Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

DUKE PRO STI TEST at 9965 - RANGE 1 (IMPACT NOISE). Survey Profile Report

Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection. Based on the area impact noise sample results, the attenuation provided by the MFCP was protective for mitigating noise to levels below the ACGIH TLV of 140 dBC. The results also validated the scaled distance equation in an open-air environment as the results at K635 (864 feet) were below 140 dBC.

54 ENVIRONMENTAL SCIENCES↗

Impulse Noise Sampling at 9965 - Armag

One detonation test was monitored for impulse noise at Thunder Range on November 6, 2020. The TNT equivalency for this shot was 100 lbs. Ground zero for this test was located at an open area of Range 7. The Armag, where MOW were remotely located, was just south of the east end of the TR shock tube The purpose of this sampling event was to characterize the noise attenuation provided by the Armag which will be used as the primary firing location in a future test series. To determine attenuation provided by the Armag, one sound level monitor was placed inside and a second monitor was placed outside the hardened structure at the same distance from ground zero. The Armag was located 1300 feet from ground zero. Essential personnel performing these tests were remotely located inside the Armag and wore hearing protection with a minimum NRR of 23. Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection.

42 ENGINEERING↗

Sampling and Analysis Plan for Partial Closure of Solid Waste Management Unit #16; Addendum Part I for Delineating BH-056

On July 11, 2022, Sandia National Laboratories in California (SNL/CA) submitted a Response to Regional Water Quality Control Board Comments on Soil Sampling Results for Closure of a Portion of SWMU #16 in response to the February 16,2022 San Francisco Bay Regional Water Quality Control Board’s (SFRWQCB) letter requesting supporting information for the recommended closure of 7,700 linear feet of abandoned sewer lines. On August 18, 2022, SFRWQCB further requested a Sampling and Analysis Plan (SAP) for additional “step-out” sampling to delineate the potential presence of benzidine near borehole BH-056, which is located near the former sewer line. SNL/CA is in the process of contracting Weiss Associates (Weiss) to perform and oversee the boring, sampling, analysis, and report development to determine the potential presence and extent of benzidine. This document outlines the work that is anticipated, including the development of the SAP, to complete the investigation and submit a final report to the SFRWQCB. The work proposed by Weiss provides an estimated schedule for completing the investigation and developing the addendum Part II SAP for the project. In addition, Weiss provided a preliminary estimate of the sample locations (see Attachment A) which serve as addendum Part I of the SAP requested by the SFRWQCB. The contractor will submit the addendum Part II SAP, to satisfy the SFRWQCB requirement, before proceeding with any work.

54 ENVIRONMENTAL SCIENCES↗

The Cypress Sandstone Seal System

The Cypress Sandstone is the youngest and shallowest unit in the Illinois Basin that was featured in the United States Carbon Utilization and Storage Atlas IV as a target for saline carbon storage with an estimated 0.2 to 2.3 GT of storage potential. Additional research on a residual oil zone (ROZ) developed within the Cypress Sandstone has delineated 27 prospects with approximately 290.8 million m3 (1.8 billion barrels) of oil in place. 21 to 31 million m 3 (144 to 196 million barrels) of oil is estimated to be recoverable using carbon dioxide enhanced oil recovery (CO 2 -EOR). Storage of CO 2 associated with EOR in these ROZ prospects alone, not accounting for associated main pay zones (MPZs), underlying brine formation, or intervals adjacent to or between prospects, is estimated to be up to 10.4 billion tonnes. The Cypress Sandstone is thus well understood to be a CO 2 injection target, both for EOR and associated storage. However, the seal system overlying the Cypress Sandstone is poorly understood. Unlike deeper formations such as the Mt. Simon Sandstone or the St. Peter Sandstone which are either in use as a CO 2 sink or being characterized for prospective storage, respectively, the Cypress is not overlain by hundreds of feet of impermeable shale. Rather, the Cypress is overlain by a lithologically variable interval that is composed generally of shales and limestones with some sandstone in the part of the Basin where the Cypress is deep enough to facilitate CO 2 storage. Also, due to its status as one of the shallowest and most prolific oil reservoirs in the Basin, the seal system overlying the Cypress Sandstone has a relatively high number of legacy well penetrations. The purpose of this report is to characterize the Cypress Sandstone seal system using well logs and available core. Gross thickness, lithology (facies), and mineralogy of seals is described and mapped across the Basin. The column height of CO 2 that can be held is calculated using capillary pressure data from a representative core.

