At least 1,117 records · Page 62

Unified continuum damage model for matrix cracking in composite rotor blades

This paper deals with modeling of the first damage mode, matrix micro-cracking, in helicopter rotor/wind turbine blades and how this effects the overall cross-sectional stiffness. The helicopter/wind turbine rotor system operates in a highly dynamic and unsteady environment leading to severe vibratory loads present in the system. Repeated exposure to this loading condition can induce damage in the composite rotor blades. These rotor/turbine blades are generally made of fiber-reinforced laminated composites and exhibit various competing modes of damage such as matrix micro-cracking, delamination, and fiber breakage. There is a need to study the behavior of the composite rotor system under various key damage modes in composite materials for developing Structural Health Monitoring (SHM) system. Each blade is modeled as a beam based on geometrically non-linear 3-D elasticity theory. Each blade thus splits into 2-D analyzes of cross-sections and non-linear 1-D analyzes along the beam reference curves. Two different tools are used here for complete 3-D analysis: VABS for 2-D cross-sectional analysis and GEBT for 1-D beam analysis. The physically-based failure models for matrix in compression and tension loading are used in the present work. Matrix cracking is detected using two failure criterion: Matrix Failure in Compression and Matrix Failure in Tension which are based on the recovered field. A strain variable is set which drives the damage variable for matrix cracking and this damage variable is used to estimate the reduced cross-sectional stiffness. The matrix micro-cracking is performed in two different approaches: (i) Element-wise, and (ii) Node-wise. The procedure presented in this paper is implemented in VABS as matrix micro-cracking modeling module. Three examples are presented to investigate the matrix failure model which illustrate the effect of matrix cracking on cross-sectional stiffness by varying the applied cyclic load.

36 MATERIALS SCIENCE↗

Catalytic and electrochemical behaviour of solid oxide fuel cell operated with simulated-biogas mixtures

Being produced from organic matters of wastes (bio-wastes) through a fermentation process, biogas mainly composed of CH{sub 4} and CO{sub 2} and can be considered as a secondary energy carrier derived from solar energy. To generate electricity from biogas through the electrochemical process in fuel cells is a state-of-the-art technology possessing higher energy conversion efficiency without harmful emissions compared to combustion process in heat engines. Getting benefits from high operating temperature such as direct internal reforming ability and activation of electrochemical reactions to increase overall system efficiency, solid oxide fuel cell (SOFC) system operated with biogas becomes a promising candidate for distributed power generator for rural applications leading to reductions of environmental issues caused by greenhouse effects and bio-wastes. CO{sub 2} reforming of CH{sub 4} and electrochemical oxidation of the produced syngas (H{sub 2}–CO mixture) are two main reaction processes within porous anode material of SOFC. Here catalytic and electrochemical behavior of Ni-ScSZ (scandia stabilized-zirconia) anode in the feed of CH{sub 4}–CO{sub 2} mixtures as simulated-biogas at 800 °C were evaluated. The results showed that CO{sub 2} had strong influences on both reaction processes. The increase in CO{sub 2} partial pressure resulted in the decrease in anode overvoltage, although open-circuit voltage was dropped. Besides that, the simulation result based on a power-law model for equimolar CH{sub 4}−CO{sub 2} mixture revealed that coking hazard could be suppressed along the fuel flow channel in both open-circuit and closed-circuit conditions.

09 BIOMASS FUELS↗

Joint Chance Constraints Reduction Through Learning in Active Distribution Networks

Due to an increase in distributed generation and controllable loads, distribution networks are frequently operating under high levels of uncertainty. Joint chance constraints, which seek to satisfy multiple constraints simultaneously with a prescribed probability, are one way to incorporate uncertainty across sets of constraints for optimization and control of these networks. Due to the complexity of evaluating these constraints directly, sampling approaches or approximations can be used to transform the joint chance constraint into deterministic constraints. However, sampling techniques may be extremely computationally expensive and not suitable for physical networks operating on fast timescales, and conservative approximations may needlessly result in a much higher cost of system operation. The proposed framework aims to provide a scalable, data-driven approach which learns operational trends in a power network, eliminates zero-probability events (e.g., inactive constraints), and uses this additional information to accurately and efficiently approximate the joint chance constraint directly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ARMAX-Based Transfer Function Model Identification Using Wide-Area Measurement for Adaptive and Coordinated Damping Control

One of the main drawbacks of the existing oscillation damping controllers that are designed based on offline dynamic models is adaptivity to the power system operating condition. With the increasing availability of wide-area measurements and the rapid development of system identification techniques, it is possible to identify a measurement-based transfer function model online that can be used to tune the oscillation damping controller. Such a model could capture all dominant oscillation modes for adaptive and coordinated oscillation damping control. our paper describes a comprehensive approach to identify a low-order transfer function model of a power system using a multi-input multi-output (MIMO) autoregressive moving average exogenous (ARMAX) model. This methodology consists of five steps: 1) input selection; 2) output selection; 3) identification trigger; 4) model estimation; and 5) model validation. The proposed method is validated by using ambient data and ring-down data in the 16-machine 68-bus Northeast Power Coordinating Council system. Our results demonstrate that the measurement-based model using MIMO ARMAX can capture all the dominant oscillation modes. Compared with the MIMO subspace state space model, the MIMO ARMAX model has equivalent accuracy but lower order and improved computational efficiency. The proposed model can be applied for adaptive and coordinated oscillation damping control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PSI (PowerSimulations.jl) [SWR-23-104]

