Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Visual Fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Long Duration Head-Down Tilt Bed Rest Studies: Safety Considerations Regarding Vision Health

Visual symptoms reported in astronauts returning from long duration missions in low Earth orbit, including hyperopic shift, choroidal folds, globe flattening and papilledema, are thought to be related to fluid shifts within the body due to microgravity exposure. Because of this possible relation to fluid shifts, safety considerations have been raised regarding the ocular health of head-down tilt (HDT) bed rest subjects. HDT is a widely used ground ]based analog that simulates physiological changes of spaceflight, including fluid shifts. Thus, vision monitoring has been performed in bed rest subjects in order to evaluate the safety of HDT with respect to vision health. Here we report ocular outcomes in 9 healthy subjects (age range: 27-48 years; Male/Female ratio: 8/1) completing bed rest Campaign 11, an integrated, multidisciplinary 70-day 6 degrees HDT bed rest study. Vision examinations were performed on a weekly basis, and consisted of office-based (2 pre- and 2 post-bed rest) and in-bed testing. The experimental design was a repeated measures design, with measurements for both eyes taken for each subject at each planned time point. Findings for the following tests were all reported as normal in each testing session for every subject: modified Amsler grid, red dot test, confrontational visual fields, color vision and fundus photography. Overall, no statistically significant differences were observed for any of the measures, except for both near and far visual acuity, which increased during the course of the study. This difference is not considered clinically relevant as may result from the effect of learning. Intraocular pressure results suggest a small increase at the beginning of the bed rest phase (p=0.059) and lesser increase at post-bed rest with respect to baseline (p=0.046). These preliminary results provide the basis for further analyses that will include correlations between intraocular pressure change pre- and post-bed rest, and optical coherence tomography measurements of the retina.

Cromwell, Ronita L.↗

Augmented Reality in a Simulated Tower Environment: Effect of Field of View on Aircraft Detection

An optical see-through, augmented reality display was used to study subjects' ability to detect aircraft maneuvering and landing at the Dallas Ft. Worth International airport in an ATC Tower simulation. Subjects monitored the traffic patterns as if from the airport's western control tower. Three binocular fields of view (14 deg, 28 deg and 47 deg) were studied in an independent groups' design to measure the degradation in detection performance associated with the visual field restrictions. In a second experiment the 14 deg and 28 deg fields were presented either with 46% binocular overlap or 100% overlap for separate groups. The near asymptotic results of the first experiment suggest that binocular fields of view much greater than 47% are unlikely to dramatically improve performance; and those of the second experiment suggest that partial binocular overlap is feasible for augmented reality displays such as may be used for ATC tower applications.

Ellis, Stephen R.↗

A Workflow to Rapidly Interrogate Multiscale Model Simulation Results Across Multiple Length Scales

Many tools can be used to visualize field and state variables for a single scale analysis so that the influence of relevant mechanisms can be evaluated. Finite element software is often utilized to simulate a unit cell of a material and visualize results at that scale. Material properties can be homogenized from individual constituents and local deformation, damage, and failure mechanisms can be evaluated within the unit cell due to globally applied boundary conditions. Such solutions can produce satisfactory results if a user is only interested in analyzing a single scale. But materials in general contain features across multiple length scales, and assumptions must be made when attempting to account for lower length scale phenomena within a higher length scale model. Multiscale modeling is an attractive means to model materials because detailed material responses can be tracked across multiple disparate length scales while reducing the amount of required assumptions. However, as the complexity of these models increases, a large amount of data can be produced, and data traceability can become increasingly more difficult. Field and state variables, which are naturally dependent on spatial position, may themselves be calculated from one or more lower length scale unit cell models each with their own appropriate field and state variables. The NASA Multiscale Analysis Tool (NASMAT) is one software that can be used to perform a multiscale analysis efficiently and output requested data at all length scales in the analysis. A companion open-source Python software, NASMAT PrePost, can be used to visualize NASMAT model results and rapidly interrogate multiscale data across multiple length scales. This presentation will demonstrate some of the key features of NASMAT PrePost on two multiscale problems by quickly displaying and demonstrating connectivity among multiscale results from large datasets.

