Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Multiple Stream Low-Cost Recycling Method

The global composite industry generates large quantities of waste and which mostly end as landfill due to lack of meaningful end-use applications for the multiple waste streams. In a recent report by the Electric Power Research Institute (EPRI), waste generated by the wind industry could reach 370,000 tons a year of composite wind energy blades being decommissioned and scrapped. Wind energy is just one major industry utilizing composite materials. The waste generated by industry includes End-of-Life (EoL) materials and manufacturing process scrap. GreenTex Solutions has developed a unique and innovative technology to recycle the composite waste streams in a range of forms made from production waste and EoL materials. This includes manufacturing waste materials such as dry chopped fiber tow, loose fibers, shredded fibers from reinforcement fabrics, cured/semi-cured prepregs, and it also includes fully-cured composite structure waste (such as edge trims from cured parts) from manufacturing aircraft, automobiles, wind blades, boats, and composite cylinders (tanks). Current recycling methods involve recovering the structural fiber by removing the matrix resin through methods such as pyrolysis. The resulting fibers are used in injection molding or wet laid nonwoven mats and other usable forms. The GreenTex technology bypasses these intermediate steps to create the lowest possible recycling processing costs and the lowest embodied energy/CO2 emissions. The end-product from the GreenTex technology is a finished industrial composite part/application versus intermediate fibers or fabrics. The GreenTex manufacturing process enables cross-industry reuse of recycled feedstock by taking waste from multiple industries (wind energy, aerospace, marine, etc.) and recycles the waste into a product used in other industries. The initial target market application is structural flooring for intermodal shipping containers and truck bodies. One of the team’s key partners is Wabash National which produced 29,000 truck bodies in 2019. The current flooring system is comprised of solid oak “butcher board” laminated panels. Additionally, Mediterranean Shipping Containers (MSC) transports over 1.8 million twenty-foot equivalent units per year in intermodal shipping containers. The current container floor is laminated hardwood that is harvested from the rain forests of Central and South America. The project is to develop a flooring system made from recycled composites that can be qualified for both companies (Wabash and MSC). Initial prototypes validated that the recycled composites panels are lighter and thinner with much higher mechanical strength. These results suggest a typical truck trailer would have 20% lower tare weight. The GreenTex technology is not limited to flooring and is widely applicable to other transportation elements such as walls, roof elements, cab areas and related structural components. Under this project different composite waste streams were evaluated and then combined to develop a formulation that would meet the targeted performance criteria for a flooring system. Wet compression molding was used to fabricate plaques at different tonnage using various composite waste streams. The plaques were tested for flexure and impact.

36 MATERIALS SCIENCE↗

Initial testing of wave energy powered UV-C LED anti-biofouling system (CRADA 523)

3newable is requesting technical assistance for laboratory testing at the Marine and Coastal Research (MCRL) Laboratory of a UV-C LED anti-biofouling system. Ocean observing sensors provide critical data sources from deployed buoys and other platforms at sea. However, in addition to the availability of reliable power sources, biofouling of sensors and instruments is a limiting factor for operation and maintenance of deployed instruments. In collaboration with the Woods Hole Oceanographic Institute Ocean Observatories Initiative, 3newable has developed a novel solution to overcome these challenges and extend the deployment period of buoy-mounted sensors. The 3newable system co-locates wave energy converters to supply UV-C LED anti-biofouling units on powered buoy arrays. MCRL staff will implement an experiment to evaluate the efficacy of 3newable’s device under test for inhibiting growth of organisms on test coupons in a flow through seawater tank.

42 ENGINEERING↗

Low-Cost Sulfur Thermal Storage for Increased Flexibility and Improved Economics of Fossil-Fueled Electricity Generating Units (Final Report)

The US electric grid relies on conventional fossil fuel power plants for reliable and secure power, but these plants suffer from physical and financial strain due to the influx of inexpensive and variable solar and wind electricity. Conventional power plants need to generate electricity flexibly and on-demand to accommodate these renewable resources on the grid. Integrating a low-cost thermal energy storage (TES) gives fossil assets the ability to regulate their output efficiently and optimize the plant operation to maximize revenue in the wholesale electricity market. Element 16’s TES concept uses sulfur, a byproduct of the oil & gas industry, as the storage media that is 10 times cheaper than molten salt used in commercial two-tank TES technology. In this project, the team completed a detailed feasibility and technoeconomic study establishing the impact, cost and performance of molten sulfur TES system integrated with fossil assets.

20 FOSSIL-FUELED POWER PLANTS↗

Methane Consuming Biocatalysts in Gas-Solid Reactor System

Carbon dioxide and methane are the two most abundant greenhouse gases with methane having a higher global warming potential (GWP) than carbon dioxide. Use of methanotrophs as a biocatalyst is a green alternative to chemical conversion of methane. Methanotrophs were immobilized in a 4-arm poly (-ethylene glycol)-tetra-acrylate, PEGTA, hydrogel that is supported by a 3D printed lattice containing micropores. The consumption rate of methane was 2.5 and 42 g CH 4 /L-hr in samples that were at 1 and 3 atm, respectively. A small increase in pressure of the system improves the consumption rate by almost 20x with minimal changes to the reactor system. This system relies on the mass transport of gas through a solid-like material rather than dissolving the gas in a liquid. Immobilization of cells in hydrogel allows for higher cell density and overall increased conversion rates compared to traditional stirred tank reactors. There are many other applications of the use of immobilized biological materials in polymers that require gas-phase reactions.

