICLE ACCELERATORS↗

Measurement of 3-Flavour Neutrino Oscillation Parameters in the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment consisting of two functionally identical tracking calorimeters, a Near and Far Detector, that measure neutrino interactions induced by the Fermi National Accelerator Laboratory’s NuMI beam at baselines of 1 km and 810 km, respectively. The NuMI beam can be configured to produce either a primary ν µ neutrino or $\bar{ν}$ µ anti-neutrino beam. Neutrino oscillations are observed and measured by the analysis of ν µ + $\bar{ν}$ µ disappearance and νe + $\bar{ν}$ e appearance in the beam, comparing the neutrino energy spectra in the Near and Far detectors means that neutrino oscillation parameters sin 2 θ 23 , |Δ$m^2_{32}$|, and δ CP can be constrained. This thesis presents the 2018 NOvA ν µ +$\bar{ν}$ µ disappearance, ν e +$\bar{ν}$ e appearance, and combined analyses using both neutrino and anti-neutrino data, where oscillation fits have been performed, where possible, on an event-by-event basis rather than on a bin-by-bin basis as has conventionally been used in NOvA oscillation analyses. This allows for better precision in applying both neutrino oscillation probabilities and systematic uncertainties. Furthermore, oscillation analyses for the disappearance, appearance, and combined channels are presented using an unbinned likelihood fit and compared with the equivalent binned χ 2 likelihood fit used in the standard analysis. The 14 ktonne detector equivalent beam exposures used for this thesis are 8.85 × 10 20 and 6.91 × 10 20 protons on target for neutrino and antineutrino data respectively, corresponding to 5 years of NOvA data taking. A combined ν µ + $\bar{ν}$ µ disappearance and ν e + $\bar{ν}$ e appearance fit to the Far Detector data, assuming normal mass ordering and using the event-by-event oscillation and unbinned fitting methodologies, produces oscillation parameter constraints of Δ$m^2_{32}$ = (2.50$^{+0.08}_{-0.06}$) × 10 -3 eV 2 , sin 2 θ 23 = 0.59$^{+0.02}_{-0.04}$, and δ CP = 0.72$^{+0.5}_{-0.9}$π.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototype HB650 Transportation Validation For The PIP-II Project

The PIP-II Project at Fermilab is centered around a superconducting 800 MeV proton linac to upgrade and modernize the Fermilab accelerator complex, allowing increased beam current to intensity frontier experiments such as LBNF-DUNE. PIP-II includes strong international collaborations, including the delivery of 12 cryomodules from European labs to FNAL (3 from STFC-UKRI in the UK and 9 from CEA in France). The transatlantic shipment of these completed modules is identifed as a serious risk for the project. To mitigate this risk, a rigorous and systematic process has been developed to design and validate a transport system, including specifcation, procedures, logistics, and realistic testing. This paper will detail the engineering process used to manage this effort across the collaboration and the results of the first major validation testing of the integrated shipping system prior to use with a cryomodule.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and fabrication of the waveguide Iris couplers for the Spallation Neutron Source drift tube linac

The Spallation Neutron Source (SNS) employs six cavities in the Drift Tube Linac (DTL) section to accelerate the H- ion beam to 87MeV. Each cavity is energized by a 2.5MW peak power klystron at 402.5MHz using rapid tapered waveguide iris couplers. All six original iris couplers have been in operation without replacement for over two decades. The increased RF power demands of the Proton Power Upgrade (PPU) project and operational problems, including arcing, temperature excursions, and vacuum bursts, have prompted the development of new iris coupler spares. The original iris couplers were made of GlidCop material, which is known to be mechanically strong and thermally stable, but is porous, expensive, and difficult to use in fabrication. To overcome these problems, the new spare couplers use Oxygen-Free Copper (OFC) and stainless steel (SS). This paper will discuss the mechanical, thermal and RF design, as well as challenges in the final coupler fabrication.

Lee, Sung-Woo↗

Software and Firmware-logic Design for the PIP-II Machine Protection System Mode and Configuration Control at Fermilab

The PIP-II Machine Protection System (MPS) requires a dedicated set of tools for configuration control and management of the machine modes and beam modes of the accelerator. The protection system reacts to signals from various elements of the machine according to rules established in a setup database in the form of a Look-Up-Table filtered by the program Mode Controller. This is achieved in accordance with commands from the operator and governed by the firmware logic of the MPS. This paper describes the architecture, firmware logic, and implementation of the program mode controller.