02 PETROLEUM↗

Long-Term Surveillance and Maintenance Plan for the Salmon, Mississippi, Site

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) prepared this Long-Term Surveillance and Maintenance Plan (LTS&M Plan) for the Salmon, Mississippi, Site (the Salmon site) to describe LM’s plan and policy for future site activities. The Salmon site consists of 1470 acres in Lamar County, Mississippi, approximately 10 miles west of Purvis, Mississippi, and about 21 miles southwest of Hattiesburg, Mississippi. The site is located over a large subsurface salt formation referred to as the Tatum Salt Dome. Two nuclear tests (Project Dribble) and two gas explosive tests (Project Miracle Play) were conducted in the salt dome between 1964 and 1970. Salmon, the first nuclear test, was conducted on October 22, 1964, and created a cavity approximately 2700 feet (ft) below ground surface (bgs). The second nuclear test, Sterling, was conducted on December 3, 1966. The Sterling test and the two gas explosions—Diode Tube on February 2, 1969, and Humid Water on April 19, 1970—were all conducted in the cavity created by the Salmon test. The four explosions were conducted as part of the U.S. Atomic Energy Commission’s (AEC’s) Vela Uniform program. Testing at the site ended in 1970 after the second gas detonation. The tests resulted in residual contamination and postdetonation features that require long-term oversight.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Geothermal Shot Analysis for the Geothermal Technologies Office

In 2021, the U.S. Department of Energy (DOE) began the Energy Earthshots initiatives to accelerate breakthroughs of reliable clean energy solutions within the next 10 years. In 2022, the National Renewable Energy Laboratory (NREL) was asked by the DOE Geothermal Technologies Office (GTO) to provide analysis for developing Energy Earthshot targets for Enhanced Geothermal Systems (EGS), human-made underground reservoirs that extract thermal energy from the earth for electricity generation and/or heating applications. The Enhanced Geothermal Shot analysis is based on the technology assumptions in the 2019 GTO report GeoVision: Harnessing the Heat Beneath Our Feet. For Earthshot, we updated some of the technology cost and performance assumptions based on recent technology advances and updated the EGS resource potential to include more detailed analysis. We used the updated EGS supply cost curves to forecast the amount of geothermal electricity generation that could be deployed in the US by 2050 using a capacity expansion model. The results were used to develop a cost target for EGS. On September 8th, 2022, the Enhanced Geothermal Shot was announced. Its target - reduce the cost of EGS by 90%, to $45 per megawatt hour by 2035. This paper summarizes the cost and resource assumptions used in the Enhanced Geothermal Shot. It describes the assumptions used in the Regional Energy Deployment System (ReEDS) capacity expansion model to forecast geothermal deployment and discusses the results.

15 GEOTHERMAL ENERGY↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Starting with Solar: A Preliminary Assessment of Solar Energy Systems in Residential New Construction [Slides]

New homes provide a ready option for states hoping to reduce energy use, as evidenced by the steady increase in energy efficiency requirements in new home building codes. A less common approach is to specifically encourage or require new homes to produce their own carbon-free energy, through the installation of a solar energy system. Adopting these practices nationwide might significantly reduce new home energy use, but the drivers of the new solar home market have not been well studied. Partly filling this gap, this report looks at historical deployment trends of solar on over 500,000 new homes built through 2020 across 19 states and the District of Columbia, most of which were in California. California is a useful test case because if first incentivized in 2007, and more recently required in 2018, new homes to have solar. The report finds that solar adoption rates at roughly 40% in recent years in California eclipse—by a wide margin—rates in other states, which top out near 4%. The presence of California’s New Solar Home Partnership (NSHP) incentives appear strongly correlated with deployment levels, as do builder market share. The Top-10 builders in California installed solar in recent years at rates almost three times the average of non-Top-10 builders in the state. Interestingly, the authors found the same large builders did not install solar at the same elevated rates outside California, which might be related to the lack of incentives, they hypothesize. The report also investigates the characteristics of new solar homes such as living area (i.e., square feet), solar system size, frequency of battery installations, and use of third-party ownership. The authors also include quotes directly from builders to provide context to the findings.