PowerSimulations.jl is a Julia-based BSD- licensed power system operations simulation tool developed as a flexible and open source software for quasi-static power systems simulations including Production Cost Models. PowerSimulations.jl tackles the issues of developing a simulation model in a modular way providing tools for the formulation of decision models and emulation models that can be solved independently or in an interconnected fashion. For further information regarding the Sienna modeling framework at NREL, see: https://www.nrel.gov/analysis/sienna.html

Lara Aguilar, Jose Daniel↗

Pumped Storage Hydro Model Evaluation Report Task 1: Tool Assessment

Pumped storage hydro (PSH) projects support various aspects of power system operations. However, determining the value of PSH projects and the many services and contributions to the system they provide can be a challenge. The PSH techno-economic studies being carried out by a 5-lab consortium are defining extensive modeling approaches for evaluating the economic benefits of PSH projects. To enhance the impact of the valuation approach and follow-on techno-economic studies, Pacific Northwest National Laboratory (PNNL) will be developing a set of online tools that industry could adopt and use to advance PSH projects in the US. The problem is that the research team is not entirely clear on the features of the tools that would offer the most significant impact to industry. Thus, year one of this effort is designed to first define the needs of industry before developing the PSH valuation tool. The first step in defining industry needs is to evaluate existing tool packages, including those created by DOE and those by industry groups, to both measure usage levels and define tool attributes that maximize industry impact. The second step in this process will be to hold a workshop designed to elicit direct industry input. Given the breadth and nature of the task, which is to define ideal model attributes, the research team did not constrain the assessment to storage valuation tools. Several tools were assessed, and their characteristics compared against a list of “ideal” attributes that included ease of use, generalizability of results, and analytical flexibility. Information regarding usage and impact were then compared to specific model attributes to define which attributes appear to drive success. The following key lessons and implications can be drawn from the analysis: Models with high ease of use were often the most adopted by industry, though they did not necessarily have high publication reference records, meaning a published article made direct reference to the tool. For example, REScheck TM and COMcheck TM , two tools which share a site, have seen a high amount of web traffic and usage. Similarly, Storage Value Estimate Tool (StorageVET®), an energy storage valuation model, has a large number of organizations using it despite a low publication reference record. A common feature between these models is that they are web-hosted, theoretically making them more easily accessible with graphic user interfaces (GUIs) that are more navigable; Models with higher usage statistics were typically free and/or open source. While it may be unsurprising that this attribute could be considered a draw for users, there is the potential for overestimating the tool's value based on popularity due to the fact that some users may have used the model simply because it was free and not because it is the best model; Models that offer more in-depth analysis and a wide coverage of applications (e.g. VOLTTRON™, GridLAB-D™, and Integrated Valuation of Ecosystem Services and Tradeoffs (InVest)) have shown a high number of publication references as well as showing a high number of downloads in the case of GridLAB-D™. It should be noted that the figure below does not include the model with the highest number of publication references (EnergyPlus™) as it has been removed to show clearer distinction between the remaining tools; The most popular model within the evaluation list was EnergyPlus™. This tool has the highest number of publication references (2,034) of all models considered and contains both a high ease of use level as well as broad application flexibility. Its high usage may be correlated, however, with the presumed wider audience conducting energy consumption modeling compared to the audiences for some of the other tools in this list; Models that were low in both general usage and publication reference generally did not exhibit characteristics considered ideal by the research team. Some of these models offered a narrower range of analytical applications or lower generalizability of results. This would automatically restrict the pool of potential users to those who fall within a narrow range of specific technologies or applications. This report also explores two model structures for the PSH tool: decision tree-based, which would guide the user through the valuation methods defined in the PSH techno-economic studies currently being carried out by DOE, and an all-inclusive comprehensive model. The strengths of each were explored and a hybrid approach was defined that would embed a price taker model into the decision tree approach. Such an approach would provide a comprehensive approach for modeling small-scale PSH while recognizing the challenges associated with implementing a price-maker approach in an all-inclusive model. Insight gained in this analysis of other models can aid in narrowing down the list of effective and sought-after attributes, and in defining model structure. Next steps toward developing a model for storage valuation will be to gain direct industry input through workshops.

