Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THOMSON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigation of first mirror heating for the collective Thomson scattering diagnostic in ITER

Collective Thomson scattering (CTS) has the capabilities to measure phase space densities of fast ion populations in ITER resolved in configuration space, in velocity space, and in time. In the CTS system proposed for ITER, probing radiation at 60 GHz generated by two 1 MW gyrotrons is scattered in the plasma and collected by arrays of receivers. The transmission lines from the gyrotrons to the plasma and from the plasma to the receivers contain several quasioptical mirrors among other components. These are designed to produce astigmatic beam patterns in the plasma where the beam shapes will have a direct impact on the signal strength of the diagnostic, the spatial resolution, and the robustness of probe and receiver beam overlap against density excursions. The first mirror has a line of sight to the plasma and is thus exposed to severe neutron streaming. The present neutronics and thermomechanical modeling of a first mirror on the high field side indicates that the mirror curvature may warp due to heating. This may alter the beam quality, and therefore, thermal effects have to be accounted for during the design of the mirror. The modeling further demonstrates that thin mirrors are superior to thick mirrors from a thermomechanical point of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-free Rayleigh weight from x-ray Thomson scattering measurements

X-ray Thomson scattering (XRTS) has emerged as a powerful tool for the diagnostics of matter under extreme conditions. In principle, it gives one access to important system parameters such as the temperature, density, and ionization state, but the interpretation of the measured XRTS intensity usually relies on theoretical models and approximations. In this context, a key property is given by the Rayleigh weight that describes the electronic localization around the ions. Here, we show that it is possible to extract the Rayleigh weight directly from the experimental data without the need for any model calculations or simulations. As a practical application, we consider an experimental measurement of strongly compressed Be at the National Ignition Facility [Döppner et al., Nature 618, 270–275 (2023)]. We demonstrate that experimental results for the Rayleigh weight open up new avenues for the interpretation of XRTS experiments by matching the measurement with ab initio simulations such as density functional theory or path integral Monte Carlo. Interestingly, this new procedure leads to significantly lower density compared to previously used chemical models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Signal evaluations using singular value decomposition for Thomson scattering diagnostics

This paper provides a novel method for evaluating signal intensities in incoherent Thomson scattering diagnostics. A double-pass Thomson scattering system, where a laser passes through the plasma twice, generates two scattering pulses from the plasma. Evaluations of the signal intensities in the spectrometer are sometimes difficult due to noise and stray light. We apply the singular value decomposition method to Thomson scattering data with strong noise components. Results show that the average accuracy of the measured electron temperature (T{sub e}) is superior to that of temperature obtained using a low-pass filter (<20 MHz) or without any filters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short-interval multi-laser Thomson scattering measurements of hydrogen pellet ablation in LHD

Thomson scattering forms an important aspect of measuring the electron density and temperature profiles of plasmas. In this study, we demonstrate Thomson scattering measurements obtained over a short interval (<1 ms) by using an event triggering system with a multi-laser configuration. We attempt to use our system to obtain the electron temperature and density profiles before and immediately after pellet injection into the large helical device. The obtained profiles exhibit dramatic changes after pellet injection as per our shot-by-shot measurements. We believe that this measurement technique will contribute towards a better understanding of the physics of the pellet deposition.

36 MATERIALS SCIENCE↗

The upgrade of the Thomson scattering system for measurement on the C-2/C-2U devices

The C-2/C-2U Thomson scattering system has been substantially upgraded during the latter phase of C-2/C-2U program. A Rayleigh channel has been added to each of the three polychromators of the C-2/C-2U Thomson scattering system. Onsite spectral calibration has been applied to avoid the issue of different channel responses at different spots on the photomultiplier tube surface. With the added Rayleigh channel, the absolute intensity response of the system is calibrated with Rayleigh scattering in argon gas from 0.1 to 4 Torr, where the Rayleigh scattering signal is comparable to the Thomson scattering signal at electron densities from 1 × 10{sup 13} to 4 × 10{sup 14} cm{sup −3}. A new signal processing algorithm, using a maximum likelihood method and including detailed analysis of different noise contributions within the system, has been developed to obtain electron temperature and density profiles. The system setup, spectral and intensity calibration procedure and its outcome, data analysis, and the results of electron temperature/density profile measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

K-(alpha) X-ray Thomson Scattering From Dense Plasmas

Spectrally resolved Thomson scattering using ultra-fast K-{alpha} x-rays has measured the compression and heating of shocked compressed matter. The evolution and coalescence of two shock waves traveling through a solid density LiH target were characterized by the elastic scattering component. The density and temperature at shock coalescence, 2.2 eV and 1.7 x 10{sup 23}cm{sup -3}, were determined from the plasmon frequency shift and the relative intensity of the elastic and inelastic scattering features in the collective scattering regime. The observation of plasmon scattering at coalescence indicates a transition to the dense metallic state in LiH. The density and temperature regimes accessed in these experiments are relevant for inertial confinement fusion experiments and for the study of planetary formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Real-Time Software for Thomson Scattering Analysis at NSTX-U

