Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “component degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Operation Optimization Using Reinforcement Learning with Integrated Artificial Reasoning Framework

In large and complex systems, operational decision-making requires a systematic analysis with a vast amount of data from both process parameters and component status monitoring. In this paper, we present an integrated artificial reasoning approach for system state transition models that can help operational decision-making with explainable and traceable reasoning. The integrated artificial reasoning framework is a physics-based approach of defining the system structure in a Bayesian network, so we leveraged it in a Markov decision process (MDP) for finding optimal operational solutions. In our proposed framework, the MDP is implemented on a dynamic Bayesian network (DBN), which represents causalities in a system. The multilevel flow modeling was utilized in order to extract these causalities in a more efficient and objective manner. Since multilevel flow modeling is based on the fundamental energy and mass conservation laws, the target system is decomposed into several mass, energy, and information structures, which serve as the basis for a DBN. The MDP consists of the processes of finding a solution for the Bellman equation, which can be derived from the conditional probability equations of the constructed DBN. System operators can capture stochastic system dynamics as multiple subsystem state transitions based on their physical relations and uncertainties coming from the component degradation process or random failures. We analyzed a simplified example system to illustrate finding an optimal operational policy with this approach.

Kim, Junyung↗

Ultrasonic imaging in liquid sodium

The fourth generation of nuclear reactor can use liquid sodium as the core coolant. When the reactor is operating, sodium temperatures can reach up to 600 deg. C. During maintenance periods, when the reactor is shut down, the coolant temperature is reduced to 200 deg. C. Because molten sodium is optically opaque, ultrasonic imaging techniques are developed for maintenance activities. Under-sodium imaging aims at i) checking the health of immersed structures. It should also allow ii) to assess component degradation or damage as cracks and shape defects as well as iii) the detection of lost objects. The under-sodium imaging system has to sustain high temperature (up to 300 deg. C) and hostility of the sodium environment. Furthermore, specific constraints such as transducers characteristics or the limited sensor mobility in the reactor vessel have to be considered. This work focuses on developing a methodology for detecting damages such as crack defects with ultrasound devices. Surface-breaking cracks or deep cracks are sought in the weld area, as welds are more subject to defects. Traditional methods enabled us to detect emerging cracks of submillimeter size with sodium-compatible high-temperature transducer. The presented approach relies on making use of prior knowledge about the environment through the implementation of differential imaging and time-reversal techniques. Indeed, this approach allows to detect a change by comparison with a reference measurement and by focusing back to any change in the environment. It is a means of analysis and understanding of the physical phenomena making it possible to design more effective inspection strategies. Difference between the measured signals reveals the acoustic field scattered by a perturbation (a crack for instance), which may occur between periodical measurements. The imaging method relies on the adequate combination of two computed ultrasonic fields, one forward and one adjoint. The adjoint field, which carries the information about the defects, is analogous to a time-reversal operation. One of the interests of the presented method is that the time-reversal operation is not done experimentally but numerically. Numerical simulations have been carried out to validate the practical relevance of this approach. The preliminary numerical results show a nice agreement between the guessed and the actual positions of the defect. After water-tests, in sodium-tests must be done in order to validate the water/sodium transposition. For this purpose, an under-sodium device is under development, which can move the transducers with four degrees of freedom in a 1.5 m{sup 3} sodium pot. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ADVANCED NDE TECHNOLOGIES FOR DETECTING AND MANAGING AGING AND DEGRADATION IN REACTOR COMPONENTS

Recent research in nuclear power reactors has focused on the development and deployment of technologies for improving the economics of nuclear power plant (NPP) operation. Of interest, both from an economic and safety perspective, is the management and mitigation of aging-related degradation in critical components. In this paper, we describe potential techniques for nondestructive evaluation (NDE) that may be adapted for online monitoring of component aging in advanced non-light water reactors (ANLWR). The implications of the operating environment on the NDE measurement, especially when conducted continuously with the sensor placed in situ, are described. The design of sensors that can be used for monitoring component aging in situ and online are discussed, and results from laboratory testing at elevated temperature are outlined. Laboratory testing indicates the sensor can survive the operating temperatures in ANLWRs while providing a reasonable measurement signal-to-noise ratio. Ongoing research is focused on further testing and refining the sensor design and measurement procedures for deployment in ANLWR environments.

