Computer model of a field ion source
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The original 12 cm hexagonal magneto-electrostatic containment (MESC) discharge chamber described by Moore in 1969 has been optimized for argon and xenon operation. Argon mass utilization efficiencies of 65 to 77 percent were achieved at keeper-plus-main discharge energy consumptions of 244 to 422 eV/ion respectively. Xenon performance of 85 to 96 percent mass utilization were realized at 203 to 350 eV/ion. The paper discusses the optimization process and test results.
THe original 12 cm hexagonal magneto-electrostatic containment discharge chamber has been optimized for argon and xenon operation. Argon mass utilization efficiencies of 65 to 77 percent were achieved at keeper-plus-main discharge energy consumptions of 200 to 458 eV/ion, respectively. Xenon performance of 84 to 96 percent mass utilization was realized at 203 to 350 eV/ion. The optimization process and test results are discussed.
The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.
Explore the source record for details and available documents.
Movable probe and tuning wall adjusted to obtain resonance at microwave frequency used to generate plasma in cell at one end of microwave cavity. Electroless discharge without disadvantages of dc-cathode-discharge and RF-induction methods. To achieve precise positioning, coaxial probe extends into microwave cavity through tube.
Explore the source record for details and available documents.
We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.
Explore the source record for details and available documents.
The Ion Beam Experiment at the Center for Astrophysics is dedicated to the study of ion-electron collision processes of importance in solar physics. A paper describing our most recent measurement 'Absolute cross section for Si(2+)(3s3p(sup 3)Rho (sup 0) yields 3s3p(sup 1)Rho(sup 0)) electron-impact excitation' was published during the past year. Dr. Paul Janzen received his PhD. from the Harvard Physics Department on the basis of this and other work, such as the new electron cyclotron resonance (ECR) ion source. The ion source is producing stable beams with large currents for our present work on C(2+), and it also produces stable beams with large currents of more highly charged systems, for future work on systems such as O(4+). The past year has been focussed on our current program to measure absolute cross sections for Electron Impact Excitation (EIE) in C(2+), one of the primary ions used for probing the solar transition region. C(2+) beams produced by the ion source have been transported to the interaction region of the experiment, where the collisions are studied, and Visiting Scientist Dr. Adrian Daw is currently collecting data to measure the C(2+)(2s2p(sup 3)Rho(sup 0) yields 2p(sup 2)(sup 3)Rho) EIE cross section as a function of collision energy, under the guidance of Drs. John Kohl, Larry Gardner and Bill Parkinson. Also this year, modifications were made to the ECR ion source in order to produce greater currents of highly charged ions. Testing of the ion source was completed. Modifications were designed to extend the photon detection capabilities of the apparatus to shorter UV wavelengths, or EUV. Following the work on C(2+)(2s2p(sup 3)Pho(sup 0) yields 2p(sup 2)(sup 3)Rho), the extended UV detection capabilities will be used to measure the C(2+)(2s(sup 2)(sup 1)S yields 2s2p(sup 1)Rho(sup 0)) EIE cross section. The EUV modifications complement those of the new ion source, by enabling detection of EUV light generated by high charge state ions and putting us in a position to measure the excitation cross sections for more highly charged ions as well.
Results are given for ion beam texturing of polyimide (Kapton) and fluorinated ethylene propylene (Teflon) by means of a 30-cm diam electron bombardment argon ion source. Ion beam-textured Kapton and Teflon surfaces are evaluated for various beam energies, current densities, and exposure times. The optical properties and sheet resistance are measured after each exposure. Provided in the paper are optical spectral data, resistivity measurements, calculated absorptance and emittance measurements, and surface structure SEM micrographs for various exposures to argon ions. It is found that Kapton becomes conducting and Teflon nonconducting when ion beam-textured. Textured Kapton exhibits large changes in the transmittance and solar absorptance, but only slight changes in reflectance. Surface texturing of Teflon may allow better adherence of subsequent sputtered metallic films for a high absorptance value. The results are valuable in spacecraft charging applications.
A 30-cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cu cm at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of + or - 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity.
Sputter ion source mass spectrometer for analysis of solid materials
The Ion Beam Propulsion Study was a joint high-level study between the Applied Physics Laboratory operated by NASA and ASRC Aerospace at Kennedy Space Center, Florida, and Berkeley Scientific, Berkeley, California. The results were promising and suggested that work should continue if future funding becomes available. The application of ion thrusters for spacecraft propulsion is limited to quite modest ion sources with similarly modest ion beam parameters because of the mass penalty associated with the ion source and its power supply system. Also, the ion source technology has not been able to provide very high-power ion beams. Small ion beam propulsion systems were used with considerable success. Ion propulsion systems brought into practice use an onboard ion source to form an energetic ion beam, typically Xe+ ions, as the propellant. Such systems were used for steering and correction of telecommunication satellites and as the main thruster for the Deep Space 1 demonstration mission. In recent years, "giant" ion sources were developed for the controlled-fusion research effort worldwide, with beam parameters many orders of magnitude greater than the tiny ones of conventional space thruster application. The advent of such huge ion beam sources and the need for advanced propulsion systems for exploration of the solar system suggest a fresh look at ion beam propulsion, now with the giant fusion sources in mind.
A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamondlike films generated by sputtering a graphite target.
A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamond like films generated by sputtering a graphite target.