Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Design of a laser rangefinder for Martian terrain measurements

Methods for using a laser for rangefinding are discussed. These are: (1) Optical Focusing, (2) the Phase Difference Method, and (3) Timed Pulse. For application on a Mars Rover, the Timed Pulse Method proves to be the better choice in view of the requirements set down. This is made possible by pulse expansion techniques described in detail. Initial steps taken toward building the range finder are given, followed by a conclusion which is actually a proposal for future steps.

Palumbo, D. L.↗

Mode-locked frequency doubled Nd:YAG laser

The design, fabrication, test, and delivery of two mode-locked, frequency doubled Nd:YAG laser systems are described. Each system was comprised of two units, the laser head and optics on an Invar plate and the electronics control unit in a relay rack chassis panel. Laser number one operated at a repetition rate of 400 MHz and was designed for use in an optical communication system. Laser number two operated at 200 MHz repetition rate and was designed for optical ranging and target signature experiments. Both lasers had a pulse width of 200 ps at the 10% amplitude points at 1.064 micrometer wavelength (150 ps at 0.532 micrometers) with an amplitude stability of + or - 4%. Output power exceeded the design goals.

Brookman, J. S.↗

The discovery of 38.22 second X-ray pulsations from the vicinity of OAO 1653-40

A 38.22-s X-ray pulsator has been discovered during an 8-hour HEAO 1 pointed observation of the area of sky containing OAO 1653-40. It is found that this pulsing source is not associated with V861 Sco, the proposed optical identification for OAO 1653-40. The spectrum is very hard, the spectral index being about 1.4, with about a 500-eV equivalent width of iron-line emission. No high-energy cutoff is observed.

White, N. E.↗

Airborne differential absorption lidar system for water vapor investigations

Range-resolved water vapor measurements using the differential-absorption lidar (DIAL) technique is described in detail. The system uses two independently tunable optically pumped lasers operating in the near infrared with laser pulses of less than 100 microseconds separation, to minimize concentration errors caused by atmospheric scattering. Water vapor concentration profiles are calculated for each measurement by a minicomputer, in real time. The work is needed in the study of atmospheric motion and thermodynamics as well as in forestry and agriculture problems.

Browell, E. V.↗

dc-free coset codes

A class of block coset codes with disparity and run-length constraints are studied. They are particularly well suited for high-speed optical fiber links and similar channels, where dc-free pulse formats, channel error control, and low-complexity encoder-decoder implementations are required. The codes are derived by partitioning linear block codes. The encoder and decoder structures are the same as those of linear block codes with only slight modifications. A special class of dc-free coset block codes are derived from BCH codes with specified bounds on minimum distance, disparity, and run length. The codes have low disparity levels (a small running digital sum) and good error-correcting capabilities.

Deng, Robert H.↗

Spatiospectral and picosecond spatiotemporal properties of a broad area operating channeled-substrate-planar laser array

Spatiospectral and spatiotemporal properties of an eight-element channeled-substrate-planar laser array are investigated in both CW and pulsed operating conditions. The closely spaced CSP array with strong optical coupling between array elements is characterized by a broad area laserlike operation determined by its spatial mode spectra. The spatiotemporal evolution of the near and far field exhibits complex dynamic behavior in the picosecond to nanosecond domain. Operating parameters for the laser device have been experimentally determined. These results provide important information for the evaluation of the dynamic behavior of coherent semiconductor laser arrays.

Yu, NU↗

Photographic System Makes Path Of Vortex Visible

System making rapid flows visible developed to record track followed by ring vortex when encountering object near its path. Schlieren optical setup includes standard Z-configuration mirror arrangement and pulsed, synchronized source of light. System proves valuable in determining position, velocity, and acceleration of vortex as it passes over and interacts with object in its path.

Jones, Stephen B.↗

Rapid, Nondestructive Readout From Ferroelectric Memory

Proposed devices with nondestructive readout offer attractive alternatives for rugged, solid-state memories suitable for contactless optical addressing and parallel processing and for nonvolatile analog memories. Pulses of light from lasers induce photoresponses in ferroelectric capacitors. Magnitude and polarity of response of each capacitor indicates magnitude and polarity of remanent polarization which, in turn, represents datum stored in that memory cell.

Thakoor, Sarita↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

Raman Lidar Measurements during the International HZO Project: Instrumentation and Analysis Techniques, Popular Summary - 1

The amount of water vapor in the atmosphere helps to determine the likelihood that severe storms may develop. The concentration of water vapor, though, is highly variable in space and time. And yet small changes in water vapor concentration over a short period of time or over a short spatial distance can determine whether a storm may or may not develop. Therefore, in order to improve the ability to forecast severe weather such as thunderstorms it is important to measure water vapor in the atmosphere with high spatial and temporal resolution. One of the most attractive research tools for measuring water vapor in the atmosphere with high spatial and temporal resolution is a Raman lidar. A Raman lidar consists of a laser transmitter, a telescope receiver and optics and electronics for processing opticand electronic signals. A laser pulse is emitted into the atmosphere and it interacts with molecules in the atmosphere causing them to become excited and to emit, through the Raman process, photons of different wavelength than emitted by the laser. The molecule that emitted these emitted. This is the way that a Raman lidar identifies water vapor molecules in the atmosphere. can be identified based on the wavelength of the photons One of the great challenges in Raman lidar measurements has been to make useful daytime measurements of the water vapor profile under bright daytime conditions. In this first of two papers, we describe the instrumentation and analysis of the first documented Raman lidar that is able to measure water vapor in the daytime with sufficient quality to permit the study of developing storm systems.