14 SOLAR ENERGY↗

Field Laboratory for Emerging Stacked Unconventional Plays in Central Appalachia

The goal of the Field Laboratory for Emerging Stacked Unconventional Plays (ESUP) in Central Appalachia project was to investigate and characterize the resource potential for multi-play production of emerging unconventional reservoirs in Central Appalachia. Project activities included drilling, logging and coring of a vertical characterization well drilled to basement to approximately 15,000 feet in depth. The data from drilling and well logs as well recovered core samples were used by the research team to support characterization of the geology and potential pay zones within the Nora Gas Field of southwestern Virginia and the greater Central Appalachian Basin. This project was led by Dr. Nino Ripepi of the Virginia Center for Coal and Energy Research (VCCER) in close collaboration with EnerVest Operating LLC (EnerVest). VCCER is housed in the Department of Mining and Minerals Engineering at Virginia Tech and was created by an Act of the Virginia General Assembly on March 30, 1977, as an interdisciplinary study, research, information, and resource facility for the Commonwealth of Virginia. EnerVest is a top tier, low-cost oil and natural gas company with a long history of traditional operating relationships with institutional investors as well as public and private companies. This report summarizes two major research activities: 1) Log and Core Analysis and 2) Numerical Modeling. Core analysis comprises the characterization efforts of the ESUP Field Laboratory and includes a discussion of the well logs run in the deep characterization wells, an initial analysis of those, the number, size and location of cores recovered, core testing and analysis done to date as well as plans for future analysis. Numerical modeling is comprised of seven major modeling efforts, including (1) Multiphysics shale transport modeling work, (2) the developed in-house compositional simulator studies, (3) reservoir modeling studies using GEM software, (4) fracture modeling work using EFRAC3D software and (5) numerical modeling efforts with ABAQUS software, (6) Numerical modeling efforts using FLAC3D and PFC3D, and (7) Automatic Machine Learning (AutoML) Studies.

02 PETROLEUM↗

2016 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Nevada, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The site was the location of an underground nuclear test in 1968, which resulted in residual contamination at and near the detonation depth of approximately 3200 feet (ft) below ground surface (bgs) that requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the Federal Facility Agreement and Consent Order (State of Nevada et al. 1996) (as amended) (FFACO) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (LMS/CNT/S12760) (DOE 2016a) (Closure Report) describes LM’s plan for the long-term postclosure monitoring of radioisotope concentrations and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2016a).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2018 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Nevada, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). CNTA is the site of an underground nuclear test in 1968 that resulted in residual contamination near the detonation depth of 3200 feet (ft); the contamination requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from DOE’s National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the amended Federal Facility Agreement and Consent Order (FFACO) (FFACO 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (DOE 2018a), also called the Closure Report, originally was completed in January 2016 and revised in October 2018; it describes LM’s plan for long-term postclosure monitoring. This includes monitoring of the radioisotopes of interest and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2018a).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2020 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The CNTA is the site of an underground nuclear test in 1968 that resulted in residual contamination near the detonation depth of 3200 feet (ft); the contamination requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from DOE’s National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the amended 1996 Nevada Federal Facility Agreement and Consent Order (FFACO) (State of Nevada et al. 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (DOE 2018), also called the Closure Report, originally was completed in January 2016 and revised in October 2018; it describes LM’s plan for long-term postclosure monitoring. This includes monitoring of the radioisotopes of interest and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2018).