Ramuhalli, Pradeep↗

Degradation mechanisms and accelerated testing in PEM fuel cells

The durability of PEM fuel cells is a major barrier to the commercialization of these systems for stationary and transportation power applications. Although there has been recent progress in improving durability, further improvements are needed to meet the commercialization targets. Past improvements have largely been made possible because of the fundamental understanding of the underlying degradation mechanisms. By investigating component and cell degradation modes; defining the fundamental degradation mechanisms of components and component interactions new materials can be designed to improve durability. Various factors have been shown to affect the useful life of PEM fuel cells. Other issues arise from component optimization. Operational conditions (such as impurities in either the fuel and oxidant stream), cell environment, temperature (including subfreezing exposure), pressure, current, voltage, etc.; or transient versus continuous operation, including start-up and shutdown procedures, represent other factors that can affect cell performance and durability. The need for Accelerated Stress Tests (ASTs) can be quickly understood given the target lives for fuel cell systems: 5000 hours ({approx} 7 months) for automotive, and 40,000 hrs ({approx} 4.6 years) for stationary systems. Thus testing methods that enable more rapid screening of individual components to determine their durability characteristics, such as off-line environmental testing, are needed for evaluating new component durability in a reasonable turn-around time. This allows proposed improvements in a component to be evaluated rapidly and independently, subsequently allowing rapid advancement in PEM fuel cell durability. These tests are also crucial to developers in order to make sure that they do not sacrifice durability while making improvements in costs (e.g. lower platinum group metal [PGM] loading) and performance (e.g. thinner membrane or a GDL with better water management properties). To achieve a deeper understanding and improve PEM fuel cell durability LANL is conducting research to better define fuel cell component degradation mechanisms and correlate AST measurements to component in 'real-world' situations.

30 DIRECT ENERGY CONVERSION↗

DYNAMIC PRA WITH COMPONENT AGING AND DEGRADATION MODELED UTILIZING PLANT RISK MONITORING DATA

In the nuclear industry, risk monitors are intended to provide a point-in-time estimate of the system risk given the current plant configuration. Current risk monitors are limited in that they do not properly take into account the deteriorating states of plant systems, structures, and components (SSCs), which are unit-specific. Current approaches to computing risk monitors use probabilistic risk assessment (PRA) techniques, but the assessment is typically a snapshot in time. Living PRA models attempt to address limitations of traditional PRA models in a limited sense by including temporary changes in plant and system configurations. However, information on plant component health are not considered. This often leaves risk monitors using living PRA models incapable of conducting evaluations with dynamic degradation scenarios evolving over time. There is a need to develop enabling approaches to solidify risk monitors to provide time and condition-dependent risk by integrating traditional PRA models with condition monitoring and prognostic techniques [1]. This paper presents a novel hazard-rate based model of incorporating degradation of nuclear SSCs into an existing PRA model. Time-varying instantaneous hazard-rate of component is used to model degradation based on time-varying performance measure. The instantaneous hazard-rate is used to determine and update time-varying probability of failure of the components in their PRA models. The method is applied to estimate evolution of probability of failure of an in-service pump using vibration measurement taken while the pump undergoes degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of environmental variables on the degradation of photovoltaic components and perspectives for the reliability assessment methodology

Backsheet cracking has been a major issue observed in the field; however, standardized qualification tests, such as IEC61215, are inadequate to reliably identify such failures of PV modules due to the lack of the critical weathering factors applied sequentially or in combination, such as those found in the service environments. To address this problem, in this work we investigated the effects of various environmental variables on the degradation and failure behaviors of the polyamide-based backsheet in PV modules retrieved from five different locations, encompassing a variety of climates, including humid subtropical, hot-summer Mediterranean, tropical savanna climate and hot arid. The correlations between the degradation indicators and the weathering variables were further demonstrated by principle components analysis (PCA). We found strong relationships between: carbonyl formation and reflected solar radiation; hydroxyl formation and module temperature; yellowness and NO2 concentration, while no simple correlation could be found between a specific weathering factor and cracking. By introducing additional stress factors to the aged polyamide-based backsheet films with the novel 'fragmentation test', we successfully reproduced the field cracking behaviour. This study has demonstrated that different degradation modes of PV components respond differently to the environmental stresses encountered in service. Thereby, any accelerated laboratory test based on a single set condition or lacking key environmental variables would be inadequate to assess the long-term performance of PV modules and components. A new reliability-based methodology is proposed to quantitatively link laboratory testing with field results for the service life prediction of PV materials.

14 SOLAR ENERGY↗

Degradation of optical components in a space environment

Phillips Laboratory's Long Duration Exposure Facility (LDEF) optical experiment is designed to determine the adverse effects of the natural space environment on laser optical component and coating materials. The experiment consists of 10 sample sets, each containing six different material samples. The materials were chosen because of their common use in laser optical components. Sample characterization is divided into three phases. Phase 1 testing is limited to visual and optical performance evaluation. Phase 2 tests investigate the fundamental causes of the performance degradation quantified in Phase 1. During Phase 3, selected samples will be cleaned and some Phase 1 measurements repeated to determine if acceptable optical performance can be restored, and laser damage testing will be performed on a small number of samples. Performance deteriorations will be correlated to exposure duration, sample location on the LDEF, atomic oxygen levels, and other space environment conditions. Preliminary results obtained on the optical samples are discussed.

Dehainaut, Linda L.↗

Degradation of optical components in space

This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.

Blue, M. D.↗

Degradation of optical components in a space environment

The objective of the Phillips Laboratory (PL) Long Duration Exposure Facility (LDEF) experiment is to determine the adverse effects of the natural space environment on laser optical component and coating materials. The LDEF experiment provides a unique opportunity for the study of optical material response to an extended low earth orbit space exposure. The PL samples consist of 10 sets of the six materials each. The materials are uncoated fused silica, magnesium fluoride coated fused silica, uncoated molybdenum, molybdenum coated with chromium, silver and thorium fluoride, diamond turned copper, and diamond turned nickel plated copper. Performance degradation will be correlated to establish trends between sample location, duration of exposure, atomic oxygen exposure and other space environmental conditions. This paper discusses the results of the tests thus far performed on the LDEF samples and the plans for the future.

