Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high-temperature testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mechanical characterization of Bi-2212 composite winding pack samples for high-field superconducting magnet design

Bi₂Sr₂CaCu₂O8−x (Bi-2212) multi-filament round wire is a high-temperature superconductor (HTS) capable of carrying high transport currents, which makes it suitable for high-field magnet applications. However, its weak Ag–Mg sheath leaves it vulnerable to mechanical stress, posing challenges for high-field magnet design. To better understand and improve mechanical stress management in Bi-2212 winding packs, we conducted an experimental study evaluating the axial stress–strain behavior of five winding pack configurations with varying insulation materials, reinforcement strategies, and construction quality. Using uniaxial tensile testing at 77 K, we measured Young’s modulus and Poisson’s ratio for each composition. Our results show that pure alumina braid insulation and co-wind reinforcements significantly enhance stiffness compared to aluminosilicate braids, with more than 2.5 times increased winding pack Young’s modulus. Rule of mixtures analysis further quantified the contribution of non-wire composite components to overall stiffness. These findings highlight the critical role of insulation material selection and reinforcement design in optimizing Bi-2212 coil performance under stress, providing a foundation for improved mechanical models and more reliable high-field HTS magnet designs.

Bi-2212 magnet↗

(Ir)Relevance of Disorder for Superconductivity in Cuprates

In cuprates that exhibit high-temperature superconductivity (HTS), as the doping level 𝑝 is increased beyond the optimal value, the superfluid density 𝑛 𝑠⁢0 decreases and eventually vanishes, closely tracking the critical temperature 𝑇 𝑐 . This has been interpreted using a dirty-𝑑-wave extension of the Bardeen-Cooper-Schrieffer theory, assuming that 𝑇 𝑐 and 𝑛 𝑠⁢0 decrease with increasing disorder and pair breaking. Here, to test this hypothesis, we tuned the doping level in overdoped La 2-x ⁢Sr x ⁢CuO 4−𝛿 films by electrolyte gating, measured several parameters used to quantify the level of disorder (the residual resistivity ratio RRR, the mean free path 𝑙 0 , and the electron mobility 𝜇), and studied how 𝑇 𝑐 and 𝑛 𝑠⁢0 scale with these. The experimentally measured dependence turned out to be the opposite of the expected—𝑇 𝑐 and 𝑛 𝑠⁢0 increased with increasing disorder. This brings the question of the true origin of the demise of 𝑇 𝑐 and 𝑛 𝑠⁢0 with overdoping back to the center stage of the quest to decipher the HTS enigma.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Performance of a Conduction-Cooled CCT Dipole ReBCO Magnet: Several Cycles of Cool-Down and Thermal Gradient Measurements

Here, this paper presents experimental results from conduction-cooled thermal testing of a ReBCO canted cosine theta (CCT) magnet (C2), originally designed and fabricated at LBNL using CORC cables. While the performance of the coil under liquid helium and nitrogen environments has been previously established, this study explores its behavior under conduction cooling using a large test cryostat at The Ohio State University. The magnet, measuring 613 mm in length and weighing ∼75 kg, consists of four helical layers wound with ReBCO-based CORC wire and was thermally anchored to a copper cold ring supported by a G-10 strongback. Cooling was provided by two Sumitomo RDK-415D cryocoolers, offering a combined 3 W at 4.2 K and 150 W at 77 K. Multiple thermal cycles were performed, with cooldown durations of up to 45 hours. Final base temperatures of approximately 10.8 K (at the coil edge) and 12.0 K (at the coil center) were achieved, with an axial temperature difference of approximately 1.2 K. The warm-up period extended over approximately 24.6 hours. Voltage measurements from all four layers were recorded during cooldown and warmup. The system demonstrated stable cooldown performance, repeatable gradients, and good thermal anchoring. These results support the feasibility of conduction cooling in large-scale HTS magnets, aligning with broader goals for “green” cryogen-free accelerator technologies and paving the way for more sustainable, scalable, and energy-efficient high-field magnet systems in next-generation particle accelerators.