54 ENVIRONMENTAL SCIENCES↗

Oak Ridge National Laboratory Annual Sustainability Report 2023

ORNL, managed under contract by UT-Battelle LLC, is DOE’s largest science and energy laboratory and, as such, executes the widest range of mission capabilities. Diverse expertise spans a broad range of scientific and engineering disciplines, enabling research and science achievements to accelerate the delivery of solutions to the marketplace. ORNL supports DOE’s national missions of scientific discovery, clean energy, and security. To execute these activities, ORNL has grown significantly over 80 years of continuous operations, consisting of facilities with commissioning dates ranging from the 1940s to the present—an extraordinary set of distinctive scientific facilities and equipment. The complexities of such a variety of facilities require teamwork among divisions, a wide variety of conservation projects, and creative strategies to achieve the desired energy and water savings. Such a diverse and unique set of major facilities, totaling over 5.5 million square feet, with 6,000 employees, requires an innovative plan to accomplish advancements in operational efficiencies. ORNL is tasked with the management of an extraordinary set of distinctive scientific facilities and equipment for DOE. ORNL is mission-driven, and its mission has grown substantially over the decades. ORNL’s core research capabilities provide broad science and technology support for DOE in the areas of energy, environment, and national security. Currently, ORNL is a world leader in materials, neutron, and nuclear science and engineering, and in high-performance computing and data analytics. ORNL’s vast portfolio of research facilities must be maintained and carefully upgraded to protect the nation’s investment in scientific analysis. The goal of sustainable and resilient operations is to enable more effective execution of ORNL’s science and technology mission. Sustainable operational practices and enhanced resilience strive for excellent results while remaining diligent in energy conservation, environmental stewardship, asset management, and community engagement. The Sustainable ORNL Program (Sustainable ORNL) Continuous improvements in operational and business processes must be integrated into the fabric of the ORNL culture to maximize the return from the investment made in modernizing facilities and equipment. The Sustainable ORNL program promotes the legacy of system-wide best practices, management commitment, and employee engagement that will lead ORNL into a future of efficient, resilient, and sustainable operations. ORNL leadership and Sustainable ORNL champions receive regular status reports on the progress of each project and focus area (i.e., roadmap) and periodic summary reports. More information can be found at the program’s website. The Sustainable ORNL roadmap structure endorses 15 vital roadmaps. The figure below summarizes the current project assignments and demonstrates that each project contributes to the wellbeing of the whole. Continuous employee engagement and regular status reports confirm the ideals of the program. The roadmap structure is not static; as the science mission advances and the needs of the organization evolve, the Sustainable ORNL roadmap structure elements are modified to align with developing priorities. In 2022, Sustainable ORNL made roadmap changes to better align ORNL to support new federal requirements that have been issued.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Contaminants and Mobility in WMA A-AX Boreholes D0006 and D0008

This study was initiated to determine if subsurface contaminants in the A-AX vadose zone at the Hanford site (boreholes D0006 and D0008) caused corrosion of nearby stainless steel well casings (299-E-24-19, 299-E25-46, and 299-E25-236) and, based on the type and distribution of contaminants, determine if contaminants are from one or more sources including a) the A-104 and/or A-105 tanks, b) the 242A evaporator, and c) the 200-E-286 ditch. A tiered approach was used for characterizing contaminants in vadose zone sediments starting with mobile and total contaminant concentrations (Tier 1), characterizing contaminant speciation (Tier 2), and measuring contaminant leaching (Tier 3). Total and mobile contaminant measurements at seven depths showed elevated sulfate and nitrate in all samples (130 to 280 ft depth), elevated chloride in five depths, and no elevated radionuclides except I-129 in D0006 at 206 to 208 ft depth. If these contaminants were initially acidic, stainless-steel corrosion would occur. However, because sediments likely have a high acid neutralization capacity, an acidic spill would have been neutralized within tens of feet, so casing corrosion would likely occur in shallow sediments. GEL labs data also shows low (but above natural) chromate from shallow to 170 ft depth, then higher chromate to 280 ft, suggesting a surface Cr spill or casing corrosion. GEL labs data also showed evidence of more than one plume, with deep nitrate, sulfate, and chloride migration, but only shallow tritium migration. Tritium should migrate nearly unretarded in the subsurface like nitrate and chloride. Elevated aqueous cations and anions in the D0006 206 to 208' depth pore water (SO 4 2- , NO 3 - , Na + , K + , Ca 2+ , Mg 2+ , Si) could be the result of acid disposal and calcite dissolution at shallow depth, with deeper migration of SO 4 2- , NO 3 - from acids and Ca 2+ and Mg 2+ from calcite. Elevated Si (160 mg/L) indicates dissolution of clays or other silicates, which can also occur in acids. Acid extractable metals did show elevated Cr (but not Fe, Ni, Mo, and Mn) above natural levels, which may indicate stainless-steel well corrosion or transport of metals from a shallow spill. The elevated I-129 in D0006 at 206 to 208' depth was low with 0.34 μg/g in pore water and 1.5 μg/g total extractable I-129 in the sediment, which indicates significant fraction of I-129 was bound in one or more precipitates. Although total I-129 was below detection limits in most extractions due to high molybdate interference, I-127 analysis provided some insight into potential precipitate phases. Total I-127 was mainly extracted by acetate or acetic acid (67%), which may be iodine in calcite. Inorganic carbon measurement identified 1.65% calcite, and total organic carbon (TOC) was below detection limits, so iodine was not associated with organic matter. Nearly all the I-127 was present as iodide. In 1-D leach experiments, I-127 as iodide leached from the sediment within 2 pore volumes. Due to high and dynamic molybdate leaching from the sediment and interference with I-129 analysis, there were few quantifiable I-129 measurements. The calculated molybdate release rates from the sediment suggested Mo was being released from the same precipitate phase, such as molybdate incorporated into calcite. Overall, because there was little radioactive contamination measured in D0006 and D0008 boreholes, potential releases from A-104 and A-105 did not reach this location south of the A tank farm. Elevated cations and anions found in D0006 and D0008 at depth as the result of acidic disposal could cause shallow stainless steel casing corrosion. The nearby 242A evaporator generally contained alkaline waste and tritium, but the nearby 200-E-286 ditch generally contained high Cl - liquid effluent, so these are unlikely to be acidic sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reinforcement Learning for Small Autonomous Ground Vehicle