Whiteman, D. N.↗

Waves in active and passive periodic structures - A review

The theory and recent applications of waves in periodic structures are reviewed. Both the Floquet and coupled waves approach are analyzed in some detail. The theoretical part of the paper includes wave propagation in unbounded and bounded active or passive periodic media, wave scattering from periodic boundaries, source radiation (dipole, Cerenkov, transition, and Smith-Purcell) in periodic media, and pulse transmission through a periodic slab. The applications part covers the recent development in a variety of fields: distributed feedback oscillators, filters, mode converters, couplers, second-harmonic generators, deflectors, modulators, and transducers in the fields of integrated optics and integrated surface acoustics. Work on insect compound eyes, mechanical structures, ocean waves, pulse compressions, temperature waves, and cholesteric liquid crystals, and particles interaction with crystals is briefly reviewed, especially in the case of zeolite crystals and superlattices. Recent advances in fabrication techniques for very fine gratings are also covered.

Elachi, C.↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detector Channel Combining Results from a High Photon Efficiency Optical Communications Link Test Bed

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is developing a low cost, scalable, photon-counting receiver prototype for space-to-ground optical communications links. The receiver is being tested in a test bed that emulates photon-starved space-to-ground optical communication links. The receiver uses an array of single-pixel fiber-coupled superconducting nanowire single-photon detectors. The receiver is designed to receive the high photon efficiency serially concatenated pulse position modulation (SCPPM) waveform specified in the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Blue Book Standard. The optical receiver consists of an array of single-pixel superconducting nanowire detectors, analog phase shifters for channel alignment, digitizers for each detector channel, and digital processing of the received signal. An overview of the test bed and arrayed receiver system is given. Simulation and system characterization results are presented. The data rate increase of using a four-channel arrayed detector system over using one single pixel nanowire detector is characterized. Results indicate that a single-pixel detector is capable of receiving data at a rate of 40 Mbps and a four-channel arrayed detector system is capable of receiving data at a rate of 130 Mbps.

Downey, Jennifer N.↗

Detector Channel Combining Results from a High Photon Efficiency Optical Communications Link Test Bed

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is developing a low cost, scalable, photon counting receiver prototype for space-to-ground optical communications links. The receiver is being tested in a test bed that emulates photon-starved space-to-ground optical communication links. The receiver uses an array of single-pixel fiber-coupled superconducting nanowire single-photon detectors. The receiver is designed to receive the high photon efficiency serially concatenated pulse position modulation (SCPPM) waveform specified in the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Blue Book Standard. The optical receiver consists of an array of single-pixel superconducting nanowire detectors, analog phase shifters for channel alignment, digitizers for each detector channel, and digital processing of the received signal. An overview of the test bed and arrayed receiver system is given. Simulation and system characterization results are presented. The data rate increase of using a four-channel arrayed detector system over using one single pixel nanowire detector is characterized. Results indicate that a single-pixel detector is capable of receiving data at a rate of 40 Mbps and a four-channel arrayed detector system is capable of receiving data at a rate of 130 Mbps.

Downey, Jennifer N.↗

Master-Oscillator/Power-Amplifier Laser System

Master-oscillator/power-amplifier (MOPA) laser system operates in continuous-wave mode or in amplitude-modulation (e.g., pulse) mode by modulation of oscillator current. Power amplifier is laser-diode-pumped neodymium:yttrium lithium fluoride (Nd:YLF) laser; oscillator is laser diode. Offers relatively high efficiency and power. Because drive current to oscillator modulated, external electro-optical modulator not needed. Potential uses include free-space optical communications, coded laser ranging, and generation of high-power, mode-locked pulses.

Yu, Anthony W.↗

Ultrabroadband two-dimensional electronic spectroscopy in the pump–probe geometry using conventional optics

We report ultrabroadband two-dimensional electronic spectroscopy (2D ES) measurements obtained in the pump–probe geometry using conventional optics. A phase-stabilized Michelson interferometer provides the pump-pulse delay interval,τ 1 , necessary to obtain the excitation-frequency dimension. Spectral resolution of the probe beam provides the detection-frequency dimension,ω 3 . The interferometer incorporates active phase stabilization via a piezo stage and feedback from interference of a continuous-wave reference laser detected in quadrature. To demonstrate the method, we measured a well-characterized laser dye sample and obtained the known peak structure. The vibronic peaks are modulated as a function of the waiting time,τ 2 , by vibrational wave packets. The interferometer simplifies ultrabroadband 2D ES measurements and analysis.

Optics↗

Enabling elliptically polarized high harmonic generation with short cross polarized laser pulses

Abstract Enabling elliptically polarized high-order harmonics overcomes a historical limitation in the generation of this highly nonlinear process in atomic, molecular and optical physics with applications in other branches. Here, we shed new light on a controversy between experimental observations and theoretical predictions on the possibility to generate harmonics with large ellipticity using two bichromatic laser pulses which are linearly polarized in orthogonal directions. Results of numerical calculations confirm the previous experimental data that in short laser pulses even harmonics with large ellipticity can be obtained for the interaction of such cross-polarized laser pulses with atoms initially in a s - or p -state, while odd harmonics have low ellipticity. The amount of the ellipticity can be controlled via the relative carrier-envelope phase of the pulses, their intensity ratio and the duration of the pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