Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEM imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging analysis of LDEF craters

Two small craters in Al from the Long Duration Exposure Facility (LDEF) experiment tray A11E00F (no. 74, 119 micron diameter and no. 31, 158 micron diameter) were analyzed using Auger electron spectroscopy (AES), time-of-flight secondary ion mass spectroscopy (TOF-SIMS), low voltage scanning electron microscopy (LVSEM), and SEM energy dispersive spectroscopy (EDS). High resolution images and sensitive elemental and molecular analysis were obtained with this combined approach. The result of these analyses are presented.

Radicatidibrozolo, F.↗

Orion Artemis-1 Post-Flight Characterization

This abstract discusses the post-flight characterization of the heatshield used in the Orion Artemis-1 mission, which is a significant milestone in human space exploration. The Artemis-1 heatshield is a crucial component designed to protect the spacecraft during re-entry into Earth's atmosphere. It experiences extreme temperatures and forces as it encounters the intense heat generated by the friction between the spacecraft and the atmospheric gases. The post-flight characterization of the Artemis-1 heatshield involves analyzing its surface morphology and elemental composition. This analysis provides valuable insights into the performance and durability of the heatshield during the mission. By utilizing techniques such as Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Spectroscopy (EDX), a detailed examination of the heatshield’s surface features, and elemental composition can be conducted. The SEM analysis offers high-resolution imaging capabilities, enabling detailed observations of the heatshield’s surface morphology. EDX analysis provides elemental analysis, allowing for an assessment of any compositional changes induced by the thermal and environmental conditions experienced during the mission. This information is crucial for understanding the material's response to the extreme conditions and identifying any potential issues or degradation. Furthermore, density profiling analysis is performed to measure density variations across the depth of the heatshield material. This analysis offers insights into the effects of the mission on the heatshield, such as potential ablation, or changes in material porosity. Understanding these density variations helps to evaluate the heatshield's structural integrity and its ability to withstand future missions. This knowledge contributes to the ongoing development of advanced heatshield designs, enhancing their thermal protection capabilities and ensuring the safety of future manned missions to the Moon and beyond.

Tane Boghozian↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Solar Flare Track Exposure Ages in Regolith Particles: A Calibration for Transmission Electron Microscope Measurements

Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Space weathering effects result from multiple processes including: exposure to the solar wind, which results in ion damage and implantation effects that are preserved in the rims of grains (typically the outermost 100 nm); cosmic ray and solar flare activity, which result in track formation; and impact processes that result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. Determining the rate at which these effects accumulate in the grains during their space exposure is critical to studies of the surface evolution of airless bodies. Solar flare energetic particles (mainly Fe-group nuclei) have a penetration depth of a few millimeters and leave a trail of ionization damage in insulating materials that is readily observable by transmission electron microscope (TEM) imaging. The density of solar flare particle tracks is used to infer the length of time an object was at or near the regolith surface (i.e., its exposure age). Track measurements by TEM methods are routine, yet track production rate calibrations have only been determined using chemical etching techniques [e.g., 1, and references therein]. We used focused ion beam-scanning electron microscope (FIB-SEM) sample preparation techniques combined with TEM imaging to determine the track density/exposure age relations for lunar rock 64455. The 64455 sample was used earlier by [2] to determine a track production rate by chemical etching of tracks in anorthite. Here, we show that combined FIB/TEM techniques provide a more accurate determination of a track production rate and also allow us to extend the calibration to solar flare tracks in olivine.

Berger, Eve L.↗

Pink Spinel in Apollo Impact Melt Rock 68815: Implications for Mg-Suite Magmatism

