Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Structure and assembly of the diiron cofactor in the heme-oxygenase–like domain of the N-nitrosourea–producing enzyme SznF

In biosynthesis of the pancreatic cancer drug streptozotocin, the tridomain nonheme-iron oxygenase SznF hydroxylates N δ and N ω ' of N ω -methyl- L -arginine before oxidatively rearranging the triply modified guanidine to the N-methyl-N-nitrosourea pharmacophore. A previously published structure visualized the monoiron cofactor in the enzyme’s C-terminal cupin domain, which promotes the final rearrangement, but exhibited disorder and minimal metal occupancy in the site of the proposed diiron cofactor in the N-hydroxylating heme-oxygenase–like (HO-like) central domain. We leveraged our recent observation that the N-oxygenating µ-peroxodiiron(III/III) intermediate can form in the HO-like domain after the apo protein self-assembles its diiron(II/II) cofactor to solve structures of SznF with both of its iron cofactors bound. These structures of a biochemically validated member of the emerging heme-oxygenase–like diiron oxidase and oxygenase (HDO) superfamily with intact diiron cofactor reveal both the large-scale conformational change required to assemble the O 2 -reactive Fe 2 (II/II) complex and the structural basis for cofactor instability—a trait shared by the other validated HDOs. During cofactor (dis)assembly, a ligand-harboring core helix dynamically (un)folds. The diiron cofactor also coordinates an unanticipated Glu ligand contributed by an auxiliary helix implicated in substrate binding by docking and molecular dynamics simulations. The additional carboxylate ligand is conserved in another N-oxygenating HDO but not in two HDOs that cleave carbon–hydrogen and carbon–carbon bonds to install olefins. Among ~9,600 sequences identified bioinformatically as members of the emerging HDO superfamily, ~25% conserve this additional carboxylate residue and are thus tentatively assigned as N-oxygenases.

59 BASIC BIOLOGICAL SCIENCES↗

Sea-level rise in Southwest Greenland as a contributor to Viking abandonment

The first records of Greenland Vikings date to 985 CE. Archaeological evidence yields insight into how Vikings lived, yet drivers of their disappearance in the 15th century remain enigmatic. Research suggests a combination of environmental and socioeconomic factors, and the climatic shift from the Medieval Warm Period (~900 to 1250 CE) to the Little Ice Age (~1250 to 1900 CE) may have forced them to abandon Greenland. Glacial geomorphology and paleoclimate research suggest that the Southern Greenland Ice Sheet readvanced during Viking occupation, peaking in the Little Ice Age. Counterintuitively, the readvance caused sea-level rise near the ice margin due to increased gravitational attraction toward the ice sheet and crustal subsidence. We estimate ice growth in Southwestern Greenland using geomorphological indicators and lake core data from previous literature. We calculate the effect of ice growth on regional sea level by applying our ice history to a geophysical model of sea level with a resolution of ~1 km across Southwestern Greenland and compare the results to archaeological evidence. The results indicate that sea level rose up to ~3.3 m outside the glaciation zone during Viking settlement, producing shoreline retreat of hundreds of meters. Sea-level rise was progressive and encompassed the entire Eastern Settlement. Moreover, pervasive flooding would have forced abandonment of many coastal sites. These processes likely contributed to the suite of vulnerabilities that led to Viking abandonment of Greenland. Sea-level change thus represents an integral, missing element of the Viking story.

54 ENVIRONMENTAL SCIENCES↗

Structural basis of transcription: RNA polymerase II substrate binding and metal coordination using a free-electron laser

