108 records · Page 6

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Templates for Risk Informed Assurance with Curvature Embeddings (TRACE)

We investigate recovery of geometric structure from networks embedded in manifolds with spatially varying curvature, extending the constant-curvature framework of Lubold et al. (2023). Our work supports cascade risk assessment in critical infrastructure through the Templates for Risk-informed Assurance with Curvature Embeddings (TRACE) framework. Simulations on a bi-modal Gaussian surface show that constant-curvature methods yield weighted averages shaped by clique patterns, while hierarchical clustering identifies distinct regimes. Localized estimation, however, reveals boundary contamination in transitional regions. To address heterogeneity, we develop distance metrics for graphs with edge and node features, proving their metric validity, and validate them via deterministic graph generation from canonical tilings. We further propose a diffusion-based anomaly detection approach that treats networks as glued manifolds, using curvature discontinuities to detect structural anomalies. Employing the carré-du-champ operator and scalar curvature, we achieve robust anomaly discrimination, demonstrated on the Singapore Water Treatment (SWaT) dataset with joint network-traffic and sensor features. Integration with TRACE reveals how curvature shapes cascade dynamics: positive curvature impedes, while negative curvature accelerates propagation. This geometric perspective provides interpretable risk metrics and visualization tools for critical infrastructure managers. While full validation remains ongoing, our contributions establish a rigorous foundation for geometric analysis of network resilience and cascade vulnerability.

97 MATHEMATICS AND COMPUTING↗

Monitoring installation of partially occluded subassemblies in modular construction factories using BIM, ray tracing, and computer vision

Modular and offsite construction methods are being increasingly adopted due to the advantages they offer in terms of project completion time, quality, and energy-efficiency. Despite these advantages, the current state of monitoring systems in modular construction factories highly relies on labor-intensive, subjective, and error-prone observational methods. A large body of research has aimed to automate the monitoring process using an array of sensors, such as IMUs and RFIDs, during the past two decades. Recently, computer vision-based methods have gained increasing interest as a non-intrusive technology to monitor the process inside modular construction factories. However, partial occlusion challenges have impeded their practical application on a large scale. This challenge is specifically important for monitoring the installation of subassemblies since they can obstruct the view of the monitoring camera, especially those that enable long-term monitoring like closed-circuit television (CCTV) fixed-view surveillance cameras. Here, this paper aims to address this challenge by proposing a novel computer vision-based method to monitor the installation of new subassemblies inside modular factories in highly occluded scenes. The proposed methodology identifies the subassemblies in the CCTV video footage using computer vision, analyzes the occlusions using BIM and ray casting techniques, and estimates the progress of assembly by comparing the BIM model with the detected subassemblies in the video. The proposed methodology was successfully validated on surveillance videos captured from a volumetric modular construction factory in the U.S., achieving 93% accuracy in identifying the installation of subassemblies. The results from this research show that the integration of BIM and computer vision is a promising method for monitoring the installation processes inside modular factories under severe occlusion.

97 MATHEMATICS AND COMPUTING↗

Mass transfer in catalytic depolymerization: External effectiveness factors and serendipitous processivity in stagnant and stirred melts

Several heterogeneous catalysts are being developed to recycle plastics. Most operate in viscous polymer melts, where external mass transfer effects could limit the supply of co-reactants to active sites. External mass transfer can also impede the diffusion of long chain products away from the catalyst after each cut. Product egress limitations could potentially confer unintentional processivity to catalyst operation, i.e. a tendency for the catalyst to repeatedly cut the same chain after an initial encounter. We formulate reaction–diffusion equations to quantify mass transfer effects on the co-reactant transport to the catalyst and the degree of serendipitous processivity. Results are developed for catalysts in stagnant or stirred melts, with simple expressions involving Damkohler, Peclet, and Sherwood numbers, i.e. dimensionless combinations of rate constants, catalyst particle size, polymer diffusivities, and shear rates (where applicable). In conclusion, we estimate the impact of these effects for a spherical core–shell catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast-RF-Shimming: Accelerate RF shimming in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) offers an elevated signal-to-noise ratio (SNR), enabling exceptionally high spatial resolution that benefits both clinical diagnostics and advanced research. However, the jump to higher fields introduces complications, particularly transmit radiofrequency (RF) field ($B^{+}_{1}$) inhomogeneities, manifesting as uneven flip angles and image intensity irregularities. These artifacts can degrade image quality and impede broader clinical adoption. Traditional RF shimming methods, such as Magnitude Least Squares (MLS) optimization, effectively mitigate $B^{+}_{1}$ inhomogeneity, but remain time-consuming. Recent machine learning approaches, including RF Shim Prediction by Iteratively Projected Ridge Regression and other deep learning architectures, suggest alternative pathways. Although these approaches show promise, challenges such as extensive training periods, limited network complexity, and practical data requirements persist. In this paper, we introduce a holistic learning-based framework called Fast-RF-Shimming, which achieves a 5000 ​× ​speed-up compared to the traditional MLS method. In the initial phase, we employ random-initialized Adaptive Moment Estimation (Adam) to derive the desired reference shimming weights from multi-channel $B^{+}_{1}$ fields. Next, we train a Residual Network (ResNet) to map $B^{+}_{1}$ fields directly to the ultimate RF shimming outputs, incorporating the confidence parameter into its loss function. Finally, we design Non-uniformity Field Detector (NFD), an optional post-processing step, to ensure the extreme non-uniform outcomes are identified. Comparative evaluations with standard MLS optimization underscore notable gains in both processing speed and predictive accuracy, which indicates that our technique shows a promising solution for addressing persistent inhomogeneity challenges.