Introduction: Magnesian rocks from the lunar highlands are collectively termed the Mg-suite. Characterized by high (>60) Mg# (molar 100×Mg/[Mg+Fe]) in mafic phases and calcic plagioclase, these rocks are plutonic to hypabyssal in origin, and include a range of bulk mineralogies such as troctolites, dunites, norites, gabbronorites, and spinel troctolites [1]. These Mg-suite lithologies have distinct trace element concentrations and ratios that differentiate them from other lunar rock types. These rocks are ancient, generally dated to between 4.5 and 4.1 Ga, although it is unknown if this represents the full range of Mg-suite ages [1–2]. Among the Mg-suite lithologies, the spinel troctolites are relatively rare, to date only found in polymict breccias [3]. Spinel troctolites, as their name suggests, consist of calcic plagioclase and forsteritic olivine, with minor amounts of spinel (MgAl2O4), ± pyroxene and cordierite [1,4]. This form of spinel is often called ‘pink’ spinel because of its appearance in thin section under plane polarized light (PPL; Fig. 1), due to minor amounts of Cr. Spinel troctolites are generally plutonic or hypabyssal in origin (subsequently exhumed and incorporated into polymict breccias), or formed through impact processes (e.g., crystalline impact melt) [5]. A spinel-rich lithology has also been found in the Moscoviense region of the Moon via the Moon Mineralogy Mapper (M3) and lacks other mafic phases [6]. Finally, while the Mg-suite sampled thus far consists of plutonic (or hypabyssal) rocks, the question remains if such magmas could have erupted on the surface of the Moon [7]. These magmas have much lower density than mare basalts, but little sample or remote sensing evidence has been found to support the idea that extrusive Mg-suite volcanism occurred [7]. Here, we present a coordinated microanalytical study of spinel-bearing lithic and mineral clasts found in Apollo sample 68815. These data will be used to understand their petrogenesis (magmatic or impact) and modification histories, and to shed light on the existence of volcanic Mg-suite rocks. Sample Description: Apollo sample 68815 is a polymict impact melt breccia containing a variety of lithic and mineral fragments embedded in devitrified impact melt. This sample was chipped off the top of a boulder at Station 8 during the Apollo 16 mission and had an original weight of nearly 1.8 kg. In this study, we investigated two polished thin sections of 68815: 68815,17 and 68815,148, both containing spinel. Methods: The thin sections of 68815 were studied using optical light microscopy (PPL, cross-polarized light, and reflected light) with a Keyence VHX-7100 Digital Microscope. Each section was then X-ray mapped for 13–14 elements using a Cameca SX100 electron probe microanalyzer (EPMA) located in the Kuiper Materials Imaging and Characterization Facility (KMICF) at the University of Arizona. We have obtained geochemical information about the phases (olivine, plagioclase, spinel, pyroxene) in the thin sections also using the EPMA. In addition, we have used ThermoScientific Helios NanoLab 660 Focused-Ion-Beam Scanning-Electron Microscope (FIB-SEM) and a Hitachi S-4800 SEM (both in KMICF) to obtain backscattered electron (BSE) images and energy dispersive Xray spectrometry (EDS) maps of areas of interest. Using a JEOL 7900F SEM at the Astromaterials Research & Exploration Science (ARES) at NASA Johnson Space Center (JSC), we have obtained electron backscatter diffraction (EBSD) maps of the spinel-bearing portions of the thin sections. The EBSD data were collected under beam conditions of 20 kV, and ~90 μA, with step sizes varying from 0.05 to 2 μm. Following EBSD data collection, we processed the data using AZtecCrystal and MTEX, a free MATLAB toolbox. Results: We have found clasts with subophitic textures, that consist of primarily olivine and plagioclase, with minor amounts of pink Mg-Al spinel and pyroxene (Fig. 1). These clasts are up to ~1 mm in length and contain spinels up to 50 μm across. We have additionally identified pink Mg-Al spinels within the impact melt (i.e., not contained in lithic clasts) in both thin sections. In one instance, a single spinel grain is approximately 300 μm across (Fig. 1b, 2). The spinel fragments embedded in impact melt have varying compositions, typically distinct from the compositions of spinels in the lithic clasts. Spinel-Bearing Clasts: Ten lithic clasts with similar textures and mineral compositions were identified between 68815,17 (two clasts) and ,148 (eight clasts). These clasts fall into two groups. The first has skeletal olivine with intergranular plagioclase, with minor amounts of pyroxene and spinel (Fig. 1a, 2c, 2d). The spinel in these clasts are found amid the plagioclase. The second group have an intergranular texture of olivine and plagioclase, again with minor spinel and pyroxene. The second group may contain spinels surrounded by plagioclase, and spinels enclosed in olivine. Spinels located within both clast types range from no apparent Cr zoning, to reverse zoning (Cr-enrichment inward; Fig. 2d), to normal zoning (Cr-enrichment outward). In the clasts thus far investigated with EPMA, plagioclase compositions range from An# (molar 100×Ca/[Ca+Na+K]) 92–96. Olivine Mg# ranged from 77 to 94, while pyroxene had Mg# from 54–84. Spinel in the clasts have Cr# (molar 100×Cr/[Cr+Al]) 2–4 and Mg# 88–91, which is within the range of pristine and plutonic spinel troctolites [8]. Isolated Spinels: These crystals are generally euhedral to subhedral, and can exhibit reverse Cr zoning (Cr enrichment inward) or no apparent Cr zoning. The spinels thus far investigated via EPMA have Cr# 9–14 and Mg# 65–82. The Cr# for these spinels is within the range reported by [8], but have lower Mg#. Future Work: We will continue to process the EBSD data for these lithic and mineral clasts. We will also continue to characterize these clasts using EPMA and SEM. By thoroughly characterizing the various spinels and spinel-bearing clasts, we aim to constrain the petrogenesis of these minerals and rock fragments. Acknowledgments: We thank NASA for the loan of these thin sections. We thank Ken Domanik and Jerry Chang for their support with data collection. Work was supported by a University of Arizona RII Core Facilities Pilot Program grant and start-up funds to JJB. We acknowledge support from NASA’s Planetary Science Research program for analysis performed at JSC. References: [1] Shearer C. K. et al. (2015) Am. Min. 100, 294–325. [2] Borg L. E. et al. (2020) GCA 290, 312–332. [3] Warren P. H. (1993) Am. Min. 78, 360–376. [4] Dymek R. F. et al. (1976) LPS VII, 2335–2378. [5] Treiman et al. (2019) Am. Min. 104, 370–384. [6] Pieters et al. (2011) JGR: Plan. 116:E00G08. [7] Prissel et al. (2016) Icarus 277, 319–329. [8] Prissel et al. (2016) Am. Min. 101, 1624–1635.