Catalysis and translocation of multisubunit DNA-directed RNA polymerases underlie all cellular mRNA synthesis. RNA polymerase II (Pol II) synthesizes eukaryotic pre-mRNAs from a DNA template strand buried in its active site. Structural details of catalysis at near-atomic resolution and precise arrangement of key active site components have been elusive. Here, we present the free-electron laser (FEL) structures of a matched ATP-bound Pol II and the hyperactive Rpb1 T834P bridge helix (BH) mutant at the highest resolution to date. The radiation-damage-free FEL structures reveal the full active site interaction network, including the trigger loop (TL) in the closed conformation, bonafide occupancy of both site A and B Mg 2+ , and, more importantly, a putative third (site C) Mg 2+ analogous to that described for some DNA polymerases but not observed previously for cellular RNA polymerases. Molecular dynamics (MD) simulations of the structures indicate that the third Mg 2+ is coordinated and stabilized at its observed position. TL residues provide half of the substrate binding pocket while multiple TL/BH interactions induce conformational changes that could allow translocation upon substrate hydrolysis. Consistent with TL/BH communication, a FEL structure and MD simulations of the T834P mutant reveal rearrangement of some active site interactions supporting potential plasticity in active site function and long-distance effects on both the width of the central channel and TL conformation, likely underlying its increased elongation rate at the expense of fidelity.

Science & Technology - Other Topics↗

Time evolution of a pumped molecular magnet—A time-resolved inelastic neutron scattering study

Introducing an experimental technique of time-resolved inelastic neutron scattering (TRINS), we explore the time-dependent effects of resonant pulsed microwaves on the molecular magnet Cr 8 F 8 Piv 16 . The octagonal rings of magnetic Cr 3+ atoms with antiferromagnetic interactions form a singlet ground state with a weakly split triplet of excitations at 0.8 meV. A 4.6 tesla field was applied to tune the splitting between two members of the triplet excited level |1$\rangle$ ↔ |2$\rangle$ to resonance with 105 GHz (0.434 meV) microwaves. The time-dependent occupations of the ground state |0$\rangle$, lower lying levels |1$\rangle$ and |2$\rangle$, and higher energy states |λ ≥ 3$\rangle$ were extracted during and after 20 s long microwave pulses incident along the (101) direction of a Cr 8 F 8 Piv 16 crystal held at 1.9 K. At significantly elevated spin temperatures, we found underpopulation relative to thermal equilibrium of |2$\rangle$ and spin-lattice thermalization time scales ranging from 1.6(2) s to 5.7(2) s depending on the power level. This contrasts with the relaxation time τ 1 (T → 0) = 27(5) 𝛍 s inferred for |2$\rangle$ from in situ Electron Spin Resonance measurements. By probing a broad range of excited states during intense microwave pumping, TRINS thus provides a first view of long lived excited states in a molecular antiferromagnet.

Science & Technology - Other Topics↗

Reply to Smith and Siegel: Most lithium hops in paddlewheel-claimed conductors occur without spatially and temporally correlated anion-group rotations

We appreciate the engagement from Smith and Siegel on the topic of the “paddlewheel effect” and are pleased to see alignment regarding the absence of a paddlewheel effect, in which large-angle anion-group rotations directly propel lithium hops. In our paper, we clearly state the ambiguity surrounding the term “paddlewheel” to describe lithium transport. We believe that science is not well served by this vague term or its regular redefinition which is why we distinguish three types of anion-group rotation events: large-angle rotations (n-fold rotation returning to a rotationally invariant configuration), librations (e.g., rotational vibrations), and static changes of orientation in response to the change of Li occupancy. Here, we directly evaluate the spatial and temporal correlation between such polyanion rotations and Li hops.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creb5 controls its own expression and directly induces the joint interzone regulatory program

Prior studies have indicated that the transcription factor Creb5 is expressed in the joint interzone, which contains the progenitors for all synovial joint tissues in both mouse and human embryos. In the absence of Creb5 function, most synovial joint interzones fail to form and the cartilage templates in the long bones remain fused. This earlier work did not clarify whether Creb5 initiates a cascade of signaling molecules, such as growth and differentiation factor 5 (Gdf5) and Wnt-family members, that in turn induce the formation of the joint interzone, or instead directly activates the expression of joint interzone markers. In the present study, an integrative analysis of the transcriptome, chromatin accessibility, and Creb5-occupancy in joint progenitors revealed that Creb5 directly binds to both its own two promoters and to the regulatory regions of Gdf5 and Sfrp2, each of whose expression in the joint interzone is Creb5-dependent. Functional enhancer analysis indicated that Creb5 binding sites in either the two Creb5 promoters, or in Gdf5 and Sfrp2 regulatory elements are necessary for these sequences to drive transgene expression in the developing synovial joints. While Creb5 directly drives Gdf5 and Sfrp2 expression in the inner joint interzone, Creb5 activates Barx1 expression specifically in the outer joint interzone. Our findings indicate that Creb5 initiates a regulatory network that both promotes the formation of synovial joints, and subsequently activates distinct transcriptional targets in the inner versus the outer regions of the joint interzone, thus regionalizing gene expression in the developing joint.