Microcontroller: • ESP-WROOM 32 control board • Wi-Fi 802.11 b/g/n Actuators: • 2 Futaba S3003 Servos • Commanded angles of 0 to 180 • Effectors • Piano wire “legs” and “feet” • Current, Voltage, Power Sensor: • Adafruit INA260 • Range Finder (1D LiDAR) Sensor: • SparkFun VL53L1X • Power Supply: • Battery powered, Adafruit UN3480 Li Ion Polymer 1200 mAh • Adafruit JST 2 PH power breakout board • Body: • Additively manufactured frame

Wells, William Willie↗

Closure Report for the Project Shoal Area: Subsurface Corrective Action Unit 447 Shoal,Nevada, Site

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) has prepared this Closure Report for subsurface Corrective Action Unit (CAU) 447 at the Shoal, Nevada, Site, which was formerly called the Project Shoal Area. The Shoal site was the location of an underground nuclear test in 1963 that resulted in residual radionuclide contamination at the detonation depth of 1211 feet (ft) (DOE 2015a). The environmental restoration process and Corrective Action strategy are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO) (FFACO 1996, as amended) and all applicable Nevada Division of Environmental Protection (NDEP) statues and regulations. Responsibility for the environmental site restoration was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office, to LM on October 1, 2006. The Shoal site is south of U.S. Highway 50, approximately 30 miles southeast of Fallon, in Churchill County, Nevada (Figure 1). The site was selected for underground nuclear testing in 1961, as part of the Vela Uniform Program. Vela was a research and development program directed toward locating, detecting, and identifying underground and high-altitude nuclear detonations. The Vela Uniform program was specific to underground detonations (AEC 1964). The objective of Project Shoal was to detonate a nuclear device underground in an active seismic area to improve the United States’ ability to detect, identify, and locate underground nuclear detonations. The underground nuclear test at Shoal was a joint effort between the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC), which was the predecessor agency to DOE. Figure 1 is a map showing the site location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Planetary Defense System For Responsive Space Missions

As King et al succinctly write, “Collision between the Earth and small objects in the solar system are known to occur regularly, and can result in extinction-level events at their most energetic or more commonly widespread loss of life or economic destruction even for relatively low-energy impacts.” Currently, the JPL Sentry System and the NASA NEO Surveyor mission track, identify, and monitor potential asteroid threats. The JPL Sentry System4 is an automated collision monitoring system which scans the current asteroid catalog for potential impact trajectories with Earth. A 2017 study led by P. Tricarico titled “The near-Earth asteroid population from two decades of observations” analyzes the combined observations of nine leading asteroid surveys. The NASA NEO Surveyor mission seeks to identify 90% of near-Earth objects (NEO) with diameters greater than 140 meters (460 feet) within 10 years. The NEO Surveyor combines data from two infrared imaging detectors to measure NEO size, composition, shape, rotational state, and orbits. Recently, the NASA Double Asteroid Redirection Test (DART) mission successfully altered the orbit of asteroid moon Dimorphos in 2022. This demonstrated that orbit alteration is possible. Thus, collisions between the Earth and asteroids are both likely and demonstrate potential for great harm. There is ongoing work to identify, catalog, and track potential threats. However, when a threat is identified there is not yet a system in place to target the threatening asteroid and defend the planet from potentially existential threats. Building on the DART Mission, we explore a planetary defense system to mitigate asteroid threats.

42 ENGINEERING↗