Python↗

Local bilinear computation of Jacobi sets

Abstract We propose a novel method for the computation of Jacobi sets in 2D domains. The Jacobi set is a topological descriptor based on Morse theory that captures gradient alignments among multiple scalar fields, which is useful for multi-field visualization. Previous Jacobi set computations use piecewise linear approximations on triangulations that result in discretization artifacts like zig-zag patterns. In this paper, we utilize a local bilinear method to obtain a more precise approximation of Jacobi sets by preserving the topology and improving the geometry. Consequently, zig-zag patterns on edges are avoided, resulting in a smoother Jacobi set representation. Our experiments show a better convergence with increasing resolution compared to the piecewise linear method. We utilize this advantage with an efficient local subdivision scheme. Finally, our approach is evaluated qualitatively and quantitatively in comparison with previous methods for different mesh resolutions and across a number of synthetic and real-world examples.

97 MATHEMATICS AND COMPUTING↗

Perception of linear horizontal self-motion induced by peripheral vision /linearvection/ - Basic characteristics and visual-vestibular interactions

The basic characteristics of the sensation of linear horizontal motion have been studied. Objective linear motion was induced by means of a moving cart. Visually induced linear motion perception (linearvection) was obtained by projection of moving images at the periphery of the visual field. Image velocity and luminance thresholds for the appearance of linearvection have been measured and are in the range of those for image motion detection (without sensation of self motion) by the visual system. Latencies of onset are around 1 sec and short term adaptation has been shown. The dynamic range of the visual analyzer as judged by frequency analysis is lower than the vestibular analyzer. Conflicting situations in which visual cues contradict vestibular and other proprioceptive cues show, in the case of linearvection a dominance of vision which supports the idea of an essential although not independent role of vision in self motion perception.

Berthoz, A.↗

An Introduction to Data Visualization

Data visualization can be used to present findings, explore data, and use the human eye to find patterns that a computer would struggle to locate. Borrowing tools from art, storytelling, data analytics and software development, data visualization is an indispensable part of the analysis process. While data visualization usage spans across multiple disciplines and sectors, most never receive formal training in the subject. As such, this tutorial will introduce key data visualization building blocks and how to best use those building blocks for different scenarios and audiences. We will also go over tips on accessibility, design and interactive elements. While this will by no means be a complete overview of the data visualization field, by building a foundation and introducing some rules of thumb, attendees will be better equipped for communicating their findings to their audience.

data visualization↗

Experimental testing of flight control head up displays

Experiments and tests with 4 generations of head up displays was reported. The CV 191, based on fighter aircraft gunsights was replaced by the CV 193, with several improvements. The CV 193 V incorporates the velocity vector reference mark, eliminates much other data, clusters the rest in a small area of the visual field and is seen together with the outside landscape. The CV 91 presents only velocity vector and total angle of descent data, used when runway and horizon are visible; TC 121 displays an outline of the runway and can be used in visual and instrument approaches.

Berjal, M.↗

Personal Experience with the PVHD and Opinion of Situations in Which a Wide Field of View (FOV) PVHD Might Be Helpful

Personal experience with the PVHD indicates that it should have great promise in easing cockpit workload, improving situational awareness, and reducing spatial disorientation. It should not be assumed that the PVHD will automatically cue the pilot to his attitude without some training or exposure. Some measure of attention needs to be devoted to attitude although this can easily be accomplished by the peripheral visual fields without tying up central vision. The PVHD would appear useful in any aircraft that flies in spatially disorienting/misorienting conditions, such as night, weather, or formation. It would appear to be particularly useful in aircraft, that by their design, are especially disorienting in such circumstances.

Mcnaughton, G. B.↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Visual motion integration for perception and pursuit

To examine the relationship between visual motion processing for perception and pursuit, we measured the pursuit eye-movement and perceptual responses to the same complex-motion stimuli. We show that humans can both perceive and pursue the motion of line-figure objects, even when partial occlusion makes the resulting image motion vastly different from the underlying object motion. Our results show that both perception and pursuit can perform largely accurate motion integration, i.e. the selective combination of local motion signals across the visual field to derive global object motion. Furthermore, because we manipulated perceived motion while keeping image motion identical, the observed parallel changes in perception and pursuit show that the motion signals driving steady-state pursuit and perception are linked. These findings disprove current pursuit models whose control strategy is to minimize retinal image motion, and suggest a new framework for the interplay between visual cortex and cerebellum in visuomotor control.

NASA Center ARC↗

Image Processor

Texas Instruments Programmable Remapper is a research tool used to determine how to best utilize the part of a patient's visual field still usable by mapping onto his field of vision with manipulated imagery. It is an offshoot of a NASA program for speeding up, improving the accuracy of pattern recognition in video imagery. The Remapper enables an image to be "pushed around" so more of it falls into the functional portions in the retina of a low vision person. It works at video rates, and researchers hope to significantly reduce its size and cost, creating a wearable prosthesis for visually impaired people.