Zhang, Cheng-Hai↗

Cuprate superconductors as viewed through a striped lens

Understanding the electron pairing in hole-doped cuprate superconductors has been a challenge, in particular because the “normal” state from which it evolves is unprecedented. Now, after three and a half decades of research, involving a wide range of experimental characterizations, it is possible to delineate a clear and consistent cuprate story. It starts with doping holes into a charge-transfer insulator, resulting in in-gap states. Furthermore, these states exhibit a pseudogap resulting from the competition between antiferromagnetic superexchange J between nearest-neighbor Cu atoms (a real-space interaction) and the kinetic energy of the doped holes, which, in the absence of interactions, would lead to extended Bloch-wave states whose occupancy is characterized in reciprocal space. To develop some degree of coherence on cooling, the spin and charge correlations must self-organize in a cooperative fashion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wave function analysis with a maximum flow algorithm

An efficient algorithm for computing the maximum-flow path in a network is applied to the identification of the dominant configuration state functions (CSFs) in a graphically contracted function (GCF), configuration interaction, wave function. The flow network is a space of spin-adapted CSFs represented by a Shavitt graph, wherein the nodes correspond to orbital occupations and spin quantum numbers. The graph nodes are connected by arcs, and an arc density is defined as sums of the associated squared CSF coefficients. A max-min approach determines an upper bound to the maximum possible incoming flow for each graph node. A backtracking step generates a candidate walk and is followed by a limited search of alternative branching paths for the dominant CSF. The arc density contributions are removed from the graph, and the algorithm is reapplied to the updated graph. This list of generated walks can be partitioned in order to guarantee that the dominant CSFs have been identified. All of the steps in this algorithm are computationally efficient and do not depend on the potentially large dimension of the underlying linear CSF expansion space. An analysis of low-lying valence states of C-2 illustrates the method.

74 ATOMIC AND MOLECULAR PHYSICS↗

Challenges and Opportunities Specific to Microreactors: Compact and Light-Weight Shielding During Operation and Transportation

The problem of designing a shield for a mobile microreactor has been addressed. The principal challenges encountered in this endeavor are the dual goals of increasing radiation protection and decreasing weight. It is recognized that these two goals are contradictory. Increasing shielding naturally increases weight. Conversely, decreasing weight naturally calls for decreasing material inventory, including possibly decreasing shield mass. The operational and regulatory drivers for shielding and transportation constraints are identified and summarized. The main constraints pertain to volume, mass, radiation dose, material feasibility and availability, and decommissioning expectations. The latter are limits on residual contamination and dose rates after the reactor is removed. Progress toward solving the challenge of shielding a transportable microreactor is made by considering a tungsten tetraboride (WB4) shell surrounding the reactor vessel. The shield and a generic microreactor were modeled using the MCNP code. It was determined that the presence of a 16-cm-thick WB4 shield reduces the dose equivalent rate during operations to 3.6 mrem/h just outside of a concrete vault and dome and soil berm surrounding the reactor, which is very near the occupational dose rate limits. Without the WB4 layer, the dose rate at the same location outside the berm would be 120 mrem/h. Most importantly, the presence of the WB4 shield substantially protects the surrounding concrete and soil from activation, thus decreasing the duration of administrative control for the site following removal of the reactor from 16 to 3.4 years. At that point, the site may be decommissioned and returned to unrestricted public access. A limitation on the incorporation of a WB4 shield as an intrinsic component of a microreactor is that it results in a design that is transportable only by using the largest road conveyances and that the load would require special permits for transit through the U.S. highway system. New directions for further improvements and possibly more effective solutions to the shielding problem of a mobile microreactor are discussed in the conclusion section.