spinel↗

Surface characterization and testing II; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on surface characterization and testing are presented. Individual topics addressed include: simple Hartmann test data interpretation, optimum configuration of the Offner null corrector, system for phase-shifting interferometry in the presence of vibration, fringe variation and visibility in speckle-shearing interferometry, functional integral representation of rough surfaces, calibration of surface heights in an interferometric optical profiler, image formation in common path differential profilometers, SEM of optical surfaces, measuring surface profiles with scanning tunneling microscopes, surface profile measurements of curved parts, high-resolution optical profiler, scanning heterodyne interferometer with immunity from microphonics, real-time crystal axis measurements of semiconductor materials, radial metrology with a panoramic annular lens, surface analysis for the characterization of defects in thin-film processes, Spacelab Optical Viewport glass assembly optical test program for the Starlab mission, scanning differential intensity and phase system for optical metrology.

Greivenkamp, John E.↗

Contactless Growth of ZnSe Single Crystals by Physical Vapor Transport

ZnSe crystals were grown by self-seeded physical vapor transport (PVT) technique in the horizontal configuration. The source materials were heat treated by H2 reduction to remove the oxide followed by baking under dynamic vacuum to adjust the source composition toward that of congruent sublimation. Contactless growth of ZnSe single crystals have been performed consistently using three different source materials. The crystals grew away from the wall during the later stage of the growth with large (110) facets tend to align parallel to the gravity direction. The Scanning Electron Micrography (SEM) micrographs and the Atomic Force Microscope (AFM) images showed that large (110) terraces and steps dominate the as-grown facets. The measured residual gas pressures in the processed ampoules agree well among various source materials and the major components were CO and H2. No preferred growth direction was found. The one-dimensional diffusion model on the mass flux of a multi-species PVT system was employed to analyze the conditions for contactless growth. The calculated thermal profile for supersaturation is very close to the thermal profile measured inside the empty furnace bore in the region of contactless growth. The effects of convective flows in the vapor phase inside the ampoule on the growth processes are discussed.

