Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

High-Speed Ionic Synaptic Memory Based on 2D Titanium Carbide MXene

Synaptic devices with linear high-speed switching can accelerate learning in artificial neural networks (ANNs) embodied in hardware. Conventional resistive memories however suffer from high write noise and asymmetric conductance tuning, preventing parallel programming of ANN arrays. Electrochemical random-access memories (ECRAMs), where resistive switching occurs by ion insertion into a redox-active channel, aim to address these challenges due to their linear switching and low noise. ECRAMs using 2D materials and metal oxides however suffer from slow ion kinetics, whereas organic ECRAMs enable high-speed operation but face challenges toward on-chip integration due to poor temperature stability of polymers. Here, ECRAMs using 2D titanium carbide (Ti 3 C 2 T x ) MXene that combine the high speed of organics and the integration compatibility of inorganic materials in a single high-performance device are demonstrated. These ECRAMs combine the speed, linearity, write noise, switching energy, and endurance metrics essential for parallel acceleration of ANNs, and importantly, they are stable after heat treatment needed for back-end-of-line integration with Si electronics. The high speed and performance of these ECRAMs introduces MXenes, a large family of 2D carbides and nitrides with more than 30 stoichiometric compositions synthesized to date, as promising candidates for devices operating at the nexus of electrochemistry and electronics.

2D materials↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A versatile pressure-cell design for studying ultrafast molecular-dynamics in supercritical fluids using coherent multi-pulse x-ray scattering

Supercritical fluids (SCFs) can be found in a variety of environmental and industrial processes. They exhibit an anomalous thermodynamic behavior, which originates from their fluctuating heterogeneous micro-structure. Characterizing the dynamics of these fluids at high temperature and high pressure with nanometer spatial and picosecond temporal resolution has been very challenging. The advent of hard x-ray free electron lasers has enabled the development of novel multi-pulse ultrafast x-ray scattering techniques, such as x-ray photon correlation spectroscopy (XPCS) and x-ray pump x-ray probe (XPXP). These techniques offer new opportunities for resolving the ultrafast microscopic behavior in SCFs at unprecedented spatiotemporal resolution, unraveling the dynamics of their micro-structure. However, harnessing these capabilities requires a bespoke high-pressure and high-temperature sample system that is optimized to maximize signal intensity and address instrument-specific challenges, such as drift in beamline components, x-ray scattering background, and multi-x-ray-beam overlap. We present a pressure cell compatible with a wide range of SCFs with built-in optical access for XPCS and XPXP and discuss critical aspects of the pressure cell design, with a particular focus on the design optimization for XPCS.

47 OTHER INSTRUMENTATION↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Wind tunnel mass spectrometer design study

The sampling probe to measure the free stream gas composition in a hypersonic wind tunnel is described. Using a free expansion of the continuum flow, a series of sampling inlet-pumping stages is evaluated. Mass analysis is carried out with a quadrupole mass spectrometer employing a crossed electron beam, molecular beam ion source, and an off-axis electron multiplier. The spatial distribution of the sampled molecular flux and the pumping requirements are evaluated for varying inlet conditions of gas density and flow velocity. The signal-to-noise ratio of the molecular beam formed by this series of coaxial inlets is also determined. The signal-to-noise ratio of the unscattered flux is sufficiently high that an unambiguous determination of the beam composition and of the free stream gas properties can be made. The magnitude of the detected signal is sufficiently high that measurement of trace constituents two orders of magnitude below the primary beam signal can be made.

Hueser, J. E.↗

Discovery of a hectometric solar continuum

Solar continuum emission was detected in the hectometric range for the first time by RAE-1 satellite. Hectometric continuum is quite similar to decametric continuum, showing that the phenomenon extends out in the corona to at least 50 solar radii, or 36.4 gigameters(0.25 AU). An interesting point is that the amplitude distribution and the bandwidth of type 3 bursts associated with hectometric continuum are the same as those of type 1 bursts associated with the metric noise storm. It is believed that the storm radiation all the way from metric through hectometric can be accounted for by plasma wave radiation. This means that streams of superthermal electrons are continuously coming out of active regions and as they travel outward through the interplanetary medium, they produce plasma waves that result in metric, decametric, hectrometric, and probably kilometric storms.

Malitson, H.↗

Phase-locked loops and their application

A collection of papers is presented on the characteristics and capabilities of phase-locked loops (PLLs), along with some applications of interest. The discussion covers basic theory (linear and nonlinear); acquisition; threshold; stability; frequency demodulation and detection; tracking; cycle slipping and loss of lock; phase-locked oscillators; operation and performance in the presence of noise; AGC, AFC, and APC circuits and systems; digital PLL; and applications and miscellaneous. With the rapid development of IC technology, PLLs are expected to be used widely in consumer electronics.

Lindsey, W. C.↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Enhanced imaging of electronic hot spots using quantum squeezed light

Detecting electronic hot spots is important for understanding the heat dissipation and thermal management of electronic and semiconductor devices. Optical thermoreflective imaging is being used to perform precise temporal and spatial imaging of heat on wires and semiconductor materials. We apply quantum squeezed light to perform thermoreflective imaging on micro-wires, surpassing the shot-noise limit of classical approaches. We obtain a far-field temperature sensing accuracy of 42 mK after 50 ms of averaging and show that a 256×256 pixel image can be constructed with such sensitivity in 10 min. We can further obtain single-shot temperature sensing of 1.6 K after only 10 μs of averaging, enabling a dynamical study of heat dissipation. Not only do the quantum images provide accurate spatiotemporal information about heat distribution but also the measure of quantum correlation provides additional information, inaccessible by classical techniques, which can lead to a better understanding of the dynamics. We apply the technique to both aluminum and niobium microwires and discuss the applications of the technique in studying electron dynamics at low temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Transfer learning for analysis of collective and non-collective Thomson scattering spectra