Microreactor↗

Equation of state for Hf, Ta, W, Re, Os, Ir, Pt, and Au to multi-terapascal pressures from density-functional theory

We present the zero-temperature equation of state (pressure dependence of compression) and phase stability predictions for the 5d-transition metals obtained from all-electron density-functional theory (DFT) calculations. The results compare favorably with experiments but extend beyond current experimental capabilities to 10 TPa. Our study reveals phase changes that are explained from the calculated electronic structure. The cubic face-centered and body-centered structures (fcc and bcc), together with two-, three-, and four-layered hexagonal structures, play major roles under compression. The results’ dependence on the electron exchange and correlation in the DFT approach is investigated, and it is shown that the impact of the choice, while significant at lower pressures, diminishes in the terapascal regime. We further illustrate that the normal parabolic trends in atomic volume and bulk modulus with atomic number, due to the occupation of bonding and anti-bonding 5d states, break down at TPa pressures, suggesting drastically different chemical bonding at these extreme conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mortality among Tennessee Eastman Corporation (TEC) uranium processing workers, 1943–2019

Background: There are few occupational studies of women exposed to ionizing radiation. During World War II, the Tennessee Eastman Corporation (TEC) operated an electromagnetic field separation facility of 1152 calutrons to obtain enriched uranium (235U) used for the Hiroshima atomic bomb. Thousands of women were involved in these operations. Materials and methods: We report a new study was conducted of 13,951 women and 12,699 men employed at TEC between 1943 and 1947 for at least 90 days. Comprehensive dose reconstruction techniques were used to estimate lung doses from the inhalation of uranium dust based on airborne measurements. Vital status through 2018/2019 was obtained from the National Death Index, Social Security Death Index, Tennessee death records and online public record databases. Analyses included standardized mortality ratios (SMRs) and Cox proportional hazards models. Results: Most workers were hourly (77.7%), white (95.6%), born before 1920 (58.3%), worked in dusty environments (57.0%), and had died (94.9%). Vital status was confirmed for 97.4% of the workers. Women were younger than men when first employed: mean ages 25.0 years and 33.0 years, respectively. The estimated mean absorbed dose to the lung was 32.7 mGy (max 1048 mGy) for women and 18.9 mGy (max 501 mGy) for men. The mean dose to thoracic lymph nodes (TLNs) was 127 mGy. Statistically significant SMRs were observed for lung cancer (SMR 1.25; 95% CI 1.19, 1.31; n = 1654), nonmalignant respiratory diseases (NMRDs) (1.23; 95% CI 1.19, 1.28; n = 2585), and cerebrovascular disease (CeVD) (1.13; 95% CI 1.08, 1.18; n = 1945). For lung cancer, the excess relative rate (ERR) at 100 mGy (95% CI) was 0.01 (–0.10, 0.12; n = 652) among women, and –0.15 (–0.38, 0.07; n = 1002) among men based on a preferred model for men with lung doses <300 mGy. NMRD and non-Hodgkin lymphoma were not associated with estimated absorbed dose to the lung or TLN. Conclusions: There was little evidence that radiation increased the risk of lung cancer, suggesting that inhalation of uranium dust and the associated high-LET alpha particle exposure to lung tissue experienced over a few years is less effective in causing lung cancer than other types of exposures. There was no statistically significant difference in the lung cancer risk estimates between men and women. The elevation of certain causes of death such as CeVD is unexplained and will require additional scrutiny of workplace or lifestyle factors given that radiation is an unlikely contributor since only the lung and lymph nodes received appreciable dose.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Learning electric vehicle driver range anxiety with an initial state of charge-oriented gradient boosting approach

