Personal Experience with the PVHD and Opinion of Situations in Which a Wide Field of View (FOV) PVHD Might Be Helpful

Personal experience with the PVHD indicates that it should have great promise in easing cockpit workload, improving situational awareness, and reducing spatial disorientation. It should not be assumed that the PVHD will automatically cue the pilot to his attitude without some training or exposure. Some measure of attention needs to be devoted to attitude although this can easily be accomplished by the peripheral visual fields without tying up central vision. The PVHD would appear useful in any aircraft that flies in spatially disorienting/misorienting conditions, such as night, weather, or formation. It would appear to be particularly useful in aircraft, that by their design, are especially disorienting in such circumstances.

Mcnaughton, G. B.

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements

Visual motion integration for perception and pursuit

To examine the relationship between visual motion processing for perception and pursuit, we measured the pursuit eye-movement and perceptual responses to the same complex-motion stimuli. We show that humans can both perceive and pursue the motion of line-figure objects, even when partial occlusion makes the resulting image motion vastly different from the underlying object motion. Our results show that both perception and pursuit can perform largely accurate motion integration, i.e. the selective combination of local motion signals across the visual field to derive global object motion. Furthermore, because we manipulated perceived motion while keeping image motion identical, the observed parallel changes in perception and pursuit show that the motion signals driving steady-state pursuit and perception are linked. These findings disprove current pursuit models whose control strategy is to minimize retinal image motion, and suggest a new framework for the interplay between visual cortex and cerebellum in visuomotor control.

NASA Center ARC

Image Processor

Texas Instruments Programmable Remapper is a research tool used to determine how to best utilize the part of a patient's visual field still usable by mapping onto his field of vision with manipulated imagery. It is an offshoot of a NASA program for speeding up, improving the accuracy of pattern recognition in video imagery. The Remapper enables an image to be "pushed around" so more of it falls into the functional portions in the retina of a low vision person. It works at video rates, and researchers hope to significantly reduce its size and cost, creating a wearable prosthesis for visually impaired people.

Source record

Increased Intracranial Pressure and Visual Impairment Associated with Long-Duration Spaceflight

Although humans have been flying in space since the 1960s, more recent missions have revealed a new suite of physiological adaptations and consequences of space flight. Notably, 60% of long-duration crewmembers (ISS/MIR) and >25% of short-duration (Shuttle) crewmembers have reported subjective degradation in vision (based on debrief comments) (Gibson 2011). Decreased near-visual acuity was demonstrated in 46% of ISS/Mir and 21% of Shuttle crewmembers, resulting in a shift of up to 1-2 diopters in their refractive correction. It is likely that the recently revealed ophthalmic changes have been present since the first days of human space flight, but have been overlooked or attributed to other causations. The reported changes in vision have occurred at various time points throughout missions, with ranging degrees of visual degradation. Although some cases resolved upon return to Earth, several astronauts have not regained preflight visual acuity, indicating that the damage may be permanent. While observing these changes over the years, without other overt symptomology and with the given age range of the flying population, this has largely been attributed to an expected hyperopic shift due to aging. However, the availability of onboard analysis techniques, including visual acuity assessments, retinal imagery, and ultrasounds of the eye and optic nerve tracts, along with more detailed post-flight techniques, has led to the recent recognition of a wider syndrome. Along with vision changes, findings include flattening of the globe, swelling of the optic disc (papilledema), choroidal folds in the retina, swelling of the optic nerve sheath, and visual field defects. It is widely hypothesized that this constellation of findings may be explained by an elevation of intracranial pressure (ICP). Out of the 60% of long-duration astronauts that have reported a subjective degradation in vision, a subset (currently 10 astronauts) have developed this syndrome. The National Aeronautics and Space Administration (NASA) has made it a high priority to understand this syndrome and provide mitigation techniques to protect crewmembers from visual impairment. While there are many possible factors that could contribute to intracranial hypertension associated with spaceflight, the relative contribution of these, as well as the processes by which eye damage occurs as a result of intracranial hypertension, are not fully understood. The observed pathophysiological phenomena are extremely complex and it is likely that multiple factors contribute to their incidence, rather than one simple mechanism. This paper will define and examine the findings in detail, and expound upon the potential contributing factors and their relative contribution to this syndrome.