43 PARTICLE ACCELERATORS↗

EXPLORING INTERFEROMETRY DIAGNOSTICS FOR OPTICAL STOCHASTIC COOLING AT FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will advance the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling techniques in accelerators. The goal was to build and characterize a Mach-Zehnder Interferometer (MZI) in the FAST laser lab using known glass plates thickness which will allow future measurements of unknown phase change due to nonlinear amplification processes.

Teriba, Folashade↗

Theory of Beam Echoes

We develop the theory of beam echoes in circular accelerators under several different conditions. We derive detailed expressions for the echo amplitude and pulse width with nonlinear quadrupole and dipole kicks, first without and then with momentum spread. We use the theory with the linearized dipole and quadrupole kicks to solve the diffusion equation for different dependencies of the diffusion coefficient on the action. We then consider the use of multiple quadrupole kicks to increase the maximum echo amplitude. We have extended these calculations partially to the 2D case and we also have partial results for longitudinal echoes.

43 PARTICLE ACCELERATORS↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Micromachined Ion Accelerators

Proposed ion accelerators made by micromachining techniques. Advantages include small size and weight, modularity, and compatibility with integrated circuits. Used as sources of ion beams for industrial processes. Ion accelerator of this type combined with integrated electronic control and power circuitry, plus similarly miniaturized valves and other mechanisms for regulating flow of gas used to generate ions - all micromachined on single chip. Provides flexibility for tailoring characteristics of ion sources for specific applications; for example, construct array of many such devices to obtain large ion source or position multiple devices to obtain desired ion-beam pattern in processing chamber.

Brophy, John↗

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning at the Spallation Neutron Source accelerator and target

We describe the ongoing efforts to apply Machine Learning techniques to improve the performance of our accelerator and target. Specially, we are looking to minimize halo beam losses in the absence of a proper physics model, automatically detect and log anomalies in the target support systems such as cooling, and detect and prevent errant beam pulses in the linac. We also describe the infrastructure we use to acquire and stream data to the GPU cluster for training, our code development cycle, and edge computing for model inference. To minimize halo beam losses, we use a Reinforcement Learning technique tested on a virtual accelerator. The target anomaly detection is trained on archived data using incomplete physics models and is made part of the existing target reporting system. The errant beam prevention analyzes beam current and beam phase waveforms as well as accelerator configuration data to predict errant pulses. We also develop continual learning to adapt to changes in the accelerator.

Accelerator Physics↗

High-Power Targetry R&D Roadmap for High Energy Physics

Designing a reliable target is already a challenge for MW-class facilities today and has led several major accelerator facilities to operate at lower power due to target concerns. With present plans to increase beam power for next-generation accelerator facilities in the next decade, timely R&D in support of robust high-power targets is critical to secure the full physics benefits of ambitious accelerator power upgrades. The next generation of high-power targets and beam-intercepting devices (beam dumps, absorbers, collimators ) will have more complex geometries, novel materials, and new concepts that allow for use of improved high-heat-flux cooling methods. Advanced numerical simulations need to be developed to support design of reliable high-power beam targets. In parallel, development of radiation-hardened beam instrumentation is needed. Irradiation methods for high-power targets must be further developed, and new irradiation facilities are needed since only a few facilities worldwide offer beams suitable for target testing. A comprehensive R&D program must be implemented to address the many complex challenges faced by multi-MW beam intercepting devices.

Pellemoine, Frederique [Fermilab]↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Theoretical investigation of plasma wave generation by pulsed electron beams in space

Here, we report theoretical calculations of plasma wave generation in the whistler modes and in the extraordinary modes, by pulsed electron beams in a magnetized plasma. The numerical simulations of the wave generation take into account the longitudinal expansion of the electron beam due to the space charge force and the energy spread. The work presented in this article provides predictions for the wave generation performance of the beam plasma interactions experiment (Beam PIE), where pulsed electron beams were produced by a spaceborne radio frequency (RF) linear accelerator. We also theoretically explore the desirable properties of the pulsed electron beam for future space experiments, which will be the next step toward eventually demonstrating the radiation-belt remediation (RBR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