Thomson scattering (TS) diagnostics provide reliable, minimally perturbative measurements of fundamental plasma parameters, such as electron density (⁠n e ) and electron temperature (⁠T e ⁠). Deep neural networks can provide accurate estimates of ⁠n e and T e when conventional fitting algorithms may fail, such as when TS spectra are dominated by noise, or when fast analysis is required for real-time operation. Although deep neural networks typically require large training sets, transfer learning can improve model performance on a target task with limited data by leveraging pre-trained models from related source tasks, where select hidden layers are further trained using target data. We present five architecturally diverse deep neural networks, pre-trained on synthetic TS data and adapted for experimentally measured TS data, to evaluate the efficacy of transfer learning in estimating n e and T e in both the collective and non-collective scattering regimes. We evaluate errors in n e and T e estimates as a function of training set size for models trained with and without transfer learning, and we observe decreases in model error from transfer learning when the training set contains ≲ 200 experimentally measured spectra.

Artificial neural networks↗

Mitigating Green's function Monte Carlo signal-to-noise problems using contour deformations

The Green's function Monte Carlo (GFMC) method provides accurate solutions to the nuclear many-body problem and predicts properties of light nuclei starting from realistic two- and three-body interactions. Controlling the GFMC fermion sign problem is crucial, as the signal-to-noise ratio decreases exponentially with imaginary time, requiring significant computing resources. Inspired by similar scenarios in lattice quantum field theory and spin systems, in this work, we employ integration contour deformations to improve the GFMC signal-to-noise ratio. Machine learning techniques are used to select optimal contours with minimal variance from parametrized families of deformations. As a proof of principle, we consider the deuteron binding energies and Euclidean density response functions. Here, we only observe mild signal-to-noise improvement for the binding energy case. On the other hand, we achieve an order of magnitude reduction of the variance for Euclidean density response functions, paving the way for computing electron- and neutrino-nucleus cross sections of larger nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analog Quantum Simulation of the Dynamics of Open Quantum Systems with Quantum Dots and Microelectronic Circuits

We introduce a general setup for the analog quantum simulation of the dynamics of open quantum systems based on semiconductor quantum dots electrically connected to a chain of quantum RLC electronic circuits. The dots are chosen to be in the regime of spin-charge hybridization to enhance their sensitivity to the RLC circuits while mitigating the detrimental effects of unwanted noise. In this context, we establish an experimentally realizable map between the hybrid system and a qubit coupled to thermal harmonic environments of arbitrary complexity that enables the analog quantum simulation of open quantum systems. We assess the utility of the simulator by numerically exact emulations that indicate that the experimental setup can faithfully mimic the intended target even in the presence of its natural inherent noise. We further provide a detailed analysis of the physical requirements on the quantum dots and the RLC circuits needed to experimentally realize this proposal that indicates that the simulator can be created with existing technology. The approach can exactly capture the effects of highly structured non-Markovian quantum environments typical of photosynthesis and chemical dynamics, and offer clear potential advantages over conventional and even quantum computation. The proposal opens a general path for effective quantum dynamics simulations based on semiconductor quantum dots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-Noise Submillimeter-Wave Diode

Low noise achieved without usual high resistance. Barrier of p-type material placed between metal anode and heavily-doped gallium arsenide. Ntype epitaxial layer eliminated. Barrier prevents quantum tunneling of electrons between semiconductor and metal. Higher breakdown structure provided.

Mattauch, R. J.↗

Electron acoustic instabilities in the geomagnetic tail

Electron acoustic waves present in a two temperature electron plasma can be driven unstable when ion beams propagate along the magnetic field. Both linear theory and numerical simulations indicate that this instability contributes to the generation of broadband electrostatic noise (BEN) in the geomagnetic tail.

Ashour-Abdalla, M.↗

Numerical study of the spectrum of broadband electrostatic noise in the magnetotail

A numerical study of the spectrum of broadband electrostatic noise (BEN) generated by ion beams in the plasma sheet boundary layer (PSBL) is presented, in which two cases are analyzed. The first case is concerned with a single hot-electron species. In the second case, a second population of cold electrons (arising from diffusion from the lobe into the PSBL) is introduced. The presence of the second electron component in the dispersion relation for generating BEN was found to significantly increase the upper frequency range of the unstable spectrum, enhancing the associated growth rates. It is shown that ion beam instabilities can explain most major features of the observed BEN spectrum. The results explain the gradual rise in the upper frequency range of BEN as a spacecraft approaches the plasma sheet from the lobe, and the sudden jump in that frequency up to near the plasma frequency upon crossing the PSBL.

Grabbe, Crockett L.↗

Development of Numerical Models for Performance Predictions of Single-Photon Avalanche Photodetectors (SPAP) for the 2-Micron Regime

Field dependent drift velocity results are presented for electron transport in bulk Indium Arsenide (InAs) material based on a Monte Carlo model, which includes an analytical treatment of band-to-band impact ionization. Avalanche multiplication and related excess noise factor (F) are computed as a function of device length and applied voltage. A decrease in F with increases in device length is obtained. The results suggest an inherent utility for InAs-based single-photon avalanche detectors, particularly around the 2 microns region of interest for atmospheric remote sensing applications. The dark current response was also evaluated. The role of the various components has been analyzed. For shorter devices, the tunneling component is shown to dominate at low temperatures. Finally, possible structures for enhanced photodetection are proposed for future research.

Joshi, Ravindra P.↗