Su, Ching-Hua↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for the Surface of Mars: An Instrument for the Planetary Science Community

The Miniaturized Variable Pressure Scanning Electron Microscope(MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Science (ROSES), will build upon previous miniaturized SEM designs for lunar and International Space Station (ISS) applications and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. By the end of the PICASSO work, a prototype of the primary proof-of-concept components (i.e., the electron gun, focusing optics and scanning system)will be assembled and preliminary testing in a Mars analog chamber at the Jet Propulsion Laboratory will be completed to partially fulfill Technology Readiness Level to 5 requirements for those components. The team plans to have Secondary Electron Imaging(SEI), Backscattered Electron (BSE) detection, and Energy Dispersive Spectroscopy (EDS) capabilities through the MVP-SEM.

Mars↗

Characterizing Damage Accumulation in CMCs

Silicon carbide / silicon carbide ceramic matrix composites (SiC/SiC CMCs) are structural ceramics that are well-suited for the extreme environment conditions of aerospace applications largely due to their low weight, creep resistance, damage tolerance, and high specific strength. In CMCs, the initiation and evolution of damage is influenced by a number of factors including characteristics of the constituent landscape (porosity, interfacial properties, and geometric distribution of CMC constituents), thermo-mechanical loading parameters, and environmental conditions. However, much is still unknown about these factors and the interactions between them. In order to accurately predict the lifetimes of these advanced composites, it is critical to understand the evolution of damage and to characterize which early damage mechanisms (and their relationship to key microstructural features) subsequently lead to crack coalescence and macroscopic failure. This research focuses on the use of a multi-modal, experimental approach to examine the relative activity of surface and subsurface damage mechanisms in CMCs. The impact of fabrication choices on the evolution of damage to final failure, and the influence of constituent architecture on early damage mechanisms, are investigated. This approach combines acoustic emission (AE) with microscale deformation tracking via digital image correlation inside a scanning electron microscope (SEM-DIC). The potential application of this combined approach towards characterization of damage in SiC/SiC CMCs under more complex testing conditions is explored.

Swaminathan, Bhavana↗

Effects of low earth orbit on the optical performance of multi-layer enhanced high reflectance mirrors

Two mirror designs developed for space applications were flown along with a standard mid-infrared design on the leading and trailing edges of the Long Duration Exposure Facility (LDEF). Preliminary observations of induced changes in optical performance of ZnS-coated mirrors and impact-related microstructural and microchemical effects are described in the proceedings of the First LDEF Post-Retrieval Symposium. In this paper, effects of the induced environment and meteoroid/debris impacts on mirror performance are described in more detail. Also, an analysis of reflectance spectra using the results of Auger and secondary ion mass spectroscopy (SIMS) profiling measurements are used to identify an optical-degradation mechanism for the ZnS-coated mirrors. Structural damage associated with a high-velocity impact on a (Si/Al2O3)-coated mirror was imaged optically and with scanning electron and atomic force microscopy (SEM and AFM). Scanning Auger and SIMS analysis provided chemical mapping of selected impact sites. The impact data suggest design and fabrication modifications for obtaining improved mechanical performance using a design variation identified in preflight laboratory simulations. Auger surface profile and SIMS imaging data verified the conclusion that secondary impacts are the source of contamination associated with the dendrites grown on the leading-edge ZnS-coated test samples. It was also found that dendrites can be grown in the laboratory by irradiating contaminated sites on a trailing-edge ZnS-coated sample with a rastered electron beam. These results suggest a mechanism for dendrite growth.

Donovan, Terence↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

Microscope↗

Construction of a Virtual Scanning Electron Microscope (VSEM)

The Imaging Technology Group (ITG) proposed to develop a Virtual SEM (VSEM) application and supporting materials as the first installed instrument in NASA s Virtual Laboratory Project. The instrument was to be a simulator modeled after an existing SEM, and was to mimic that real instrument as closely as possible. Virtual samples would be developed and provided along with the instrument, which would be written in Java.

