Engineering PapersSearch

NASA NTRS · 20040112689

Visual motion integration for perception and pursuit

Abstract

To examine the relationship between visual motion processing for perception and pursuit, we measured the pursuit eye-movement and perceptual responses to the same complex-motion stimuli. We show that humans can both perceive and pursue the motion of line-figure objects, even when partial occlusion makes the resulting image motion vastly different from the underlying object motion. Our results show that both perception and pursuit can perform largely accurate motion integration, i.e. the selective combination of local motion signals across the visual field to derive global object motion. Furthermore, because we manipulated perceived motion while keeping image motion identical, the observed parallel changes in perception and pursuit show that the motion signals driving steady-state pursuit and perception are linked. These findings disprove current pursuit models whose control strategy is to minimize retinal image motion, and suggest a new framework for the interplay between visual cortex and cerebellum in visuomotor control.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stone, L. S., Beutter, B. R., Lorenceau, J.. 2000-01-01. Visual motion integration for perception and pursuit. https://ntrs.nasa.gov/citations/20040112689

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

A multiparameter wearable physiologic monitoring system for space and terrestrial applications

A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

NASA Center ARC

Methods for the culture of C. elegans and S. cerevisiae in microgravity

To support the study of the effects of microgravity on biological systems, our group is developing and testing methods that allow the cultivation of C. elegans and S. cerevisiae in microgravity. Our aim is to develop the experimental means by which investigators may conduct peer reviewed biological experiments with C. elegans or S. cerevisiae in microgravity. Our protocols are aimed at enabling investigators to grow these organisms for extended periods during which samples may be sub-cultured, collected, preserved, frozen, and/or returned to earth for analysis. Data presented include characterization of the growth phenotype of these organisms in liquid medium in OptiCells(TM) (Biocrystal, LTD).

NASA Center ARC

The relationship between perceived length and egocentric location in Muller-Lyer figures with one versus two chevrons

We examined the apparent dissociation of perceived length and perceived position with respect to the Muller-Lyer (M-L) illusion. With the traditional (two-chevron) figure, participants made accurate open-loop pointing responses at the endpoints of the shaft, despite the presence of a strong length illusion. This apparently non-Euclidean outcome replicated that of Mack, Heuer, Villardi, and Chambers (1985) and Gillam and Chambers (1985) and contradicts any theory of the M-L illusion in which mislocalization of shaft endpoints plays a role. However, when one of the chevrons was removed, a constant pointing error occurred in the predicted direction, as well as a strong length illusion. Thus, with one-chevron stimuli, perceived length and location were no longer completely dissociated. We speculated that the presence of two opposing chevrons suppresses the mislocalizing effects of a single chevron, especially for figures with relatively short shafts.

NASA Center ARC