13 HYDRO ENERGY↗

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities: Preprint

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources downstream of a regulated distribution system operator's (DSO) net energy metering revenue meter. Due to the elevated risk of grid constraint violations and to ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, the proposed community market mechanism maximizes the community's social welfare in a decentralized fashion while every community member abides by its own operating envelopes. We show that the proposed market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. Lastly, a numerical study is implemented to showcase and compare the community's welfare under the proposed operating-envelopes-aware mechanisms to others, including the welfare of customers under the DSO's regime.

distributed energy resources aggregation↗

Minimizing System Noise Effects For Extreme-Scale Scientific Simulation Through Function Delegation

The primary goal of the Minimizing System Noise Effects For Extreme-Scale Scientific Simulation through Function Delegation project is to eliminate or at best strongly minimize the impact of the noise introduced by the operating system, during large scale parallel applications runs. Collective communication operations are a basic building block for parallel programing models and scientific applications. These operations often dominate execution time of applications and tend to limit their scalability. In order to address this challenge, we evaluated different strategies to adapt the collective communications underlying topologies to the hardware architecture in order to provide increased levels of performance to the parallel applications.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana (Fact Sheet)

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana

The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

BSC↗

Success Path Method: Conformance with Safety Management Systems

All industrial facilities deal with safety hazards such as equipment failures, chemical and toxic releases, and fires and explosions just to name a few. A disciplined framework for managing the integrity of operating systems and processes that handle hazardous substances by applying good design principles, engineering, and operating practices is called process safety. The goal of such framewoks is to prevent the release of energy or material that could cause harm to people or damage to equipment and/or environment. Process safety covers all aspects of facility operation also including design, maintenance, and human and organizational factors that could possibly have effect on process safety. As it will be seen from the discussion below, process safety is just one of the pieces of the much bigger matter, a safety culture. Many industries have long recognized the importance of safety culture in their day-to-day operation. Although the definition of safety culture can slightly differ from organization to organization, in general, a safety culture is how things are done to demonstrate a commitment to safety by everyone involved. An organization acquires safety culture over time as the product of individual and group values, actions, and behaviors toward overall safety. It is important to note that safety culture should not be viewed as some static state that an organization wants to reach. It is more like a constantly evolving level of “how things are done when nobody is watching.” Safety culture is an inherent characteristic of an organization, it is always present, but the level can range on a continuum from undesirable to desirable or more commonly used, from negative to positive. An example for an undesirable, negative safety culture would be a company in which accidents resulting in harm (physical and/or emotional) of its employees, equipment or surrounding environment and community occur frequently. At the other end of the spectrum would be a company in which such accidents are rare or do not occur at all (desired or positive safety culture). Every company/industry exists somewhere within this spectrum.

42 ENGINEERING↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Networked Microgrids Scoping Study

While the utilization of a microgrid for local power reliability during grid outage and emergencies is a well-known benefit, the integration of microgrids with the broader electrical distribution system will allow for seamless interaction with distribution system operations, contributing to resource and economic optimization, enhanced reliability and resiliency, and improved power quality. By virtue of integration with the distribution system, multiple microgrids should be networked and collectively known as networked microgrids. As a follow-up to the work conducted by Oak Ridge National Laboratory on a microgrid controller [the Complete System-level Efficient and Interoperable Solution for Microgrid Integrated Controls (CSEISMIC)], the main goal of this work is to identify the next steps for bringing microgrid research to the utility industry, particularly as a resource for enhancing efficiency, reliability, and resilience. Various R&D needs for the integration of microgrids into the distribution system have been proposed, including interconnection types, communications, control architectures, quantification of benefits, functional requirements, and various operational issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress and plan of KSTAR plasma control system upgrade

The plasma control system (PCS) has been one of essential systems in annual KSTAR plasma campaigns: starting from a single-process version in 2008, extensive upgrades are done through the previous 7 years in order to achieve major goals of KSTAR performance enhancement. Here, major implementations are explained in this paper. In consequences of successive upgrades, the present KSTAR PCS is able to achieve ~48 s of 500 kA plasma pulses with full real-time shaping controls and real-time NB power controls. It has become a huge system capable of dealing with 8 separate categories of algorithms, 26 actuators directly controllable during the shot, and real-time data communication units consisting of +180 analog channels and +600 digital input/outputs through the reflective memory (RFM) network. The next upgrade of the KSTAR PCS is planned in 2015 before the campaign. An overview of the upgrade layout will be given for this paper. The real-time system box is planned to use the CERN MRG-Realtime OS, an ITER-compatible standard operating system. New hardware is developed for faster real-time streaming system for future installations of actuators/diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equivalent circuit-level model of quantum cascade lasers with integrated hot-electron and hot-phonon effects

We report a study of the effects of hot-electron and hot-phonon dynamics on the output characteristics of quantum cascade lasers (QCLs) using an equivalent circuit-level model. The model is developed from the energy balance equation to adopt the electron temperature in the active region levels, the heat transfer equation to include the lattice temperature, the nonequilibrium phonon rate to account for the hot phonon dynamics and simplified two-level rate equations to incorporate the carrier and photon dynamics in the active region. This technique simplifies the description of the electron–phonon interaction in QCLs far from the equilibrium condition. Using the presented model, the steady and transient responses of the QCLs for a wide range of sink temperatures (80 to 320 K) are investigated and analysed. The model enables us to explain the operating characteristics found in QCLs. This predictive model is expected to be applicable to all QCL material systems operating in pulsed and cw regimes. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