Best Practices at the End of Photovoltaic System Performance Period

Responsible and cost-effective dissolution of photovoltaic (PV) system hardware at the end of the performance period has emerged as an important business and environmental consideration. Alternatives include extending the performance period and existing contracts for power purchase, lease, and utility interconnect; refurbishing the plant by correcting any deficiencies; repowering the plant with new PV modules and inverters; or decommissioning the plant and removing all the hardware from the site. Often key decisions are made very early in the project development and might require decommissioning by some certain date after the end of a power purchase agreement. To “abandon in place” is not an alternative acceptable to landowners and regulators, so any financial prospectus should include costs associated with decommissioning, even if those costs are deferred by extending operations, refurbishment, or repowering. Decommissioning costs are driven by regulations regarding the handling and disposal of waste, with reuse and recycling of PV modules and other components preferred as a way to reduce both costs and environmental impact. Each alternative is discussed with order-of-magnitude costs, and recommendations are provided considering site-specific details of that situation, such as estimated costs to refurbish or repower, projected revenue from continued operations, and tax considerations.

14 SOLAR ENERGY↗

Powering the Blue Economy Foundational Research & Development Topics Reliability for Marine Energy Power Systems

Ocean observing platforms are deployed across the world’s oceans to collect meteorological and oceanographic data. Current technology makes use of solar panels and battery banks to provide power to these platforms, which can be challenging at high latitudes due to lack of solar insolation and cold temperatures. Marine renewable energy (MRE) generation offers a potential improvement in consistent power generation throughout the year for this use on ocean observation buoys. This report analyzes existing reliability of high latitude coastal weather buoys and tsunami detection buoys to determine performance standards that MRE generation sources must meet to become viable power sources for these remote systems. Using measurements recorded from the U.S. National Data Buoy Center’s coastal weather buoys and tsunami detection buoys, the analysis calculated the historic data availability – or the percentage of time a measurement is recorded – to evaluate the reliability of ocean observation buoys. The results show that coastal weather buoys operate at 74% data availability and the tsunami detection systems operate at an average 72% data availability. The results describe the total reliability of the system, including many different types of failures not associated with the power system such as mooring failures or equipment failures caused by extreme weather. Power system outages may only account for a small portion of the system failures. Reliability is an important design criterion for the power system of ocean observation platforms. Future power systems that would be designed for these buoys, such as an MRE generator, need to have a minimum reliability of 72% and 74% to meet the overall performance of the weather buoys and tsunami buoys, respectively. However, power system reliability likely needs to be much higher than overall system reliability, so that power system outages do not negatively impact the overall performance of the buoy.

42 ENGINEERING↗

Flexible Boundary Design for a Chattanooga Microgrid Powered by Landfill Solar Photovoltaic and Battery Storage

Landfill based microgrids powered by renewable energy aid reliability and resiliency while promoting environmental and energy justice. This paper aims to design a flexible boundary algorithm for a proposed Chattanooga landfill microgrid with the ability to shrink or expand its boundaries based on the available power from the solar PV and battery storage. This helps to improve resiliency unlike the conventional fixed boundary microgrids. The flexible boundary algorithm determines the combination and switching status of the intellirupter ® which changes the microgrid boundaries to achieve power balance by dropping or energizing specific load sections. Finally, the microgrid with flexible boundary was simulated in MATLAB/Simulink and performed satisfactorily when tested under various scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neuromorphic Graph Algorithms: Cycle Detection, Odd Cycle Detection, and Max Flow

Neuromorphic computing is poised to become a promising computing paradigm in the post Moore’s law era due to its extremely low power usage and inherent parallelism. Spiking neural networks are the traditional use case for neuromorphic systems, and have proven to be highly effective at machine learning tasks such as control problems. More recently, neuromorphic systems have been applied outside of the arena of machine learning, primarily in the field of graph algorithms. Neuromorphic systems have been shown to perform graph algorithms faster and with lower power consumption than their traditional (GPU/CPU) counterparts, and are hence an attractive option for a co-processing unit in future high performance computing systems, where graph algorithms play a critical role. In this paper, we present a neuromorphic implementation of cycle detection, odd cycle detection, and the Ford-Fulkerson max-flow algorithm. We further evaluate the performance of these implementations using the NEST neuromorphic simulator by using spike counts and simulation time as proxies for energy consumption and run time. In addition to gains inherent in neuromorphic systems, we show that within the neuromorphic implementations early stopping criteria can be implemented to further improve performance.