Source record↗

Increased Intracranial Pressure and Visual Impairment Associated with Long-Duration Spaceflight

Although humans have been flying in space since the 1960s, more recent missions have revealed a new suite of physiological adaptations and consequences of space flight. Notably, 60% of long-duration crewmembers (ISS/MIR) and >25% of short-duration (Shuttle) crewmembers have reported subjective degradation in vision (based on debrief comments) (Gibson 2011). Decreased near-visual acuity was demonstrated in 46% of ISS/Mir and 21% of Shuttle crewmembers, resulting in a shift of up to 1-2 diopters in their refractive correction. It is likely that the recently revealed ophthalmic changes have been present since the first days of human space flight, but have been overlooked or attributed to other causations. The reported changes in vision have occurred at various time points throughout missions, with ranging degrees of visual degradation. Although some cases resolved upon return to Earth, several astronauts have not regained preflight visual acuity, indicating that the damage may be permanent. While observing these changes over the years, without other overt symptomology and with the given age range of the flying population, this has largely been attributed to an expected hyperopic shift due to aging. However, the availability of onboard analysis techniques, including visual acuity assessments, retinal imagery, and ultrasounds of the eye and optic nerve tracts, along with more detailed post-flight techniques, has led to the recent recognition of a wider syndrome. Along with vision changes, findings include flattening of the globe, swelling of the optic disc (papilledema), choroidal folds in the retina, swelling of the optic nerve sheath, and visual field defects. It is widely hypothesized that this constellation of findings may be explained by an elevation of intracranial pressure (ICP). Out of the 60% of long-duration astronauts that have reported a subjective degradation in vision, a subset (currently 10 astronauts) have developed this syndrome. The National Aeronautics and Space Administration (NASA) has made it a high priority to understand this syndrome and provide mitigation techniques to protect crewmembers from visual impairment. While there are many possible factors that could contribute to intracranial hypertension associated with spaceflight, the relative contribution of these, as well as the processes by which eye damage occurs as a result of intracranial hypertension, are not fully understood. The observed pathophysiological phenomena are extremely complex and it is likely that multiple factors contribute to their incidence, rather than one simple mechanism. This paper will define and examine the findings in detail, and expound upon the potential contributing factors and their relative contribution to this syndrome.

Marshall-Bowman, Karina↗

Conspicuity of target lights: The influence of flash rate and brightness

The stimulus characteristics of lights that might aid a pilot to see and avoid, by alerting him to a potential threat were studied. The relative conspicuity of foveally equated, point-source, steady and flashing lights of several brightnesses, seen against a star background was examined. From the subject's viewpoint, these target lights could appear anywhere within a large (40 deg horizontal by 35 deg vertical) field of view. The lights appeared at random time intervals while the subject was periodically distracted by a simulated cockpit task. The results indicate that correct target detection increases and reaction time decreases with increased target intensity. Steady lights are missed more frequently and acquired more slowly than flashing lights, but no significant differences are found among the wide range of flash rates employed. The intensity of the light has a greater effect on both detection and reaction time to steady lights than to flashing lights. These results are compared with results of other researchers who used targets which appeared at fixed locations. The longest reaction times were recorded to lights which appeared either at the extremes or at the very center of the visual field.

Connors, M. M.↗

Retinal, attentional, and causal aspects of illusory-motion directionality

Extended objects presented instantaneously appeared to propagate or grow into their final shape. A strong bias was found toward perceiving straight lines to grow away from the observer's point of fixation. If attention and fixation were not directed to the same point of the visual field, both influenced illusory motion directionality, and if another small object was present on the screen at a location that was neither fixated nor attended to, the object that was instantaneously presented seemed to grow away from this point. Thus, three factors are involved in illusory-motion directionality: biases toward perceiving objects spreading away from the fixation point, away from an attended area, and away from preexisting objects. The experiments indicate that a satisfactory explanation of the illusion has to include bottom-up and top-down processes. They also challenge existing theories of motion detection.