Marshall-Bowman, Karina

Conspicuity of target lights: The influence of flash rate and brightness

The stimulus characteristics of lights that might aid a pilot to see and avoid, by alerting him to a potential threat were studied. The relative conspicuity of foveally equated, point-source, steady and flashing lights of several brightnesses, seen against a star background was examined. From the subject's viewpoint, these target lights could appear anywhere within a large (40 deg horizontal by 35 deg vertical) field of view. The lights appeared at random time intervals while the subject was periodically distracted by a simulated cockpit task. The results indicate that correct target detection increases and reaction time decreases with increased target intensity. Steady lights are missed more frequently and acquired more slowly than flashing lights, but no significant differences are found among the wide range of flash rates employed. The intensity of the light has a greater effect on both detection and reaction time to steady lights than to flashing lights. These results are compared with results of other researchers who used targets which appeared at fixed locations. The longest reaction times were recorded to lights which appeared either at the extremes or at the very center of the visual field.

Connors, M. M.

Retinal, attentional, and causal aspects of illusory-motion directionality

Extended objects presented instantaneously appeared to propagate or grow into their final shape. A strong bias was found toward perceiving straight lines to grow away from the observer's point of fixation. If attention and fixation were not directed to the same point of the visual field, both influenced illusory motion directionality, and if another small object was present on the screen at a location that was neither fixated nor attended to, the object that was instantaneously presented seemed to grow away from this point. Thus, three factors are involved in illusory-motion directionality: biases toward perceiving objects spreading away from the fixation point, away from an attended area, and away from preexisting objects. The experiments indicate that a satisfactory explanation of the illusion has to include bottom-up and top-down processes. They also challenge existing theories of motion detection.

Pattern Recognition, Visual/physiology

Orientation of human optokinetic nystagmus to gravity: a model-based approach

Optokinetic nystagmus (OKN) was induced by having subjects watch a moving display in a binocular, head-fixed apparatus. The display was composed of 3.3 degrees stripes moving at 35 degrees/s for 45 s. It subtended 88 degrees horizontally by 72 degrees vertically of the central visual field and could be oriented to rotate about axes that were upright or tilted 45 degrees or 90 degrees. The head was held upright or was tilted 45 degrees left or right on the body during stimulation. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined and compared with the axis of stimulation and the spatial vertical (gravity axis). With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted, a significant vertical component of eye velocity appeared during yaw axis stimulation. As a result the axis of eye rotation shifted from the stimulus axis toward the spatial vertical. Vertical components developed within 1-2 s of stimulus onset and persisted until the end of stimulation. In the six subjects there was a mean shift of the axis of eye rotation during yaw axis stimulation of approximately 18 degrees with the head tilted 45 degrees on the body. Oblique optokinetic stimulation with the head upright was associated with a mean shift of the axis of eye rotation toward the spatial vertical of 9.2 degrees. When the head was tilted and the same oblique stimulation was given, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 degrees. This counterrotation of the axis of eye rotation is similar to the "Muller (E) effect," in which the perception of the upright is counterrotated to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN with a "direct" and "indirect" pathway. It was assumed that the direct visual pathway is oriented in a body, not a spatial frame of reference. Despite the short optokinetic after-nystagmus time constants, strong horizontal to vertical cross-coupling could be produced if the horizontal and vertical time constants were in proper ratio and there were no suppression of nystagmus in directions orthogonal to the stimulus direction. The model demonstrates that the spatial orientation of OKN can be achieved by restructuring the system matrix of velocity storage. We conclude that an important function of velocity storage is to orient slow-phase velocity toward the spatial vertical during movement in a terrestrial environment.

Non-NASA Center

One-piece transparent shell improves design of helmet assembly

One-piece transparent helmet shell made of polycarbonate is equipped with a helmet protection pad, a visor assembly, a communications skull cap, and an emergency oxygen supply. This design offers improvements over previous designs in weight, visual field, comfort and protection.

Jones, R. L.

Visual sensitivity tester

Testing device uses closed loop film cassettes to project programmed visual stimuli on screen which the observer views through a lens making the stimuli appear to be at optical infinity. Tester is useful for determining changes in glautomatous visual field sensitivity.

Haines, R. F.

Medical technology advances from space research.

NASA-sponsored medical R & D programs for space applications are reviewed with particular attention to the benefits of these programs to earthbound medical services and to the general public. Notable among the results of these NASA programs is an integrated medical laboratory equipped with numerous advanced systems such as digital biotelemetry and automatic visual field mapping systems, sponge electrode caps for electroencephalograms, and sophisticated respiratory analysis equipment.

Pool, S. L.

Differences in apparent straightness of dot and line stimuli.

An investigation has been made of anisotropic responses to contoured and noncontoured stimuli to obtain an insight into the way these stimuli are processed. For this purpose, eight subjects judged the alignment of minimally contoured (3 dot) and contoured (line) stimuli. Stimuli, presented to each eye separately, vertically subtended either 8 or 32 deg visual angle and were located 10 deg left, center, or 10 deg right in the visual field. Location-dependent deviations from physical straightness were larger for dot stimuli than for lines. The results were the same for the two eyes. In a second experiment, subjects judged the alignment of stimuli composed of different densities of dots. Apparent straightness for these stimuli was the same as for lines. The results are discussed in terms of alternative mechanisms for analysis of contoured and minimally contoured stimuli.