Kay, Bill↗

Plasma performance and operational space without ELMs in DIII-D

A database of DIII-D plasmas without ELMs compares the operating space and plasma performance of stationary no-ELM regimes: RMP-ELM suppression, QH-mode, I-mode, EDA H-mode, L-mode, and negative triangularity L-mode (Neg-D). Here, operational space is documented in terms of engineering and physics parameters, revealing divergent constraints. Some operational space discriminants (like pedestal collisionality) are well known, while others, such as low torque & safety factor, or high power & density, are less commonly emphasized. Normalized performance (H-factor and betan) also discriminate the no-ELM regimes and favor regimes tolerant to power in DIII-D: RMP, QH, and Neg-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Packaging Designs

The primary deliverable for this project will be to construct a power electronics package utilizing an organic, electrically insulating substrate material and demonstrate superior thermal performance and greater reliability under thermal cycling, thermal aging, vibration, power cycling, and electrical high-potential evaluation over traditional packages.

ENGINEERING↗

Life Cycle Greenhouse Gas Emissions of Coal-Biomass Co-Firing Power Plants with Carbon Capture and Storage

The United States has set a target to achieve the net-zero economy by 2050. Bioenergy with Carbon Capture and Sequestration (BECCS) is one of the promising negative-emission routes in the mitigation portfolio to help meet this goal. Coal-biomass co-firing with carbon capture and storage (CCS) is a key BECCS technology to realize the carbon mitigation at fossil-fuel power plants. The mitigation potential of co-firing option is affected by numerous critical factors, such as biomass properties, co-firing level, and carbon capture rate. The objectives of the study are to characterize and estimate the life cycle greenhouse gas (GHG) emissions and performance of coal-biomass co-firing power plants with CCS, determine the breakeven co-firing level at power plants necessary to achieve net-zero life cycle emissions, and quantify the variabilities and uncertainties in life cycle emissions. The scope of the life cycle assessment includes the fuel supply, combustion-based power generation, and CO2 transport and storage. A fuel-based life cycle module is developed and embedded in the Integrated Environmental Control Model (IECM), a fossil-fuel power plant modeling tool. This study then applies the enhanced IECM to conduct the process-based life cycle assessment for an array of biomass co-firing scenarios. Deterministic analysis indicates that reaching net-zero life cycle emissions in a biomass co-firing plant without CCS deployment is challenging. Combining biomass co-firing and CCS deployment can significantly lower the overall life cycle emissions of power plants. Net-zero life cycle emissions can be achieved with a 20 wt.% co-firing level and 90% CCS when the Powder River Basin coal is co-fired with energy crops or forestry residues. However, the breakeven co-firing level for net-zero emissions depend on the selected fuel properties. Fuel supply and plant operation are the critical stages influencing the life cycle emissions of power plants with 90% CCS. Deployment of deep CCS beyond 90% CO2 capture can remarkably reduce operational emissions and the breakeven co-firing level. With 99% CCS, the breakeven co-firing rate can be reduced to 12% on average. These findings highlight the trade-offs between technical performance and environmental impact of biomass co-firing at coal-fired power plants and emphasize the role of deep CCS in achieving a net-zero emissions future.

Wu, Wanying↗

Improving Performance and Durability of Low Temperature Direct Ammonia Fuel Cells: Effect of Backpressure and Oxygen Reduction Catalysts

Low temperature direct ammonia fuel cells (DAFCs) are attractive for transportation applications. The primary obstacle to their commercial use is their low performance and poor durability. In the present work, we focus on improving DAFCs performance and durability by examining the effect of operating backpressure and oxygen reduction reaction (ORR) catalysts such as Acta 4020, Pd/C and Pt/C. DAFCs with Acta 4020 cathode can reach a peak power density of 390 mW cm -2 which is among the best reported performance, but they can be operated for a period of 11 h at 300 mA cm -2 . DAFCs with Pd/C cathode offer a moderate performance with a peak power density of 304 mW cm -2 , but has a much improved durability - a continuous operation for up to 36 h with a slow decay rate of ~1 mV h -1 at 300 mA cm -2 . In addition, the degradation pathways for DAFCs with Pd/C cathode are probed by characterizing the initial and final electrodes by XPS, suggesting that cathodic Pd dissolution occurs during the durability test.

Electrochemistry↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

Improvement in Power Output for CNT Polymer Hybrid Film and Accompanying Thermoelectric Generator: Cooperative Research and Development (CRADA CRD-15-596 Final Report)

NREL personnel will enhance International ThermoDyne's (ITD) understanding of the controlling factors for power output within a process for the manufacturing of high-performance carbon nanotube (CNT) thermoelectric generator (TEG) structure (alternative areas of p and n type semiconductor) and provide ITD with samples ('Deliverables') demonstrating these advances in power output that can used. The Deliverables will have performance characteristics outlined in Table 1, for use in ITD's PowerFelt product. The initial goals of this project are to achieve thermoelectric p and n films with power factors of at least 600uW/mK2 made through NREL's process for TEG paper manufacture with high conductivity and low thermal conductivity and eventually achieving higher performance of > 900 uW/mK2.