Deep learning↗

Designing multicomponent hydrides with potential high T c superconductivity

While hydrogen-rich materials have been demonstrated to exhibit high T c superconductivity at high pressures, there is an ongoing search for ternary, quaternary, and more chemically complex hydrides that achieve such high critical temperatures at much lower pressures. First-principles searches are impeded by the computational complexity of solving the Eliashberg equations for large, complex crystal structures. Here, we adopt a simplified approach using electronic indicators previously established to be correlated with superconductivity in hydrides. This is used to study complex hydride structures, which are predicted to exhibit promisingly high critical temperatures for superconductivity. In particular, we propose three classes of hydrides inspired by the Fm$\overline{3}$ m RH 3 structures that exhibit strong hydrogen network connectivity, as defined through the electron localization function. The first class [RH 11 X 3 Y] is based on a Pm$\overline{3}$m structure showing moderately high T c , where the T c estimate from electronic properties is compared with direct Eliashberg calculations and found to be surprisingly accurate. The second class of structures [(RH 11 ) 2 X 6 YZ] improves on this with promisingly high density of states with dominant hydrogen character at the Fermi energy, typically enhancing T c . The third class [(R 1 H 11 )(R 2 H 11 )X 6 YZ] improves the strong hydrogen network connectivity by introducing anisotropy in the hydrogen network through a specific doping pattern. These design principles and associated model structures provide flexibility to optimize both T c and the structural stability of complex hydrides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute contrast estimation for soft X-ray photon fluctuation spectroscopy using a variational droplet model

Abstract X-ray photon fluctuation spectroscopy using a two-pulse mode at the Linac Coherent Light Source has great potential for the study of quantum fluctuations in materials as it allows for exploration of low-energy physics. However, the complexity of the data analysis and interpretation still prevent recovering real-time results during an experiment, and can even complicate post-analysis processes. This is particularly true for high-spatial resolution applications using CCDs with small pixels, which can decrease the photon mapping accuracy resulting from the large electron cloud generation at the detector. Droplet algorithms endeavor to restore accurate photon maps, but the results can be altered by their hyper-parameters. We present numerical modeling tools through extensive simulations that mimic previous x-ray photon fluctuation spectroscopy experiments. By modification of a fast droplet algorithm, our results demonstrate how to optimize the precise parameters that lift the intrinsic counting degeneracy impeding accuracy in extracting the speckle contrast. These results allow for an absolute determination of the summed contrast from multi-pulse x-ray speckle diffraction, the modus operandi by which the correlation time for spontaneous fluctuations can be measured.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Searching for a Pulse: Evaluating the Use of Rapid DC Pulses for Diagnosing Battery Health, State-of-Charge, and Safety

Rapid electrochemical diagnostics, like DC pulse sequences or electrochemical impedance spectroscopy, are known to be useful for capacity prediction. However, it is unclear how previous results will map to different cell types and use cases and whether rapid diagnostics are useful for remaining useful life prediction or for detecting potential safety issues. To that end, we have collected a data set with ∼50,000 DC pulse measurements from four types of commercial lithium-ion batteries to enable training of state-of-charge, health, and safety diagnostic models via machine-learning. We demonstrate that 120-second DC pulse sequences can be used to predict capacity with 2%–9% average error, which can separate high- from low-capacity cells with only a 0.3% false positive rate but is not accurate enough to estimate remaining useful life. We also find that no safety related targets can be accurately predicted, highlighting the critical need for other non-invasive methods to diagnose battery safety.

25 ENERGY STORAGE↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of a Cobalt-Containing Interphase at the Li 6 PS 5 Cl-NMC111 Interface by In Situ μ XANES and EIS

Sulfide electrolyte all-solid-state lithium batteries (ASLBs) with uncoated Li-Ni x Mn y Co 1–x–y O 2 (NMC) cathodes suffer from a large capacity loss during initial cycling and an increase in cell impedance. Decomposition reactions are known to occur at the Li 6 PS 5 Cl-NMC111 interface due to incompatibility between the two materials. If a stabilizing coating is applied to the NMC, it delivers full capacity during initial charge. However, the loss in capacity during discharge still occurs. The interface was studied by μ XANES and through EIS analysis. A chemically-formed interphase was detected by μ XANES, evident from reduction of Co at an uncoated NMC particle surface. This interphase was produced by decomposition at rest. To study the effect of the interphase on electrochemically active surface area, piecewise in situ EIS was performed and the data was modeled using a transmission line model (TLM). The charge transfer resistance R CT was used to estimate the volume specific active surface area (a act ). The median value for a act was 296 cm –1 , a factor of 7.5 lower than the theoretical value of 2216 cm –1 . This provided evidence of a lower electrochemically active surface area in the ASLB.