The Thomson Scattering Diagnostic on the National Spherical Tokamak eXperiment Upgrade (NSTX-U) has been an essential system for many operational campaigns due to its function of measuring plasma electron density and temperature. Constructive feedback to improve the next plasma discharge, however, has been limited because of in-between shots analysis. Plasma Control, therefore, desires a diagnostic system that is real-time capable. This contribution presents the development of software that demonstrates the feasibility of a real-time Thomson Scattering diagnostic system for NSTX-U. The developed software is able to evaluate the electron temperature and density within 2.5ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

K-alpha X-ray Thomson Scattering From Dense Plasmas

Spectrally resolved Thomson scattering using ultra-fast K-alpha x rays has measured the compression and heating of shocked compressed matter. The evolution and coalescence of two shock waves traveling through a solid density LiH target were characterized by the elastic scattering component. The density and temperature at shock coalescence, 2.2 eV and 1.7x10{sup 23} cm{sup -3}, were determined from the plasmon frequency shift and the relative intensity of the elastic and inelastic scattering features in the collective scattering regime. The observation of plasmon scattering at coalescence indicates a transition to the dense metallic state in LiH. The density and temperature regimes accessed in these experiments are relevant for inertial confinement fusion experiments and for the study of planetary formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved Thomson Scattering on Laboratory Plasma Jets

In this study, Thomson scattering measurements were performed on plasma jets created from a 15-μm-thick radial Al foil load on a 1-MA pulsed power machine. The laser used for these measurements has a maximum energy of 10 J at 526.5 nm. Using the full energy, however, significantly heats the 5x10¹⁸ cm⁻³ jet by inverse bremsstrahlung, creating a density bubble in the jet. To measure the evolving plasma parameters of this laser-heated jet, a streak camera was used to record the scattered spectrum, resulting in the sub-ns time-resolved Thomson scattering. Analysis of the streak camera image showed that the electron temperature of the jet was about 25 eV prior to the laser pulse. The laser then heated the plasma to 80-100 eV within about 2 ns. The electron temperature then stabilized for about 0.5 ns prior to falling at the end of the laser pulse. Jets made from a radial Ti foil showed more heating by the laser than the Al jets, going from 50 to over 150 eV, and heating was detected even when only 1 J of laser energy was used. Also, the ion-acoustic peaks in the scattered spectrum from the Ti jets were significantly narrower than those from Al jets, a result of several possible differences in the plasma created from these two materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of Thomson scattering spectral fits for interpenetrating flows

Collective mode optical Thomson scattering has been used to investigate the interactions of radially convergent ablation flows in Tungsten wire arrays. These experiments were carried out at the Magpie pulsed power facility at Imperial College, London. Analysis of the scattered spectra has provided direct evidence of ablation stream interpenetration on the array axis, and has also revealed a previously unobserved axial deflection of the ablation streams towards the anode as they approach the axis. It is has been suggested that this deflection is caused by the presence of a static magnetic field, advected with the ablation streams, stagnated and accrued around the axis. Analysis of the Thomson scattering spectra involved the calculation and fitting of the multi-component, non-relativistic, Maxwellian spectral density function S (k, ω). The method used to calculate the fits of the data are discussed in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using collective x-ray Thomson scattering to measure temperature and density of warm dense matter

Collective x-ray Thomson scattering allows measuring plasmons, i.e electron plasma oscillations (Langmuir waves). This is manifest in the appearance of spectrally up- and down-shifted spectral features in addition to the Rayleigh signal. The ratio of the up- and down-shifted signals is directly related to detailed balance, allowing to determine the plasma temperature from first principles. The spectral shift of the plasmon signals is sensitive to temperature and electron density. We discuss the experimental considerations that have to be fulfilled to observe plasmon signals with x-ray Thomson scattering. As an example, we describe an experiment that used the Cl Ly-{alpha} x-ray line at 2.96 keV to measure collective Thomson scattering from solid beryllium, isochorically heated to 18 eV. Since temperature measurement based on detailed balance is based on first principles, this method is important to validate models that, for example, calculate the static ion-ion structure factor S{sub ii}(k).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material Assessment for ITER's Collective Thomson Scattering first mirror

The International Thermonuclear Energy Reactor (ITER) Collective Thomson Scattering (CTS) system is a diagnostic instrument that measures plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasi-optical mirrors that are used to produce astigmatic beam patterns, which have impact on the strength and spatial resolution of the diagnostic signal. The mirrors are exposed to neutron radiation, which may alter the quality of the signal received. In this work, three different materials (molybdenum (Mo), stainless steel 316 (SS-316) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to access which of the material studied are best suited for this mirror, considering different neutron radiation loads simulated scenarios defined by ITER, based on the resultant stresses and temperature distributions. For it, the neutron irradiation, and subsequent heat-load on the mirrors are simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, transient thermal-structural Finite Element Analysis (FEA) of the mirror over a 400 s discharge, with and without cooling on the rear side, are conducted using in commercial FEA software ANSYS. Results show that of the tested materials Mo and W are the most suitable material for this application. Even though, this study does not yet consider the variation of the material properties with temperature, it presents a quick initial satisfactory assessment that may be considered in subsequent and more complex analysis. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Average-atom treatment of relaxation time in x-ray Thomson scattering from warm dense matter