36 MATERIALS SCIENCE↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of fast-running eighth core nodal solution

A fast-running, eighth-core solution technique has been developed for the quick core calculations in ANC, the Westinghouse core analysis code based on the nodal expansion method, and the BEACON{sup TM} Core Monitoring System (BEACON). This technique, referred to as 'Fast Eighth' (Fast8), enables users to obtain satisfactory macroscopic core calculation results such as reactivity, axial offset and assembly power much more quickly than calculations performed in the standard full-core or quarter-core geometry. Fast8 uses three techniques: folding the radial geometry into eighth-core geometry, reducing the axial geometry into a coarse axial mesh geometry, and smearing the spacer grids into nodes on-the-fly after the first calculation in the standard geometry. These geometry adjustments in Fast8 contribute to the reduction of the number of neutronic and material nodes while maintaining the reaction rates in each node. The axial mesh condition dependency in Fast8 is investigated in a xenon transient calculation in single assembly geometry, and the Fast8 maximum axial mesh size is determined based on these results. Fast8 is then applied to the load swing calculation, and the results are compared with the reference, full-core geometry, solution. The critical boron concentration and axial offset of Fast8 show good agreement with the reference solutions, and that Fast8 is a good technique for obtaining macroscopic core calculation results in significantly shorter time. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

Annual Performance of the Second-Generation Variable-Geometry Oscillating Surge Wave Energy Converter

Recent studies in wave energy have highlighted the need for a structured innovation approach in wave energy converter (WEC) design because cost-of-energy estimates have remained high. One specific innovation being investigated by the National Renewable Energy Laboratory is WEC geometry control, which uses control surfaces in combination with an oscillating surge WEC (OSWEC) to increase device availability and power generation while limiting structural costs. This study performs the first analysis of annual performance for a novel OSWEC with geometry control to understand how the geometry control affects availability, annual power generation, and structural loadings like the power-take-off (PTO) torque or surge foundation force. Device hydrodynamic coefficients are calculated using linear potential theory for six geometry configurations. A nonideal PTO system is assumed and quadratic viscous damping losses are considered. Annual performance is evaluated and compared for three U.S. wave energy sites. The WEC geometry and PTO system are controlled on a sea-state basis to optimize for power capture while remaining under limits set on motion amplitude and structural loads. Results indicate that geometry control can increase availability up to 25 days in an average year depending on design limits, increase average power generation, and significantly reduce peak structural loads.

30 DIRECT ENERGY CONVERSION↗

Low Cost Glass-Ceramic Matrix Composite Heat Exchanger

As part of ARPA-E’s High Intensity Thermal Exchange through Materials and Manufacturing Processes (HITEMMP) program, this project sought to develop novel heat exchanger (HX) capabilities to enable efficient and power dense power generation cycles. This class of HX comes under the category of ceramic/composite materials with the higher temperature goal in the program of ≥1100 °C inlet temperature operation. The enabling capability of this effort is the use of glass-ceramic matrix composite (GCMC) material which provides the high temperature durability of a ceramic, the flaw tolerance of a composite, a significantly faster and lower cost manufacturing process than conventional matrix CMCs and very low porosity levels < 0.5%. For thin-walled HX structures and the need to minimize leakage, the low porosity differentiator is particularly important. RTRC has prior experience with this material system and in the current project advanced the component design and manufacturing methods into new territory to produce features required for effective heat exchange under high pressures. In this approach, silicon carbide fiber is fabricated into a fiber preform using various textile processes. Graphite tooling is used both during the build-up of the fiber preform (interior tooling) and after the fiber preform has been completed (exterior tooling). This tooling assembly is heated to high temperature in an environment that has been evacuated and backfilled with inert gas. A reservoir of specialty glass is present and once the desired temperature has been reached to achieve the desired glass viscosity, an actuator distributes the glass throughout the fiber preform using passageways which are part of the tooling design in a process known as glass transfer molding. After the tooling has been removed, the composite is heat treated to convert the amorphous glass to a crystalline ceramic, providing improved properties. The project was divided into three phases focusing on the following: 1) 10 kW HX design and coupon-level tube sheet fabrication, 2) 10 kW HX fabrication, 3) 50 kW HX fabrication. During Budget Period 1 (BP1), additional risks were encountered and the need for additional funds was agreed upon by ARPA-E program leadership. Due to a variety of factors, the contract modification required nominally 18 months to execute at which time the HITEMMP program was effectively concluding. Because of this and the time that would be required to perform BP2 tasks, it was decided to conclude the project at the end of BP1. During the design of the 10 kW HX, manufacturing constraints were learned and incorporated, leading to a revised configuration for the fiber preform and HX. Heat exchange and pressure drop predictions also played a role in modifying the original design concept to be a higher aspect ratio shell-and-tube HX, simplifying the manufacturing process and improving the heat exchanger performance. Good gravimetric and volumetric thermal power densities of 11.2 kW/kg and 10,200 kW/m3 for the entire HX were projected that involved thermo-structural Finite Element Analysis to determine the structural mass needed for the high operation pressures of 250 bar cold inlet and 80 bar hot inlet. Fiber preforms using textile processes were produced for multiple headered tube sheets. Additional challenges were encountered during the glass transfer molding step for which solutions were identified, but programmatics did not allow them to be implemented in BP1. While complete HX test articles were not fabricated, the benefits of this GCMC material for a variety of high temperature applications remain.