36 MATERIALS SCIENCE↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

3D Frequency Domain Reflectometry Digital Twin of an Electrical Cable: A First Glance

Electrical cables within nuclear power plants (NPPs) are critical components required for power, control, and instrumentation systems which may be exposed to stressors, such as elevated temperatures and gamma radiation. Such stressors can lead to a reduction in the remaining useful life of electrical cables, jeopardizing the safety of NPP systems. To evaluate the effect of stressors on the degradation of electrical cables, electrical reflectometry methods are commonly employed. Frequency domain reflectometry (FDR) is a non-destructive electrical reflectometry method that uses transmission line theory to detect degradation or impedance changes within electrical cables. However, in most cases FDR is only applied to de-energized cables, limiting the application in NPPs as the cable system must be taken offline. In this work, we explore the development of an FDR digital twin to predict the degradation of an electrical cable exposed to elevated temperature, which is expected to reduce the need for offline FDR. A 3-conductor low-voltage electrical cable was selected for evaluation of the digital twin. The fully three-dimensional digital twin was developed in COMSOL using the RF module. A cable length of 30-m and frequency bandwidth of 400 MHz was selected to mimic real-world application of FDR. Over a 1-m region, the permittivity of the insulation was varied by up to 20% to model thermal degradation. The results demonstrate accurate detection of the insulation damage region, supporting further investigation of the FDR digital twin using real-world data and machine learning for predictive damage estimation or remaining lifetime.

Spencer, Mychal P.↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

Internal 2-D Surface Temperature Measurements for Large Complex Geometries

For 2D-temperature monitoring applications, a variant of EIT (Electrical Impedance Tomography) is evaluated computationally in this work. Literature examples of poor sensor performance in the center of the 2D domains away from the side electrodes motivated this study which seeks to overcome some of the previously noted shortcomings. In particular, the use of ‘sensing skins’ with novel tailored baseline conductivities were examined using the EIDORS package for EIT. It was found that the best approach for detecting a hot spot depends on several factors such as the current injection (stimulation) patterns, the measurement patterns, and the reconstruction algorithms. For a well-performing combination of these factors, tailored baseline conductivities were assessed and compared to the baseline uniform conductivity. It was discovered that for some EIT applications, a tailored distribution needs to be smooth and that sudden changes in the conductivity gradients should be avoided. Still, the benefits in terms of improved EIT performance were small for conditions for which the EIT measurements had been ‘optimized’ for the uniform baseline case. Within the limited scope of this study, only two specific cases showed benefits from tailored distributions. For one case, a smooth tailored distribution with increased baseline conductivity in the center provided a better separation of two centrally located hot spots. For another case, a smooth tailored distribution with reduced conductivity in the center provided better estimates of the magnitudes of two hot spots near the center of the sensing skin.

47 OTHER INSTRUMENTATION↗

Extending water vapor measurement capability of photon-limited differential absorption lidars through simultaneous denoising and inversion

Abstract. The micropulse differential absorption lidar (MPD) was developed at Montana State University (MSU) and the National Center for Atmospheric Research (NCAR) to perform range-resolved water vapor (WV) measurements using low-power lasers and photon-counting detectors. The MPD has proven to produce accurate WV measurements up to 6 km altitude. However, the MPD's ability to produce accurate higher-altitude WV measurements is impeded by the current standard differential absorption lidar (DIAL) retrieval methods. These methods are built upon a fundamental methodology that algebraically solves for the WV using the MPD forward models and noisy observations, which exacerbates any random noise in the lidar observations. The work in this paper introduces the adapted Poisson total variation (PTV) specifically for the MPD instrument. PTV was originally developed for a ground-based high spectral resolution lidar, and this paper reports on the adaptations that were required in order to apply PTV on MPD WV observations. The adapted PTV method, coined PTV-MPD, extends the maximum altitude of the MPD from 6 to 8 km and substantially increases the accuracy of the WV retrievals starting above 2 km. PTV-MPD achieves the improvement by simultaneously denoising the MPD noisy observations and inferring the WV by separating the random noise from the non-random WV. An analysis with 130 radiosonde (RS) comparisons shows that the relative root-mean-square difference (RRMSE) of WV measurements between RS and PTV-MPD exceeds 100 % between 6 and 8 km, whereas the RRMSE between RS and the standard method exceeds 100 % near 3 km. In addition, we show that by employing PTV-MPD, the MPD is able to extend its useful range of WV estimates beyond that of the ARM Southern Great Plains Raman lidar (RRMSE exceeding 100 % between 3 and 4 km); the Raman lidar has a power-aperture product 500 times greater than that of the MPD.

54 ENVIRONMENTAL SCIENCES↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