Fried, Glenn↗

Microscopic Observation of Self-Propagation of Calcifying Nanoparticles (Nanobacteria)

Biologists typically define living organisms as carbon and water-based cellular forms with :self-replication" as the fundamental trait of the life process. However, this standard dictionary definition of life does not help scientists to categorize self-replicators like viruses, prions, proteons and artificial life. CNP also named nanobacteria were discovered in early 1990s as about 100 nanometer-sized bacteria-like particles with unique apatite mineral-shells around them, and found to be associated with pathological-calcification related diseases. Although CNP have been isolated and cultured from mammalian blood and diseased calcified tissues, and their biomineralizing properties well established, their biological nature and self-replicating capability have always been severely challenged. The terms "self-replication", "self-assembly" or "self-propagation" have been widely used for all systems including nanomachines, crystals, computer viruses and memes. In a simple taxonomy, all biological and non-biological "self replicators", have been classified into "living" or "nonliving" based on the properties of the systems and the amount of support they require to self-replicate. To enhance our understanding about self-replicating nature of CNP, we have investigated their growth in specific culture conditions using conventional inverted light microscope and BioStation IM, Nikon s latest time-lapse imaging system. Their morphological structure was examined using scanning (SEM) and transmission (TEM) electron microscopy. This present study, in conjunction with previous findings of metabolic activity, antibiotic sensitivity, antibody specificity, morphological aspects and infectivity, all concomitantly validate CNP as living self-replicators.

Mathew, Grace↗

TPSAS-NF1676L-17800-DND

Currently, there are two national challenge problems that guide much of the research in durability and damage tolerance at NASA Langley. The first, Airframe Digital Twin, is a concept that combines as-built vehicle components, as-experienced loads and environments, and other vehicle-specific characteristics to enable ultrahigh fidelity modeling of aircraft and spacecraft throughout their service lives. The second, Materials Genome Initiative, is an analog to the Human Genome Project, and is intended to improve the rate at which materials scientists can discover, understand fundamental physics, and improve material systems. This presentation will highlight several research projects ongoing at NASA Langley that are in support of the above challenge problems. Two of those topics will be the subject of detailed discussion. First, investigations of microstructurally-small fatigue cracking (MSFC) in Al-2Cu and Al-4Cu, fabricated in-house, will be presented. Single- and oligo-crystals of Al-Cu specimens were loaded in uniaxial fatigue, while high-resolution in-situ measurements of deformation were made using image correlation (IC) in a scanning-electron microscope (SEM). The Al-Cu specimens were then replicated as crystal plasticity finite element models (CPFEM), where evolution of slip localization near grain boundaries was computed. Comparison among experiment and CPFEM is made. In addition, XRay diffraction measurements of the as-fabricated specimens were carried out, where direct measurements of the embedded copper precipitates were made, and their influence on growing MSFCs were directly observed. The second main topic will illustrate ongoing work in the area of so-called damage-sensing particles. In this work, shape-memory alloys are embedded in an aluminum alloy matrix. Upon the propagation of a fatigue crack, these particles undergo a strain-induced phase transformation which is detected using an acoustic sensor, providing real-time information on propagating cracks. Experiments and simulations regarding the development of this system will also be detailed.

Jacob Hochhalter↗

The MOCHII ISS National Laboratory: The First Spacecraft Based Scanning Electron Microscope

Introduction: Scanning electron microscopy (SEM) in concert with element identification by energy dispersive Xray (EDX) spectroscopy has become an indispensable tool in the analyses of extraterrestrial materials. Nevertheless, to-date, SEM-EDX instrumentation has remained purely in the purview of terrestrial laboratories due to their size, complexity, and operational requirements. However, in January 2022 a miniaturized SEM-EDX called MOCHII became the first successful space-based instrument of its kind, following its deployment onboard the International Space Station (ISS). It represents the culmination of nearly 40 years of technological development. We have performed an on-orbit study with MOCHII with the goal of evaluating its potential as the progenitor of a new generation of spacecraftbased instruments for use in future manned and robotic planetary exploration missions. Out goal has been to validate the on-orbit investigation of samples relevant to astromaterials and astrobiology. We have performed in-situ analyses on standards and a freshly fractured fragment of the Martian meteorite Allan Hills 84001 which was first analyzed, prior to launch, using an engineering MOCHII ground unit located at Johnson Space Center in Houston. Results of both imaging and compositional analyses substantiates the utility of remote SEM-EDX analyses in low Earth orbit (LEO).

