Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Video”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Stennis Space Center's approach to liquid rocket engine health monitoring using exhaust plume diagnostics

Details are presented of the approach used in a comprehensive program to utilize exhaust plume diagnostics for rocket engine health-and-condition monitoring and assessing SSME component wear and degradation. This approach incorporates both spectral and video monitoring of the exhaust plume. Video monitoring provides qualitative data for certain types of component wear while spectral monitoring allows both quantitative and qualitative information. Consideration is given to spectral identification of SSME materials and baseline plume emissions.

Gardner, D. G.↗

Gain, Level, And Exposure Control For A Television Camera

Automatic-level-control/automatic-gain-control (ALC/AGC) system for charge-coupled-device (CCD) color television camera prevents over-loading in bright scenes using technique for measuring brightness of scene from red, green, and blue output signals and processing these into adjustments of video amplifiers and iris on camera lens. System faster, does not distort video brightness signals, and built with smaller components.

Major, Geoffrey J.↗

Flow visualization and flow field measurements of a 1/12 scale tilt rotor aircraft in hover

The results are given of flow visualization studies and inflow velocity field measurements performed on a 1/12 scale model of the XV-15 tilt rotor aircraft in the hover mode. The complex recirculating flow due to the rotor-wake-body interactions characteristic of tilt rotors was studied visually using neutrally buoyant soap bubbles and quantitatively using hot wire anemometry. Still and video photography were used to record the flow patterns. Analysis of the photos and video provided information on the physical dimensions of the recirculating fountain flow and on details of the flow including the relative unsteadiness and turbulence characteristics of the flow. Recirculating flows were also observed along the length of the fuselage. Hot wire anemometry results indicate that the wing under the rotor acts to obstruct the inflow causing a deficit in the inflow velocities over the inboard region of the model. Hot wire anemometry also shows that the turbulence intensities in the inflow are much higher in the recirculating fountain reingestion zone.

Coffen, Charles D.↗

The effect of on/off indicator design on state confusion, preference, and response time performance, executive summary

Investigated are five designs of software-based ON/OFF indicators in a hypothetical Space Station Power System monitoring task. The hardware equivalent of the indicators used in the present study is the traditional indicator light that illuminates an ON label or an OFF label. Coding methods used to represent the active state were reverse video, color, frame, check, or reverse video with check. Display background color was also varied. Subjects made judgments concerning the state of indicators that resulted in very low error rates and high percentages of agreement across indicator designs. Response time measures for each of the five indicator designs did not differ significantly, although subjects reported that color was the best communicator. The impact of these results on indicator design is discussed.

Donner, Kimberly A.↗

Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

Perry, Jimmy L.↗

An electronic pan/tilt/zoom camera system

A camera system for omnidirectional image viewing applications that provides pan, tilt, zoom, and rotational orientation within a hemispherical field of view (FOV) using no moving parts was developed. The imaging device is based on the effect that from a fisheye lens, which produces a circular image of an entire hemispherical FOV, can be mathematically corrected using high speed electronic circuitry. An incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical FOV without the need for any mechanical mechanisms. A programmable transformation processor provides flexible control over viewing situations. Multiple images, each with different image magnifications and pan tilt rotation parameters, can be obtained from a single camera. The image transformation device can provide corrected images at frame rates compatible with RS-170 standard video equipment.

Zimmermann, Steve↗

Fiber optic TV direct

The objective of the operational television (OTV) technology was to develop a multiple camera system (up to 256 cameras) for NASA Kennedy installations where camera video, synchronization, control, and status data are transmitted bidirectionally via a single fiber cable at distances in excess of five miles. It is shown that the benefits (such as improved video performance, immunity from electromagnetic interference and radio frequency interference, elimination of repeater stations, and more system configuration flexibility) can be realized if application of the proven fiber optic transmission concept is used. The control system will marry the lens, pan and tilt, and camera control functions into a modular based Local Area Network (LAN) control network. Such a system does not exist commercially at present since the Television Broadcast Industry's current practice is to divorce the positional controls from the camera control system. The application software developed for this system will have direct applicability to similar systems in industry using LAN based control systems.

Kassak, John E.↗

Techniques for animation of CFD results

Video animation is becoming increasingly vital to the computational fluid dynamics researcher, not just for presentation, but for recording and comparing dynamic visualizations that are beyond the current capabilities of even the most powerful graphic workstation. To meet these needs, Lewis Research Center has recently established a facility to provide users with easy access to advanced video animation capabilities. However, producing animation that is both visually effective and scientifically accurate involves various technological and aesthetic considerations that must be understood both by the researcher and those supporting the visualization process. These considerations include: scan conversion, color conversion, and spatial ambiguities.

Horowitz, Jay↗

Color image processing and object tracking workstation

A system is described for automatic and semiautomatic tracking of objects on film or video tape which was developed to meet the needs of the microgravity combustion and fluid science experiments at NASA Lewis. The system consists of individual hardware parts working under computer control to achieve a high degree of automation. The most important hardware parts include 16 mm film projector, a lens system, a video camera, an S-VHS tapedeck, a frame grabber, and some storage and output devices. Both the projector and tapedeck have a computer interface enabling remote control. Tracking software was developed to control the overall operation. In the automatic mode, the main tracking program controls the projector or the tapedeck frame incrementation, grabs a frame, processes it, locates the edge of the objects being tracked, and stores the coordinates in a file. This process is performed repeatedly until the last frame is reached. Three representative applications are described. These applications represent typical uses and include tracking the propagation of a flame front, tracking the movement of a liquid-gas interface with extremely poor visibility, and characterizing a diffusion flame according to color and shape.