36 MATERIALS SCIENCE↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of HCanyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and Flow Properties of Glass Forming Chemicals (V2O5, SnO, SnO2, Cr2O3, FeCr2O4, and ZrSiO4) and Mixtures

For a sustainable nuclear waste vitrification process at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), proper selection and consistent supply of glass-forming chemicals (GFCs) are crucial. Establishing rigorous acceptance criteria for the characterization of GFCs will be required to operate the vitrification facility and to mitigate any processing issues or failures. Low-activity wastes (LAW) are blended with GFCs to form slurry melter feeds and vitrified in a melter. To enhance properties of waste glasses, new chemicals are being introduced to the current GFC mixture (Vienna et al. 2016; Muller et al. 2017, 2019). In this study, three new GFCs were evaluated for enhanced LAW glass formulations: chromium oxide (Cr 2 O 3 ), vanadium oxide (V 2 O 5 ), and stannic oxide (SnO 2 ). These three oxide components are included in enhanced waste glass (EWG) formulations and GFCs with the appropriate physical and flow properties are needed. As a starting point, single metal oxide GFCs: Cr 2 O 3 , V 2 O 5 , and SnO 2 were sourced and tested. To characterize these new individual GFCs and mixtures of GFCs, the industrial bulk characterization consultant, Jenike and Johanson, was employed to measure physical and flow properties of individual GFCs and their mixtures. Pacific Northwest National Laboratory (PNNL) also measured several selected physical properties for data evaluation as a quality assurance step. In addition, PNNL measured physical and rheological properties of slurry melter feeds containing those GFCs. Subsequent data analyses and verification were conducted. The purpose of this report is to assess the applicability of these GFCs for LAW vitrification based on their properties. This report will help understand measured data and evaluate new GFCs for use. Moreover, this report may give useful insights to help troubleshoot any GFC and melter feed transport and mixing issues that arise during processing, leading to a successful cleanup mission at WTP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Follow-On Status Report on FY2022 Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), compressed air energy storage (CAES), and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of High-deflection Foils for Marine Hydrokinetic Applications (Final Report)

This project used model-scale tank testing and fluid-structure-interaction (FSI) simulations to investigate the behavior of foils with large deflections and the effect of these deflections on crossflow turbine performance with the goal of determining the maximum allowable deflections consonant with efficiency and a robust, durable structure. A validated modeling and simulation approach was used in the design of an Ocean Renewable Power Company (ORPC) full-scale turbine. The methodology is applicable to the design of other marine hydrokinetic (MHK) devices, and to hydrokinetic turbines which experience significant deflections during operation.

16 TIDAL AND WAVE POWER↗

Strategies to Recover Easily-Extractable Rare Earth Elements and Other Critical Metals from Coal Waste Streams and Adjacent Rock Strata Using Citric Acid

Maximum rare earth element (REE) extractability from a sample of Middle Kittanning coal seam underclay was previously demonstrated at ~30% of the total REE content with a citric acid solution (Montross et al., 2020). This report further refines the mechanisms of citrate application for leaching of coal seam underclays using an organic acid lixiviant and evaluates strategies to begin to scale this process to industrially relevant volumes. This study evaluates the suitability of citrate leaching solutions for downstream recovery and separation of the REEs via oxalic acid precipitation. The applicability of citric acid solutions to recover ion-adsorbed metals from clay surfaces was evaluated by leaching a prepared sample of kaolinite with known amounts of ion-adsorbed lanthanum. Citrate systematics was further defined through experiments varying the solution pH. Up-scaling investigations proceeded with percolation leaching columns and stirred tank reactors. Two embodiments were run in percolation leaching: a continuous flow-through process and a multi-stage saturated process. The results showed that in certain limited scenarios, low pH citrate solutions could be used to target REEs mineralized within secondary calcium phosphate minerals. Results from the upscaling attempts encountered difficulties in extraction efficiencies. For the percolation columns, hydrodynamic flow was insufficient to recover the extractable REE content fully. For the stirred barrels, mixing inefficiencies likely inhibited the extractability of the REEs. Oxalic acid precipitation experiments also highlighted difficulties in downstream operations. The REEs were removed from the citrate solution with high efficiency, but were accompanied by equally efficient removal of calcium in orders of magnitude of greater amounts. Overall, for citrate leaching to be effective, future studies will have to: 1) carefully consider the feedstock application (i.e., likely better suited for secondary mineralization of calcium phosphate minerals), and 2) overcome the technical barriers of large-scale processing, such as inefficient hydrodynamic regimes due to small crush sizes needed and difficulties in downstream separation and purification. Alternatively, citrate solutions may be better recommended as leaching amendments to other leaching solutions to enhance REE complexation in the solution.