Miniature Scanning Electron Microscope↗

Microfossils in the Murchison and Rainbow Carbonaceous Meteorites

Astrobiologists are working to develop methodologies for the recognition of bacterial microfossils, biominerals, and chemical biomarkers in terrestrial rocks, to provide a basis for the scientific assessment of possible microfossils in meteorites and other Astromaterials. During the past 5 years, we have conducted electron microscopy investigations to understand the morphology and chemical composition of microfossils in ancient terrestrial rocks and to search for microfossils presence in meteorites. We have detected evidence of indigenous microfossils and biominerals in-situ in every carbonaceous meteorite investigated but have found no evidence for microfossils in the nickel-iron and stony meteorites studied. In this paper, we provide a brief review of prior evidence for microfossils in meteorites and present Scanning and Environmental Scanning Electron Microscope (SEM and ESEM) and Field Emission Scanning Electron Microscope (FESEM) images of microfossils found in-situ in freshly fractured surfaces of the Murchison and Rainbow meteorites. We describe the techniques and methods used to protect the samples from contamination and for the discrimination of indigenous microfossils from recent terrestrial contaminants We provide data from Energy Dispersive Spectroscopy (EDS) and Link microprobe analysis of the chemical elements and 2D x-ray maps as strong evidence that these biogenic forms are indigenous to the meteorites and cannot logically be interpreted as recent bio-contaminants. We show evidence of framboidal magnetites and pyrites and compare them with framboidal magnetites and pyrites found in Cambrian richs from the Siberian Platform.

Hoover, Richard B.↗

Methodology for Producing a Uniform Distribution of UO2 in a Tungsten Matrix

Current work at NASA's Marshall Space Flight Center (MSFC) is focused on the development CERMET fuel materials for Nuclear Thermal Propulsion (NTP). The CERMETs consist of uranium dioxide (UO2) fuel particles embedded in a tungsten (W) metal matrix. Initial testing of W-UO2 samples fabricated from fine angular powders performed reasonably well, but suffered from significant fuel loss during repeated thermal cycling due to agglomeration of the UO2 (1). The blended powder mixtures resulted in a non-uniform dispersion of the UO2 particles in the tungsten matrix, which allows rapid vaporization of the interconnected UO2 from the sample edges into the bulk material. Also, the angular powders create areas of stress concentrations due to thermal expansion mismatch, which eventually cracks the tungsten matrix. Evenly coating spherical UO2 particles with chemical vapor deposited (CVD) tungsten prior to consolidation was previously demonstrated to provide improved performance. However, the CVD processing technology is expensive and not currently available. In order to reduce cost and enhance performance, a powder coating process has been developed at MSFC to produce a uniform distribution of the spherical UO2 particles in a tungsten matrix. The method involves utilization of a polyethylene binder during mixing which leads to fine tungsten powders clinging to the larger UO2 spherical particles. This process was developed using HfO2 as a surrogate for UO2. Enough powder was mixed to make 8 discs (2cm diameter x 8mm thickness) using spark plasma sintering. A uniaxial pressure of 50 MPa was used at four different temperatures (2 samples at each temperature). The first two samples were heated to 1400C and 1500C respectively for 5 minutes. Densities for these samples were less than 85% of theoretical, so the time at temperature was increased to 20 minutes for the remaining samples. The highest densities were achieved for the two samples sintered at 1700C (approx. 92% of theoretical). Scanning electron microscopy (SEM) of the mixed powders and the sintered samples along with energy dispersive x-ray analysis was obtained. The SEM of the powders clearly show the fine W powder adhered to the larger HfO2 particles and a uniform distribution of HfO2 particles in a tungsten matrix upon densification. Vicker's Microhardness testing was also performed on all samples using 0.5, 1.0 and 2.0 kg loads. Five indents were made at each load level. All indents were placed in the tungsten matrix to assist as a proxy in measuring densification. The highest hardness value was obtained for the 1700C specimens. The hardness average for these samples was 312.14 MPa. This powder processing method has been applied to W/UO2 powders with the SEM of the powders appearing similar to the W/HfO2 powder images.

Tucker, Dennis S.↗