30 DIRECT ENERGY CONVERSION↗

NiGa 2 O 4 interfacial layers in NiO/Ga 2 O 3 heterojunction diodes at high temperature

NiO/Ga 2 O 3 heterojunction diodes have attracted attention for high-power applications, but their high temperature performance and reliability remain underexplored. Here, we report the time evolution of the electrical properties in the widely studied p-NiO/n-Ga 2 O 3 heterojunction diodes and formation of NiGa 2 O 4 interfacial layers at high temperatures. Results of our thermal cycling experiment show an initial leakage current increase which stabilizes after sustained thermal load, due to reactions at the NiO–Ga 2 O 3 interface. High-resolution TEM microstructure analysis of the devices after thermal cycling indicates that the NiO–Ga 2 O 3 interface forms a ternary compound at high temperatures, and thermodynamic calculations suggest the formation of the spinel NiGa 2 O 4 layer between NiO and Ga 2 O 3 . First-principles defect calculations find that NiGa 2 O 4 shows low p-type intrinsic doping and hence can serve to limit electric field crowding at the interface. Vertical NiO/ Ga 2 O 3 diodes with intentionally grown 5 nm thin spinel-type NiGa 2 O 4 interfacial layers show an excellent device ON/OFF ratio of >10 10 (± 3 V), V ON of ~1.9 V, and increased breakdown voltage of ~1.2 kV for an initial unoptimized 300 lm diameter device. These p–n heterojunction diodes are promising for high-voltage, high temperature applications.

30 DIRECT ENERGY CONVERSION↗

High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation

This report summarizes the work performed by University of California San Diego (UCSD) – Honeywell Aerospace (Honeywell) team for the U.S. Department of Energy/Advanced Research Projects Agency-Energy (DOE/ARPA-E) under Phase 1 (April 2021 – October 2023) project, Cooperative Agreement DE-AR0001347 entitled “High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation”. The main objective of this project is to develop and demonstrate an energy storage and power generation (ESPG) system operating on bio liquid natural gas (LNG) for electric aviation applications. The ESPG system concept in this project is a fuel cell, battery, and gas turbine hybrid system that incorporates an innovative solid oxide fuel cell (SOFC) technology. This SOFC technology has two main novel elements: (i) a lightweight and compact stack architecture that consists of cells and cell modules in electrical parallel and series connections (the module design) and (ii) exceptionally high performance, direct methane thin-film cells on porous substrate made by sputtering deposition process. This fuel cell has the specific power and volumetric power density suitable for electric aviation applications. Based on the current status of the SOFC technology, the Phase 1 work focused on the following activities: (i) ESPG System Modeling – to design and optimize an aircraft SOFC-based ESPG system concept that met the performance, weight and cost targets; (ii) Cell Material Development and Scaleup – to demonstrate scalability of the sputtering process for manufacture of thin-film SOFC cells of practical sizes, confirm the exceptional performance of sputtered cells, improve cell stability and durability for operation with hydrogen and methane fuel, and develop a suitable electrically conducting porous substrate to replace the current non-conducting ceramic substrate; (iii) Stack Development – to design and manufacture stack components for the stack architecture, evaluate and select a suitable sealant, and build and operate multi-cell stacks to demonstrate stack operation, and (iv) Technology to Market – to develop business models and commercialization plans, conduct various market and technology analysis and estimate SOFC and ESPG system costs.

25 ENERGY STORAGE↗