01 COAL, LIGNITE, AND PEAT↗

Quantification of Aerosol Transmission through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using more significant backfill pressures in the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Savannah River Site FY21 Salt Waste Qualification Data and Characterization Data from Salt Waste Batches Processed Since 2008

The Savannah River National Laboratory analyzed samples from Savannah River Site Waste Tank 41H and 21H to support qualification of Salt Waste Processing Facility Waste Batches 3 and 4 (the FY21 Salt Batch Qualification samples) for processing. Neither of the samples displayed any unusual or unexpected characteristics such as large amounts of solids, floating solids, or unusual color. Characterization of these samples confirmed similar chemical composition and characteristics to previous salt waste batches. These results were initially provided to Savannah River Remediation (Liquid Waste Operations Sub-contractor) as External Sample Results LIMS Reports. The analytical results (both expedited and routine) are now summarized and discussed in this technical report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FAST Equipment Lease with Liberty University, Inc. (Cooperative Research and Development Final Report)

Liberty University, Inc. (Participant) will receive government owned equipment from NREL to evaluate and perform fatigue testing of bladders in use for small scale pumped storage hydropower. NREL is providing technical support to advance Liberty University's pumped storage hydropower (PSH) concept towards commercialization. The concept creates modular upper and lower watertight enclosures (tanks or reservoirs) connected by a series of modular pipe lengths (penstock).

13 HYDRO ENERGY↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4-15.201- 2.1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Structural Rigidity Analysis of the NBSR DDE and the NBSR LEU Fuel Element

The National Bureau of Standards Reactor (NBSR) is a 20-MW heavy-water moderated and cooled, enriched-fuel, tank-type reactor located in the NIST Center for Neutron Research laboratory complex. NBSR is one of six U.S. high performance research reactors (USHPRR), including one critical facility, that actively collaborates with the National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program to convert from the use of highly enriched uranium fuel to the use of low-enriched uranium (LEU, < 20 wt% U-235) fuel. On the LEU U-10Mo fuel qualification side, mini-plate and large-plate irradiations have been successfully performed, and more experiments are either ongoing or planned. As an additional experimental campaign to support licensing of the LEU fuel for the use in the NBSR, the NBSR Design Demonstration Element (DDE) will be a full-sized test element similar to the NBSR LEU fuel element and irradiated in a test reactor under conditions as prototypic of the NBSR LEU fuel element operating conditions as possible.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FORCE-DISPATCHES Integration - Initial Demonstration

Integrated energy systems (IES) combine, in mutually beneficial ways, power from variable renewable energy sources and nuclear power plants (NPP) to improve economic viability under uncertain market and weather conditions. The open-source Framework for Optimization of Resources and Economics (FORCE) tool suite, developed at Idaho National Laboratory (INL), has enabled comprehensive modeling and simulation of IES. The capabilities within FORCE include grid portfolio optimization through the Holistic Energy Resource Optimization Network (HERON) and the transient process model analysis library HYBRID, among others. Continuous efforts and investments from the IES programs have been made to expand and improve the versatility of the FORCE toolset in fiscal year 2022. Code-coupling and cross-tool communication have been important methods for improving this versatility. This report focuses on an additional workflow in the HERON tool for capacity and dispatch stochastic optimization through integration with the external tool Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES). DISPATCHES was primarily developed by the National Energy Technology Laboratory, in collaboration with other national laboratories, which included INL, universities, and industry partners. It is coupled to a library of algebraic models for specific plant components, and to a framework for stochastic optimization different from that provided in the current Risk Analysis Virtual Environment (RAVEN)-running-RAVEN algorithm in HERON. HERON currently conducts stochastic optimization via an outer-inner loop: it optimizes over variable capacity on the outer loop, and at each step within the capacity parameter space, conducts an inner optimization over scenarios (of market signals, demand, and/or weather patterns) and hourly dispatch throughout a user-specified number of years. On the other hand, DISPATCHES conducts stochastic optimization via an “all-at-once” strategy in which capacity variables are optimized at the same level as dispatch variables, as all scenarios are considered at once. The latter method works especially well for projects of limited size and project length, as the necessary computational power and memory increases with the number of variables and scenarios. The new capability to use the DISPATCHES workflow in HERON enhances standalone simulations by leveraging FORCE tools—namely, the economic metrics from the Tool for Economic Analysis (TEAL) and reduced-order model (ROM) sampling from RAVEN. The initial demonstration of the DISPATCHES workflow simulates an existing nuclear-case flowsheet within the DISPATCHES repository—this models a NPP with a secondary revenue stream for hydrogen production. Electrical output from the plant is converted to hydrogen via a proton-exchange membrane (PEM) electrolyzer, hydrogen tanks are used for storage, and an additional turbine is added for hydrogen combustion. Continued work regarding this FORCE-DISPATCHES integration will include automatic generation of DISPATCHES models from HERON inputs, offering analysts the option of using either the RAVEN-runsRAVEN or DISPATCHES workflow to solve technoeconomic optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