Pattern Recognition, Visual/physiology↗

Orientation of human optokinetic nystagmus to gravity: a model-based approach

Optokinetic nystagmus (OKN) was induced by having subjects watch a moving display in a binocular, head-fixed apparatus. The display was composed of 3.3 degrees stripes moving at 35 degrees/s for 45 s. It subtended 88 degrees horizontally by 72 degrees vertically of the central visual field and could be oriented to rotate about axes that were upright or tilted 45 degrees or 90 degrees. The head was held upright or was tilted 45 degrees left or right on the body during stimulation. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined and compared with the axis of stimulation and the spatial vertical (gravity axis). With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted, a significant vertical component of eye velocity appeared during yaw axis stimulation. As a result the axis of eye rotation shifted from the stimulus axis toward the spatial vertical. Vertical components developed within 1-2 s of stimulus onset and persisted until the end of stimulation. In the six subjects there was a mean shift of the axis of eye rotation during yaw axis stimulation of approximately 18 degrees with the head tilted 45 degrees on the body. Oblique optokinetic stimulation with the head upright was associated with a mean shift of the axis of eye rotation toward the spatial vertical of 9.2 degrees. When the head was tilted and the same oblique stimulation was given, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 degrees. This counterrotation of the axis of eye rotation is similar to the "Muller (E) effect," in which the perception of the upright is counterrotated to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN with a "direct" and "indirect" pathway. It was assumed that the direct visual pathway is oriented in a body, not a spatial frame of reference. Despite the short optokinetic after-nystagmus time constants, strong horizontal to vertical cross-coupling could be produced if the horizontal and vertical time constants were in proper ratio and there were no suppression of nystagmus in directions orthogonal to the stimulus direction. The model demonstrates that the spatial orientation of OKN can be achieved by restructuring the system matrix of velocity storage. We conclude that an important function of velocity storage is to orient slow-phase velocity toward the spatial vertical during movement in a terrestrial environment.

Non-NASA Center↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Breaking the barrier of human-annotated training data for machine learning-aided plant research using aerial imagery

Machine learning (ML) can accelerate biological research. However, the adoption of such tools to facilitate phenotyping based on sensor data has been limited by (i) the need for a large amount of human-annotated training data for each context in which the tool is used and (ii) phenotypes varying across contexts defined in terms of genetics and environment. This is a major bottleneck because acquiring training data is generally costly and time-consuming. This study demonstrates how a ML approach can address these challenges by minimizing the amount of human supervision needed for tool building. A case study was performed to compare ML approaches that examine images collected by an uncrewed aerial vehicle to determine the presence/absence of panicles (i.e. “heading”) across thousands of field plots containing genetically diverse breeding populations of 2 Miscanthus species. Automated analysis of aerial imagery enabled the identification of heading approximately 9 times faster than in-field visual inspection by humans. Leveraging an Efficiently Supervised Generative Adversarial Network (ESGAN) learning strategy reduced the requirement for human-annotated data by 1 to 2 orders of magnitude compared to traditional, fully supervised learning approaches. The ESGAN model learned the salient features of the data set by using thousands of unlabeled images to inform the discriminative ability of a classifier so that it required minimal human-labeled training data. This method can accelerate the phenotyping of heading date as a measure of flowering time in Miscanthus across diverse contexts (e.g. in multistate trials) and opens avenues to promote the broad adoption of ML tools.

59 BASIC BIOLOGICAL SCIENCES↗

Event-related brain potentials reveal how multiple aspects of semantic processing unfold across parafoveal and foveal vision during sentence reading

Recent event–related brain potential (ERP) experiments have demonstrated parafoveal N400 expectancy and congruity effects, showing that semantic information can be accessed from words in parafoveal vision (a conclusion also supported by some eye–tracking work). At the same time, it is unclear how higher–order integrative aspects of language comprehension unfold across the visual field during reading. In the current study, we recorded ERPs in a parafoveal flanker paradigm, while readers were instructed to read passively for comprehension or to judge the plausibility of sentences in which target words varied in their semantic expectancy and congruity. We directly replicated prior work showing graded N400 effects for parafoveal viewing, which are then not duplicated when the target words are processed foveally. Critically, although N400 effects were not modulated by task goals, a posteriorly distributed late positive component thought to reflect semantic integration processes was observed to semantic incongruities only in the plausibility judgment task. Furthermore, this effect was observed at a considerable delay, appearing only after words had moved into foveal vision. Our findings thus suggest that semantic access can be initiated in parafoveal vision, whereas central foveal vision may be necessary to enact higher–order (and task–dependent) integrative processing.

60 APPLIED LIFE SCIENCES↗