Klimek, Robert B.↗

The NASA/NSO spectromagnetograph

The Kitt Peak Vacuum Telescope's spectromagnetograph features real-time digital analysis of long-slit spectra formed on a 2D CCD detector, and is located at an exit port of a Littrow spectrograph. Commercial video processing boards are used to digitize the spectral images at video rates and to separate, accumulate, and buffer the spectra in the two polarization states. A processor removes fixed-pattern bias and gain from the spectra in cadence with spatial scanning of the image across the entrance slit; a data-control computer conducts position and width analysis of the line profiles and records line-of-sight magnetic field, Doppler shift, and other computed parameters, as demonstrated by the early observations presented.

Jones, Harrison P.↗

Signal processing schemes for Doppler global velocimetry

Two schemes for processing signals obtained from the Doppler global velocimeter are described. The analog approach is a simple, real-time method for obtaining an RS-170 video signal containing the normalized intensity image. Pseudocolors are added using a monochromatic frame grabber producing a standard NTSC video signal that can be monitored and/or recorded. The digital approach is more complicated, but maintains the full resolution of the acquisition cameras with the ability to correct the signal image for pixel sensitivity variations and to remove background light. Prototype circuits for each scheme are described, and example results from the investigation of the vortical flow field above a 75-deg delta wing are presented.

Meyers, James F.↗

Automated Recognition Of Melt Lines In Phase-Change Paints

Technique developed to reduce data quickly and objectively in images of phase-change paints. Involves use of three-tube color-camera system. Camera modified so separate red (R), green (G), and blue (B) video outputs contain complete framing information recorded and digitized by use of standard video format. Proven very simple and repeatable. Used wherever rapid and accurate remote temperature-profile measurements desired; for example, for test objects in inaccessible, toxic, or other hostile areas.

Buck, Gregory M.↗

Vector Quantization With Emergent Codebook Structure

Proposed scheme under development for transmission of vector-quantized digital video images, vector quantizer codebook updated to adapt quantizer to changing signal statistics. Intended to be realized with electronic neural network. Codebook, which consists of patterns constituting video images, will undergo training during operation and scheme will develop codebooks ordered during training. System enables coding more compact, more immune to noise, and supports variable rate compression.

Ahalt, Stanley C.↗

Robotic Tube-Gap Inspector

Robotic vision system measures small gaps between nearly parallel tubes. Robot-held video camera examines closely spaced tubes while computer determines gaps between tubes. Video monitor simultaneously displays data on gaps.

Gilbert, Jeffrey L.↗

Close-up analysis of aircraft ice accretion

Various types of ice formation have been studied by analysis of high magnification video observations. All testing was conducted in the NASA Lewis Icing Research Tunnel (IRT). A faired 8.9 cm (3.5 in.) diameter metal-clad cylinder and a 5.1 (2 in.) aluminum cylinder were observed by close-up and overview video cameras for several wind tunnel conditions. These included close-up grazing angle, close-up side view, as well as overhead and side overview cameras. Still photographs were taken at the end of each spray along with tracings of the subsequent ice shape. While in earlier tests only the stagnation region was observed, the entire area from the stagnation line to the horn region of glaze ice shapes was observed in this test. The modes or horn formation have been identified within the range of conditions observed. In the horn region, Horn Type A ice is formed by 'dry' feather growth into the flow direction and Horn Type B is formed by a 'wet' growth normal to the surface. The feather growth occurs when the freezing fraction is near unity and roughness elements exist to provide an initial growth site.

Hansman, R. John↗

Stability of metal particle and metal particulate media

Metal particulate (MP) video tape was launched for 8 mm video tape in 1985. Since then MP tapes have been applied to several consumer formats and instrumental formats because of its superior electrical performance. Recently data storage media, such as DDS and D-8, have started employing MP tape. However, there are serious concerns with archival stability of MP tape particularly in the case of data storage use, as metal particles essentially have problems with chemical instability and are susceptible to oxidation and corrosion. Although there were some studies about the archival stability of metal particles or MP tapes, a clear understanding has yet to be reached. In this paper, we report the stability of magnetic properties of current metal particles, and then discuss the new technologies to improve the stability further.

Okamoto, Kazuhiro↗

Dark-cycle monitoring of biological subjects on Space Station Freedom

The operational environment for biological research on Space Station Freedom will incorporate video technology for monitoring plant and animal subjects. The video coverage must include dark-cycle monitoring because early experiments will use rodents that are nocturnal and therefore most active during the dark part of the daily cycle. Scientific requirements for monitoring during the dark cycle are exacting. Infrared (IR) or near-IR sensors are required. The trade-offs between these two types of sensors are based on engineering constraints, sensitivity spectra, and the quality of imagery possible from each type. This paper presents results of a study conducted by the Biological Flight Research Projects Office in conjunction with the Spacecraft Data Systems Branch at ARC to investigate the use of charged-coupled-device and IR cameras to meet the scientific requirements. Also examined is the effect of low levels of near-IR illumination on the circadian rhythm in rats.

Chuang, Sherry↗

Transient liquid-crystal technique used to produce high-resolution convective heat-transfer-coefficient maps

In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.

Hippensteele, Steven A.↗