Parlee, M. B.

The measurement of driver describing functions in simulated steering control tasks

Measurements of driver describing functions in steering control tasks have been made using a driving simulator. The task was to regulate against a random crosswind gust input on a straight roadway, in order to stay in the center of the lane. Although driving is a multiloop task in general, the forcing function and situation were configured so that an inner-loop visual cue feedback of heading angle of heading rate would dominate, and the driver's response was interpreted to be primarily single-loop. The driver describing functions were measured using an STI describing function analyzer. Three replications for each subject showed good repeatability within a subject. There were some intersubject differences as expected, but the crossover frequencies, effective time delays, and stability margins were generally consistent with the prior data and models for similar manual control tasks. The results further confirm the feasibility of measuring human operator response properties in nominal control tasks with full (real-world) visual field displays.

Weir, D. H.

Medical technology advances from space research

Details of medical research and development programs, particularly an integrated medical laboratory, as derived from space technology are given. The program covers digital biotelemetry systems, automatic visual field mapping equipment, sponge electrode caps for clinical electroencephalograms, and advanced respiratory analysis equipment. The possibility of using the medical laboratory in ground based remote areas and regional health care facilities, as well as long duration space missions is discussed.

Pool, S. L.

Heat transfer and pressure distributions at M equals 8 on 0.029 scale models of the Viking entry vehicle

An investigation in the Langley Research Center Mach-8 Variable Density Hypersonic Tunnel was made of the pressure distributions and heat transfer rate distributions on two 0.029 scale Viking Entry Vehicle models. Comparable ranges of test Reynolds number were exercised for the two tests between run conditions around 4 million and conditions of about 1.6 million. At angles of attack less than 20 degrees the pressure ratio distribution referenced to stagnation pressure appeared invariant with Reynolds number. Increasing angle of attack results in a flatter distribution of both the windward and leeward pressure distributions; in addition, the stagnation point shifted into the windward plane. A subsequent rise in the heating rate profile on the leeward side with further increase in angle of attack is attributed to boundary layer natural transition to turbulent flow. Schlieren photographs were taken for flow field visualization and to correct model angle of attack.

Faye-Petersen, R.

Effects of viscoelasticity on cavitation in drag reducing fluids

To study cavitation inception in polymer solutions, a blow-down water tunnel with short running times was used. Tests were made using 1/4 and 1/2 inch diameter models of hemispherical-nose cylinders. To accurately detect the inception of cavitation, a reliable technique was developed using a continuously operating He-Ne gas laser. The laser beam was adjusted to grazing incidence with the model at the minimum pressure point where cavitation inception was to be expected. A sensitive photocell was placed at ninety degrees to detect the beam. As incipient cavitation occurred, the bubbles caused scattering of the laser beam which was picked up by the photocell. Static pressure near the model in the working section of the tunnel was measured using a solid-state pressure pick-up. The signals from the photocell and the pressure pick-up were recorded on an oscillograph. Velocity field visualization was achieved using one microsecond duration light pulses scattered by small polystryrene latex spheres in the flow.

Ting, R. Y.

Manual and automatic control of surface effect ships

A recent investigation of crew performance in the motion environment of a large generic high speed surface effect ship by means of a motion base simulation addressed some of the helmsman's control task with an external forward visual field of the seascape and navigation and steering displays in the pilot house. In addition to the primary steering control task, a subcritical speed tracking task provided a secondary surrogate for trimming the water speed of the craft. The results of helsmen's steering describing function measurements are presented, and some suggestions for their interpretation are offered. The likely steering loop closures comprise heading and lateral displacement for the course keeping task investigated. Also discussed is the manner in which these loop closures were implemented for automatic steering of the surface effect ship. Regardless of the influence of workload, steering technique, water speed and sea state, the helmsmen apparently adopted a disturbance regulation bandwidth of about 0.2 rad/sec for lateral displacement.

Clement, W. F.

Variable radio source structure on a scale of several minutes of arc

Results are reported for high-frequency (0.75, 1.40, 3.24, 6.63, and 10.63 GHz) flux-density measurements of about 100 radio sources exhibiting low-frequency cutoffs. At least three sources (4C 79.4, 4C 79.15, and PKS 2344+09) showed variable structure on a scale ranging from a fraction of an arcmin to as much as 15 arcmin which appears to change significantly on a time scale of several months. The visual fields of these sources and their companion components are searched for identifiable objects, and complete radio spectra as well as contour maps are presented for some of the sources. It is suggested that the variable structure may result from the existence of several emission centers that are highly variable in flux density but fixed in position.