Here, the influence of finite relaxation times on Thomson scattering from warm dense plasmas is examined within the framework of the average-atom approximation. Presently most calculations use the collision-free Lindhard dielectric function to evaluate the free-electron contribution to the Thomson cross section. In this work, we use the Mermin dielectric function, which includes relaxation time explicitly. The relaxation time is evaluated by treating the average atom as an impurity in a uniform electron gas and depends critically on the transport cross section. The calculated relaxation rates agree well with values inferred from the Ziman formula for the static conductivity and also with rates inferred from a fit to the frequency-dependent conductivity. Transport cross sections determined by the phase-shift analysis in the average-atom potential are compared with those evaluated in the commonly used Born approximation. The Born approximation converges to the exact cross sections at high energies; however, differences that occur at low energies lead to corresponding differences in relaxation rates. The relative importance of including relaxation time when modeling x-ray Thomson scattering spectra is examined by comparing calculations of the free-electron dynamic structure function for Thomson scattering using Lindhard and Mermin dielectric functions. Applications are given to warm dense Be plasmas, with temperatures ranging from 2 to 32 eV and densities ranging from 2 to 64 g/cc.

74 ATOMIC AND MOLECULAR PHYSICS↗

Influence of local-field corrections on Thomson scattering in collision-dominated two-component plasmas

The dynamic structure factor, which determines the Thomson scattering spectrum, is calculated via an extended Mermin approach. It incorporates the dynamical collision frequency as well as the local-field correction factor. This allows to study systematically the impact of electron-ion collisions as well as electron-electron correlations due to degeneracy and short-range interaction on the characteristics of the Thomson scattering signal. As such, the plasmon dispersion and damping width is calculated for a two-component plasma, where the electron subsystem is completely degenerate. Strong deviations of the plasmon resonance position due to the electron-electron correlations are observed at increasing Brueckner parameters r{sub s}. These results are of paramount importance for the interpretation of collective Thomson scattering spectra, as the determination of the free electron density from the plasmon resonance position requires a precise theory of the plasmon dispersion. Implications due to different approximations for the electron-electron correlation, i.e., different forms of the one-component local-field correction, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative electron temperature measurements of Thomson scattering and electron cyclotron emission diagnostics in TCABR plasmas

We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfven wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak, while the electron cyclotron emission radiometer employs a heterodyne sweeping radiometer. For purely Ohmic discharges, the electron temperature measurements from both diagnostics are in good agreement. Additional Alfven wave heating does not affect the capability of the Thomson scattering diagnostic to measure the instantaneous electron temperature, whereas measurements from the electron cyclotron emission radiometer become underestimates of the actual temperature values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A deep learning approach to fast analysis of collective Thomson scattering spectra

Fast analysis of collective Thomson scattering ion acoustic wave features using a deep convolutional neural network model is presented. The network was trained from spectra to predict the plasma parameters, including ion velocities, population fractions, and ion and electron temperatures. A fully kinetic particle-in-cell simulation was used to model a laboratory astrophysics experiment and simulate a diagnostic image of the ion acoustic wave feature. Network predictions were compared with Bayesian inference of the plasma model parameters for both the simulated and experimentally measured images. Both approaches were fairly accurate predicting the simulated image and the network predictions matched a good portion of the Bayesian results for the experimentally measured image. The Bayesian approach is more robust to noise and motivates future work to train deep learning models with realistic noise. The advantage of the deep learning model is making thousands of predictions in a few hundred milliseconds, compared to a few seconds to minutes per prediction for the optimization and Bayesian approaches presented here. The results demonstrate promising capabilities of deep learning models to analyze Thomson data orders of magnitude faster than conventional methods when using the neural network for standalone analysis. If more rigorous analysis is needed, neural network predictions can be used to quickly initialize other optimization methods and increase chances of success. This is especially useful when the dataset becomes very large or highly dimensional and manually refining initial conditions for the entire dataset are no longer tractable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving the bulk ion region of millimeter-wave collective Thomson scattering spectra at ASDEX Upgrade

Collective Thomson scattering (CTS) measurements provide information about the composition and velocity distribution of confined ion populations in fusion plasmas. The bulk ion part of the CTS spectrum is dominated by scattering off fluctuations driven by the motion of thermalized ion populations. It thus contains information about the ion temperature, rotation velocity, and plasma composition. To resolve the bulk ion region and access this information, we installed a fast acquisition system capable of sampling rates up to 12.5 GS/s in the CTS system at ASDEX Upgrade. CTS spectra with frequency resolution in the range of 1 MHz are then obtained through direct digitization and Fourier analysis of the CTS signal. We here describe the design, calibration, and operation of the fast receiver system and give examples of measured bulk ion CTS spectra showing the effects of changing ion temperature, rotation velocity, and plasma composition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