Canted cosine theta magnets↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Manufacturability and performance response of developed Ni-based alloys for reactor environments

Under the Advanced Materials and Manufacturing Technologies program, two Ni-based alloys fabricated by laser powder bed fusion (LPBF) at Oak Ridge National Laboratory and by laser powder directed energy deposition (LP-DED) at Idaho National Laboratory have been evaluated: γ′-strengthened Haynes 282 and solution-strengthened Inconel 625. Printing defects were observed in the LPBF 282 alloy fabricated using a Renishaw AM250 machine, likely due to particle spattering during printing. For both the LPBF and LP-DED 282 alloys, annealing at 1,180°C for 1 h resulted in partial recrystallization and a bimodal grain distribution, and subsequent aging for 4 h at 800°C led to the formation of a high density of nano-size γ′-strengthening precipitates. Creep testing performed at 750°C revealed lower creep life and ductility for the LPBF and LP-DED 282 compared with wrought 282. X-ray computed tomography combined with optical and scanning electron microscopy microstructural characterization revealed crack formation in the LPBF 282 alloy during creep testing, initiated either from printing defects or from creep cavitation at grain boundaries. Creep cavitation and cracking at grain boundaries were also observed for the LP-DED 282 alloy, and optimization of the printing strategies and postheat treatments will be needed to fabricate high-performance 282 components for high-temperature nuclear applications.

36 MATERIALS SCIENCE↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

Evaluating Lithium-Lead Mixtures for Increased Tritium Breeding in Fusion Energy Blanket Systems: Exploring the Impact of Composition and Temperature

This project investigates hypo- and hyper-eutectic liquid lithium-lead (PbLi) mixtures as a coolant in fusion blanket systems, with a focus on testing the compatibility of compositions with better tritium breeding ratios (TBR). The 12-month study concentrates on static corrosion experiments, comparing silicon carbide (SiC) corrosion rates in Li-rich and eutectic Li-Pb mixtures, and examining interactions between Mo and PbLi. The research seeks to determine the maximum operating temperatures for this material combination, acknowledging the balance between Li-Pb melting temperature and achievable TBR to unlock new opportunities for blanket design. This work lays the groundwork for future collaboration between Kyoto Fusioneering and Oak Ridge National Laboratory (ORNL). Findings could enhance the TBR of fusion blanket designs, and impact fusion energy development by confirming material compatibility between different Li-Pb mixtures with SiC and Mo at higher temperatures, including at temperatures relevant for very high-temperature blankets (1,000 °C), which could enable higher electricity conversion efficiencies and commercial applications using process heat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and Evaluation of Large Alumina Crucibles by Vat Photopolymerization Additive Manufacturing for High-Temperature Actinide Chemistry

Additive manufacturing (AM) offers opportunities to advance the design and function of ceramic tooling in high temperature actinide pyrochemistry. In technical ceramics such as alumina, conventional forming techniques often restrict design flexibility and can limit experimental progress. In this study, we investigate the use of vat photopolymerization (VP) with commercial resins to fabricate large-scale alumina crucibles, reaching dimensions up to 125 mm, which is significantly larger than typically reported for dense VP ceramics. Notably, these additively manufactured components are produced using consumer-grade hardware, which limits process control, but offers significant upside in scalability and accessibility. Using microscopy and X-ray computed tomography, the VP alumina parts have high bulk densities above 95%, but also the prevalence of AM-induced artifacts and surface defects. Mechanical testing showed these defects to significantly reduce flexural strength and compromise part reliability. Electrorefining trials under sustained exposure to molten salts and metals reveal mixed results, with the AM material exhibiting high chemical compatibility, but mechanical failures due to the reduced strength were prevalent. Our findings illustrate both the promise and current limitations of AM ceramics for actinide chemistry, and point toward future improvements in process optimization, design strategies, and part screening to enhance performance and reliability.

Materials science↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

Elastic Modulus Measurement at High Temperatures for Miniature Ceramic Samples Using Laser Micro-Machining and Thermal Mechanical Analyzer

In this paper, we demonstrate a method of measuring the flexural elastic modulus of ceramics at an intermediate (~millimeter) scale at high temperatures. We used a picosecond laser to precisely cut microbeams from the location of interest in a bulk ceramic. They had a cross-section of approximately 100 μm × 300 μm and a length of ~1 cm. They were then tested in a thermal mechanical analyzer at room temperature, 500 °C, 800 °C, and 1100 °C using the four-point flexural testing method. We compared the elastic moduli of high-purity Al2O3 and AlN measured by our method with the reported values in the literature and found that the difference was less than 5% for both materials. This paper provides a new and accurate method of characterizing the high-temperature elastic modulus of miniature samples extracted from representative/selected areas of bulk materials.

Chemistry↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