This manuscript focuses on the modeling of electric vehicle (EV) driver’s range anxiety, a fear that a vehicle does not have sufficient range, or state of charge (SOC) of the battery pack, to reach its destination and would strand its occupants. Despite numerous research studies on the modeling of charging behaviors, modeling efforts to understand at what battery percentages do EV drivers charge their vehicles, and what are the associated contributing factors, are rather limited. To this end, an ensemble learning model based on gradient boosting is developed. The model sequentially fits new predictors to new residuals of the previous prediction and, then, minimizes the loss when adding the latest prediction. A total of 18 features are defined and extracted from the multisource data, which cover information on driver, vehicles, stations, traffic conditions, as well as spatial-temporal context information of the charging events. The analyzed dataset includes 4.5-year’s charging event log data from 3,096 users and 468 public charging stations in Kansas City Missouri, and the macroscopic travel demand model maintained by the metropolitan planning organization. Here, the result shows the proposed model achieved a satisfactory result with a R square value of 0.54 and root mean square error of 0.14, both better than multiple linear regression model and random forest model. To reduce range anxiety, it is suggested that the priorities of deploying new charging facilities should be given to the areas with higher daily traffic prediction, with more conservative EV users or that are further from residential areas.

33 ADVANCED PROPULSION SYSTEMS↗

Segmenting the target audience for transportation demand management programs: An investigation between mode shift and individual characteristics

Understanding the characteristics of travelers and situations that are more likely to switch from single occupancy vehicles (SOV) to more sustainable mobility options can help transportation agencies develop better behavior change strategies. Existing mode shift programs, however, rarely identify their target audience, which could make the programs less effective. Here, to investigate the demographics and trip characteristics of those who are more likely to shift from SOV to carpooling, public transit, and micromobility (e.g. walking, biking), a matrix decomposition audience segmentation method is proposed and applied on travel survey data. The results of this research show that for short-distance leisure or social trips, young and middle-income people are more likely to shift to these mobility options from SOV. This study provides a comprehensive and profound understanding of the characteristics of the target audience that can inform policies to create more targeted behavior change strategies to reach their sustainability goals.

42 ENGINEERING↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methodology and analytical approach to investigate the impact of building temperature setpoint schedules

This work presents a method for generating a large set of stochastically varying temperature setpoint schedules for building performance simulations. It analyses tradeoffs resulting from specific changes to those schedules in terms of three quantities: total electricity consumption per day; maximum hourly electricity consumption per day and predicted percentage dissatisfied (occupant thermal comfort). The method for generating schedules requires a single base schedule as the starting point and, using a few clearly defined parameters, transforms it into a set of schedules that can be used for modelling an existing building stock or for performing parametric studies. Temperature setpoint schedules are generated and simulated for a small office building in a cool-dry climate in three different case studies pertaining to changing temperature setpoint schedules. Tradeoffs between the three output metrics are significant and vary based on the temperature setpoint schedules and the time of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST↗

On-policy learning-based deep reinforcement learning assessment for building control efficiency and stability

Artificial intelligence technologies have emerged as a game changer not only in specific applications such as image recognition and machine translation but also in many scientific domains. In particular, as deep reinforcement learning (DRL) has shown great success in complex control problems, DRL-based control has been considered as a potential solution to efficiently control and manage building systems. However, broad assessment of DRL-based building control is still required to characterize their pros and cons in comparison with conventional building control methods (e.g., rule-based feedback controls). In this paper, we assessed DRL-based controls with on-policy learning-based algorithms and continuous control actions for cooling control of large office buildings in the summer season to minimize whole-building energy use and occupant discomfort. We compared DRL-based control methods with two baseline control methods: (1) a pre-determined schedule with supply temperature and static pressure setpoints, and (2) advanced reset method that adjusts setpoints based on heuristic rules, i.e., ASHRAE Guideline 36. We also tested the DRL algorithms to evaluate their performances in multiple climate locations. We found that DRL-based control methods outperformed the baseline control methods in terms of energy savings while maintaining a thermal comfort. DRL reduced energy use between ~4%–22% on average compared to the baseline methods, depending on climate location. We also evaluated DRL-based control in terms of control stability and showed that DRL-based methods should address the span of hardware lifetimes in practical operations.

control stability↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