Dehainaut, Linda L.↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

SRG3/mBAF155 stabilizes the SWI/SNF-like BAF complex by blocking CHFR mediated ubiquitination and degradation of its major components

Highlights: Black-Right-Pointing-Pointer CHFR mediates the ubiquitination of the major components of the SWI/SNF complex. Black-Right-Pointing-Pointer CHFR mediated-ubiquitination induces the degradation of the major components. Black-Right-Pointing-Pointer SRG3 stabilizes the SWI/SNF-like BAF complex by blocking the CHFR activity. -- Abstract: The murine SWI/SNF-like BAF complex is an ATP-dependent chromatin remodeling complex that functions as a transcriptional regulator in cell proliferation, differentiation and development. The SWI/SNF-like BAF complex consists of several components including core subunits such as BRG1, BAF155/SRG3, BAF47/SNF5/INI1, and BAF170. We have previously shown that the interaction between SRG3/mBAF155 and other components of the complex stabilizes them by attenuating their proteasomal degradation. However, it has not been known how the major components of the SWI/SNF-like BAF complex such as BRG1, SNF5, and BAF60a are targeted for the ubiquitination and degradation, and how SRG3/mBAF155 protects them from the degradation process. Here we report that CHFR interacts with BRG1, SNF5, and BAF60a of the SWI/SNF-like BAF complex and ubiquitinates them to target for degradation through a proteasome-mediated pathway, and that SRG3/mBAF155 stabilizes these components by blocking their interaction with CHFR.

60 APPLIED LIFE SCIENCES↗

9975 Shipping package component long-term degradation rates

Special nuclear materials are being stored in the K-Area Complex using 3013 containers that are held within Model 9975 shipping packages. The service life for these packages in storage was recently increased from 15 to 20 years, since some of these packages have been stored for nearly 15 years. A strategy is also being developed whereby such storage might be extended beyond 20 years. This strategy is based on recent calculations that support acceptable 9975 package performance for 20 years with internal heat loads up to 19 watts, and identifies a lower heat load limit for which the package components should degrade at half the bounding rate or less, thus doubling the effective storage life for these lower wattage packages. The components of the 9975 package that are sensitive to aging under storage conditions are the fiberboard overpack and the O-ring seals, although some degradation of the lead shield and outer drum are also possible. This report summarizes degradation rates applicable to lower heat load storage conditions. In particular, the O-ring seals should provide leak-tight performance for more than 40 years in packages for which their maximum temperature is ≤135 °F. Similarly, the fiberboard should remain acceptable in performance of its required safety functions for up to 40 years in packages with a maximum fiberboard temperature ≤125 °F.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Machine Learning and Artificial Intelligence for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

97 - MATHEMATICS AND COMPUTING↗

Risk-informed Graded Approach for Reliability and Performance Assessment for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

99 - GENERAL AND MISCELLANEOUS↗

In orbit degradation of EUV optical components in the wavelength range 10-40 nm AO 138-3

A complement of EUV optical components, including mirrors and thin film filters, was flown as part of the Long Duration Exposure Facility (LDEF) AO 138-3. The most original amongst these components were multilayered interference reflectors for the 10-40 nm wavelength range. Very moderate degradation was observed for those components which were exposed to the sun. The degradation is compatible with the deposition of a few nanometers of absorbing material on the surface of the samples.

Delaboudiniere, J. P.↗

RELIABILITY MODELS OF AGING PASSIVE COMPONENTS INFORMED BY MATERIALS DEGRADATION METRICS TO SUPPORT LONG-TERM REACTOR OPERATIONS

Paper describes a methodology for the synthesis of nuclear power plant service data with expert-elicited materials degradation information to estimate the future failure rates of passive components. This method should be an important resource to long-term plant operations and reactor life extension. Conventional probabilistic risk assessments (PRAs) are not well suited to addressing long-term reactor operations. Since passive structures and components are among those for which replacement can be least practical, they might be expected to contribute increasingly to risk in an aging plant; yet, passives receive limited treatment in PRAs. Furthermore, PRAs produce only snapshots of risk based on the assumption of time-independent component failure rates. This assumption is unlikely to be valid in aging systems. The treatment of aging passive components in PRA presents challenges. Service data to quantify component reliability models are sparse, and this is exacerbated by the greater data demands of age-dependent reliability models. Another factor is that there can be numerous potential degradation mechanisms associated with the materials and operating environment of a given component. This deepens the data problem since risk-informed management of component aging will demand an understanding of the long-term risk significance of individual degradation mechanisms. In this paper we describe a Bayesian methodology that integrates metrics of materials degradation susceptibility with available plant service data to estimate age-dependent passive component reliabilities. Integration of these models into conventional PRA will provide a basis for materials degradation management informed by predicted long-term operational risk.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